• 제목/요약/키워드: Ripple control

검색결과 823건 처리시간 0.022초

적응 Hysteresis band폭 제어 알고리즘을 이용한 Brushless DC Motor의 운전 (Operation of Brushless DC Motor using the Adaptive hysteresis bandwidth control algorithm)

  • 조계석;김광연;현동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 추계학술대회 논문집 학회본부
    • /
    • pp.171-174
    • /
    • 1991
  • Among the various PWM methods, the hysteresis-band current control PWM method is popularly used because of its simplicity of implementation, fast response characteristics and inherent peak current limiting capability. However, the current control PWM method with a fixed hysteresis-band has the disadvantage that switching frequency decreases and current ripple is high as the increasing of back-EMF. As a result, load current contains excess harmonics. This paper describes a adaptive hysteresis-bandwidth control algorithm so as to maintain the average switching frequency constant and decrease the current ripple where the hysteresis bandwidth is derived as a relation with the switching frequency. This control algorithm is applied to the surface-type brushless DC motor with separated winding and using the computer simulation, the validity of its algorithm is proved.

  • PDF

청소기용 단상 SRM의 PWM/PDM 운전 기법 비교 고찰에 관한 연구 (A Comparison of the PWM/PDM Control Scheme for Single Phase Switched Reluctance Motor for Vacuum Cleaner)

  • 이요한;김상영;임준영;김정철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.419-422
    • /
    • 2002
  • This paper compares PDM and PWM for single phase switched reluctance motor for vacuum cleaner. Generally, PWM control scheme Is preferred because of small torque ripple compared with PDM control scheme. However, as the motor speed of the vacuum cleaner is above 20,000[rpm], the torque ripple is not problem any more. PDM control scheme is better than PWM control scheme considering loss of power device and EMI.

  • PDF

유도 전동기 Vector제어시의 Torque Ripple 저감법에 관한 연구 (Torque Ripple Reduction Methods for Vector Controlled Induction Motor)

  • 송호신;우정인;이현우;박용주;최주석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.430-432
    • /
    • 1990
  • This paper concerns a method for high precision torque control of induction motor supplied with power via a Transister inverter. The control system is totaly digitized using DSP - TMS32010.Since operation time leads to control delay in such a system, torque ripples are more significient than relieved considerably by using current preview control and vector pulse width control. The usefulness of these techniques will be demonstrated by showing the results of a simulation,and results of measurement on a 2.2Kw induction motor.

  • PDF

Comparison of Performance of Brushless DC Drives under Direct Torque Control and PWM Current Control

  • Zhu Z. Q.;Liu Yong;Howe David
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권4호
    • /
    • pp.337-342
    • /
    • 2005
  • Direct torque control (DTC) was originally developed for induction machine drives, and, more recently has been applied to permanent magnet brushless AC (BLAC) drives. In this paper, the performance of DTC controlled brushless DC (BLDC) drives is compared with that of PWM current controlled BLDC drives, both with and without current shaping. Both simulation and experimental results are presented, as well as the analysis of the resulting torque waveforms. It is shown that, in addition to exhibiting a fast torque response, a DTC controlled BLDC drive has a significantly lower low-frequency torque ripple than the PWM current controlled BLDC drive without current shaping, and that it is easier to implement than PWM current control with current shaping.

A Sliding Mode Control Design based on the Reaching Law for Matrix Rectifiers

  • Wang, Zhiping;Mao, Yunshou;Hu, Zhanhu;Xie, Yunxiang
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1122-1130
    • /
    • 2016
  • This paper presents a novel approach for achieving both a tight DC voltage regulation and a power factor control by applying the Reaching Law Sliding Mode Control (RL-SMC) and the conventional Sliding Mode Control (SMC). Applying these strategies on a matrix rectifier (MR) can achieve a unity grid side power factor when the DC load changes widely and it can provide a ripple-free output voltage that is easily affected by distortions of the three-phase ac voltage supply. Furthermore, by employing the reaching law on the SMC can solve the chatting problem of the sliding motion. Comparative Matlab simulations and experimental verifications for these strategies have been presented and discussed in this paper. The results show that by applying the SMC and RL-SMC on a MR can achieve a unity grid side power factor and a regulated ripple-free DC output.

${\mu}$-controller를 이용한 PLL방식 SRM의 구동특성 (Driving characteristics of SRM with PLL using ${\mu}$-controller)

  • 표성영;안진우;이일천;황영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.25-27
    • /
    • 1998
  • The switched reluctance motor(SRM) drive system provides a good adjustable speed and torque characteristics. However, it also has some drawbacks such as relatively high torque ripple and acoustic noise which are caused by the torque production mechanism. To reduce torque ripple and to have precise speed control, PLL technique is adopted. The PLL system in conjunction with dynamic dwell angle control scheme has good speed regulation characteristics. Digital control system with a 80c196kc micro-controller is used to be realized this drive system. Test results show that the suggested control system has the ability of dynamic and precise speed control.

  • PDF

최소 차원 상태 관측기를 사용한 전류 제어형 PWM 인버터에 관한 연구 (Current Controlled PWM Inverter Using Reduced-Order State Observer)

  • 김종석;이채동;박욱상;최선영;김영철;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.300-302
    • /
    • 1995
  • This paper describes a current control method for a single-phase PWM inverter. The proposed PWM inverter utilizes the instantaneous control method which is based on the real-time digital feedback control and the microprocessor-based deadbeat control. For the deadbeat current controller, the system's order becomes a high order and increases computation delay time. Therefore, The delay time produces current ripple. To minimize the current ripple, a new method based on deadbeat control theory for current regulation is proposed. It is constructed by a reduced-order state observer which predicts the output current in next sampling instant.

  • PDF

SPMSM 인덕턴스 돌극성에 의한 전류리플 저감을 위한 PSO 알고리즘 기반의 H 전류 제어기 설계 (Design of the H Current Controller Based on the PSO Algorithm for Reducing the Current Ripple Caused by the Saliencies of SPMSM)

  • 이관형;전찬영;임동진
    • 전기학회논문지
    • /
    • 제62권10호
    • /
    • pp.1425-1435
    • /
    • 2013
  • The useful method for determining parameters of weighting functions used to design the $H_{\infty}$ current controller for attenuating the current ripple due to saliencies which SPMSM(Surface Permanent Magnet Synchronous Motor) also incorporates is described. To analyze the effect, the current ripple due to the structural and the saturation saliencies, the SPMSM model with nonlinear inductance function depending on the two independent variables, rotor position and stator current is simulated. After analysis, parameters of the weighting functions for $H_{\infty}$ current controller is selected to satisfy the robust stability, robust performance and specific performance in time and frequency domain by using the PSO(Particle Swarm Optimization) algorithm in the linear SPMSM model. Especially, the robust performance is proved that the selected weighting functions play a role in reducing the current ripple caused by the saliencies of SPMSM at the desired frequency range by the simple experiment.

팽창 공명기형 맥동 감쇠기의 임피던스 특성(유압용 피스톤 펌프의 유량.압력맥동 감쇠) (Impedance Characteristics of an Expansion-Resonator Type Pulsation Attenuator(Attenuation on Flow and Pressure Ripple form a Hydraulic Piston Pump))

  • 이상기
    • 한국생산제조학회지
    • /
    • 제9권1호
    • /
    • pp.88-95
    • /
    • 2000
  • In this paper, an expansion-resonator type pulsation attenuator is proposed to absorb and attenuate flow an pressure ripple with high frequencies generated from hydraulic control systems. The basic principle of a pulsation attenuator proposed here is applied to propagation, reflection, absorption of pressure waves at the cross section of discontinuity and resonance in the pipeline. It has advantage of the compact size and high degree fo freedom for installation in hydraulic systems. The design scheme based on distributed parameter pipeline system with dissipative viscous compressible model is developed. To investigate the reduction of flow and pressure ripple with high frequencies produced by swash plate type axial piston pump, two kinds of attenuators are manufactured. It is experimently confirmed that the spectral intensity of flow and pressure ripple with high frequencies from the pump are reduced up to about 20$^{\circ}$~30dB by using attenuators proposed here. The calculated results were in good agreement with the measured values. From there sults of this study, it is shown that an expansion-resonator type pulsation attenuator is effective in a wide frequency ranges to attenuate the flow and pressure ripple from hydraulic components.

  • PDF

제어 방식에 따른 20 W급 LED Converter 설계 및 분석 (Design and Analysis of 20 W Class LED Converter Considering Its Control Method)

  • 정영기;김성현;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제25권1호
    • /
    • pp.53-57
    • /
    • 2012
  • In this paper, by designing 20 W class driving circuit for driving high-power LED (Light Emitting Diode), we are going to comparatively carry out the analysis of characteristics for power circuit according to each design method. In this case, 200 V 60 Hz was performed as input data. The electrical characteristics such as voltage, current and ripple are checked for constant current circuit and constant voltage circuit in the LED module. In addition, as the ripple has an influence on illumination of LED light, low temperature working (-20 [$^{\circ}C$]) and high temperature working(80 [$^{\circ}C$]) are measured to make sure the ripple characteristics in accordance with temperature. In low temperature operation -20 [$^{\circ}C$] measurements, both constant current circuit and constant-voltage circuit were less impacted on input fluctuation, whereas in the high temperature operation 80 [$^{\circ}C$], current voltage in constant voltage circuit was surge after 430 [hour]. Voltage current ripple of constant current circuit was much less than constant voltage circuit, therefore we can show that constant current circuit is more stable.