• 제목/요약/키워드: Riverbed Filtration

검색결과 18건 처리시간 0.024초

강변여과수(충적층 및 하상)를 이용한 냉방시스템 설치 및 모니터링 (Installation and Monitoring of Bankfiltration (including alluvial and riverbed deposits) Source Heat Pump Cooling System)

  • 정우성;황기섭;안영섭
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.5-8
    • /
    • 2006
  • The Alternative energy has lately attracted considerable attention due to the high oil price and environment problem. In this study, pilot test facility for using the geothermal energy source from riverbank filtration was constructed and monitoring devices are installed to estimate the efficiency of this system. Initial installation cost can be saved efficiently by connect ing a heat pump system into the exist ing pumping well in Changwon riverbank filtration site. One set of monitoring results during summer was presented and analyzed.

  • PDF

A KINETIC ANALYSIS OF ORGANIC RELEASE FROM THE AQUIFER SOIL IN RIVERBANK/BED FILTRATION

  • Ahn, Kyu-Hong;Moon, Hyung-Joon;Kim, Seung-Hyun
    • Environmental Engineering Research
    • /
    • 제10권4호
    • /
    • pp.199-204
    • /
    • 2005
  • Experiments were performed to estimate the organic release from the aquifer soil in riverbank and/or riverbed filtration via a kinetic approach. Organic release was assumed as a reaction of first order regarding concentrations in both soil and water phases. The reaction rate constants were obtained by comparing the model predictions with the experimental data of organic release reaction and the equilibrium distribution of organic matter between water and soil phases. Results show that the organic release from the aquifer soil was not negligible under normal conditions in Korea reaching 4.7mg-COD/L-day. This indicates that manganese and iron start to be released from aquifer soil in the riverbank filtration in the middle reach of the Nakdong river if the travel time of the filtrate exceeds about 5 days. It was also seen that the COD of the soil organic matter was 0.89mg-COD/mg-OM and that 65% of the COD was BOD5.

지구화학적 해석을 이용한 하상여과 설계인자에 대한 연구 (Design Parameters of Riverbed Filtration Estimated from Geochemical Data)

  • 조강희;김봉주;안중혁;임기성;최낙철;박천영
    • 지질공학
    • /
    • 제23권4호
    • /
    • pp.493-502
    • /
    • 2013
  • 본 연구는 하천수와 지하수에 대해 지구화학적 해석을 이용하여 하상여과의 설계인자에 대해 조사하였다. 연구지역은 충적층으로 구성되어 있으며, 지표환경의 비점오염원 영향을 쉽게 받을 뿐만 아니라, 하상여과 설계인자에 영향을 미칠 것으로판단된다. 하천흐름에 따라 하천수는 상류, 중류, 하류 3개 시료를 채취하였고, 하천으로부터 거리에 따라 지하수 9개 시료를 각각 채취하였다. 연구지역의 시료에 대한 화학분석자료를 통하여, 산업시설과 농업활동이 일차적인 오염원임을 추정하였다. 또한, 배경수질은 Ca-Na-$HCO_3$, Ca-Cl, Ca-$HCO_3$-Cl 유형을 보인다. 연구지역의 하상여과 설계인자는 K, $HCO_3$, $NO_3$ 및 Cl로 판단된다. 질소안정동위원소를 통해 연구지역은 A, B, C그룹으로 구분되며, A그룹은 하천수의 기원 및 탈질산화반응, B그룹은 지류의 유동방향에 따른 탈질산화작용, C그룹은 인위적인 오염인 자연토양, 생활하수유래의 질산성질소로 판단된다.

강변여과에서 여과거리에 따른 페놀, 1,4-다이옥산 그리고 다이아지논의 거동에 관한 실험연구 (An Experimental Study on the Behavior of Phenol, 1,4-dioxane and Diazinon along the Travel Distance in Riverbank Filtration)

  • 최홍규;정일화;정관수;이영득;김승현
    • 대한환경공학회지
    • /
    • 제35권6호
    • /
    • pp.436-441
    • /
    • 2013
  • 복류수와 천변여과지 그리고 점차 여과거리가 짧아지고 있는 우리나라의 강변/하상여과 등이 가지는 미량오염물에 대한 저항능력을 평가하기 위하여 5 m 길이의 모래칼럼을 이용한 실험을 수행하였다. 실험결과 우리나라 하상의 토양은 유기물 함량이 상당하여 염소이온의 토양표면 흡착이 비교적 활발함 알 수 있었다. 페놀은 칼럼의 여과수에서 검출되지 않았고, 1,4-다이옥산과 다이아지논은 하상토양과 흡착반응을 일으키면서 이동하며, 2.5 m의 이동과정에서 1,4-다이옥산의 첨두농도는 유입농도의 약 40%로 그 농도가 감소하였고, 다이아지논의 첨두농도는 약 60%로 감소하는 것으로 나타났다. 실규모 설비에서는 여과거리가 5 m 보다 더 길기 때문에 첨두농도의 감소효과는 상당히 클 것으로 기대되었다.

강변여과수 시설에서의 지열에너지 활용 가능성 평가 (Assessment for geothermal energy utilization in the riverbank filtration facility)

  • 신지연;김경호;배광옥;이강근;정우성;석희준;김형수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.485-488
    • /
    • 2007
  • Riverbank filtration is a kind of artificial aquifer recharge for the fresh water supply. By construction of several production wells penetrating the riverbank, surface water withdrawn from the river would pass riverbed. This extracted water is well known to be cooler than surface water in summer and warmer than surface water in winter, showing more constant water temperature. This characteristic of extracted water is applied to geothermal energy utilization. Prediction of the annual temperature variation of filtrated water is the major concern in this study. In Daesan-myeon, Changwon-si, Gyeongsangnam-do, South Korea, riverbank filtration facility has been on its operation for municipal water supply and thermal energy utilization since 2006. Appropriate hydraulic and thermal properties were estimated for flow and heat transfer modeling with given pumping rate and location. With the calibrated material properties and boundary conditions, we numerically reproduced measured head and temperature variation with acceptable error range. In the numerical simulation, the change of saturation ratio and river stage caused by rainfall was calculated and the resulting variation of thermal capacity and thermal conductivity was considered. Simulated temperature profiles can be used to assess the possible efficiency of geothermal energy utilization using riverbank filtration facility. Influence of pumping rate, pumping location on the extracted water temperature will be studied.

  • PDF

개착식 하상여과에서 탁수를 고려한 수정 투수계수 적용 연구: 수치모델링을 통한 접근 (A study on the application of modified hydraulic conductivity to consider turbid water for open-cut riverbed infiltration process: numerical modeling approach)

  • 양정석;김일환;정재훈
    • 한국수자원학회논문집
    • /
    • 제49권9호
    • /
    • pp.741-748
    • /
    • 2016
  • 개착식 하상여과에 대해서 실험실 규모의 모형을 구축하고 중사, 왕사, 화산석, 자갈에 대한 단일 여재를 구성하였다. 실험을 통해 투수계수 및 하상 여과에 대한 취수량을 추정하고, 지하수 유동 모델링인 Visual MODFLOW를 통해 탁도 변화에 따라 수정된 투수계수를 적용하고 미치는 영향을 분석하였다. 각 여재마다 22개의 수정 투수계수 시나리오가 적용되었다. 전체 모델링에서 최소 오차는 화산석(2~5 mm)을 여재로 한 경우 상부에서부터 3개 지층에 대해서 20% 감소된 투수계수를 적용한 시나리오다. 이는 화산석의 특성상 탁도를 유발하는 황토가 여재에 흡착되어 상부에서 3번째 지층까지 영향을 미치는 것으로 추정되었다. 또한 입자의 크기가 작은 중사의 경우 5% 감소된 투수계수를 상부에서 두 번째 지층까지 적용한 시나리오에서도 작은 오차 값을 나타냈다.

수평 방사형 집수정 활용 강변여과 취수 수치 분석 (Numerical Analysis of Horizontal Collector Well in Riverbank Filtration)

  • 김형수;정재훈
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제14권1호
    • /
    • pp.1-10
    • /
    • 2009
  • 지하수 유동 수치 모사 프로그램 (FEFLOW 5.1)을 이용하여 수평 방사형 집수정 취수에 따른 강변여과 지역의 지하수 유동을 분석하였다. 양수량, 대수층 두께, 취수정과 하천 사이의 이격거리, 하천 바닥의 투수 능력(Conductance)등의 조건 변화에 따른 집수정 인접 대수층의 수위강하가 계산되었다. 이들 조건 변화에 따라 지하수위 강하는 뚜렷한 변화를 보여주었다. 민감도 분석 결과, 대수층의 두께와 취수정과 하천 사이의 이격거리가 하천 바닥의 수리 전도에 비해 지하수위 강하에 더 민감하게 영향을 주는 것으로 평가되었다. 이러한 결과는 수평 방사형 집수정을 통한 강변여과 취수 가능지역을 선정하고 그 개발량을 추정할 때, 충적 대수층의 두께와 분포 특성이 중요한 요소임을 시사한다. 또한 FEFLOW의 1차원 선형 불연속 특징 요소를 활용한 수치 모사는 효과적으로 수평 방사형 집수정의 정량 평가와 강변여과 현장의 개발 가능량 추정을 할 수 있는 도구임이 밝혀졌다.

하상여과용 다직경 수평집수관의 효능에 대한 실험연구 (An Experimental Study on the Performance of Multi-Diameter Lateral for Riverbed Filtration)

  • 배가람;김승현
    • 대한환경공학회지
    • /
    • 제34권5호
    • /
    • pp.359-364
    • /
    • 2012
  • 장대형 수평집수관은 내부에서 축방향 흐름에 대한 마찰저항으로 인해 우물효율이 낮아지므로 이를 방지하기 위하여 다직경 수평집수관을 제안하였고, 그 효능을 평가하기 위해 실험실 규모의 모래통 실험을 수행하였다. 실험에서는 다직경과 여러 직경의 단직경 집수관에 대해 산출유량을 달리하면서 집수관에서의 수두분포를 파악하였으며, 이를 통해서 집수관의 효능을 평가하였다. 연구결과 다직경 집수관은 단직경에 비해 재료비가 1/3 이상 절감되면서도 그 산출유량은 최대직경의 단직경 집수관의 93% 이상이어서 그 효능이 우수함을 알 수 있었다. 또한, 출구유속이 약 0.8 m/sec 이상에서는 수평집수관의 수두분포가 왜곡되어 수리학적으로 비효율적인 수평우물임을 알 수 있었다.