• Title/Summary/Keyword: Reverse Power Flow

Search Result 125, Processing Time 0.024 seconds

Experimental and numerical investigations on effect of reverse flow on transient from forced circulation to natural circulation

  • Li, Mingrui;Chen, Wenzhen;Hao, Jianli;Li, Weitong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.9
    • /
    • pp.1955-1962
    • /
    • 2020
  • In a sudden shutdown of primary pump or coolant loss accident in a marine nuclear power plant, the primary flow decreases rapidly in a transition process from forced circulation (FC) to natural circulation (NC), and the lower flow enters the steam generator (SG) causing reverse flow in the U-tube. This can significantly compromise the safety of nuclear power plants. Based on the marine natural circulation steam generator (NCSG), an experimental loop is constructed to study the characteristics of reverse flow under middle-temperature and middle-pressure conditions. The transition from FC to NC is simulated experimentally, and the characteristics of SG reverse flow are studied. On this basis, the experimental loop is numerically modeled using RELAP5/MOD3.3 code for system analysis, and the accuracy of the model is verified according to the experimental data. The influence of the flow variation rate on the reverse flow phenomenon and flow distribution is investigated. The experimental and numerical results show that in comparison with the case of adjusting the mass flow discontinuously, the number of reverse flow tubes increases significantly during the transition from FC to NC, and the reverse flow has a more severe impact on the operating characteristics of the SG. With the increase of flow variation rate, the reverse flow is less likely to occur. The mass flow in the reverse flow U-tubes increases at first and then decreases. When the system is approximately stable, the reverse flow is slightly lower than obverse flow in the same U-tube, while the flow in the obverse flow U-tube increases.

Development of Protection Method for Power System interconnected with Distributed Generation using Distance Relay

  • Kim, Ji-Soo;Cho, Gyu-Jung;Song, Jin-Sol;Shin, Jae-Yun;Kim, Dong-Hyun;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2196-2202
    • /
    • 2018
  • The conventional power system allowed only downstream power flow. Therefore, even if a fault occurs, only the forward current flow is considered. However, with the interest in distributed generation (DG), DGs such as Photovoltaic (PV), Wind Turbine (WT) are being connected to a power system. DGs have many advantages, but they also have disadvantage such as generation of reverse flow. Reverse flow can severely disrupt existing protection systems that only consider downstream power flow. The major problems that may arise from reverse power flow are blinding protection and sympathetic tripping. In order to solve such problems, the methods of installing a directional relay or a fault current limiter is proposed. However, this method is inconceivable because of the economics shortage. Therefore, in this paper, a distance relay installed in existing power system is used to solve the protection problem. Modeling of distance relay has been carried out using ElectroMagnetic Transients Program (EMTP), and it has been verified through simulations that the above problems can be solved by a distance relay.

A Study on the Reverse-Power-Flow Phenomenon due to Transformer Wiring Types in Distribution System (배전계통에서 변압기 결선에 의한 역 조류현상에 관한 연구)

  • Shin, Dong-Yeol;Ha, Bok-Nam;Jung, Won-Wook;Cha, Han-Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.111-119
    • /
    • 2008
  • As the penetration of distributed generation systems is recently high, there have been metering errors, trips of protective devices in KEPCO distribution systems including an occurrence of false fault-indicator in distribution automation system. The cause of malfunctions was the reverse-power-flow phenomenon due to transformer wiring types. By the effect of the reverse-power-flow, each of phase's fundamental currents was added by about 3 times on the neutral line. A new method based on the analysis of the reverse-power-flow is proposed in this paper. Fault currents on each section were analyzed by the proposed method, and the effect of types of transformer wiring was examined experimentally. In order to reduce the malfunctions due to the reverse-power-flow, controlling the zero-sequence impedance of transformer was designed and verified by using PSCAD/EMTDC software.

Effect of Seawater/Fresh Water Flow Rates on Power Density of Reverse Electrodialysis (RED 전력밀도에 미치는 해수/담수 유량의 영향)

  • Na, Jong-Chan;Kim, Han-Ki;Kim, Chan-Soo;Han, Moon-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.9
    • /
    • pp.624-628
    • /
    • 2014
  • Reverse electrodialysis (RED) is a technique to produce electricity from two feed water that has different salinity. Recently, RED has been considered the attractive technology because this new process has large global potential and possibility to generate energy from abundant but largely unused resources. To make RED an economically attractive technology, the optimization of operation condition should be developed. In this study, we investigate the relation of internal resistance to power density of RED. And the effect of sea water and fresh water flow rate on power density was confirmed. To minimize the internal resistance and to increase power density of RED, the ratio of sea water and fresh water flow rate was optimized. Experimental result show the best performance with $1.30W/m^2$ of power density at 1.7 flow ratio of seawater/freshwater.

Proposed Distribution Voltage Control Method for Connected Cluster PV Systems

  • Lee, Kyung-Soo;Yamaguchi, Kenichiro;Kurokawa, Kosuke
    • Journal of Power Electronics
    • /
    • v.7 no.4
    • /
    • pp.286-293
    • /
    • 2007
  • This paper proposes a distribution voltage control method when a voltage increase condition occurs due to reverse power flow from the clustered photovoltaic (PV) system. This proposed distribution voltage control is performed a by distribution-unified power flow controller (D-UPFC). D-UPFC consists of a hi-directional ac-ac converter and transformer. It does not use any energy storage component or rectifier circuit, but it directly converts ac to ac. The distribution model and D-UPFC voltage control using the ATP-EMTP program were simulated and the results show the voltage increase control in the distribution system.

Highly Efficient High-Voltage MOSFET Converter with Bidirectional Power Flow Legs

  • Ryu, Hyung-Min
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.265-270
    • /
    • 2014
  • In terms of power loss, a MOSFET has two advantages over an IGBT with an antiparallel diode: purely resistive without an offset voltage in conduction and no tail current at turn-off. However, the reverse recovery characteristic of the body diode is so poor that MOSFETs have not yet been available for high-voltage power converters with bidirectional power flow legs. This paper introduces how MOSFETs can be fully applied to high-voltage power converters with bidirectional power flow legs in order to achieve high efficiency. With a bidirectional DC-DC converter with one leg as the simplest example, the basic circuit topology and operating principle are described in detail. The high efficiency and stable operation of the proposed converter are validated through experiments with a 1.5 kW prototype.

A Study on Velocity Distribution Around Ship Stern by Improved Power Law Flow Model (멱법칙 유동모델의 개선에 의한 선미 유동장내 속도분포 연구)

  • 김시영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.7
    • /
    • pp.1391-1397
    • /
    • 1992
  • Improved power law flow model was suggested for the calculation of wake flow characteristics around the three dimensional ship stern in case of the formation of bilge vortex in the direction of stern. In comparison with the power law and Coles flow model, the flow velocity calculated based on this study was delayed around the boundary of inner layer and outer layer in reverse flow. More accurate results was obtained with this improved power law flow model by the velocity calculation around ship stern. Accuracy was validated with the comparison of other calculation results and experimental datas.

Computational Flow Analysis of a Cross-Flow Fan by LES (LES에 의한 관류홴의 전산유동해석)

  • Kim, J.K.;Oh, S.H.
    • Journal of Power System Engineering
    • /
    • v.14 no.6
    • /
    • pp.20-28
    • /
    • 2010
  • The computational flow analysis using LES technique was carried out to investigate the flow characteristics of a RAC chassis consisting of a rear-guider, a stabilizer and a cross-flow fan. The commercial SC/Tetra software was used in this analysis. In view of the results so far achieved, the distribution trends of static pressure and velocity vector of central region except the edges of a CFFan are similar regardless of the number of revolution, and an eccentric vortex exists around the bottom blade of a CFFan. Also, a reverse flow is found in the region between stabilizer and CFFan. Moreover, near the edges of a CFFan, an eccentric vortex is separated to two vortexes. Also these vortexes increase the velocity near a rear-guider, and guide the flow near a rear-guider into stabilizer inlet. Therefore, the reverse flow region is formed in the bottom of a CFFan.

Numerical Study on Flow and Heat Transfer Enhancement during Flow Boiling in Parallel Microchannels (병렬 미세관 흐름비등의 유동특성 및 열전달 향상에 대한 수치적 연구)

  • Jeon, Jin-Ho;Lee, Woo-Rim;Suh, Young-Ho;Son, Gi-Hun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.472-473
    • /
    • 2008
  • Flow boiling in parallel microchannels has received attention as an effective heat sink mechanism for power-densities encountered in microelectronic equipment. the bubble dynamics coupled with boiling heat transfer in microchannels is still not well understood due to the technological difficulties in obtaining detailed measurements of microscale two-phase flows. In this study, complete numerical simulation is performed to further clarify the dynamics of flow boiling in microchannels. The level set method for tracking the liquid-vapor interface is modified to include the effects of phase change and contact angle. The method is further extended to treat the no-slip and contact angle conditions on the immersed solid. Also, the reverse flow observed during flow boiling in parallel microchannels has been investigated. Based on the numerical results, the effects of channel shape and inlet area restriction on the bubble growth, reverse flow and heat transfer are quantified.

  • PDF

Comparative analysis of internal flow characteristics of LBE-cooled fast reactor main coolant pump with different structures under reverse rotation accident conditions

  • Lu, Yonggang;Wang, Xiuli;Fu, Qiang;Zhao, Yuanyuan;Zhu, Rongsheng
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2207-2220
    • /
    • 2021
  • Lead alloy is used as coolant in Lead-based cooled Fast Reactor (LFR). The natural characteristics of lead alloy are combined with the simple structural design of LFR. This constitutes the inherent safety characteristics of LFR. The main work of this paper is to take the main coolant pump (MCP) in the lead-cooled fast reactor (LFR) as the research object, and to study the flow pattern distribution of the internal flow field under the reverse rotation pump condition, the reverse rotation positive-flow braking condition and the reverse rotation negative-flow braking condition. In this paper, the double-outlet volute type and the space guide vane are selected as the potential designs of the CLEAR-I MCP. In this paper, the CFD method is used to study the potential reverse accident of the MCP. It is found that the highest flow velocity in the impeller appears at the impeller outlet, and the Q-H curves of the two design programs basically coincide. The space guide vane type MCP has better hydraulic performance under the reverse rotation positive-flow condition, the Q-H curves of the two designs gradually separate with increasing flow rate, and the maximum flow velocity inside the space guide vane type MCP is obviously lower than that of the double-outlet volute type. For the reverse rotation test of MCP, only the condition of the forward rotating pump of the main coolant pump is tested and verified. For the simulation of the MCP in LBE medium, it proved that the turbulence model and basic settings selected in the simulation are reliable.