• Title/Summary/Keyword: Road capacity

Search Result 454, Processing Time 0.035 seconds

A Study on the Road Capacity Reduction Rate of Freeway Tunnel Section (고속도로 터널부 도로 용량 감소율에 관한 연구)

  • Sunhoon Kim;Dongmin Lee;Sooncheon Hwang
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.23 no.3
    • /
    • pp.17-28
    • /
    • 2024
  • In this study, the capacity of the tunnel and the general section was calculated and compared using the VDS detector data, and the decrease rate in capacity of the tunnel section was analyzed by tunnel type. To compare the capacity of the tunnel and the general section, the Product Limit Method (PLM) was applied to the VDS detector data. As a result of comparing the capacity of the tunnel and general section, the capacity of the tunnel section decreased by about 6.5% compared to the general section. To classify the tunnel type, the tunnel extension and the number of lanes were used as variables, and there was a difference in the decrease rate of capacity by tunnel group classified by each criterion.

Estimation of Road Capacity at Two-Lane Freeway Work Zones Considering the Rate of Heavy Vehicles (중차량 비에 따른 편도 2차로 고속도로 공사구간 도로 용량 추정)

  • Ko, Eunjeong;Kim, Hyungjoo;Park, Shin Hyoung;Jang, Kitae
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.2
    • /
    • pp.48-61
    • /
    • 2020
  • The objective of this study is to estimate traffic capacity based on the heavy-vehicle ratio in a two-lane freeway work zone where one lane is blocked by construction. For this, closed circuit television (CCTV) video data of the freeway work zone was collected, and the congestion at an upstream point was observed. The traffic volume at a downstream point was analyzed after a bottleneck was created by the blockage due to the upstream congestion. A distribution model was estimated using observed-time headway, and the road capacity was analyzed using a goodness-of-fit test. Through this process, the general capacity and an equation for capacity based on the heavy-vehicle ratio passing through the work zone were presented. Capacity was estimated to be 1,181~1,422 passenger cars per hour per lane (pcphpl) at Yeongdong, and 1,475~1,589pcphpl at Jungbu Naeryuk. As the ratio of heavy vehicles increased, capacity gradually decreased. These findings can contribute to the proper capacity estimation and efficient traffic operation and management for two-lane freeway work zones that block one lane due to a work zone.

A Study on Model Development of Pedestrian Crossing Capacity at Unsignalized Crosswalks with Pedestrian Refuge Area (중앙분리대 대기공간이 있는 비신호 횡단보도에서의 보행자 횡단용량 모형식 개발)

  • 김상구
    • Journal of Korean Society of Transportation
    • /
    • v.21 no.4
    • /
    • pp.103-111
    • /
    • 2003
  • This study proposes methodology deterimining a basic pedestrian crossing capacity that plays a critical role in the installation of pedestrian signal at the crosswalks. The methodology is based on the pattern of vehicle arrived at the crosswalks. Erlang distribuion is used as headway distribution that can cover the various levels of flow rate. Models using Erlang distribution are represented by Erlang parameter (K) of 1, 2, or 3 at 2-, 4-, or 6-lane roadway in both directions. In addition, this study considered the only type of road with a pedestrian refuge area in the median that is used to wait for the allowable gap provided by the flow of another direction. As a result, the pedestrian capacity decreases as flow rate increases and Erlang parameter increases for the road with the pedestrian refuge. This study develops the models to determine the pedestrian capacity under a variety of flow rates and the outcomes of this study could be used as the criteria for the determination of the installation of pedestrian signal or for the provision of pedestrian refuge in the median of road.

A Study on the Development of a Route Capacity Calculation Model for Improving Railway Operation Efficiency (철도 운행효율성 향상을 위한 노선용량 산정모형 개발에 관한 연구)

  • Kim, Bong-Jun;Kim, Si-gon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.1
    • /
    • pp.75-83
    • /
    • 2021
  • Over-urbanization has contributed to the increase in traffic problems. This makes the need for effective road planning and design more important than ever. I have been able to learn how to build a new road, and how to use it. However, in spite of the importance of good road planning, there are no systematic standards or methods for calculating traffic volume on railroad routes. Therefore, in this study, to strengthen the competitiveness of railroads, the concept of line capacity is introduced to railroads, and a clear standard and method for calculating railroad line capacity are presented. Based on the results, the line capacity of main railway lines for domestic railways was calculated. By applying the method of calculating the line capacity presented in this study, the capacity of existing railway lines and newly expanded routes can be calculated. It is expected that our findings will be able to provide systematic standards that can be applied to yield a more effective investment and design planning stage; the findings will also help improve the efficiency of railroad operation.

Development of Adjustment Factors under Day and Night Conditions for Freeway Capacity to Improve Traffic Safety (교통안전 향상을 위한 주야 변화에 따른 고속도로 용량 보정계수 개발에 관한 연구)

  • Kim, Young Sun;Lee, Sang Soo
    • International Journal of Highway Engineering
    • /
    • v.17 no.4
    • /
    • pp.107-115
    • /
    • 2015
  • PURPOSES: This study analyzes the characteristics of traffic flow on freeway sections under daytime and nighttime conditions to improve traffic safety, and suggests a method to estimate an accurate freeway capacity value that reflects these characteristics. METHODS : The trends and differences in capacity were investigated using comprehensive field data collected under both daytime and nighttime conditions on freeway sections with designated speeds of 80, 100, and 120 kph. RESULTS : The capacity values under nighttime driving conditions were reduced by 3.3%, 6.9%, and 8.8% at 80, 100, and 120 kph, respectively. Several nighttime adjustment factors were deduced for each designated speed category from the analysis results. CONCLUSIONS : It is expected that more accurate capacity values can be estimated for freeway sections under nighttime conditions by applying the resulting adjustment factors. In addition, traffic safety will be improved through the increased efficiency of traffic management on these freeway sections.

A Study on Level-of-Service Changes of Expressway in Accordance with the Revision of Traffic Capacity at Work-Zone (교통용량 개정에 따른 고속도로 공사구간의 서비스 수준에 대한 연구)

  • Ryu, SungWoo;Park, Kwon-Jea;Han, SeungHwan;Cho, Yoon-Ho
    • International Journal of Highway Engineering
    • /
    • v.16 no.3
    • /
    • pp.109-117
    • /
    • 2014
  • PURPOSES : This study analyzes the available working time at work-zone on the Expressway in accordance to the new capacity manual. METHODS : Sensitivity analysis on variables were conducted to calculate the adjusted capacity at work-zone based on previous researches. RESULTS : The main factors which affect available working time at the work-zone were its capacity, number of lanes, terrain and lane width. Other factors have minimal effect on the available working time. Based on the analysis, a calendar of lane closures was suggested. CONCLUSIONS : A series of studies concluded that the capacity at work-zone in the new capacity manual reduced to 76-82% of the existing manual. As such, the available working time decreased. Furthermore, the factors affecting the available working time needs to be considered when making a plan to rehabilitate the distressed pavement.

Minimum Thickness of Long-Span RC Deck Slabs for 2-girder Bridges Designed by 80 MPa Concrete (80 MPa급 고강도 콘크리트를 활용한 2거더교 RC 장지간 바닥판의 최소두께)

  • Bae, Jae-Hyun;Yoo, Dong-Min;Hwang, Hoon-Hee;Kim, Sung-Tae
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.97-103
    • /
    • 2014
  • To ensure durability and light weight of bridges, high-strength concrete is required for long-span deck slabs. Such a technology eventually extends the life of bridges and improves the economic efficiency. The results of this study suggests a formula for calculating the minimum thickness of long-span deck slabs built with high strength concrete. The minimum thickness is proposed based on the limit states indicated in the CEB-FIP Model Code and the Korean Highway Bridge Design Code(limit state design). The design compressive strength of concrete used for the study is 80MPa. Moreover, the required thickness for satisfying the flexural capacity and limiting deflection is estimated considering the limit state load combination. The formula for minimum thickness of deck slabs is proposed considering the ultimate limit state(ULS) and the serviceability limit state(SLS) of bridges, and by comparing the Korean Highway Bridge Design Code and similar previous studies. According to the research finding, the minimum thickness of long-span deck slab is more influenced by deflection limit than flexural capacity.

A study on the anti-freezing of light weight electric traction system testing road (경량전철 시스템 선로 결빙방지에 관한 연구)

  • Woo, Jae-Ho;Han, Kyu-Il;Kim, Jong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2256-2261
    • /
    • 2008
  • The electric snow melting and deicing system by electric heating cable which is adopted in this study is a part of road facilities to keep surface temperature of the road higher than freezing point of water for melting the snow or ice accumulated on it. The electric heating cables are buried under paved road at a certain depth and a certain pitch and operated automatically and manually. Design theory, amount of heating, and installation standard vary according to economic situation, weather condition, and installation place. A main purpose of this study is figuring out the appropriate range of required heat capacity and installation depth and pitches for solving snowdrifts and freezing problems with minimum electric power consumption. This study was performed under the ambient air temperature($-2^{\circ}C$, $-5^{\circ}C$), the pitches of the electric heating cables (200 mm, 300 mm), heating value ($250\;W/m^2$, $300\;W/m^2$, $350\;W/m^2$).

  • PDF

A Study on Highway Capacity Variation According to Snowfall Intensity (강설에 따른 고속도로 용량 변화에 관한 연구)

  • Son, Young Tae;Lee, Sang Hwa;Im, Ji Hee
    • Journal of Korean Society of Transportation
    • /
    • v.31 no.6
    • /
    • pp.3-11
    • /
    • 2013
  • Under the consumption of bad weather situation affects traffic flows, the study scope is focused on highway capacity and speed variations among other highway traffic flow characteristic changes according to snowfall density. Thus, this study carried out through the data collection and statistical analysis by focusing on capacity and speed changes. Traffic volume, speed and density were selected as factors to explain the property change of a traffic flow for analysis, and 7 basic sections such as 3 highways in Gyeonggi-do and 4 highways near the meteorological observatory were selected as survey points for data collection. Snowfall levels were classified into 3 steps(Light, Medium, Heavy Snow) to analyze the capacity change by snowfall levels. As a result of analysis, the change of capacity depending on snowfall levels decreased 13.2% in case of light snow compared to a good weather, 18.6% in case of medium snow and 32.0% in case of heavy snow, so the capacity reduction rate increased as the snowfall level increased. The worsening weather appeared to have a very big possibility to act as a factor to reduce the operational efficiency of a road, so a road design and operation method considering this should be presented in the future.

Nonlinear aerostatic stability analysis of Hutong cable-stayed rail-cum-road bridge

  • Xu, Man;Guo, Weiwei;Xia, He;Li, Kebing
    • Wind and Structures
    • /
    • v.23 no.6
    • /
    • pp.485-503
    • /
    • 2016
  • To investigate the nonlinear aerostatic stability of the Hutong cable-stayed rail-cum-road bridge with ultra-kilometer main span, a FEM bridge model is established. The tri-component wind loads and geometric nonlinearity are taken into consideration and discussed for the influence of nonlinear parameters and factors on bridge resistant capacity of aerostatic instability. The results show that the effect of initial wind attack-angle is significant for the aerostatic stability analysis of the bridge. The geometric nonlinearities of the bridge are of considerable importance in the analysis, especially the effect of cable sag. The instable mechanism of the Hutong Bridge with a steel truss girder is the spatial combination of vertical bending and torsion with large lateral bending displacement. The design wind velocity is much lower than the static instability wind velocity, and the structural aerostatic resistance capacity can meet the requirement.