• Title/Summary/Keyword: Ring Filters

Search Result 38, Processing Time 0.02 seconds

Analysis of Periodic Stepped Impedance Ring Resonator by the Effect of Step Perturbation and Application of Dual-Mode Bandpass Filter (스텝 Perturbation의 영향에 따른 주기적 스텝 임피던스 링 공진기의 해석 및 이중 모드 대역 통과 필터의 적용)

  • Lee, Ju-Gab;Lee, Wu-Seong;Ryu, Jae-Jong;Moon, Yeon-Kwan;Kim, Ha-Chul;Choi, Hyun-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.7
    • /
    • pp.739-747
    • /
    • 2007
  • Dual-mode bandpass filter was designed by using periodic stepped impedance ring resonator with step perturbation. The periodic stepped impedance ring resonator has the effects of size reduction and $2^{nd}$ harmonic suppression by changing characteristic impedance ratio. The perturbation for dual-mode generation was also easily controlled by characteristic impedance ratio, and the variation of dual-mode resonant frequencies and attenuation pole frequencies were analyzed by the effect of step perturbation. Chip capacitors were used for input/output coupling, and the variation of center frequency by the coupling capacitance and step perturbation was also considered. From the results, two types of 2 GHz dual-mode bandpass filter were fabricated in size of $14{\times}14mm^2$, those have different attenuation poles and bandwidths. The measured results of proposed bandpass filters showed a good agreement with the calculated estimations, and those have insertion loss of 2.52, 0.52 dB and 3 dB bandwidth of 4.03, 15.02 %, respectively.

Cascaded Raman fiber amplifier operating at 1.3.mu.m using WDM couplers

  • Chang, Do-Il;Kong, Hong-Jin;Chernikov, S.V.;Guy, M.-J.;Taylor, J. R.
    • Journal of the Optical Society of Korea
    • /
    • v.1 no.2
    • /
    • pp.110-115
    • /
    • 1997
  • We report effcient cascaded Raman generation and signal amplification at 1.3.mu.m achieved in a ring resonator constructed solely from fiber components, i.e. fusion WDM couplers. Low-loss single-mode fiber with moderate $GeO_2$ content (18 mole %) is used as an active medium and pumped by a Nd:YAG laser at 1.064.mu.m. In a resonant cascaded geometry, this generates the third Stokes line at 1.24.mu.m, which acts as a pump for signal wavelength around 1.3.mu.m. A DFB laser operating at 1.315.mu.m is used to provide an input signal. An output signal powers up to 20 dBm (100 mW) with a 28 dB Raman gain are attained, where the Nd:YAG pump power is 3.4 W. It is also shown experimentally that it is important to use optical filters to suppress feedback from the resonator, permitting high Raman gain and good signal quality.

SOI CMOS Miniaturized Tunable Bandpass Filter with Two Transmission zeros for High Power Application (고 출력 응용을 위한 2개의 전송영점을 가지는 최소화된 SOI CMOS 가변 대역 통과 여파기)

  • Im, Dokyung;Im, Donggu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.1
    • /
    • pp.174-179
    • /
    • 2013
  • This paper presents a capacitor loaded tunable bandpass chip filter using multiple split ring resonators (MSRRs) with two transmission zeros. To obtain high selectivity and minimize the chip size, asymmetric feed lines are adopted to make a pair of transmission zeros located on each side of passband. Compared with conventional filters using cross-coupling or source-load coupling techniques, the proposed filter uses only two resonators to achieve high selectivity through a pair of transmission zeros. In order to optimize selectivity and sensitivity (insertion loss) of the filter, the effect of the position of asymmetric feed line on transmission zeros and insertion loss is analyzed. The SOI-CMOS switched capacitor composed of metal-insulator-metal (MIM) capacitor and stacked-FETs is loaded at outer rings of MSRRs to tune passband frequency and handle high power signal up to +30 dBm. By turning on or off the gate of the transistors, the passband frequency can be shifted from 4GH to 5GHz. The proposed on-chip filter is implemented in 0.18-${\mu}m$ SOI CMOS technology that makes it possible to integrate high-Q passive devices and stacked-FETs. The designed filter shows miniaturized size of only $4mm{\times}2mm$ (i.e., $0.177{\lambda}g{\times}0.088{\lambda}g$), where ${\lambda}g$ denotes the guided wave length of the $50{\Omega}$ microstrip line at center frequency. The measured insertion loss (S21)is about 5.1dB and 6.9dB at 5.4GHz and 4.5GHz, respectively. The designed filter shows out-of-band rejection greater than 20dB at 500MHz offset from center frequency.

Integrated Photonic Microwave Bandpass Filter Incorporating a Polymer Microring Resonator (폴리머 마이크로링 공진기를 이용한 광학적 마이크로웨이브 대역통과 필터)

  • Chin, Won-Jun;Kim, Do-Hwan;Song, Ju-Han;Lee, Sang-Shin
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.5
    • /
    • pp.469-475
    • /
    • 2005
  • An integrated photonic microwave bandpass filter has been proposed and demonstrated incorporating a coherently coupled microring resonator in low-loss polymers. The proposed device may feature compact site, simple structure, tuning via the thermooptic and electrooptic effect, and flexible integration with other electrical and optical devices. The resonator was designed to have an extremely small bandwidth so that it could be used to selectively pass the optical signal carrying the microwave signal to attain efficient bandpass filtering. We made and tested two resonators with a single ring and double rings, and performed a theoretical fitting of their measured transfer curves to predict the performance of the microwave filters based on them precisely. It was found that as the number of the rings used for the resonator increases, the bandwidth gets smaller, the rolloff sharper, and the band rejection higher. Finally our filter exhibited the center frequency of 10GHz, the 3-dB bandwidth of 1.0GHz, the corresponding quality (Q) factor of 10, and the rejection outside of the passband of more than 25dB.

Design of a lighting system for PCB visual pattern inspection (인쇄회로기판의 패턴 검사용 조명장치 설계)

  • Na, Hyun-Chan;Rho, Byung-Ok;Ryu, Yung-Kee;Cho, Hyung-Suck
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.1
    • /
    • pp.1-11
    • /
    • 1997
  • Austomated visual inspection(AVI) capability has become an important key component in the automated manufacturing system. In such a visual inspection system an intensity(or color) image of a scene is quickly affected by optical property of objects, condition and roughness of surface, lens and filters, image sensor property and lighting system. In particular, the lighting system disign is the most important factor, since it affects overall performance of the visual system. For fast and cheap automated visual inspection system it is important to obtain the good image quality which results from careful attention to the design of the lighting system. In this paper, the lighting subsystem of AVI system is analysed for the inspection of printed circuit board(PCB) patterns. The spectral reflectance of materials, which are composed of PCB, is measured for choosing the light source. The reflection property is theoretically obtained by a reflection model and also obtained by experiments which measure intensity with varying the viewing direction of image sensor and the lighting direction of illuminator. The illumination uniformity of a ring-type illuminator. The lighting system is designed based upon the experimental results and theoretial analysis.

A STUDY OF THE CYTOTOXICITY OF DENTAL CEMENTS ON HUMAN FIBROBLAST IN VITRO (생체외(生體外) 섬유아세포(纖維芽細胞) 배양법(培養法)을 이용(利用)한 합착성(合着性) 시멘트의 독성(毒性) 평가(評價)에 관(關)한 연구(硏究))

  • Maing, Hyung-Yull;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.1
    • /
    • pp.7-24
    • /
    • 1989
  • The purpose of the study was to evaluate the cytotoxic effects of polycarboxylate cements and zinc phosphate cements in vitro. Human fibroblasts were cultured in ${\alpha}$-MEM, and each cement was manually mixed and filled in glass ring cylinder (8${\times}$8mm in diameter, in height.) Cement filled cylinders were placed in the center of the dish (35mm in diameter) containing 3ml of ${\alpha}$-MEM. Millipore filters to simulate dentinal barrier were also placed between the cylinder and the dish, then stored in 5% $CO_2$ containing chamber for 1 and 2 weeks at the temperature of $36.6^{\circ}C$. The results of the experiments were analyzed by counting the cells in the period of one week and two weeks respectively, and were assessed by calculating the cell multiplication rate and the relative growth rate. The experimental groups and the control group were compared. The results of the study were summarized as follows. 1. Durelone brand of the polycarboxylate cements showed marked cytotoxicity after one week, but after two weeks the toxicity decreased remarkably. Poly-F brand exhibited moderate cytotoxicity after one week, but after two weeks the toxicity slightly decreased. HY-BOND brand was weakly cytotoxic after one week, but after two weeks the toxicity became significant. 2. The cytotoxicity of the zinc phosphate cements was negligible after one week, but after two weeks Lee Smith brand revealed considerable cytotoxicity. 3. In general, the zinc phosphate cements were less cytotoxic than the polycarboxylate cements.

  • PDF

AN EXPERIMENTAL STUDY ON THE CYTOTOXICITY OF CAVITY LINERS (이장재의 세포독성에 관한 실험적 연구)

  • Kim, Jeong-Hye;Kim, Yung-Hai
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.2
    • /
    • pp.77-92
    • /
    • 1990
  • The purpose of this study was to evaluate the cytotoxic effects of 6 cavity liners in vitro. Human fibroblasts were cultured in ${\alpha}$-MEM and each liner was manually mixed and filled in glass ring cylinder ($8{\times}8mm$ in diameter, in height). The cylinders filled with the liners were placed in the center of the dish (35mm in diameter) containing 3ml of ${\alpha}$-MEM. Millipore filters (pore size $0.22{\mu}m$) to simulate dentin barrier were also placed between the bottom of cylinder and the dish. Then the culture dishes were stored in 5% $CO_2$ containing incubator for 5 and 10 days at the temperature of $36.6^{\circ}C$. The results of the experiments were analyzed by counting the cells in the period of 5 and 10 days respectively, and were assessed by calculating the cell multiplication rate and the relative growth rate. The experiemntal groups and the control group were compared statistically. The results of the study were summarized as follows: 1. The cell number of Zinc oxide-eugenol was $(4.13{\pm}1.31){\times}10^4$ cells/ml at 5 days and $(4.32{\pm}1.61){\times}10^4$ cells/ml at 10 days. 2. The cell number of Cavitec was ($8.35{\pm}2.87{\times}10^4$ cells/ml and $(10.08{\pm}5.10){\times}10^4$ cells/ml at 5 and 10 days respectively. 3. The cell number of Dycal was $(13.56{\pm}3.89){\times}10^4$ cells/ml at 5 days and $(34.75{\pm}8.85){\times}10^4$ cells/ml at 10 days. 4. The cell number of life was $(11.46{\pm}3.32){\times}10^4$ cells/ml and $(21.92{\pm}6.18){\times}10^4$ cells/ml at 5 and 10 days. 5. The cell number of Base cement was $(13.73{\pm}3.73){\times}10^4$ cells/ml and $(36.68{\pm}5.20){\times}10^4$ cells/ml at 5 and 10 days. 6. The cell number of Dentin cement was $(13.58{\pm}3.90){\times}10$ cells/ml and $(66.95{\pm}24.09){\times}10$ cells/ml at 5 and 10 days. 7. The cell multiplication rate of zinc oxide-eugenol cements was significantly less than that of the calcium hydroxide and glass ionomer cement. (P < 0.05)

  • PDF

NIRS Analysis of Liquid and Dry Ewe Milk

  • Nunez-Sanchez, Nieves;Varo, Garrido;Serradilla-Manrique, Juan M.;Ares-Cea, Jose L.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1251-1251
    • /
    • 2001
  • The routine analysis of milk chemical components is of major importance both for the management of animals in dairy farms and for quality control in dairy industries. NIRS technology is an analytical technique which greatly simplifies this routine. One of the most critical aspects in NIRS analysis of milk is sample preparation and analysis modes which should be fast and straightforward. An important difficulty when obtaining NIR spectra of milk is the high water content (80 to 90%) of this product, since water absorbs most of the infrared radiation, and, therefore, limits the accuracy of calibrating for other constituents. To avoid this problem, the DESIR system was set up. Other ways of radiation-sample interaction adapted for liquids or semi-liquids exist, which are practically instantaneous and with limited or null necessity of sample preparation: Transmission and Folded Transmission or Transflectance. The objective of the present work is to compare the precision and accuracy of milk calibration equations in two analysis modes: Reflectance (dry milk) and Folded Transmission (liquid milk). A FOSS-NIR Systems 6500 I spectrophotometer (400-2500 nm) provided with a spinning module was used. Two NIR spectroscopic methods for milk analysis were compared: a) folded transmission: liquid milk samples in a 0.1 pathlength sample cell (ref. IH-0345) and b) reflectance: dried milk samples in glass fibre filters placed in a standard ring cell. A set of 101 milk samples was used to develop the calibration equations, for the two NIR analysis modes, to predict casein, protein, fat and dry matter contents, and 48 milk samples to predict Somatic Cell Count (SCC). The calibrations obtained for protein, fat and dry matter have an excellent quantitative prediction power, since they present $r^2$ values higher than 0.9. The $r^2$ values are slightly lower for casein and SCC (0.88 and 0.89 respectively), but they still are sufficiently high. The accuracy of casein, protein and SCC equations is not affected by the analysis modes, since their ETVC values are very similar in reflectance and folded transmission (0.19% vs 0.21%; 0.16% vs 0.19% and 55.57% vs 53.11% respectively), Lower SECV values were obtained for the prediction of fat and dry matter with the folded transmission equations (0.14% and 0.25% respectively) compared to the results with the reflectance ones (0.43% and 0.34% respectively). In terms of accuracy and speed of analytical response, NIRS analysis of liquid milk is recommended (folded transmission), since the drying procedure takes 24 hours. However, both analysis modes offer satisfactory results.

  • PDF