Comparison of Dynamic Operation Performance of LNG Reliquefaction Processes based on Reverse Brayton Cycle and Claude Cycle (Reverse Brayton 사이클과 Claude 사이클 기반 LNG 재액화 공정의 동특성 운전성능 비교)

  • Shin, Young-Gy;Seo, Jung-A;Lee, Yoon-Pyo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.775-780
    • /
    • 2008
  • A dynamic model to simulate LNG reliquefaction process has been developed. The model was applied to two candidate cycles for LNG reliquefaction process, which are Reverse Brayton and Claude cycles. The simulation was intended to simulate the pilot plant under construction for operation of the two cycles and evaluate their feasibility. According to the simulation results, both satisfy control requirements for safe operation of brazed aluminum plate-fin type heat exchangers. In view of energy consumption, the Reverse Brayton cycle is more efficient than the Claude cycle. The latter has an expansion valve in addition to the common facilities sharing with the Reverse Brayton cycle. The expansion valve is a main cause to the efficiency loss. It generates a significant amount of entropy associated with its throttling and increases circulation flow rates of the refrigerant and power consumption caused by its leaking resulting in lowered pressure ratio. It is concluded that the Reverse Brayton cycle is more efficient and simpler in control and construction than the Claude cycle.

Comparison of Operation Performance of LNG Reliquefaction Process according to Reverse Brayton Cycle and Claude Cycle

  • Shin, Young-Gy;Seo, Jung-A;Lee, Yoon-Pyo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.4
    • /
    • pp.135-140
    • /
    • 2009
  • A dynamic model to simulate LNG reliquefaction process has been developed. The model was applied to two candidate cycles for LNG reliquefaction process, which are Reverse Brayton and Claude cycles. The simulation was intended to simulate the pilot plant under construction for operation of the two cycles and evaluate their feasibility. According to the simulation results, both satisfy control requirements for safe operation of brazed aluminum plate-fin type heat exchangers. In view of energy consumption, the Reverse Brayton cycle is more efficient than the Claude cycle. The latter has an expansion valve in addition to the common facilities sharing with the Reverse Brayton cycle. The expansion valve is a main cause to the efficiency loss. It generates a significant amount of entropy associated with its throttling and increases circulation flow rates of the refrigerant and power consumption caused by its leaking resulting in lowered pressure ratio. It is concluded that the Reverse Brayton cycle is more efficient and simpler in control and construction than the Claude cycle.

Selective Dual Duty Cycle Controlled High Frequency Inverter Using a Resonant Capacitor in Parallel with an Auxiliary Reverse Blocking Switch

  • Saha, Bishwajit;Suh, Ki-Young;Kwon, Soon-Kurl;Mishima, Tomokazu;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.118-123
    • /
    • 2007
  • This paper presents a new ZCS-PWM high frequency inverter. Zero current switching operation is achieved in the whole load range by using a simple auxiliary reverse blocking switch in parallel with series resonant capacitor. Dual duty cycle control scheme is used to provide a wide range of high frequency AC output power regulation that is important in many high frequency inverter applications. It found that a complete soft switching operation can be achieved even for low power setting ranges by introducing high-frequency dual duty cycle control scheme. The proposed high frequency inverter is more suitable for consumer induction heating(IH) applications. The operation and control principle of the proposed high frequency inverter are described and verified through simulated results.

Modelling of a High Efficiency Refrigeration System with Heat Storage for Reverse Cycle Hot Gas Defrost

  • Ardiyansyah, Ardiyansyah;Choi, Kwang-Il;Oh, Jong-Taek;Oh, Hoo-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.4
    • /
    • pp.175-181
    • /
    • 2007
  • A computer model of a high efficiency refrigeration system equipped with heat storage for reverse cycle-hot gas defrost (the stored heat is used during defrost cycle of the system) is presented. The model was developed based on both theoretical and empirical equations for the compressor, evaporator, condenser and the heat storage equipment. Simulations of the prototype system were carried out to investigate refrigeration system performance under various operating conditions during refrigeration cycles. The simulations of the evaporator during defrost cycles at 30 and $40^{\circ}C$ hot gas refrigerant temperature were also performed which resulted on shorter defrost time but only slight increase in defrost efficiency. These information on energy efficiency and the defrost time required are important in order to avoid excessive parasitic load and temperature rise of the refrigerated room.

Design of Reverse Brayton Cycle Cryocooler System for HTS Cable Cooling (HTS 케이블 냉각용 역브레이튼 사이클 극저온 냉동기 설계에 관한 연구)

  • 박재홍;권용하;김영수;박성출
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.2
    • /
    • pp.58-65
    • /
    • 2003
  • The high temperature superconductivity(HTS) cable must be cooled below the nitrogen liquefaction temperature to applicate the cable in power generation and transmi-ssion system under the superconducting state. To obtain superconducting state. a reliable cryocooler system is required. Structural and thermal design have been performed to design cryocooler system operated with reverse Brayton cycle using gas neon as refrigerant. This cryocooler system consists of compressor. recuperator. coldbox. control valves and has 1 kW cooling capacity. Heat loss calculation was conducted for the given cryocooler system by considering the conduction and radiation through the multi-layer insulation(MLI) and high vacuum. The results can be summarized as: conduction heat loss is 7 W in valves and access port and radiation heat loss is 18 W through the surface of cryocooler. The full design specifications were discussed and the results were applied to construct in house HTS cable cooling system.

A green transportation model in reverse logistics network and its comparative assessment for environmental impacts (역물류 네트워크에서의 친환경 운송 모델 개발 및 환경영향평가 비교 분석)

  • Kim, Ki Hong;Shin, Seoung-Jun;Chung, Byung Hyun
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.3
    • /
    • pp.239-246
    • /
    • 2015
  • Enforced environmental regulations call for extending the domain of manufacturers' responsibility to the entire product life cycle. To comply with the environmental regulations, manufacturers have constructed reverse logistics networks to re-collect their leftover waste for recycling consumed resources. However, the operational activities associated with storage, loading and transportation processes within the networks inevitably impose environmental burdens. Particularly, the transportation process largely influences environmental performance due to perpetual uses of transportation vehicles. Therefore, there is a need to develop an environmentally-conscious transportation model that can efficiently manage the uses of transportation vehicles. Additionally, it is vital to analyze its significances of environmental performance to compare quantitatively it with existing models. This paper proposes a transportation model for improving environmental performance in a reverse logistics network. This paper also presents a case study to perform its comparative analysis using Life Cycle Assessment that evaluates potential environmental impacts of a product system.

DUAL DUTY CYCLE CONTROLLED SOFT-SWITCHING HIGH FREQUENCY INVERTER USING AUXILIARY REVERSE BLOCKING SWITCHED RESONANT CAPACITOR

  • Bishwajit, Saha;Suh, Ki-Young;Lee, Hyun-Woo;Mutsuo, Nakaoka
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.129-131
    • /
    • 2006
  • This paper presents a new ZVS-PWM high frequency inverter. The ZVS operation is achieved in the whole load range by using a simple auxiliary reverse blocking switch in parallel with series resonant capacitor. The operating principle and the operating characteristics of the new high frequency circuit treated here are illustrated and evaluated on the basis of simulation results. It was examined that the complete soft switching operation can be achieved even for low power setting ranges by introducing the high frequency dual duty cycle control scheme. In the proposed high frequency inverter treated here, the dual mode pulse modulation control strategy of the asymmetrical PWM in the higher power setting ranges and the lower power setting ones, the output power of this high frequency inverter could introduce in order to extend soft switching operation ranges. Dual duty cycle is used to provide a wide range of output power regulation that is important in many high frequency inverter applications. It is more suitable for induction heating applications the operation and control principle of the proposed high frequency inverter are described and verified through simulated results.

  • PDF

Pulse reverse current 을 이용한 Cu mesh 도금의 표면형상 개선

  • Lee, Jin-Hyeong;Lee, Ju-Yeol;Kim, Man
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2009.05a
    • /
    • pp.136-137
    • /
    • 2009
  • 전자파 차폐재로 메쉬를 제작하는 기존의 배치 방식은 복잡한 작업공정과 비싼 설비로 인해 생산원가 높다. 그래서 pulse reverse current를 이용하여 Cu mesh 도금을 하였다. 정펄스의 전류밀도가 $31mA/cm^2$일일 때 역펄스의 전류밀도 및 duty cycle에 상관없이 표면은 매끄럽게 나왔다. 정펄스의 전류밀도가 $454mA/cm^2$일때는 duty cycle이 25%이하는 표면상태가 매끄럽게 나타났지만 33%이상에서 표면상태가 거칠게 도금이 되었다.

  • PDF

Study of LNG Reliquefaction Process in LNG Carriers (LNG 선박에서 천연가스 재액화공정의 재액화량에 관한 연구)

  • Ko, Byoung-Seok;Kim, Bum-Su;Lee, Heon-Seok;Kang, Yun-Jin;Kim, Min-Seop;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.1
    • /
    • pp.21-27
    • /
    • 2010
  • In the past vaporized gases from a carrier were burned or used for fuel. Due to the movement of bigger LNG carriers and using diesel engine, it is limited that ways of deposing vaporizes gases from the carrier by the act of environment. For getting over the problem, a reliquefaction process is considered. Even though the reliquefaction process was created to three generation process, it has been researched and developed to optimize the process. Basically the reliquefaction process is compartmentalized into Reverse Brayton Cycle System and Claude Cycle System. This research is focused on the reliquefaction efficiency with the systems and changing equipments arrangement by using HYSYS. The result could be use for a design of a reliquefaction process.

Schmidt cycle analysis in the quest of designing stirling cryocooler

  • Chowdhury, Debajyoti Roy;Chakraborty, Nathuram;Sarkar, Swapan Chandra
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.4
    • /
    • pp.12-17
    • /
    • 2017
  • Design of Reverse Stirling Cycle based refrigerator can be predicted by Schmidt theory as a useful tool and by experiment it is found that for practical purposes the power and efficiency predicted by this analysis are about 35% of the actual values. Therefore, appropriate provision is to be made for getting the realistic result with the minimum deviation. The present paper first investigates the suitability of application of Schmidt design analysis for standard ZIF-1002 and PLN-106 Single cylinder Cryogenerator model. As the result is found to be optimistic, the same design procedure is applied for the design of a separate Cryogenerator for generating a cooling effect which is sufficient to produce 7 kg per hour liquid nitrogen using an indigenous condenser of 80% effectiveness. The paper describes all the details of the design methodologies and relevant results are found to be satisfactory.