• Title/Summary/Keyword: Roll angle difference

Search Result 27, Processing Time 0.022 seconds

A Study on the Characteristics of Ceramic Ball Bearing (세라믹 볼베어링의 특성해석에 관한 연구)

  • 김완두;한동철
    • Tribology and Lubricants
    • /
    • v.8 no.2
    • /
    • pp.64-72
    • /
    • 1992
  • The recent trends of rotating machinery demand high speed and high temperature operation, and the bearing with new material is required to be developed. Ceramic, especially silicon nitride, have been receiving attention as alternative material to conventional bearing steel. Ceramic ball bearing offers major performance advantages over steel bearing, for instance, high speed, maginal lubrication, high temperature, improved corrosion resistance and nonmagnetic capabilities etc.. In this paper, the mechanical characteristics of ceramic ball bearing (hybrid ceramic bearing and all ceramic bearing) were investigated, and the characteristics of ceramic bearing were compared with that of steel bearing. Deep groove ball bearing 6208 was taken the object of analysis. The main results of analysis were followings: the radial stiffness of hybrid and all ceramic bearing were 112% and 130% that of steel bearing, and the axial stiffness of all ceramic bearing was 110% that of steel bearing. According as rotating speed was up, the ball load, the contact angle, the contact stress and the spin-to-roll ratio between ball and raceway of ceramic bearing were far smaller than these of steel bearing. And there was not a significant difference between the minimum film thickness of ceramic bearing and steel bearing. It is expected that this research is contributed to enhanced fundamental technology for the practical applications of ceramic ball bearing.

A Design of Fuzzy Control System for Moving Object Tracking (이동물체 추적을 위한 퍼지제어 시스템 설계)

  • 강석범;김재기;양태규
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.4
    • /
    • pp.738-745
    • /
    • 2001
  • In this paper, when the moving object move to the three-dimentional space, the tracking system track the moving object using the fuzzy reasoning. The joint angle el of the manipulator rotate from $0^{\circ}\; to\; 360^{\circ}$ , and the joint angle $\theta_2$rotate from$0^{\circ}\; to\; 360^{\circ}$. The fuzzy singleton is used for fuzzification and the control rule is twenty five and the fuzzy inference method is simplified Mamdani's reasoning and the defuzzification is the SCOG(Simplified Center Of Gravity) of the fuzzy controller To measure of the performance of the designed system, the fuzzy controller is compared with the CTM(Computed Torque Method) controller at the same condition. when the disturbance torque is ON, the both of CTM and fuzzy controller tracked object without error, However, the disturbance torque changed 0.4N, the CTM controller is 10 times greater than fuzzy controller at the sum of absolute error difference. The designed system is showed it's robustness against with disturbance.

  • PDF

Dynamics modeling and performance analysis for the underwater glider (수중 글라이더의 운동특성을 고려한 동역학 모델링 및 운동성능 해석)

  • Nam, Keon-Seok;Bae, Jae-Hyeon;Jeong, Sang-Ki;Lee, Shin-Je;Kim, Joon-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.7
    • /
    • pp.709-715
    • /
    • 2015
  • Underwater gliders do not typically have separate propellers for forward motion. They generate propulsive forces based on the difference between their buoyancy and gravity. They can control the volume from the buoyancy engine to adjust the propulsive force. In addition, the attitude of the underwater glider is controlled by a rubberless motion controller. The motion controller can change the mass center and moment of inertia of the inner moving mass. Owing to the change in these parameters, the attitude of the underwater glider is changed. In this study, we derive nonlinear, six degree of freedom (DOF) mathematical models for the motion controller and buoyancy engine. Using these equations, we perform dynamic simulations of the proposed underwater glider, and verify the suitability of the design and dynamic performances of the proposed underwater glider. We then perform the motion control simulation for the pitch and roll angle, and analyze the dynamic performance according to the pitch and roll angles.

Evaluation on the Accuracy of Targeting Error Correction Through the Application of Target Locating System in Robotic CyberKnife (로봇 사이버나이프에서 위치인식시스템을 이용한 Targeting Error값 보정의 정확성 평가)

  • Jeong, Young-Joon;Jung, Jae-Hong;Lim, Kwang-Chae;Cho, Eun-Ju
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Purpose: The purpose is to evaluate the accuracy of correcting the targeting error through the Target Location System (TLS) for the location change error of the reference point which arises from the movement or motion of patient during the treatment using the CyberKnife. Materials and Methods: In this test, Gafchromic MD-55 film was inserted into the head and neck phantom to analyze the accuracy of the targeting, and then the 6 MV X-ray of CyberKnife (CyberKnife Robotic Radiosurgery System G4, Accuray, US) was irradiated. End to End (E2E) program was used to analyze the accuracy of targeting, which is provided by Accuray Corporation. To compute the error of the targeting, the test was carried out with the films that were irradiated 12 times by maintaining the distance within the rage of $0{\pm}0.2\;mm$ toward x, y, z from the reference point and maintaining the angle within the rage of $0{\pm}0.2^{\circ}$ toward roll, pitch, yaw, and then with the films which were irradiated 6 times by applying intentional movement. And the correlation in the average value of the reference film and the test film were analyzed through independent samples t-test. In addition, the consistency of dose distribution through gamma-index method (dose difference: 3%) was quantified, compared, and analyzed by varying the distance to agreement (DTA) to 1 mm, 1.5 mm, 2 mm, respectively. Results: E2E test result indicated that the average error of the reference film was 0.405 mm and the standard deviation was 0.069 mm. The average error of the test film was 0.413 mm with the standard deviation of 0.121 mm. The result of independent sampling t-test for both averages showed that the significant probability was P=0.836 (confidence level: 95%). Besides, by comparing the consistency of dose distribution of DTA through 1 mm, 1.5 mm, 2 mm, it was found that the average dose distribution of axial film was 95.04%, 97.56%, 98.13%, respectively in 3,314 locations of the reference film, consistent with the average dose distribution of sagittal film that was 95.47%, 97.68%, 98.47%, respectively. By comparing with the test film, it was found that the average dose distribution of axial film was 96.38%, 97.57%, 98.04%, respectively, at 3,323 locations, consistent with the average dose distribution of sagittal film which was 95.50%, 97.87%, 98.36%, respectively. Conclusion: Robotic CyberKnife traces and complements in real time the error in the location change of the reference point caused by the motion or movement of patient during the treatment and provides the accuracy with the consistency of over 95% dose distribution and the targeting error below 1 mm.

  • PDF

Development of Wireless Ambulatory System Measuring 3-D Motion as Podiatric Diagnosis (족부 진단용 3차원 움직임 측정을 위한 무선 이동형 시스템 개발)

  • Kim, Jin-Ho;Kim, Hwa-In;Kim, Dong-Wook;Won, Yong-Gwan;Kim, Jung-Ja
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.5B
    • /
    • pp.502-510
    • /
    • 2011
  • In this research, a wireless movable systems is introduced that is applicable for real-world clinical examination in order to resolve the inconvenience of wired motion analysis system which uses markers by measuring more accurately the angle of the 3D motion. The system is composed of bluetooth data transmission and 6 DOF inertial measurement system that is composed of 3-axis acceleration and 3-axis gyroscope. The samples were collected from 10 feet of 5 young children who were confirmed as patients having flat feet and achilles tendonitis by podiatric expert in pediatrics, and the validity of the system was evaluated by comparison with the opinion by the expert using the EMG data and the data measured by the developed system. ROM of ankle was measured by the difference between the maximum and the minimum peaks of 3-axis values (pitch, roll and yaw) measured at lateral malleolus bone, and based on this measured value, the eversion rate became relatively higher as flat feet state become worse, which is equivalent to the opinion from the podiatric experts. It was shown that there is a relation between the certain muscle activities and the abnormal motion of foot caused by disease.

Effect of Packaging Materials and Storage Temperature on the Quality of Dried Lotus Root (Nelumbo nucifera G.) (포장재 및 저장온도에 따른 건조 연근의 품질특성)

  • Kwon, Oh-Heun;Ryu, Jung-A;Kang, Dong-Kyoon;Choe, So-Young;Lee, Hye-Ryun
    • Food Science and Preservation
    • /
    • v.17 no.6
    • /
    • pp.777-783
    • /
    • 2010
  • The effects of packaging materials and storage temperature on the quality of dried lotus roots (NelumbonuciferaG.) were studied during 330 days of storage. Using four commercial types of packaging, (PE [polyethylene] film bags, PP [polypropylene] film bags, gunny roll, and paper bags), and four different storage temperatures (-5, 0, 10, and $20^{\circ}C$), changes in moisture content, hardness, color, and sensory qualities of dried lotus roots were investigated. The moisture contents of dried lotus roots stored in PE and PP film bags were higher than those of roots stored in gunny and paper bags. A major difference in moisture content was apparent when roots stored in gunny bags and paper bags were compared. Hue angle values were stable in roots stored in gunny and paper bags at all temperatures. Hardness decreased slightly with increased storage time in PE and PP film bags. Decay rate and marketability of roots stored in PE and PP film bags at $-5^{\circ}C$ were acceptable. The results showed that dried roots packaged with PE and PP were stable in quality, in contrast to roots stored in gunny and paper bags.

Upward, Downward Stair Detection Method by using Obliq ue Distance (사거리를 이용한 상향, 하향 계단 검출 방법)

  • Gu, Bongen;Lee, Haeun;Kwon, Hyeokmin;Yoo, Jihyeon;Lee, Daho;Kim, Taehoon
    • Journal of Platform Technology
    • /
    • v.10 no.2
    • /
    • pp.10-19
    • /
    • 2022
  • Moving assistant devices for people who are difficult to move are becoming electric-powered and automated. These moving assistant devices are not suitable for moving stairs at which the height between floor surfaces is different because these devices are designed and manufactured for flatland moving. An electric-powered and automated moving assistant device should change direction or stop when it approaches stairs in a movement direction. If the user or automatic control system does not change direction or stop in time, a moving assistant device can roll over or collide with stairs. In this paper, we propose a stairs detection method by using oblique distance measured by one sensor tilted to flatland. The method proposed in this paper can detect upward or downward stairs by using a difference between a predicted and measured oblique distance in considering a tilted angle of a sensor for measuring an oblique distance and installation height of the sensor on a moving object. Before the device enters a stairs region, if our proposed method provides information about detected stairs to a device's controller, the controller can do adequate action to avoid the accident.