• 제목/요약/키워드: Reverse Plate

검색결과 179건 처리시간 0.025초

Effects of reverse waves on the hydrodynamic pressure acting on a dual porous horizontal plate

  • Kweon, Hyuck-Min;Choi, Young-Hwan
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제6권1호
    • /
    • pp.60-73
    • /
    • 2014
  • The seaward reverse wave, occurring on the submerged dual porous horizontal plate, can contribute to the reduction of the transmitted wave as it reflects the propagating wave. However, the collision between the propagating and seaward reverse waves increases the water level and acts as a weight on the horizontal plate. This study investigated the characteristics of the wave pressure created by the seaward reverse wave through the analysis of experimental data. The analysis confirmed the following results: 1) the time series of the wave pressure showed reverse phase phenomena due to the collision, and the wave pressures acted simultaneously on both upper and lower surfaces of the horizontal plate; 2) the horizontal plate became repeatedly compressed and tensile before and after the occurrence of the seaward reverse wave; and 3) the seaward reverse wave created the total wave pressure to the maximum towards the direction of gravity, primarily on the upper plate. It was also confirmed that the wave distributions showed a similar trend to the wave steepness. Such outcome of the analysis will provide basic information to the structural analysis of the horizontal plate as a wave dissipater of the steel-type breakwater (STB).

중금속[Cu(II), Zn(II)]의 분리 및 농축을 위한 역삼투 판틀형 모듈의 적용 (Application of Reverse Osmosis Plate and Frame Type for Separation and Concentration Heavy Metal[Cu(II), Zn(II)])

  • 이광현;강병철;이종백;김종팔
    • 한국물환경학회지
    • /
    • 제20권4호
    • /
    • pp.307-312
    • /
    • 2004
  • This study was focused on experiment for the separation and concentration process of Cu(II), Zn(II) solution with the variation of applied pressure and concentration using reverse osmosis plate and frame modules. Rejection coefficient and degree of concentration for Cu(II) component using single and multi-stage reverse osmosis process were showed 96.3~97.8%, 0.044~0.191(in single-stage), 96.3~98.4%, 0.400~2.264(in multi-stage) within the range of experimental condition, respectively. Those of Zn(II) were 93.3~97.1%, 0.019~0.395(in single-stage), 96.3~98.2%, 0.365~1.454(in multi-stage), respectively. Degree of concentration of multi-stage were higher than those of single-stage. Heavy metal[Cu(II), Zn(II)] separation was very efficient in using reverse osmosis plate and frame type modules. Separation efficiency for a mixed solution Cu(II) and Zn(II) was higher than those of each one of Cu(II) and Zn(II).

평판형 막모듈을 이용한 합성염료 폐수처리에 있어서 염농도 및 온도의 영향 (Effect of Salt Concentration and Temperature in Synthetic Dyestuff Wastewater Treatment using Plate and Frame Membrane Module)

  • 김선일;이봉우;윤영재
    • 한국환경과학회지
    • /
    • 제7권2호
    • /
    • pp.209-216
    • /
    • 1998
  • Nanofiltration[NF45] and reverse osmosis membrane(HR98PP) separation treatment of dyestuff wastewater was carried out In order to separate relatively pure water from synthetic dyestuff wastewater, which consists of reactive dye, acid dye, basic dye, direct dye, and disperse dye. The experiments were performed by using the plate and frame membrane module. In the nanofiltration and reverse osmosis membrane separation, When the NaCl concentration was 0.1, 5.0, and 20.091, retention was 63.0, 46.0, 0.9%, respectively. When permeate flux was 125.0, 67.5, and 45.0 L/$m^2$ h, the osmotic pressure increased with Increasing the NaCl concentration. Permeate flux of two membranes Increased as temperature Increased due to segmental movement of polymer of the membrane and the rejection rate of dyestuff was decreased gradually. It was found that the rejection rate was about 95% in the nanofiltratlon, while the reverse osmosis membrane showed a high rejection rate of 99% under all temperature and pressures conditions.

  • PDF

The Pumping Characteristics of the Valveless Peristaltic Micropump by the Variation of Design Parameters

  • Chang, In-Bae;Park, Dae-Seob;Kim, Byeng-Hee;Kim, Heon-Young
    • KSTLE International Journal
    • /
    • 제3권2호
    • /
    • pp.101-109
    • /
    • 2002
  • This paper presents the fabrication and performance inspection of a peristaltic micropump by flow simulation. The valve-less micropump using the diffuser/nozzle is consists of base plate, mid plate, top plate and connection tubes fur inlet and outlet. In detail, the base plate is composed of two diffuser nozzles and three chambers, the mid plate consists of a glass diaphragm for the volumetric change of the pumping chamber. The inlet and outlet tubes are connected at the top plate and the actuator fur pressing the diaphragm is located beneath the top plate. The micropump is fabricated on the silicon wafer by DRIE (Deep Reactive ion Etching) process. The pumping performances are tested by the pneumatic test rig and compared with the simulated results fur various dimensions of diffuser nozzles. The pumping characteristics of the micropump by the volumetric change at the pumping chamber is modeled and simulated by the commercial software of FLOW-3D. The simulated results shows that reverse flow is the inherent phenomena in the diffuser nozzle type micropump, but it can be reduced at the dual pumping chamber model.

1열 원형 충돌수분류군에 의한 열전달의 실험적 연구 (제2보, 노즐-전열면간 거리의 영향) (Impingement heat transfer within 1 row of circular water jets: Part 2-Effects of nozzle to heated surface distance)

  • 엄기찬;이종수;김상필
    • 설비공학논문집
    • /
    • 제12권1호
    • /
    • pp.59-66
    • /
    • 2000
  • In a previous paper, we have examined the effects of nozzle configuration and jet to jet spacing on the heat transfer of 1 row of circular water jets. In this paper, experiments have been conducted to obtain the effects of nozzle to target plate distances on the heat transfer of 1 row of 3 jets and 1 row of 5 jets. The nozzle configurations are Cone type, Reverse cone type and Vertical circular type. Nozzle to target plate distance H was varied from 16 mm(H/D=2) to 80mm(H/D=10). For fixed value of mass flow rate and nozzle to target plate distance, larger values of average Nusselt number were obtained for the smaller jet to jet spacing. For the array of water jets, the average heat transfer was decreased slightly with increasing nozzle to target plate distance at low jet velocity of $\textrm{V}_{o}$=3 m/s. However, except for $\textrm{V}_{o}$=8 m/s of 1 row of 5 jets, it was increased with increasing nozzle to target plate distance at high jet velocity of $\textrm{V}_{o}$$\geq$6m/s. We proposed to apply the nozzle configuration of maximum average heat transfer to each nozzle to target plate distance for 1 row of 3 jets, and, it was Reverse cone type nozzle for 1 row of 5 jets(Reynolds number$\geq$36000).

  • PDF

산화막 형성 방법에 따른 전계판 구조 탄화규소 쇼트키 다이오드의 역전압 특성 (Reverse Characteristics of Field Plate Edge Terminated SiC Schottky Diode with $SiO_2$ formed Various Methods)

  • 방욱;정희종;김남균;김상철;서길수;김형우;청콴유;김은동
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.409-412
    • /
    • 2004
  • Edge termination technique is essential fer the fabrication of high volage devices. A proper edge termination technique is also needed in the fabrication of Silicon Carbide power devices for obtaining a stable high blocking voltage properties. Among the many techniques, the field plate formation is the easiest one that can utilize it for commercial usage. The growth of thick thermal oxide is difficult for SiC, however. In this paper, 6A grade SiC schottky barrier diodes(SBD) were fabricated with field plate edge termination. The oxides which is field plate were formed various methods such as dry oxidation, 10% $N_2O$ nitrided oxidation and PECVD deposition. The reverse characteristics of the SiC SBD with various oxide field plate were investigated.

  • PDF

활성탄으로 코팅된 전극에서 분진의 제거 (Removal of Dust in Positive and Negative Plates of Electrode Coated with Activated Carbon)

  • 김광수;박현철;전태환;이주행;남상철
    • 한국대기환경학회지
    • /
    • 제29권6호
    • /
    • pp.830-837
    • /
    • 2013
  • The purposes of this research are to know the dust removal efficiency according to the changes of gab between positive and negative plates in dust removal chamber. The experiments for dust removal efficiencies were conducted with changing the electrode-plate gab from 2 cm to 1 cm while the electric pressure, influent flow, and linear velocity were kept 5 kV, 80 L/min, and 6 cm/sec, respectively. From the experimental results of the electrode-plate gab of 2 cm, dust removal efficiencies were decreased to as low as about 50%. Attached dust on the surface of electrodes was released due to a reverse electric charge of dust. From the experimental results of the electrode-plate gab of 1 cm, dust removal efficiencies were increased to as high as about 80% due to the dust attachment velocity to the electrodes to be far more fast than influent linear velocity. Finally, to protect a attached dust from occurring a reverse electric charge it is needed to install the non-conductor between positive and negative electrodes and also to remove air humidity.

PIV에 의한 분리된 분할판을 가진 정방형주 주위의 유동장 특성 분석 (Characteristic analysis of flowfield around a square prism having a detached splitter plate using the PIV)

  • 노기덕
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권4호
    • /
    • pp.338-343
    • /
    • 2013
  • 본 연구는 후류측에 분리된 분할판(Detached splitter plate)을 설치한 경우 정방형주의 주위의 유동장 특성을 분할판의 폭과 정방형주 후면에서부터 분할판까지의 간격을 변수로 하여 PIV를 이용한 가시화실험으로 파악한 것이다. 그 결과를 요약하면 다음과 같다. 분할판 후류측에서 측정한 Strouhal 수는 분할판의 폭비 및 간격비가 증가할수록 감소했다. 분할판의 상부에는 시계방향의, 하부에는 반시계방향의 볼테스가 존재하였고, 이 볼텍스 영역의 크기는 분할판 폭비가 클수록 크게 나타났다. 분할판을 가진 정방형주 후류측에는 역류가 존재하였고, 이 역류의 크기는 분할판 폭비가 클수록 증가했다.

세라믹 볼을 이용한 판형열교환기 세정장치의 볼 회수율 측정 (The Measurements of Ball Recovery Rate for the Cleaning Apparatus in Plate Heat Exchanger Using Ceramic Ball)

  • 채희만;권정태;차동안;권오경
    • 동력기계공학회지
    • /
    • 제18권1호
    • /
    • pp.38-44
    • /
    • 2014
  • The objectives of this study are to measure the ball recovery rate of cleaning apparatus for plate heat exchanger. Ceramic ball is used for plate heat exchanger cleaning. The main components of cleaning apparatus are comprised of ball collector, ball trap, ejector, pump and plate heat exchanger. The ball recovery rate are obtained with change in recovery time and velocity of water. The results show that the ball recovery rate is slightly increased with increase in the recovery time and the velocity of water over 0.4 m/s in the straight flow. In the case of reverse flow, the ball recovery rate more increased than straight flow. The maximum ball recovery rate of the straight flow and reverse flow reach 83.97% and 86.61%, respectively, when the velocity and cleaning time are 0.5 m/s and 15min.

HMC05의 경구투여 소핵시험 및 복귀돌연변이 시험 (Micronucleus Test in Bone Marrow Cells and Bacterial Reverse Mutation Assay of HMC05)

  • 신흥묵
    • 대한본초학회지
    • /
    • 제25권2호
    • /
    • pp.137-144
    • /
    • 2010
  • Objectives : We investigated genetic toxicity of HMCO5 using the Micronucleus Test in bone marrow cells of mice and Bacterial Reverse Mutation Assay in plate incorporation method according to OECD Guidelines and KFDA Guidelines. Methods : 1. Micronucleus test: The male rats were divided into 5 groups, respectively; G(1), treated with distilled water: G(2), treated with 1250mg/kg HMC05: G(3), treated with 2500mg/kg HMC05, G(4), treated with 5,000mg/kg HMC05; G(5), treated with Cyclophosphamide $H_2O$. Sterilized distilled water and HMC05 were administered for two consecutive days. Cyclophosphamide $H_2O$ was administered once on the day of 2nd administration. 2. Bacterial Reverse Mutation Aassay: Experimental groups were divided into two groups: with S-9mix(+S) or without S-9mix(-S). Each group treated with sterilized distilled water only, HMCO5(62, 185, 556, 1,667, $5,000{\mu}g$/plate) and, positive vehicles(Sodium azide, 2-Aminoanthracene, 4-Nitroquinoline N-oxide, ICR 191), respectively. Results : HMC05 did not show any changes in the number of micronucleated polychromatic erythrocytes(MNPCE) among 200 polychromatic erythrocytes compare to negative control. However, there were significant (p<0.01) increase with CPA in MNPCE. In Bacterial Reverse Mutation Aassay, no significant increases in the number of revertant colonies compared to (삭제) negative control were detected in all concentrations of HMC05. Conclusions : These results indicate that HMC05 did not show any genotoxicity against in Micronucleus test and Bacterial Reverse Mutation Aassay.