• Title/Summary/Keyword: Right to light

Search Result 386, Processing Time 0.028 seconds

A study on the emotional identification lighting of AtoN facility by LED (LED에 의한 항로표지 시설의 감성식별 조명에 대한 연구)

  • Oh, Jin-Seong;Choi, Jo-Cheon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2010.04a
    • /
    • pp.145-147
    • /
    • 2010
  • This study is the visually emotional identification lighting for easy to distinguish using 3colors LED on AtoN facility in shore and harbor, which have realized a controller for certainly express the mouth of a harbor by red light and green light of both sides a harbor and for synchronization at a time of right and left or serial sequential the harbor guidance light through synchronizer or timer by GPS. There is expectation effect that is prevent a confusion about distinguish of facility by ship's operator and to beautify a night scene of harbor, which is expressed to emotional identification lighting differ from great many lighting of harbor with variable color lighting the lighthouse body and vertical layer color lighting using LED. The function of AtoN is adapted that guidance light through synchronization or serial sequential lighting and display of harbor safety message by CW lighting, and this system is the power consumption greatly reduce by candle alternated high light LED.

  • PDF

Comparison of three-dimensional adaptation as per the rinsing time of temporary crown manufactured using a digital light processing printer (디지털 광 조명 방식으로 제작한 임시 크라운의 세척 시간에 따른 3차원 적합도 평가)

  • Lee, Beom-Il;You, Seung-Gyu;You, Seung-Min;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.42 no.4
    • /
    • pp.334-340
    • /
    • 2020
  • Purpose: This study aimed to compare three-dimensional adaptation with the rinsing time of the temporary crown produced using the digital light processing method. Methods: The maxillary right first molar abutment was scanned with a dental scanner. A temporary crown was designed with the scanned abutment. The designed crown was made of 10 temporary crowns using a digital light processing printer. The crowns were divided into the 5-minute and 10-minute rinsing groups; 5 temporary crown washes were performed for each group. In order to obtain the internal data, each group was scanned for a temporary crown. The three-dimensional fit was measured by superimposing the scanned internal surface data and the abutment data. The average comparison of three-dimensional adaptation was analyzed using the Mann-Whitney U test. Results: The 5-minute rinsing group showed a significantly higher adaptation of 71.42±3.08 ㎛ as compared to the 10-minute rinsing group (67.52±0.92 ㎛) (p<0.05). Conclusion: When making a temporary crown with a digital light processing method, a rinsing time of 10 minutes is appropriate.

Analysis of Evacuation Route Selection Pattern of Occupant according to Installation Type of Exit Light and Opening/Closing Direction of Door (유도등 설치유형 및 피난구 출입문 개폐방향에 따른 재실자의 피난경로 선택패턴분석)

  • Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.28-34
    • /
    • 2019
  • The purpose of this study is to examine the influence of occupant's path selection on the shape of the pictogram and the opening/closing of the door. This study was carried out through a simulation experiment using computer virtual reality. Exit light pictogram for exit door and exit light pictogram for passage were arranged for each scenario in type T corridor and type + corridor. The computer graphic was used to carry out the simulation. In addition, we analyzed the response of human behavior according to the two directions (left and right) of exit light pictogram for exit door and the effect of opening direction of doorway. In addition, the change of decision-making according to the presence or absence of exit light pictogram for passage was confirmed. The results of the direction selection response were as follows. First, in the case of the T-shaped corridor, if the exit light was not installed on the door, it was influenced by the opening direction of the door. Second, when the exit light is attached to the door, the selectivity in the direction that matches the exit light pictogram direction is high. As a result, it was confirmed that the pictogram direction of the exit light influenced the evacuation route selection of the occupants.

The Design of High efficiency multi-channel LED light Driver suitable for Streetlamp (가로등에 적합한 고효율 멀티채널 LED 조명 구동장치 설계)

  • Song, Je-Ho;Kim, Hwan-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4489-4493
    • /
    • 2014
  • LED light driving device has problems in efficiency and heating at higher than 150W. In addition, there is inconvenience in replacing the lighting device to another when W is not the same as the previous one. In this paper, a multi-channel LED light driver, driver embedded driver circuit in a multi-channel structure with a power system in the driver-interlocking structure was designed. With the auto control converter structure with a power efficiency above 93% and power factor above 0.98, the weight of the high efficiency LED lighting-actuating device in driver-interlocking structure, a driver in self-calibrating self-optimization structure. In this paper, at below 10% THD, the existing converter contrast weight was reduced by 40% or more.

Flow Visualization in Realistic Arterial Bypass Graft Model

  • Singh, Megha;Shin, Se-Hyun
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.3 no.1
    • /
    • pp.1-5
    • /
    • 2005
  • Background: Coronary atherosclerosis artery disease is the leading cause of morbidity and mortality. Coronary artery bypass grafting (CABG) which utilizes the saphenous vein graft, has helped in alleviating the suffering of these patients. Newer techniques are being developed to improve upon the techniques. Still there is significant number of failures, leading to re-grafting or re-vascularization. Some studies have helped in identifying the high and low shear stress regions. Further studies based on their realistic models are required. Material, methods and results: we developed the realistic model of fully blocked right coronary with bypass graft placed at angle of $5^0$ with curvature similar to that of artery. Pulsatile flow of birefringent solution through this model by polarized light was visualized. The images of complete flow field in the model were recorded and analyzed. Regions of high flow disturbances which are prone to further changes are identified. Existence of recirculation in the blocked coronary may initiate new blood-tissue interactions deleterious to bypass graft. Conclusion: Our study shows that by selecting the procedure to place bypass graft at minimum angle with curvature similar to that of artery and smooth sutures may improve the life span of the graft. This study also identified that coronary blocked regions contributing by recirculation flow at the proximal and distal regions of bypass which may require further studies.

  • PDF

Study of the Radioactive Source Detection and the Visualization with the Stereo Radiation Detector (스테레오 기반 감마선원 탐지 및 가시화에 관한 연구)

  • Park, Gang-teak;Lee, Nam-ho;Cha, Han-ju
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1100-1102
    • /
    • 2015
  • In the study, stereo-based of gamma-ray sources detector for the space including the gamma-ray source to scan in a raster scan method, and obtains a visible light image and the gamma-ray image. We went to retrieve and visualize the distance to source and the direction of the 3-dimension information from Stereo gamma-ray detectors. Configuration of the detector consisted of gamma-ray detecting sensor for gamma-ray Sources, pan-tilt for the scanning of the raster for detecting sources, and CCD camera for visible-light image. Implement a stereo structure of the device to measure the spatial distribution of source, the gamma-ray Detector and CCD camera for the stereo image acquisition was as each configuration 2. The gamma-ray detector and a visible light camera to revision the distribution of detection source, After performing each of the cameras of the stereo correction and shows the distribution of the gamma-ray Sources through 중첩 visible light image and the gamma-ray image. After Rectification process of Left and right image, we were derived visualization results of the stereo image.

  • PDF

Internet Governance in the light of Human Rights (인권적 관점에서 본 인터넷 거버넌스)

  • Park, Seong Hoon
    • Review of Korean Society for Internet Information
    • /
    • v.14 no.3
    • /
    • pp.52-57
    • /
    • 2013
  • Information and Communication Technologies(ICTs) have substantially enlarged both the opportunities to realize one's human rights but have also resulted in the emergence of new challenges. ICTs are so deeply embedded and cental to almost all aspects of human activity. And ICTs are assuming an increasingly central role in all aspects of human and societal development across the world. But this is especially true of the right to privacy, which faces challenges such as profiling and data mining for public(including national security) and private purposes. ICTs access is a fundamental right for all humans in the information age. So we have need for regulation based on human rights in the digital age. And governments have a responsibility to protect individuals against violations of human rights and data protection by public authorities, but also by private entities. In addition, internet governance and multi-stakeholder principle have to be stressed on all of the internet issues because internet governance is included in the principle of democracy which have bottom-up communication and equality. So it is very importance that Internet Governance Forum is the space for a meaningful discussion on public policy issues relating to the internet.

  • PDF

A Study on Developing the Designs of Handle for Personal Locker (개인사물함 손잡이 디자인개발 연구)

  • Cho, Sook-Kyung
    • Journal of the Korea Furniture Society
    • /
    • v.27 no.2
    • /
    • pp.104-110
    • /
    • 2016
  • The aim of this study is to develop and suggest the handle for lockers according to the design process which are used for keeping of student's personal stuffs such as books, writing implements and gym uniform in elementary, middle and high school and university as well. This includes the design development for ILGUMTUR which is specialized for office furniture, but does not own the intellectual property right yet. The design concept based on the domestic locker market survey is recessed handle at low- to intermediate price and it's material should be plastic what is solid and light. The lock system should be constructed by molding process and the name plate can be exchanged every time the owner of locker changes. Contrary to the right angle of it's external appearance, the handle of the locker is designed to be softly round and the simplicity is pursued for an easy production. On the basis of this design concept the sketch has been drawn and upgraded in full by 3D-rendering. Then the mock-up has been completed by 3D printer and ILGUMTUR has obtained a patent for the locking system based on the rotation of 2 circles.

A STUDY ON THE ATTRITION OF MAXILLARY CENTRAL INCISORS IN KOREAN (한국인 상악중절치의 교모에 관한 연구)

  • Park, Chong-Wha
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.16 no.1
    • /
    • pp.32-37
    • /
    • 1978
  • The purpose of this study was to apply the position, the form and the angle of the attrition in the natural maxillary central incisors shown on the labial surface to the artificial teeth in the field of prosthetic dentistry. So we should exactly alter the molds of artificial teeth in individual cases in order to make artificial teeth more natural. 226 extracted teeth of the maxillary central incisors were chosen as materials. I have exactly examined the teeth with a magnifying glass and a circular graduator under concentrated light. The observation brought me the following results: 1) The attrition was most prevailing at the range from the mesial angle to the middle part of cutting edge in the left maxillary central incisor, and distal angle of cutting edge in the right maxillary central incisor. 2) On the attrite form of both angles, the angulated form was more than 4 times as frequent as rounded form in the mesial angle, and almost equal in the distal angle. 3) On the attrite form of cutting edge, mesial attrite form including mesial angle was most frequent in the left maxillary central incisor, and distal attrite form including distal angle in the right maxillary central incisor. 4) The angle made by the labial surface and the attrite surface was about $39^{\circ}$, and more than 70% of the total examined teeth were included at the range from $31^{\circ}\;to\;50^{\circ}$. 5) None attrite form at the cutting edge was about 12% and completely attrite form at the cutting edge was about 27% of examined teeth.

  • PDF

3D Facial Scanners: How to Make the Right Choice for Orthodontists

  • Young-Soo Seo;Do-Gil Kim;Gye-Hyeong Lee;Kyungmin Clara Lee
    • Journal of Korean Dental Science
    • /
    • v.17 no.1
    • /
    • pp.1-13
    • /
    • 2024
  • With the advances of digital scanning technology in dentistry, the interests in facial scanning in orthodontics have increased. There are many different manufacturers of facial scanners marketing to the dental practice. How do you know which one will work best for you? What questions should you be asking? We suggest a clinical guideline which may help you make an informed decision when choosing facial scanners. The characteristics of 7 facial scanners were discussed in this article. Here are some considerations for choosing a facial scanner. *Accuracy: For facial scanners to be of real value, having an appropriate camera resolution is necessary to achieve more accurate facial image representation. For orthodontic application, the scanner must create an accurate representation of an entire face. *Ease of Use: Scanner-related issues that impact their ease of use include type of light; scan type; scan time; file type generated by the scanner; unit size and foot print; and acceptance of scans by third-party providers. *Cost: Most of the expenses associated with facial scanning involve the fixed cost of purchase and maintenance. Other expenses include technical support, warranty costs, transmission fees, and supply costs. This article suggests a clinical guideline to make the right choice for facial scanner in orthodontics.