A Study of Rewetting Temperature in Cooling of Hot Surfaces (高溫表面의 冷却時 再水着 溫度 에 관한 硏究)

  • 정문기;이영환;박종석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.4
    • /
    • pp.463-470
    • /
    • 1985
  • In this study a parametric analysis for the rewetting temperature was made with 572 data obtained from the single tube experiment. The rewetting temperature was also evaluated by measuring the vaporization time of a liquid drop on a hot surface at the elevated pressures. The results showed that the rewetting temperature increased with flooding rate, inlet subcooling pressure and initial wall temperature, and decreased with increasing axial elevation. Based on the results obtained, the rewetting temperature correlation was suggested. From the comparison of correlated rewetting temperatures with measured values, it showed that the correlated values fell within .+-.5% error from the measured values.

A Study on the Rewetting Phenomena of a Heated Tube by Bottom Flooding (下部注入 에 의한 加熱管 의 再水着 現象 에 관한 硏究)

  • 정문기;이영환
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.1
    • /
    • pp.48-56
    • /
    • 1984
  • In order to estimate the fuel rod temperature during the reflooding phase of the PWR LOCA, it is essential to obtain a better understanding of the rewetting mechanism. This paper presents the results of analytical and experimental investigations aimed at analyzing the rewetting phenomena in a heated tube. A two-dimensional solution of the rewetting for a tube is described and used to yield the correlation of the rewetting heat transfer coefficient as the function of flooding rate and inlet subcooling. This correlation prediction is in good agreement with the experimental data.

A Study of Reflood Heat Transfer in Electrically-Heated Fuel Rod Bundle (電氣加熱式 模擬燃料棒 다발에서의 再冠水 熱傳達 硏究)

  • 정문기;박종석;이영환
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.1
    • /
    • pp.7-14
    • /
    • 1986
  • To predict the fuel clad temperature during the reflooding phase of a LOCA, one may need a knowledge of reflood heat tranfer mechanism in a rod bundle. For this purpose reflooding experiments have been carried out with an electrically heated 3*3 rod bundle. Using the method for the determination of local heat transfer coefficient from the measured wall temperature the parametric effects of coolant flow rate, initial wall temperature, coolant subcooling and heat generation rate on the propagation of rewetting front were investigated. Prediction of the wall temperature histories for these experiments was discussed using REFLUX code with modification of the rewetting temperature correlation. Through this modification, better agreement between experiment and prediction was obtained.