• Title/Summary/Keyword: Road luminaires

Search Result 13, Processing Time 0.029 seconds

Development of Outdoor 50W-LED Module using Heat-pipe and Stack-fin (히트파이프 및 스택핀을 이용한 50W급 옥외용 LED 모듈개발)

  • Hong, Seok-Gi;Jeong, Hee-Suk;Ryeom, Jeong-duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.15-21
    • /
    • 2015
  • We proposed 50W-LED modules of using Heat-pipe and Stack-fin and produced LED modules was evaluated heat dissipation characteristics with comparison of the conventional die-casting type. It verified the application of products by applying it to 150W-LED road luminaires through simulation. The LED module was measures aimed design temperature of the Stack-fin and showed 26% upward heat dissipation effect than a conventional die-casting type. The luminous efficacy of 150W-LED road luminaires using this LED module reached over 112lm/W, and the simulation results showed average of horizontal luminance, overall luminance uniformity($U_O$) and lane luminance uniformity($U_I$) that is suitable for five-lane road with the KS standards.

On the Improvement for Design Methods of Luminaire Supports Based on the Structural Safety (구조안전성 기반의 가로등주 설계개선방안)

  • Jung, Soo Hyung;Shim, Jae Soo;Choi, Hyun Gyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.6
    • /
    • pp.45-55
    • /
    • 2012
  • The road luminaires have been treated as subsidiary electric apparatuses in the road although they are indispensable facilities which people use the road safely. Because of this misunderstanding, there are not many researches on luminaire supports against the wind loads. Therefore, a typhoon has overturned or damaged many luminaire supports without having sufficient structural safeties. The purpose of this study is to review the current design criteria and to suggest the improvement of design methods based on the structural safety and compatible with the site conditions of luminaire supports. The stress concentration around the inspection hole, which causes the collapse of luminaire supports, is analyzed and stress reduction method is suggested with the improved design methods.

The Study of the Most Suitable Location of Luminaire for Road Tunnel Lighting System (도로터널에서 최적의 조명기구 위치 연구)

  • 한완모;장우진;이인환
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.25-29
    • /
    • 2003
  • As we know, topography of korea is composed of many mountains Also, the volume of traffic is increasing more and more nowadays. So, many tunnels are being constructed to reduce cost of transport and time. Thus, tunnel illumination was considered as the most important thing to make safe traffic conditions. In the past, we installed luminaires on the wall in tunnel, but currently we are installing those on the ceiling. Wherever luminaires are installed on the ceiling, the electric designer may not have known the proper point to install luminaires. Therefore, we researched this project to resolve above problems with abundant experience and accurate data through simulation(Lightscape program).

  • PDF

Development of High Efficiency and High Power LED Package for Applying Silicone-Reflector (실리콘 리플렉터를 적용한 고효율 고출력 LED 패키지 개발)

  • Jeong, Hee-Suk;Lee, Young-Sik;Lee, Jung-Geun;Kang, Han-Lim;Hwang, Myung-Keun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.1-5
    • /
    • 2013
  • We developed high-efficient 6W-LED package with simple structure by applying Heat Slug and silicone-reflector. LED package was manufactured in $8.5{\times}8.5mm$ sized multi-chip structure having thickness of $500{\mu}m$ achieved by bonding silicon-reflector with prepreg on top of the plate after implementing the reflector placed on copper substrate Half Etching by thickness of $200{\mu}m$. The luminous flux, luminous efficacy, correlated color temperature, color rendering index and thermal resistance of developed LED was evaluated, and it verified the application of products by applying it to 120W-LED road luminaires through simulation. The luminous efficacy of LED package reached over 130lm/W, and it is possible to be manufactured into 120W-LED road luminaires using 18 packages. In addition, the simulation results showed average of horizontal illuminance and overall illuminance uniformity that is suitable for three-lane road.

The Study of the Most Suitable Location of Luminaire for Road Tunnel Lighting System (도로터널에서 최적의 조명기구 위치 연구)

  • 한완모;장우진;이인환
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.1-7
    • /
    • 2004
  • As we know, topography of korea is composed of many mountains. Also, the volume of traffic is increasing more and more nowadays. So, many tunnels are being constructed to reduce cost of transport and time. Thus, tunnel illumination was considered as the most important thing to make safe traffic conditions. In the past, we installed luminaires on the wall in tunnel, but currently we are installing those on the ceiling. Wherever luminaires are installed on the ceiling, the electric designer may not have known the proper point to install luminaires. Therefore, we researched this project to resolve above problems with abundant experience and accurate data through simulation(Lightscape program). As a result of research, mounting luminaires on the ceiling are better than wall because uniformity is more regular and utilization factor is also higher and then brightness is adequate as well, whereby installation on the ceiling is economical. Therefore, it is suitable that luminaires are installed on the ceiling in tunnel than wall.

Proposal of Lighting Power Density for Road Lighting (도로종류에 따른 조명전력 허용기준([W/m2]) 제안)

  • Lee, Sang-Jin;Lee, Min-Wook;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.12
    • /
    • pp.42-47
    • /
    • 2011
  • The design of road lighting is aiming illuminance and luminance requirements for road lighting. In the process, various factors associated with luminaires such as luminous efficacy, light distribution, mounting height, spacing and maintenance factor are considered. However, there has been no restriction on lighting power density. In this study, lighting power density has been comparatively analyzed through a study of related data and a result of measurements on domestic roads. And, it has been analyzed by simulation results for road in which lighting conditions are variable. In terms of the limitation on power density for road lighting, road lighting can be designed using high efficacy lighting systems for energy saving.

Design and Installations of Road Lighting for Arterial Roads to Provide the Optimal Values of Light Technical Parameters (야간의 도로조명 상황에서 최적의 도로조명기준을 나타낼 수 있는 가로등의 설계와 배치에 관한 연구)

  • 김기혁
    • Journal of Korean Society of Transportation
    • /
    • v.9 no.2
    • /
    • pp.41-56
    • /
    • 1991
  • The aim of this research is designing road lighting installations(arrangement, mounting height spacing and overhang) which produce a certain level and distribution of luminance together with minimal glare. These can be varied over a limited range for a given luminance and road surface to achieve the required installation performance. In Korea there are no code of practice which lays down recommended performance criteria (Lavg, Uo, Ul, G, TI) with practical design guidance on how to achieve them. In case study design rules and current installation of road lighting in daegu city are analysed. The core of research are suggesting a new performance criteria and providing a set of table giving the maximum lognitudinal spacing between successive luminaires. The result of this research prescribes the combination of height and spacing for various road widths and arrangements which will achieve a specified minimum performance on straigt roads for particular luminaire and a particular road surf-ace.

  • PDF

A Study on Selection Method of LED Using Lightings by Road Size (차로 크기에 따른 LED 광원 사용 가로등기구의 선정 방법 연구)

  • Jeon, Sunho;Gil, Jung-Su;Lee, Min-Wook;Yoo, Seong-Sik;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.6
    • /
    • pp.1-7
    • /
    • 2015
  • Road lighting is designed with a goal of achieving the related standards on luminance, uniformity ratio and glare. Unless the luminaire with LID which is perfect for road conditions is used, a situation which fails to meet lighting standards may occur. The study examined the relationship of maximum spacing with average road luminance and longitudinal uniformity. Based on the result of the analysis, this study evaluated luminaire with what characteristics are suitable to achieve lighting requirements of the roads and suggested methods of selection for luminaires depending on the size of the road.

Secondary Optics Design of Dissymmetrical Light Distribution for 100 W LED Safety Luminaires (100 W급 LED 보안 등기구용 비대칭 배광의 2차 렌즈 설계)

  • Shin, Ik-Tae;Yang, Jong-Kyung;Lee, Dong-Jin;Par, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.6
    • /
    • pp.471-476
    • /
    • 2010
  • This paper has studied dissymmetrical light distribution design using the secondary optics in the simulation. fundamental Lambertian radiation distribution based on LED has been cut off by the secondary optics, and the first surface slope of lens and second surface slope of total reflection area have been calculated through formula. PMMA (the index of refraction: 1.49361) which is material of lens has been selected. critical angle($42.02993^{\circ}$) between Air and PMMA has been calulated by snell's law, and total reflection angle slope has been selected about $16.67^{\circ}$ to occur the total reflection. when the first surface slope and the second surface slope has been set up, Rays of all total reflection area have generated the total reflection. finally, designed LED Module has been estimated by Korean Industrial Standards for LED safety street lighting. dissymmetrical light distribution have been analyzed with reached effect of road illuminance, and average road illuminance which are each 70.6 lx, 40.35 lx, and 25.88 lx have been satisfied with Korean Industrial Standards for LED safety street lighting.

Economic Evaluation of LED Luminaires for Tunnel Interior Zones

  • Cho, Sook-Hyun;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.11
    • /
    • pp.7-13
    • /
    • 2013
  • There has been a need for the systematic evaluation of the economic efficiency between conventional fluorescent lamp lighting systems that have been used in tunnels and LED lighting systems. This study has evaluated basic tunnel lighting between the conventional fluorescent lighting systems and the LED lighting system using the evaluation tool of tunnel lighting by Life Cycle Cost (LCC) and using the economic efficiency evaluation method. In addition, the unit discount rate of the LED lighting system and the estimated increase in the price of electricity have made the estimated cost of LCC the same if two luminaires were used in the basic part of the tunnel.