• 제목/요약/키워드: Ripple control

검색결과 823건 처리시간 0.026초

인버터식 X선장치의 관전압 맥동율 개선에 관한 연구 (A Study on the Improvement of ripple factor tube voltage waveforms in inverter type X-ray generator)

  • 이성길;임홍우;조금배;정수복;백형래
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.234-238
    • /
    • 1999
  • In order to radiate X-ray, the low ripple stabilized high voltage DC over the range of 40KV to 150KV is directly inflicted to X-ray tube. The energy characteristics of the radiated X-ray depend on the pulsating waveforms of the DC voltage supplied X-ray tube. In general, the low ripple voltage waveforms with fast rising times are required to increase with the dosage per unit time lest the exposure time should be longer in orde that the motion artifacts of an object may be eliminated in actual. The conventional types of X-ray generators were bulky in physical size and heavy in weight, and the control accuracies of the output voltages were not always satisfactory. The high frequency switching inverter and converter technology on power conversion and control systems have been greatly closed up introducing new power semiconductor devices. To decreasing the volume and the weight of high voltage transformer, and to stabilize ripple, a high frequency PWM inverter is connected between DC source and high voltage transformer. This paper describes the output characteristics according to stabilize ripple of X-ray tube voltage and compared the reproducibility, direcibility and doesage.

  • PDF

유한요소 해석에 의한 영구자석형 선형 동기전동기의 제어특성 개선 (Improvement of Control Characteristics of Permanent Magnet Linear Synchronous Motor by Finite Element Analysis)

  • 정인성;현동석
    • 전력전자학회논문지
    • /
    • 제4권4호
    • /
    • pp.318-324
    • /
    • 1999
  • 본 논문에서는 영구자석형 선형 동기전동기의 제어특성을 개선시키기 위하여 유한요소 해석에 근거한 제어기법을 제시하였다. 제시한 제어기법에서는 이동자의 위치에 따라 통상의 제어기법에서의 전류분에 추가적인 보상분 전류가 추가되게 된다. 이동자의 위치 및 인가전류에 따른 영구자석형 선형 동기전동기의 추력리플 특성이 유한요소법을 이용하여 해석되었으며, 그 결과를 토대로하여 제어시의 코깅력에 의한 추력 리플을 보상하기 위한 전류값이 계산되었다. 속도제어시 종래의 제어법과 제시된 제어법에 따른 응답특성을 살펴 보았으며, 제시된 방법의 타당성을 검증하기 위하여 시험기를 제작, 실험하였다.

  • PDF

Phase Advance Control to Reduce Torque Ripple of Brush-less DC Motor According to Winding Connection, Wye and Delta

  • Lee, Tae-Yong;Song, Jun-Young;Kim, Jaehong;Kim, Yong-Jae;Jung, Sang-Yong;Je, Jung-Moon
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.2201-2208
    • /
    • 2014
  • In this research, the characteristics of Brush-less DC (BLDC) motor in accordance with winding connection method, both Y-connection and D -connection, has been identified with design methodology simply. BLDC motor has been designed for both winding connections, and their torque analysis has been performed considering ideal current source analysis and voltage source analysis with 6-step control. In addition, to reduce torque ripple of BLDC motor, caused by coil inductance, on voltage source analysis with 6-step control, we have proposed suitable control method which is Phase Advance Control. It is verified that the torque ripple has been decreased by virtue of phase advance control, advancing and widening conduction angle of switching, via performance analysis by Finite Element Analysis.

Novel PWM Method with Low Ripple Current for Position Control Applications of BLDC Motors

  • Kim, Hag-Wone;Shin, Hee-Keun;Mok, Hyung-Soo;Lee, Yong-Kyun;Cho, Kwan-Yuhl
    • Journal of Power Electronics
    • /
    • 제11권5호
    • /
    • pp.726-733
    • /
    • 2011
  • BLDC Motors are widely used in various speed control applications due to their ease of control and low cost. Generally, the unipolar PWM method is used for speed control applications. However, the unipolar PWM method has a current spike problem in the braking operation which can be a problem in speed reversal which generally happens in position control applications. However, the current spike problem can be solved by the conventional bipolar PWM method. Although the current spike problem can be solved, the conventional bipolar PWM method has the problem of a large current ripple. In this paper, a novel bipolar PWM method is proposed to solve this problem. The current ripple and the current spike problems are analyzed in this paper for the unipolar and bipolar PWM methods. At last, the merits of the proposed bipolar PWM method are proven by experiment.

왜곡된 역기전력을 갖는 매입형 영구자석 동기전동기의 쇄교자속 고조파 관측기를 이용한 토크리플 저감 (Torque Ripple Reduction based on Flux Linkage Harmonics Observer for an Interior PM Synchronous Motor including Back EMF Harmonics)

  • 진용신;김학원;조관열;임병국
    • 전력전자학회논문지
    • /
    • 제18권4호
    • /
    • pp.367-375
    • /
    • 2013
  • The mechanical vibration of a PM synchronous motor at low speeds due to the back emf harmonics may be serious problems in some application such as MDPS(Motor driven power steering), electric vehicles. In this paper, torque ripple reduction for an interior PM synchronous motor including back emf harmonics is proposed. The dq flux linkage harmonics of the permanent magnet are estimated on real time by using the dq currents of the real system and the model of the MRAS observer. Based on the estimated flux linkage harmonics, the dq harmonic currents for reducing the torque ripples are compensated on the dq reference currents. The estimation of the flux linkage harmonics by the MRAS observer and the torque ripple reduction of the proposed algorithm was verified by the simulation and experiment.

피드포워드를 이용한 속도리플 자동 보상 알고리즘 (Automatic Velocity Ripple Compensation Algorithm by Feedforward Control)

  • 한지희;김정한
    • 한국정밀공학회지
    • /
    • 제30권9호
    • /
    • pp.951-959
    • /
    • 2013
  • In order to improve the speed performance of the direct drive mechanical systems, a comprehensive analysis of the velocity ripples of blushless DC motors should be required. Every motor has a certain level of torque ripples when it generates power, and the generated torque ripple also makes the velocity ripples in the final output stage in speed control system. In this paper, a novel algorithm for reducing velocity ripples is proposed based on the modeling of torque ripples for BLDC motors. Various algorithms have been made for torque ripples, but usually they should be installed inside the amplifier logic, result in the difficulties of flexibility for various kinds of torque ripples. The proposed algorithm was developed for being ported in the controller not the amplifier, and it has the capability of the automatic compensation adjustment. The performance of the proposed algorithm was verified by effective simulations and experiments.

Optimal Voltage Vector Selection Method for Torque Ripple Reduction in the Direct Torque Control of Five-phase Induction Motors

  • Kang, Seong-Yun;Shin, Hye Ung;Park, Sung-Min;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제17권5호
    • /
    • pp.1203-1210
    • /
    • 2017
  • This paper presents an improved switching selection method for the direct torque control (DTC) of five-phase induction motors (IMs). The proposed method is conducted using optimal switching selection. A five-phase inverter has 32 voltage vectors which are divided into 30 nonzero voltage vectors and two zero voltage vectors. The magnitudes of the voltage vectors consist of large, medium, and small voltage vectors. In addition, these vectors are related to the torque response and torque ripple. When a large voltage vector is selected in a drive system, the torque response time decreases with an increased torque ripple. On the other hand, when a small voltage vector is selected, the torque response time and torque ripple increase. As a result, this paper proposes an optimal voltage vector selection method for improved DTC of a five-phase induction machine depending on the situation. Simulation and experimental results verify the effectiveness of the proposed control algorithm.

A High-Efficiency, Auto Mode-Hop, Variable-Voltage, Ripple Control Buck Converter

  • Rokhsat-Yazdi, Ehsan;Afzali-Kusha, Ali;Pedram, Massoud
    • Journal of Power Electronics
    • /
    • 제10권2호
    • /
    • pp.115-124
    • /
    • 2010
  • In this paper, a simple yet efficient auto mode-hop ripple control structure for buck converters with light load operation enhancement is proposed. The converter, which operates under a wide range of input and output voltages, makes use of a state-dependent hysteretic comparator. Depending on the output current, the converter automatically changes the operating mode. This improves the efficiency and reduces the output voltage ripple for a wide range of output currents for given input and output voltages. The sensitivity of the output voltage to the circuit elements is less than 14%, which is seven times lower than that for conventional converters. To assess the efficiency of the proposed converter, it is designed and implemented with commercially available components. The converter provides an output voltage in the range of 0.9V to 31V for load currents of up to 3A when the input voltage is in the range of 5V to 32V. Analytical design expressions which model the operation of the converter are also presented. This circuit can be implemented easily in a single chip with an external inductor and capacitor for both fixed and variable output voltage applications.

불연속 전류모드로 동작하는 Interleaved 승압형 역률보상 컨버터의 입력전류 리플개선 (Input Current Ripple Improvement on Interleaved Boost Power Factor Corrector Operating in Discontinuous Current Mode)

  • 허태원;박지호;노태균;김동완;박한석;우정인
    • 조명전기설비학회논문지
    • /
    • 제17권1호
    • /
    • pp.116-123
    • /
    • 2003
  • 본 논문에서는 SMPS의 교류 입력측 역률을 개선시킬 수 있는 전치 레귤레이터로서 interleaved 승압형 컨버터를 관하여 연구하였다. Interleaved 승압형 역률보상 컨버터(IBPFC)는 입력전류를 두 개의 스위칭 소자에 의하여 50%씩 나누어져 흐르게 함으로써, 내부 전류제어 루프 얼이 전압제어 루프만으로 제어계를 구성하여 입력전류 리플을 줄일 수 있다. 즉, IBPFC를 구성하는 각각의 부스트 컨버터 cell을 불연속 전류모드로 동작시키더라도 전체적인 입력전류의 파형은 연속이 되어 입력전류 리플이 감소하게 된다. 불연속 전류모드로 동작하는 IBPFC를 해석하기 위하여 스위칭 상태에 따라서 6개의 모드로 구분하여 상태방정식을 구하였다. 또한, 각 상태방정식을 상태공간 평균화법을 이용하여 모델링하고, 미소변동분을 고려한 소신호 해석을 통하여 제어전달함수를 구할 수 있다. 또한, 제어전달함수를 이용하여 단일 전압제어 루프를 가지는 제어계를 설계하였으며, 이러한 해석 및 설계를 바탕으로 실험을 통하여 IBPFC의 역률개선 및 리플저감을 확인하였다.

차광, 저온 및 지베렐린 처리가 Azalea의 개화에 미치는 영향 (Effects of Shading, Chilling and Gibberellin Treatments on the Flowering of Azalea (Rhododendron spp.))

  • 정해준;유봉식
    • 자연과학논문집
    • /
    • 제10권1호
    • /
    • pp.63-71
    • /
    • 1998
  • Azalea의 개화조절을 위하여 차광, 저온 및 지베레린을 처리한 결과는 다음과 같다. 차광처리에 따른 개화반응에 있어서 차광을 많이 할수록 공시품종 모두 개화기간이 연장되었고 개화수는 증가하였다. 또한 개화소요일수는 'Ripple'에서만 증가되었으며 나머지 2품종은 비슷하였다. 저온처리는 'Inga'와 ‘Ripple'에서 개화소요일수와 개화수를 크게 증가 시켰으며 ’Reinhold Ambrosia'에서는 오히려 개화소요일수를 단축시켰다. 차광과 저온의 조합처리의 경우 저온처리후 차광처리가 높을수록 ‘Inga'와 ’Ripple'은 개화소요일수와 개화수는 증가하였으나, ‘Reinhold Ambrosia'에서는 개화소요일수와 개화기간이 단축되었고 개화수는 증가하였다. $GA_3$ 처리에 따른 개화반응에 있어서 지베렐린 처리농도가 높아질수록 ’Ripple'과 ‘Reinhold Ambrosia'는 개화소요일수가 뚜렷이 단축되었고 개화기간은 증가하였으나 'Inga'에서는 별다른 차이가 없었다. 개화수는 ’Inga'와 ‘Ripple'에서 증가하였다. 이와같이 azalea에 차광, 저온 및 지베레린을 처리하므로서 개화기간이 연장되고, 개화수는 증가하는데 비해 개화소요일수는 품종에 따라 다르게 나타났다.

  • PDF