ACCURACY OF TRI AUTO ZX® IN LOCATING APICAL FORAMEN WITH ROTARY FILE (전동 file을 장착한 Tri Auto ZX®의 치근단공 인지 정확도 평가)

  • Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.578-584
    • /
    • 1999
  • The purpose of this experiment was to determine: (1) the safe automatic apical reverse setting that prevents overinstrumentation of the root canal, using Tri Auto ZX$^{(R)}$ and (2) the effect of various irrigant on such instrumentation. The instrumentation was carried out with the automatic apical reverse setting of 0.5, 1.0, 1.5, and 2.0. The root canal irrigants used in usual manner were normal saline(0.9%), NaOCl(2.5%), and RC Prep$^{(R)}$. For each reverse setting and each irrigant, ten teeth were used with the total of 120 teeth. The distance between the file tip and the apical constriction was determined by stereomicroscope using the point that the file began to rotate in reverse direction. When the reverse setting mode was set to 0.5, 18 of 30 were overinstrumented. If these were discriminated by irrigant, 10 of 6 with 0.9% saline, 10 of 6 with NaOCl, and 10 of 6 with RC Prep$^{(R)}$ has the file tip located 0.57${\pm}$0.30mm, 0.73${\pm}$0.39mm, and 0.26${\pm}$0.25mm beyond the apical constriction respectively. In 1.0 setting 15 of 29 were over the apical constriction, and the distribution was 6 in saline, 5 in NaOCl, and 4 in RC Prep$^{(R)}$. The mean distance over the apical constriction was 0.28${\pm}$0.13mm with saline, 0.75${\pm}$0.61mm with NaOCl, and 0.25${\pm}$0.17mm with RC Prep$^{(R)}$. When the autoatic reverse mode was set to 1.5, and 2.0, 5, and 1 teeth were found to be overinstrumented in respective settings. But there were large variations in overinstrumented distances when an attempt was made to compare the effect of irrigants on this overinstrumentations and they were meaningless for the small sample size. When all of the autoreverse setting were combined to compare the number of overinstrumented teeth with each irrigant, there were no significant differences (14 for normal saline, 12 for NaOCl, 13 for RC Prep$^{(R)}$). When 0.5 or 1.0 automatic apical reverse setting mode was used the Tri Auto ZX$^{(R)}$ in clinical application, the possibility of overinstrumentation beyond the apical constriction exists in 55.9% of cases. Therefore 1.5 or 2.0 setting is safer for the preparation inside the canal but this type setting needs additional apical hand preparation of the root canal because the accuracy is lower than 0.5 or 1.0 setting.

  • PDF

Algorithm Development for Improving Output Characteristics of Thyristor Dual Converter with AC Input Voltage Variation (교류 입력 전압 변동에 따른 사이리스터 듀얼 컨버터의 출력 특성 개선을 위한 알고리즘 개발)

  • Kim, Sung-An;Han, Sung-Woo;Cho, Yun-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1437-1443
    • /
    • 2017
  • Electric energy is consumed or regenerated according to an operation of electric rail cars in urban railway power substations. A thyristor dual converter system is used to deal with the electric energy. Since the AC input voltage of power substations is $22.9kV{\pm}10%$, the magnitude of the AC voltage fluctuates according to load conditions, so the secondary side voltage of the DDY transformer also fluctuates. In the thyristor dual converter, the response characteristics of the DC output voltage and the DC output current are changed based on an initial firing angle in the cross mode conversion between the forward mode and the reverse mode. Therefore, this paper proposes the initial firing angle tracking algorithm considering fluctuation of the AC input voltage. The effectiveness of the proposed algorithm is verified by a simulation compared with the conventional algorithm.

Memory window characteristics of vertical nanowire MOSFET with asymmetric source/drain for 1T-DRAM application (비대칭 소스/드레인 수직형 나노와이어 MOSFET의 1T-DRAM 응용을 위한 메모리 윈도우 특성)

  • Lee, Jae Hoon;Park, Jong Tae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.4
    • /
    • pp.793-798
    • /
    • 2016
  • In this work, the memory window characteristics of vertical nanowire device with asymmetric source and drain was analyzed using bipolar junction transistor mode for 1T-DRAM application. A gate-all-around (GAA) MOSFET with higher doping concentration in the drain region than in the source region was used. The shape of GAA MOSFET was a tapered vertical structure that the source area is larger than the drain area. From hysteresis curves using bipolar junction mode, the memory windows were 1.08V in the forward mode and 0.16V in the reverse mode, respectively. We observed that the latch-up point was larger in the forward mode than in the reverse mode by 0.34V. To confirm the measurement results, the device simulation has been performed and the simulation results were consistent in the measurement ones. We knew that the device structure with higher doping concentration in the drain region was desirable for the 1T-DRAM using bipolar junction mode.

Analysis on the Interference from Satellites to HAPS ground station for Sharing between HAPS and FSS (HAPS와 FSS간의 주파수 공유를 위한 위성과 HAPS 지상국간의 간섭 분석)

  • 최문환;강영흥
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.610-614
    • /
    • 2003
  • The bands 27.5 - 28.35GHz and 31.0 - 31.3GHz were allocated to the High Altitude Platform Station in WRC-2000. However, since these bands were already allocated to the existing fired-satellite service, the analysis on the interference effects between the existing FSS/GSO system and FS/HAPS system should be needed. To do study on the interference effects between above two systems, we can consider two frequency operational renditions, one is the Reverse mode and the other Forward mode. In this paper, we considered the Forward mode as the frequency operational condition and analyzed the interference effect from a number of GSO satellites to HAPS ground station due to the I/N values, the latitude of HAPS and the satellite separation. In future, these results will be vital data to share between HAPS and GSO systems.

  • PDF

Crush FE Analysis of Front Side Assembly of Passenger Cars for Identifying the Roles of Major Parts Influencing on Collapse Mode with Reverse Engineering (승용차 프론트 사이드 조립체 부품의 역할과 붕괴모드에 관한 역설계적 유한요소 충돌해석)

  • Kim, Yong-Woo;Kim, Jeong-Ho;Jeong, Kyung-Shin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.4
    • /
    • pp.33-40
    • /
    • 2007
  • Crashworthiness design is of special interest in automotive industry and in the transportation safety field to ensure the vehicle structural integrity and more importantly the occupant safety in the event of the crash. Front side assembly is one of the most important energy absorbing components in relating to the crashworthiness design of vehicle. The structure and shape of the front side assemblies are different depending on auto-makers and size of vehicles. Thus, it is not easy to grab an insight on designer's intention when you glance at a new front side member without experiences. In this paper, we have performed the explicit nonlinear dynamic finite element analysis on the front side assembly of passenger cars to identify the mechanical roles of major parts in relation to collapse modes from the viewpoint of reverse engineering. To do this, we have performed crash FE analysis for the two different assemblies of small car and heavy passenger car and have compared dynamic behaviors of the two.

[ $Ca^{2+}$ ]-dependent Long-term Inactivation of Cardiac $Na^+/Ca^{2+}$ Exchanger

  • Lee, Jee-Eun;Kang, Tong-Mook
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.11 no.5
    • /
    • pp.183-188
    • /
    • 2007
  • Using BHK cells with stable expression of cardiac $Na^+/Ca^{2+}$ exchanger(BHK-NCX1), reverse mode(i.e. $Ca^{2+}$ influx mode) of NCX1 current was recorded by whole-cell patch clamp. Repeated stimulation of reverse NCX1 produced a cytosolic $Ca^{2+}$-dependent long-term inactivation of the exchanger activity. The degrees of inactivation correlated with NCX1 densities of the cells and were attenuated by reduced $Ca^{2+}$ influx via the reverse exchanger. The inactivation of NCX1 was attenuated by(i) inhibition of $Ca^{2+}$ influx with reduced extracellular $Ca^{2+}$, (ii) treatment with NCX1 blocker($Na^{2+}$), and (iii) increase of cytoplasmic $Ca^{2+}$ buffer(EGTA). In BHK-NCX1 cells transiently expressing TRPV1 channels, $Ca^{2+}$ influx elicited by capsaicin produced a marked inactivation of NCX1. We suggest that cytoplasmic $Ca^{2+}$ has a dual effect on NCX1 activities, and that allosteric $Ca^{2+}$ activation of NCX1 can be opposed by the $Ca^{2+}$-dependent long-term inactivation in intact cells.

Design Verification of the DY (Deflection Yoke) Using a CAI (Computer-Aided Inspection) Technique (전산역설계(Reverse Engineering) 기술을 이용한 편향코일(DY)의 설계 검증 연구)

  • 윤정호;전형환;최광일;김용환;이관행
    • Korean Journal of Computational Design and Engineering
    • /
    • v.3 no.1
    • /
    • pp.22-30
    • /
    • 1998
  • The deflection yoke (DY) controls the direction of the electron beam that falls on the screen of the television monitor. Its quality depends on the shape and density of coils wound around the DY coil separator. Winding frames are used to make these coils, and therefore, their shapes are essential in making quality coils. A reverse engineering(RE) is applied to create the 3D model of the winding frame. It considerably shortens the design verification time and shows the level of accuracy that is feasible in the production mode. The paper explains each step of the reverse engineering process in detail.

  • PDF

An Exploratory Research on MNC Parents' Motivation to Facilitate Reverse Knowledge Transfer (다국적기업 본사의 역지식이전 동기요인에 대한 탐색적 연구)

  • Hong, Sung-Jin;Yang, Oh-Suk
    • Asia-Pacific Journal of Business
    • /
    • v.10 no.3
    • /
    • pp.53-67
    • /
    • 2019
  • Reverse knowledge transfer has been an important research theme in the literature on multinational corporations (MNCs). This paper proposes major determinants of MNC headquarters' willingness to adopt and use marketing knowledge from their subsidiaries. We argue that the willingness will be jointly determined by both the headquarter's absorptive capacity and the focal subsidiary's transfer capacity and willingness to transfer. In addition, we argue that these capability and motivation effects are moderated by (1) institutional distance between home and the focal host country, (2) the need to unlearn existing routines, and (3) types of entry modes. This paper contributes to the reverse knowledge transfer literature by proposing the argument that both motivational and capability factors are likely to determine the MNC parents' willingness to adopt and use marketing knowledge from their subsidiaries.

Development of New Reverse Micellar Microencapsulation Technique to Load Water-Soluble Drug into PLGA Microspheres

  • Kim Hyun Joo;Cho Mi Hyun;Sah Hong Kee
    • Archives of Pharmacal Research
    • /
    • v.28 no.3
    • /
    • pp.370-375
    • /
    • 2005
  • The objective of this study was to develop a new reverse micelle-based microencapsulation technique to load tetracycline hydrochloride into PLGA microspheres. To do so, a reverse micellar system was formulated to dissolve tetracycline hydrochloride and water in ethyl formate with the aid of cetyltrimethylammonium bromide. The resultant micellar solution was used to dissolve 0.3 to 0.75 g of PLGA, and microspheres were prepared following a modified solvent quenching technique. As a control experiment, the drug was encapsulated into PLGA microspheres via a conventional methylene chloride-based emulsion procedure. The micro­spheres were then characterized with regard to drug loading efficiency, their size distribution and morphology. The reverse micellar procedure led to the formation of free-flowing, spherical microspheres with the size mode of 88 ~m. When PLGA microspheres were prepared follow­ing the conventional methylene chloride-based procedure, most of tetracycline hydrochloride leached to the aqueous external phase: A maximal loading efficiency observed our experimental conditions was below $5\%$. Their surfaces had numerous pores, while their internal architecture was honey-combed. In sharp contrast, the new reverse micellar encapsulation technique permitted the attainment of a maximal loading efficiency of 63.19 $\pm$$0.64\%$. Also, the microspheres had smooth and pore-free surfaces, and hollow cavities were absent from their internal matrices. The results of this study demonstrated that PLGA microspheres could be successfully prepared following the new reverse micellar encapsulation technique.

Physical layer design of W-CDMA IMT-2000 system and performance analysis of key characteristics

  • 채명식;홍은기;최안나;구준모
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.5
    • /
    • pp.1282-1290
    • /
    • 1998
  • In this paper, the physical layer design of IMT-2000 system being developed by SK Telecom is introuduced. The outband signaling scheme and the two-pilot scheme are adopted for multimedia service and inter-cell asynchronous mode respectively. In addition, the synchronous transmission scheme is proposed to reduce the interference in the reverse link. The algorithm and simulation results of 'two-pilot scheme' for inter-cell asynchronous mode and 'reverse synchronous control' for synchronous transmission are presented.

  • PDF