• 제목/요약/키워드: Rig

검색결과 734건 처리시간 0.024초

아진공 터널에서 초고속 열차의 속도향상에 관한 실험적 연구 (Experimental Study for the Speed-up of a Super-speed Train Model in the Partial Vacuum Tunnel)

  • 김동현;김재흥
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.2064-2071
    • /
    • 2011
  • We are developing an innovative super-speed land transportation system running in a partial vacuum in tunnels with small inside diameter to reduce the aerodynamic drag forces. This paper presents the experimental results obtained on a small scale model when a super-speed train model passing through a tunnel with small inside diameter and a partial vacuum to reduce the aerodynamic drag forces. The experiments were performed on a 1/52-scale moving model rig in which a train model with a diameter of 58 mm and a length of 603 mm was accelerated in a launching tube with 12.27 m length by means of the compressed air launcher and then passed through a tunnel model with 17.149 m length. The partial vacuum was maintained in the tunnel in order to reduce the energy consumption of the propulsion system of the super-speed tube train at super-speed of 700 km/h. In this study, the blockage ratio of train to tunnel model is 0.336. Experimental results show the nonlinear effects of the vacuum on the speed-up of the train model in the tunnel model under the partial vacuum up to 0.21 atm and at the velocity up to 684 km/h. This paper is first study for experiments on the speed-up of a super-speed train model in the partial vacuum tunnels.

  • PDF

Effect of plate slope and water jetting on the penetration depth of a jack-up spud-can for surficial sands

  • Han, Dong-Seop;Kim, Seung-Jun;Kim, Moo-Hyun
    • Ocean Systems Engineering
    • /
    • 제4권4호
    • /
    • pp.263-278
    • /
    • 2014
  • The spudcan requires the suitable design considering the soil, platform, and environmental conditions. Its shape needs to be designed to secure sufficient reaction of soil so that it can prevent overturning accidents. Its shape also has to minimize the installation and extraction time. Even in the same soil condition, the reaction of soil may be different depending on the shape of spud can, mainly the slope of top and bottom plates. Therefore, in this study, the relation between the slope of plates and the reaction of soil with and without water jetting is analyzed to better understand their interactions and correlations. For the investigation, a wind turbine installation jack-up rig (WTIJ) is selected as the target platform and the Gulf of Mexico is considered as the target site. A multi layered (sand overlying two clays) soil profile is applied as the assumed soil condition and the soil-structure interaction (SSI) analysis is performed by using ANSYS to analyze the effect of the slope change of the bottom plate and water jetting on the reaction of soil. This kind of investigation and simulation is needed to develop optimal and smart spudcan with water-jetting control in the future.

EGR Cooler 내부 형상에 따른 Fouling이 냉각 성능에 미치는 영향 (The Effect of Cooling Efficiency on Fouling by EGR Cooler Internal Shape)

  • 남연우;오광철;이천환;이춘범;이원남
    • 한국자동차공학회논문집
    • /
    • 제19권1호
    • /
    • pp.101-108
    • /
    • 2011
  • Understanding the exhaust gas recirculation (EGR) cooler fouling in diesel engine is important factor in the durability characteristic of a EGR system. We develope a test rig and PM feeder using carbon black to examine the effect of fouling on EGR cooler devices those were consisted of flat and shell & tube type. The EGR cooler fouling process is a complex interaction involving heat exchanger shape, boundary condition, constitutes, chemistry and operating mode. As the soot deposited to EGR cooler, these formed a thin deposit layer that was less heat exchange than the fresh status of tube enclosing the exhaust gas, resulting in lower heat exchange effectiveness in both type coolers. But these deposits caused different results in pressure drop, it is increased in flat type, but decreased in Shell & tube type of EGR cooler. A cause was estimated from a change of the flow structure and a decrease of contact area as the EGR cooler fouling.

다양한 형상의 Jack-up Leg에 대한 해양 동역학적 수치해석 (Numerical Analysis of Hydrodynamic Characteristics for Various Types of Jack-up Legs)

  • 김지석;박민수;구원철
    • 한국해양공학회지
    • /
    • 제28권5호
    • /
    • pp.371-377
    • /
    • 2014
  • In this study, the hydrodynamic characteristics of various types of jack-up legs for a wind turbine installation vessel were analyzed. Using the modified Morison equation, the wave and current excitation forces on the jack-up legs were calculated. A modal analysis was performed to predict the dynamic responses for various types of jack-up legs. The Newmark-beta time integration scheme was used to solve the equation of motion in waves in the time domain. The maximum displacement and maximum bending stress were computed for four different types of legs, and their results were compared to select an optimum leg type. Finally, a six-leg jack-up rig with the selected optimal legs was modeled, and its natural period and hydrodynamic behaviors were evaluated.

다중 사용자 촬영 영상의 영상 스티칭 (Stitching Method of Videos Recorded by Multiple Handheld Cameras)

  • 미어 사데크 빌라흐;안희준
    • 한국산업정보학회논문지
    • /
    • 제22권3호
    • /
    • pp.27-38
    • /
    • 2017
  • 본 연구는 다수의 개인 사용자들이 휴대폰 카메라를 통하여 공연장 등에서 녹화한 다수의 영상을 스티칭하는 방법을 제시한다. 기존 고정형 리그(Rig)를 사용하는 360 카메라 솔루션과 대비하여, 시간 동기화, 반복적 변환행렬계산 및 카메라 센서 불일치 보정과 같은 새로운 문제들을 해결해야한다. 이 논문에서는 오디오를 사용한 시각동기화 방법, 색상 전달 방식에 따른 센서 불일치 제거, 전역 동작 안정화 알고리즘을 사용하여 변환 행렬의 업데이트를 함으로써 이러한 문제를 해결하였다. 또한, 카메라의 움직임이 크지 않은 경우에서, 제안 된 알고리즘은 화면 별 스티칭을 하는 경우 보다, 계산 속도와 화질 면에서도 우수한 성능을 보임을 실험을 통하여 확인하였다.

Three-Phase Reference Current Generator Employing with Kalman Filter for Shunt Active Power Filter

  • Hasim, Ahmad Shukri Abu;Ibrahim, Zulkifilie;Talib, Md. Hairul Nizam;Dardin, Syed Mohd. Fairuz Syed Mohd.
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.151-160
    • /
    • 2017
  • This paper presents a new technique of reference current generator based on Kalman filter (KF) estimator for three-phase shunt active power filter (APF). The stationary reference frame (d-q algorithm) is used to transform the load currents into DC component. The harmonics of load currents are extracted and the three-phase reference currents are generated using KF estimator. The work is simulated using Matlab/Simulink platform. To validate the simulation results, an experimental test-rig have been perform using real-time control dSPACE DS1104. In addition, hysteresis current control was used to generate the switching signal for the correction of the harmonics in the system. The non-linear load were constructed with three-phase rectifier which connected in series with inductor and parallel with resistor and capacitor. The results shows that the new technique of shunt APF embedded with KF is proven to eliminate the harmonics created by the non-linear load with some improvement on the total harmonics distortion (THD).

연료 분사 특성이 가솔린 엔진 HC 배출특성에 미치는 영향 (Effects of Port Fuel Injection Characteristics upon HC Emission in SI Engines)

  • 우영민;배충식;이용표
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.796-801
    • /
    • 2001
  • During cold operation period, fuel injection system directly contributes the unburned hydrocarbon formation in spark ignition engines. The relationship between injection parameters and HC emission behavior was investigated through a series of experiments. Spray behavior of port fuel injectors was characterized through a quantitative evaluation of mass concentration of liquid fuel by a patternator and PDA. 6-hole injector was found to produce finer spray than single hole one. Using a purpose-built test rig, the wall wetting fuel was measured, which was mostly affected by wall temperature. Varying coolant temperature($20{\sim}80^{\circ}C$), HC emissions were measured in a production engine. With respect to the different types of injectors, HC emission was also measured. In the 6-hole injector application, the engine produced less HC emission in low coolant temperature region. Though it produces much more amount of wetting fuel, it has the advantages of finer atomization quality. In high coolant temperature region, there was little effect between different types of injectors. The control schemes to reduce HC emissions during cold start could be suggested from the findings that the amount of fuel supply and HC emission could be reduced by utilizing fine spray and high intake wall temperature.

  • PDF

100kW급 보조동력장치용 압축기 성능시험 (Performance test for the compressor of 100kW APU)

  • 임병준;차봉준;양수석;이경진;백기영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.655-660
    • /
    • 2001
  • The performance test of a centrifugal compressor for APU(Auxiliary Power Unit) which is developed by the collaborative research of KARI and Samsung TechWin has been conducted. The investigated compressor consists of a curved inlet, a centrifugal impeller, a channel diffuser and a plenum chamber. The experiments were carried out in an open-loop centrifugal compressor test rig driven by a turbine. For three different diffusers, overall performance data were obtained at 80%, 90% and 97% of design speed. For the initially designed wedge-type diffuser, test results showed that the compressor was operated at a higher mass flow rate than the design requirement. By reducing the diffuser throat area, the compressor operating range was shifted to lower mass flow rate range. The test result of redesigned wedge-type diffuser showed high pressure loss. To reduce the diffuser loss, diffuser inlet radius was increased and airfoil-type of diffuser was adopted. This airfoil-type diffuser showed reasonal results in terms of design requirement.

  • PDF

평편족의 치료로 이용한 관절고정술시 스프링인대군 (spring ligament complex)에서 strain의 변화 (The strain of the spring ligament complex at different arthrodesis of the hindfoot for treatment of the flatfoot)

  • 이경태;배준우
    • 대한족부족관절학회지
    • /
    • 제1권1호
    • /
    • pp.38-42
    • /
    • 1997
  • It was well known that arthrodesis of the tarsal joint is an exellent procedure to correct the flatfoot deformity for relieving pain. Recently, concept of the selective tarsal joint fusion instead of the triple fusion was developedto preserve the joint motion. To investigate and compare the effect of the each different tarsal fusion, we measured the strain at the spring ligament, medial roof of the medial longitudianl arch. Five fresh frozen cadevar foot specimens, with distal half of the tibia were utilized. The superomedial portion of the spring ligament complex was dissected from the origin to the insertion. For each specimen, a calibrated open liquid metal strain guage was secured along the length of the superomedial portion. Under the specially devised test rig, measurement of the strain was taken at each test condition from the tare weight 18.2 lb followed by 38.2 lb., 82.2 lb and a maximum loads of 134.6 lb. : 1) unfused condition, 2) isolated subtalar fusion 3) isolated talonavicular fusion 4) combined subtalar and talonavicular fusion 5) triple fusion. Statistics showed that siginificant reduction in strain following the triple fusion, and from the subtalar fusion to triple fusion.

  • PDF

고속 터보기계용 공기 포일 저널 베어링의 신뢰성에 관한 연구 (A Study on the Reliability of an Air Foil Journal Bearing for High Speed Turbomachinery)

  • 이용복;김태호;김창호;이남수
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.199-206
    • /
    • 2002
  • This paper describes a reliability characteristics of an air foil journal bearing for high speed turbomachinery at room temperature. To verify the reliability of air foil journal bearing, lift-off characteristics, load carrying capacity, and 10,000 cycle start-stop test were performed with motor driven test rig. Lift-off test shows the relationship between the rotating speed of the shaft and the frictional torque with bearing surface. About load carrying capacity, the tested air foil journal bearing produced a load capacity of 500N at an operating speed of 15,000rpm, which is compared with results of numerical analysis and empirical coefficients. Finally, The trends in change of start torque, stop torque, and bearing temperature were shown during 10,000 cycle start-stop test of an air foil journal bearing. from the results of this work, an air foil bearing will be done well, as a supported bearing for high speed turbo-compressor.

  • PDF