• Title/Summary/Keyword: Ring Finger

Search Result 138, Processing Time 0.025 seconds

Cubital tunnel syndrome associated with previous ganglion cyst excision in the elbow: a case report

  • Woojin Shin;Taebyeong Kang;Jeongwoon Han
    • Clinics in Shoulder and Elbow
    • /
    • v.27 no.1
    • /
    • pp.131-135
    • /
    • 2024
  • Cubital tunnel syndrome refers to compression neuropathy caused by pressure on the ulnar nerve pathway around the elbow. A 63-year-old male patient visited the clinic complaining of decreased sensation and weakness in his left ring finger and little finger, stating that the symptoms first began 6 months prior. He had undergone surgery to remove a ganglion cyst from his left elbow joint about 5 years prior in Mongolia. Magnetic resonance imaging revealed a cystic mass located at the previous surgical site, which was compressing the ulnar nerve within the cubital tunnel. Ulnar nerve decompression and anterior transposition were performed, and the cystic mass was excised. Upon pathological examination, the mass was diagnosed as a ganglion cyst. The patient's symptoms including sensory dysfunction and weakness improved over the 1-year follow-up period. This report describes a rare case of ganglion cyst recurrence compressing the ulnar nerve in the cubital tunnel after previous ganglion cyst excision.

Palmprint Verification Using the Histogram of Local Binary Patterns (국부 이진패턴 히스토그램을 이용한 장문인식)

  • Kim, Min-Ki
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.10
    • /
    • pp.27-34
    • /
    • 2010
  • This paper proposes an efficient method for verifying palmprint which is captured at the natural interface without any physical restriction. The location and orientation of the region of interest (ROI) in palm images are variously appeared due to the translation and rotation of hand. Therefore, it is necessary to extract the ROI stably for palmprint recognition. This paper presents a method that can extract the ROI, which is based on the reference points that are located at the center of the crotch segments between index finger and middle finger and between ring finger and little finger. It also proposes a palmprint recognition method using the histogram of local binary patterns (LBP). Experiments for evaluating the performance of the proposed method were performed on 1,597 palmprint images acquired from 100 different persons. The experimental results showed that ROI was correctly extracted at the rate of 99.5% and the equal error rate (EER) and the decidability index d' indicating the performance of palmprint verification were 0.136 and 3.539, respectively. These results demonstrate that the proposed method is robust to the variations of the translation and rotation of hand.

The Development of Portable Body Fat Meter (휴대용 체지방계의 개발)

  • Park, Jong-Chan;Lim, Eung-Choon;Park, Su-Hong;Han, Un-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.34-37
    • /
    • 2003
  • The purpose of this paper is the development of portable body fat meter. Bioelectrical impedance method for measuring human body composition is based upon the principle that the electrical conductivity of the fat mass is far greater than that of the fat. Finally measurement of percent body fat was made possible using a developed impedance measuring device which measure impedance between the thumb and ring finger.

  • PDF

p38 MAPK Participates in Muscle-Specific RING Finger 1-Mediated Atrophy in Cast-Immobilized Rat Gastrocnemius Muscle

  • Kim, Jung-Hwan;Won, Kyung-Jong;Lee, Hwan-Myung;Hwang, Byong-Yong;Bae, Young-Min;Choi, Whan-Soo;Song, Hyuk;Lim, Ki-Won;Lee, Chang-Kwon;Kim, Bo-Kyung
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.13 no.6
    • /
    • pp.491-496
    • /
    • 2009
  • Skeletal muscle atrophy is a common phenomenon during the prolonged muscle disuse caused by cast immobilization, extended aging states, bed rest, space flight, or other factors. However, the cellular mechanisms of the atrophic process are poorly understood. In this study, we investigated the involvement of mitogen-activated protein kinase (MAPK) in the expression of muscle-specific RING finger 1 (MuRF1) during atrophy of the rat gastrocnemius muscle. Histological analysis revealed that cast immobilization induced the atrophy of the gastrocnemius muscle, with diminution of muscle weight and cross-sectional area after 14 days. Cast immobilization significantly elevated the expression of MuRF1 and the phosphorylation of p38 MAPK. The starvation of L6 rat skeletal myoblasts under serum-free conditions induced the phosphorylation of p38 MAPK and the characteristics typical of cast-immobilized gastrocnemius muscle. The expression of MuRF1 was also elevated in serum-starved L6 myoblasts, but was significantly attenuated by SB203580, an inhibitor of p38 MAPK. Changes in the sizes of L6 myoblasts in response to starvation were also reversed by their transfection with MuRF1 small interfering RNA or treatment with SB203580. From these results, we suggest that the expression of MuRF1 in cast-immobilized atrophy is regulated by p38 MAPK in rat gastrocnemius muscles.

Entrapment Neuropathy of Median and Ulnar Nerve Due to Soft Tissue Chondroma: A Case Report (연부조직 연골종에 의한 정중, 척골포착신경병증: 증례보고)

  • Hong, Sung-Taek;Ahn, Duck-Sun
    • Archives of Plastic Surgery
    • /
    • v.37 no.6
    • /
    • pp.815-818
    • /
    • 2010
  • Purpose: Soft tissue chondroma is a rare benign tumor, found mainly on the palm and sole and grows slowly. Typically, mature hyaline cartilage is the dominant pathological feature. There are reports that assert soft tissue chondromas to be a cause of median nerve entrapment syndrome. However, this is the first case report showing soft tissue chondroma to be a cause of simultaneous median and ulnar neuropathy. Methods: A 62 year-old woman presented with chief complaints of numbness and hypoesthesia of her right palm for 4 to 5 years, and a palpable mass on her right palm that had been increasing in size slowly for 3 years. Physical examination revealed a firm, mobile, non-tender and about $3{\times}3\;cm^2$ sized mass in the center of the right palm. Electromyography showed entrapment neuropathy of the median and ulnar nerve. Ultrasonography showed an approximately $5.7\;cm^2$ mass below the flexor tendon of ring finger. Upon surgical excision, a $3{\times}3\;cm^2$ mass attached to the flexor digitorum profundus of ring finger and redness and hypertrophy of both the median and ulnar nerve were discovered. Mass excision was performed gently and the specimen was referred for histopathologic study. Mass excision resulted in median and ulnar nerve release. Results: The pathology report confirmed the mass to be a soft tissue chondroma with mature hyaline cartilage. The patient exhibited post-operative improvement of her symptoms and did not show any complications. Conclusion: This is the first case report showing soft tissue chondroma to be a cause of simultaneous median and ulnar neuropathy.

Effects on Goat Meat Extracts on α-Glucosidase Inhibitory Activity, Expression of Bcl-2-Associated X (BAX), p53, and p21 in Cell Line and Expression of Atrogin-1, Muscle Atrophy F-Box (MAFbx), Muscle RING-Finger Protein-1 (MuRF-1), and Myosin Heavy Chain-7 (MYH-7) in C2C12 Myoblsts

  • Joohyun Kang;Soyeon Kim;Yewon Lee;Jei Oh;Yohan Yoon
    • Food Science of Animal Resources
    • /
    • v.43 no.2
    • /
    • pp.359-373
    • /
    • 2023
  • This study examined the α-glucosidase inhibitory, and apoptosis- and anti-muscular-related factors of goat meat extracts from forelegs, hind legs, loin, and ribs. The goat meat extracts were evaluated for their α-glucosidase inhibitory activity. The gene and protein expression levels of Bcl-2-associated X (bax), p53, and p21 were examined by reverse transcription polymerase chain reaction (RT-PCR) and immunoblotting in AGS and HT-29 cells. The expression levels of Atrogin-1 and MHC1b were examined by RT-PCR in C2C12 myoblasts, and the expression levels of Atrogin-1, muscle atrophy F-box (MAFbx), muscle RING-finger protein-1 (MuRF-1), and myosin heavy chain-7 were investigated by immunoblotting. α-Glucosidase inhibitory activity was higher in ethanol extract than in hydrous and hot water extracts. BAX and p53 expression levels were higher (p<0.05) in AGS cells treated with goat meat extract than those of cells treated with no goat meat extract. In HT-29 cells, the protein expression levels of BAX, p53, and p21 were higher (p<0.05) in the cells treated with goat meat extract than those of cells not treated with goat meat extract. In dexamethasone-treated C2C12 cells, goat meat extract treatment lower (p<0.05) the expression of Atrogin-1 and lower (p<0.05) the expression of MAFbx and MuRF-1. The results of the present study indicate that goat meat extracts have α-glucosidase inhibitory activity in vitro. In addition, apoptosis was induced in AGS cells and HT-29 cells treated with goat meat extract, and anti-muscular atrophy activity was also observed in C2C12 cells treated with goat meat extract.

Ring-type Heart Rate Sensor and Monitoring system for Sensor Network Application (센서 네트워크 응용을 위한 반지형 맥박센서와 모니터링 시스템)

  • Jang, In-Hun;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.5
    • /
    • pp.619-625
    • /
    • 2007
  • As low power, low cost wireless communication technology like Bluetooth, Zigbee, RFID has been put to practical use together with the wellbeing trend, the concern about ubiquitous health care has been greatly increased and u-Health is becoming one of the most important application in the sensor network field. Especially, development of the medical services to be able to cope with a state of emergency for solitary senior citizens and the aged in silver town is very meaningful itself and their needs are also expected to continuously increase with a rapid increase in an aging population. In this paper we demonstrate the feasibility of extracting accurate heart rate variability (HRV) measurements from photoelectric plethysmography(PPG) signals gathered by a ring type pulse oximeter sensor attached to the finger. For this, we made 2 types of ring sensor, that is reflective and pervious type, and developed the remote monitoring system which is able to collect HR data from ring sensor, analyze and cope with a state of emergency.

A Tunable Digital Tourniquet Using Nelaton Catheter (고무 도뇨관을 이용한 간단한 수지 지혈대)

  • Kim, Sang Wha;Yim, Young Min;Jung, Sung No;Kwon, Ho
    • Archives of Plastic Surgery
    • /
    • v.35 no.6
    • /
    • pp.759-761
    • /
    • 2008
  • Purpose: Surgery on digit requires a clear, bloodless field and it can be achieved by using a tourniquet. Several type of tourniquet have been used including Penrose drains and sterile glove with hemostat. We present a simple digital tourniquet using nelaton catheter, which is easily available, inexpensive, easy-to-apply, and effective for digital surgery. Methods: We made a small incision on the opposite side of an opening at the tip of nelaton catheter. Then the other tip of nelaton catheter is passed through the incision to form a ring. Nelaton catheter is placed aournd the base of the injured finger, making a tight circle to desired pressure. Results: A simple tourniquet using nelaton catheter effectively achieves a bloodless field and allows fine control of the pressure for digital surgery. Conclusion: We present a sismple digital tourniquet using nelaton catheter, which is easily available, inexpensive, tunable, and available for more than one finger.