• 제목/요약/키워드: Robot wrist

검색결과 83건 처리시간 0.038초

로보트를 이용한 컨베이어상에서의 연속 이동조립

  • 박용길;최현영;조형석;권대갑;곽윤근;김완수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.211-215
    • /
    • 1989
  • This paper describes a dynamic robotic assembly system in which an industrial robot executes peg-in-hole task in a moving state. As an effective means to synchronize the end-effector of the robot with the moving conveyor this work uses a control algorithm which is essentially a PID position control scheme combined with velocity feedforward loop. A RCC wrist is used for the inserting task and its force responses are investigated for various tracking conditions and inserting velocities through a series of experiments.

  • PDF

On a Posture Control of Human Robot Master Arm

  • Moon, Jin-Soo;Kim, Cheul-U
    • 조명전기설비학회논문지
    • /
    • 제20권9호
    • /
    • pp.24-31
    • /
    • 2006
  • This study developed a human robot mast arm, which has a structure similar to the human arm, with the objective of taking over human works. The robot arm was structured to reproduce human actions using three axes on each of the shoulder and the wrist based on mechanics, and the actuator of each axis adopted an ordinary DC motor. The servo system of the actuator is a one body type employing an amp for electric power, and it was designed to be small and lightweight for easy installation. We examined the posture control characteristics of the developed robot mast arm in order to test its interlocking, continuous motions and reliability.

폐암에서 로봇을 이용한 폐절제술 (Robot-Assisted Pulmonary Resection For Lung Cancer)

  • 이현성;장희진
    • 대한기관식도과학회지
    • /
    • 제17권2호
    • /
    • pp.92-97
    • /
    • 2011
  • MMinimally invasive surgery (MIS) for early stage lung cancer has been an important treatment modality. However, the ergonomic discomfort and counterintuitive instruments hindered the application of video-assisted thoracic surgery (VATS) to more advanced procedures. To improve the compliance with MIS, robotic surgery was adopted. This advance aimed to alleviate the shortcomings of VATS by maximizing the comfort of the surgeon while providing instruments that enabled technically demanding operations and three-dimensional views with increased freedom for intrathoracic movement owing to EndoWrist$^{(R)}$. In this session, we introduced the clinical applications and its results of robot-assisted thoracic surgery in the field of lung cancer surgery. In conclusion, robot-assisted pulmonary resection with lymph node dissection for lung cancer is safe as well as feasible, and it results in a satisfying postoperative outcome. Robot-assisted surgery may provide a good alternative to conventional open or thoracoscopic surgery for lung cancer, provided that the cost effectiveness and long-term prognosis are confirmed.

  • PDF

NC데이타와 Off-Line Program을 이용한 연마 로봇 시스템 개발

  • 오영섭;유범상;양균의
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.692-697
    • /
    • 1997
  • This paper presents a method of grinding and polishing automation of precision die after CNC machining. The method employs a robot system equipped with a pneumatic spindle and a special abrasive film pad. The robote program is automatically generated off-line from a PC and downloaded to robot controller. Position and orientation data for the program is supplied from cutter contact (CC) data of NC machining process. This eliminates separate robot teaching process. This paper aims at practical automation of die finishing process which is very time consuming and suffering from shortage of workpeople. Time loss for changeover from one product to next is eliminated by off-line programming exploiting appropriate NC machining data. Dextrous 6-axis robot with rigid wrist and simple tooling enables the process applicable to larger, rather complex 3 dimensional free surfaces

  • PDF

생체 모방학과 트리즈를 이용한 보급형 서비스 로봇 핸드의 설계 (Design of an Economic Service Robot Hand Based on Biomimetics and TRIZ)

  • 고훈건;조창희;김권희
    • 대한기계학회논문집A
    • /
    • 제34권11호
    • /
    • pp.1741-1747
    • /
    • 2010
  • 본 연구에서는 원격 조정 매니퓰레이터에 적용할 수 있는 보급형 서비스 로봇 암을 개발하였다. 생체 모방학을 활용하여 새로운 형태의 로봇 손에 대한 개념을 도출하였다. 손가락과 손목은 인체 팔의 근골격에 분석을 통하여 상박에 설치된 와이어와 액추에이터에 의하여 구동된다. DC 모터에 의해 구동되는 스크류-너트 매커니즘을 통하여 구동 케이블에 높은 장력을 발생시킨다. 파지력의 쉬운 제어를 위하여 스크류-너트 메커니즘에 조합 스프링을 적용하였다. 첫 번째 설계에서 손가락 제어 문제, 손가락과 손목 운동의 간섭 문제가 발견되었다. 트리즈의 모순 분석을 통하여 이러한 문제에 대한 해결안을 도출하였다. 두 번째 설계에 대하여 다양한 형태와 무게의 물체에 관하여 파지와 동작 테스트를 시행하였다.

3자유도 암 로봇의 가상시뮬레이션과 실체궤적 (A Virtual Simulation and Real Trajectory of 3-DOF Arm Robot)

  • 문진수;김철우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.300-305
    • /
    • 2007
  • This study developed a human robot master arm, which has a structure similar to the human arm, with the object of taking over human works. The robot arm was structured to reproduce human actions using three axes on each of the shoulder and the wrist based on mechanics, and the actuator of each axis adopted an ordinary DC motor. The servo system of the actuator is a one body type employing an amp for electric power, and it was designed to be small and lightweight for easy installation. We examined the posture control characteristics of the developed robot master arm in order to test its interlocking, continuous notions and reliability.

  • PDF

External Force Control for Two Dimensional Contour Following ; Part 1. A Linear Control Approach

  • Park, Young-Chil;Kim, Sungkwun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.130-134
    • /
    • 1992
  • The ability of a robot system to comply to an environment via the control of tool-environment interaction force is of vital for the successful task accomplishment in many robot application. This paper presents the implementation of external force control for two dimensional contour following task using a commercial robot system. Force accommodation is used since a constraint imposed in our work is not to modify the commercial robot system. A linear, decoupled model of two dimensional contour following system in the discrete time domain is derived first. Then the experimental verification of linear control is obtained using a PUMA 560 manipulator with standard Unimation controller, Astek FS6-120A six axis wrist force sensor attached externally to the arm and LSI-11173 microcomputer. Experimentally obtained data shows that the RMS contact force error is 0.8246 N when following the straight edge and 2.3768 N when following 40 mm radius curved contour.

  • PDF

상지 외골격 로봇 제어를 위한 인체 팔 동작의 기구학 및 동역학적 분석 - 파트 1: 시스템 모델 및 기구학적 제한 (Analysis on Kinematics and Dynamics of Human Arm Movement Toward Upper Limb Exoskeleton Robot Control Part 1: System Model and Kinematic Constraint)

  • 김현철;이춘영
    • 제어로봇시스템학회논문지
    • /
    • 제18권12호
    • /
    • pp.1106-1114
    • /
    • 2012
  • To achieve synchronized motion between a wearable robot and a human user, the redundancy must be resolved in the same manner by both systems. According to the seven DOF (Degrees of Freedom) human arm model composed of the shoulder, elbow, and wrist joints, positioning and orientating the wrist in space is a task requiring only six DOFs. Due to this redundancy, a given task can be completed by multiple arm configurations, and thus there exists no unique mathematical solution to the inverse kinematics. This paper presents analysis on the kinematic and dynamic aspect of the human arm movement and their effect on the redundancy resolution of the human arm based on a seven DOF manipulator model. The redundancy of the arm is expressed mathematically by defining the swivel angle. The final form of swivel angle can be represented as a linear combination of two different swivel angles achieved by optimizing different cost functions based on kinematic and dynamic criteria. The kinematic criterion is to maximize the projection of the longest principal axis of the manipulability ellipsoid for the human arm on the vector connecting the wrist and the virtual target on the head region. The dynamic criterion is to minimize the mechanical work done in the joint space for each two consecutive points along the task space trajectory. As a first step, the redundancy based on the kinematic criterion will be thoroughly studied based on the motion capture data analysis. Experimental results indicate that by using the proposed redundancy resolution criterion in the kinematic level, error between the predicted and the actual swivel angle acquired from the motor control system is less than five degrees.

인간형 로봇을 위한 6축 힘/모멘트센서 개발 (Development of 6-axis force/moment sensor for a humonoid robot)

  • 김갑순;신희준
    • 센서학회지
    • /
    • 제16권3호
    • /
    • pp.211-219
    • /
    • 2007
  • This paper describes the development of 6-axis force/moment sensor for a humanoid robot. In order to walk on uneven terrain safely, the robot's foot should perceive the applied forces Fx, Fy, Fz and moments Mx, My, Mz to itself, and be controlled by the foot using the forces and moments. Also, in order to grasp unknown object safely, the robot's hand should perceive the weight of the object using the mounted 6-axis force/moment sensor to its wrist, and be controlled by the hand using the forces and moments. Therefore, 6-axis force/moment sensor should be necessary for a humanoid robot's hand and foot. In this paper, 6-axis force/moment sensor for a humanoid robot was developed using many PPBs (parallel plate-beams). The structure of the sensor was newly modeled, and the sensing element of the sensor was designed using theoretical analysis. Then, 6-axis force/moment sensor was fabricated by attaching strain-gages on the sensing elements, and the characteristic test of the developed sensor was carried out. The rated outputs from theoretical analysis agree well with the results from the experiments.

Wearable Robot Arm의 제작 및 제어 (Design and Control of a Wearable Robot)

  • 정연구;김윤경;김경환;박종오
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.277-282
    • /
    • 2001
  • As human-friendly robot techniques improve, the concept of the wearability of robotic arms becomes important. A master arm that detects human arm motion and provides virtual forces to the operator is an embodied concept of a wearable robotic arm. In this study, we design a 7 DOF wearable robotic arm with high joint torques. An operator wearing this robotic arm can move around freely because this robotic arm was designed to have its fixed point at the shoulder part of the operator. The proposed robotic arm uses parallel mechanisms at the shoulder part and the wrist part on the model of the human muscular structure of an upper limb. To reduce the computational load in solving the forward kinematics and to prevent singularity motions of the parallel mechanism, yawing motion of the parallel mechanisms was separated using a slip ling mechanism. The total weight of the proposed robotic arm is about 4 kg. An experimental result of force tracking test for the pneumatic control system and an application example for VR robot are described to show the validity of the robot.

  • PDF