• Title/Summary/Keyword: Reverse Osmosis Plant

검색결과 67건 처리시간 0.028초

Development and Applications of Membrane Technology in Korea

  • Noh, S.H.
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1995년도 추계 총회 및 학술발표회
    • /
    • pp.74-79
    • /
    • 1995
  • In the last 10 years, membrane science and technology in Korea have grown fast in terms of basic research and process applications. Even the first large commercial membrane plant in Korea was an ion-exchange membrane process built in 1975 for the production of table salt with an annual capacity of 150,000 tons of salt, membrane processes could not draw general interests from industry not until 1987 when a reverse osmosis plant for the production of process water with a capacity of 10,000 m$^3$/day was built by Kugdong Petroleum Co. Today, the production of water by RO over the capacity of 140,000 m$^3$/day is in operation or under construction in Korea. Consumption of ultra pure water increases sharply in recent years mainly due to the rapid expansion of semiconductor industry and the introduction of ultra high pressure boilers for power plants.

  • PDF

정삼투를 이용한 하수의 재이용에서 혼합비료 유도용액의 성능 평가 (Evaluating the Performance of Blended Fertilizer Draw Solution in Reuse of Sewage Water Using Forward Osmosis)

  • 김승건;이호원
    • 공업화학
    • /
    • 제31권1호
    • /
    • pp.90-96
    • /
    • 2020
  • 본 연구는 혼합비료를 유도용액으로 하는 정삼투 기술을 하수에 적용하여 하수를 재이용하기 위한 연구이다. 이를 위하여 본 연구에서는 J 하수처리장의 1차 침전지 유입수와 유출수, 그리고 2차 침전지 유출수를 각각 처리 대상으로 하였다. 평균 수투과선속은 KCl + NH4Cl > KCl + NH4H2PO4 > KCl + (NH4)2HPO4의 순서로 크게 나타났으며, 역용선속은 KCl + NH4H2PO4 < KCl + NH4Cl < KCl + (NH4)2HPO4의 순서로 작게 나타났다. 혼합비료의 종류에 관계없이 2차 침전지 유출수의 수투과선속이 가장 높게 나타났다. KCl과 NH4H2PO4의 혼합 유도용액은 비료의 주요 성분인 질소, 인 및 칼륨을 모두 포함하고 있을 뿐 아니라 낮은 비역용질 선속을 갖고 있어서 하수의 재이용에 가장 유용하게 사용될 수 있을 것으로 판단되었다. KCl과 NH4H2PO4의 혼합 유도용액을 사용한 경우, 2차 침전지 유출수에 대한 평균 수투과선속과 역용질선속은 각각 12.14 LMH과 0.012 mol/㎡s이었다.

역삼투막을 이용한 제철폐수 처리 시 실리카 및 철 이온이 막 폐색에 미치는 영향 (Effect of Silica and Iron on the Fouling Tendency of Reverse Osmosis Membrane for Treating Wastewater from an Integrated Iron and Steel Mill)

  • 오희완;이채영
    • 대한토목학회논문집
    • /
    • 제38권4호
    • /
    • pp.547-553
    • /
    • 2018
  • 제철공정에서 물 사용량은 조강 생산량 당 $4.2m^3$/톤으로 많으며 폐수의 성상에 있어서 철, 망간 등 물질을 포함하고 있다. 특히 동남아시아의 일부지역은 다른 지역에 비해 실리카의 농도가 높다. 실리카는 물 재이용을 위한 막 처리과정에서 막 폐색의 주된 요인으로 작용하기 때문에 물 재이용에 있어 제한요소이다. 실리카 농도가 높은 제철폐수의 경우 철 이온과 실리카에 의한 규산제일철 형성에 의한 막 폐색 발생우려가 높다. 본 연구는 두 가지 경우에 대하여 파일럿 테스트를 실시하였다. 제철폐수 처리수의 경우 RO 파일럿 테스트는 플럭스 15.9LMH 및 18.8LMH로 112일 동안 수행하였다. 실험결과 플럭스의 변동 및 차압(TMP, trans membrane pressure)이 크게 나타났으며, 최소 투과율은 78%로 낮아 막 폐색 가능을 확인할 수 있었다. 오탁수 처리수를 이용한 RO 파일럿 테스트는 플럭스 18.8LMH로 46일 동안 수행하였으며, 철 이온 농도는 0.11mg/l으로 폐수 처리수보다 낮았다. 실험결과 철 이온 등의 농도가 낮은 오탁수 처리수는 플럭스 및 TMP의 변동이 작아 RO 막 폐색현상이 폐수 처리수보다 저감됨을 알 수 있었다. 유입수 조건이 실리카, 철 및 망간 농도가 높은 경우 MF 전처리를 통해 RO 막 폐색현상을 저감시킬 수 있었다.

침지형 한외여과 막공법과 역삼투 공법을 이용한 하.폐수처리 (Wastewater Treatment Using Ultrafiltration (UF) and Reverse Osmosis (RO) Process)

  • 최희정;박연종;이승목
    • 대한환경공학회지
    • /
    • 제34권10호
    • /
    • pp.678-683
    • /
    • 2012
  • 세계적인 물부족을 해결하는 대안 중의 하나는 하수 재이용이다. 본 연구는 A시의 하수를 UF와 RO 공법으로 처리하여 인근지역의 공업용수로 재사용이 가능한지의 여부를 확인하고자 하였다. A시의 하수를 UF와 RO로 처리한 결과 Na, Mg, Cl, Ca, Mn, $PO_4$, $SO_4$ 등은 원수 대비 97% 이상의 높은 처리 효율을 보였으나, $NH_4$-N, TN, $NO_3$-N, BOD등의 영양염류는 각각 35.71%, 85.21%, 87.05% 그리고 56%로 상대적으로 낮은 제거율을 보였다. 그러나 영양염류는 원수 자체의 함유량이 소량 이여서 하수 처리수 공업용수 재이용수질 권고 기준을 만족하는데 문제가 없었다. 그 외의 측정항목 또한 하수 처리수 공업용수 재이용수질 권고 기준을 만족하여 인근지역의 공업용수로 재사용에는 문제가 없을 것으로 예상된다.

냉연공장 폐수재이용을 위한 3단 역삼투시스템에서 각 단별 투과특성 연구 (Permeation Property of Each Stage in Three Stage Reverse Osmosis System for Cold-mill Wastewater Reuse)

  • 박영규
    • 멤브레인
    • /
    • 제9권4호
    • /
    • pp.209-214
    • /
    • 1999
  • 본 연구의 목적은 냉연공장 폐수재이용을 위해 3단 역삼투시스템 사용시 각단에서의 투과특성을 조사하는 것이다 판틀형 모듈 7개를 사용하여 회수율이 75% 가 되도록 3단 (배열 : 4+2+1) 으로 구성하여 장기간에 걸친 pilot test를 통해 막오염 진행에 따른 각 단에서의 유량 및 수질변화를 조사하였다 실험결과 각 단 모듈 1개당 평균 투과수량은 운전초기에는 1단, 2단, 3단의 순서로 많았으나 운전시간이 경과하며 막오염이 진행됨에 따라 1단은 감소하는 반면 2단은 거의 변화가 없고 3단의 투과수량은 증가하였다 즉 막오염은 주로 1단에서 발생하며 점차 2단. 3단으로 진행되는 것을 확인할수 있었다. 한편 투과수 수질은 예상한 것과 같이 1단이 가장 우수하였고 다음으로는 2단, 3단의 순서였으며 막오염에 영향을 받지않았다.

  • PDF

SWRO 해수담수화 공정에서 전처리된 수질조건이 SDI에 미치는 영향 (Effect of Pretreated Seawater Quality on SDI in SWRO Desalination Process)

  • 손동민;강임석
    • 대한환경공학회지
    • /
    • 제35권3호
    • /
    • pp.200-205
    • /
    • 2013
  • 전처리 공정은 막의 오염 정도를 제어할 수 있는 유일한 방법이다. 막의 오염 현상은 피할 수 없는 중요한 문제이며 RO 공급수로 적합한 전처리 공정의 선택이 중요하다. 본 연구는 pH, 해수의 탁도, 수온, 응집제 주입량 그리고 SDI 측정 막재질과 같은 SDI 값에 영향을 미치는 인자들을 평가 하기위해 수행되었다. 그 결과 해수의 탁도는 여과수의 SDI 값에 약간의 영향을 미친것으로 조사되었다. 0.45 um 공극 크기를 가지는 SDI 측정 막은 소수성 막 보다 동일한 재질의 친수성 막을 이용하는 것이 분석 결과의 신뢰성과 재현성을 확보할 수 있었다. pH 7.0 이하의 조건에서 pH가 감소할수록 SDI 값은 증가한 것으로 나타났다. 그리고 수온은 SDI 값은 큰 영향을 미친것으로 조사되었다.

Development of the Pilot System for Radioactive Laundry Waste Treatment Using UV Photo-Oxidation Process and Reverse Osmosis Membrane

  • Park, Se-Moon;Park, Jong-Kil;Kim, Jong-Bin;Shin, Sang-Woon;Lee, Myung-Chan
    • Nuclear Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.506-511
    • /
    • 1999
  • The pilot system for radioactive liquid laundry waste was developed with treatment capacity, 1ton/hr and set up in the Yong Kwang unit #4. The system is composed of tank module, RO systems and a UV/$H_2O$$_2$photo-oxidation unit. The RO system consists of the BW unit (low-pressure RO for brackish water desalination) and the SW unit (high-pressure RO for seawater desalination). The BW unit possesses 4 RO membranes and it can reduce the feed water volume down to 1/10. This concentrated feed water can be reduced again up to 1/10 in its volume in the SW unit composed of 4 RO membranes. The UV/$H_2O$$_2$ photo-oxidation process unit was used for the detergent degradation. The operation of the pilot system was carried out and verified in its capability through the continuous operation and concentration operation using the actual liquid waste from the power plant. The design criteria and data for industrialization were yielded. The efficiency of the UV/$H_2O$$_2$ photo-oxidation process and the optimum operational procedure were evaluated. The decontamination factors for radioactive cobalt and cesium were measured. This on-site test showed the experimental result in the DF$\geq$300 and volume reduction factor$\geq$100.

  • PDF

최소수리 블록교체 모형을 활용한 상태기반 보전 정책 연구 (A Study on Condition-based Maintenance Policy using Minimum-Repair Block Replacement)

  • 임준형;원동연;심현수;박철홍;고관주;강준규;김용수
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제18권2호
    • /
    • pp.114-121
    • /
    • 2018
  • Purpose: This study proposes a process for evaluating the preventive maintenance policy for a system with degradation characteristics and for calculating the appropriate preventive maintenance cycle using time- and condition-based maintenance. Methods: First, the collected data is divided into the maintenance history lifetime and degradation lifetime, and analysis datasets are extracted through preprocessing. Particle filter algorithm is used to estimate the degradation lifetime from analysis datasets and prior information is obtained using LSE. The suitability and cost of the existing preventive maintenance policy are each evaluated based on the degradation lifetime and by using a minimum repair block replacement model of time-based maintenance. Results: The process is applied to the degradation of the reverse osmosis (RO) membrane in a seawater reverse osmosis (SWRO) plant to evaluate the existing preventive maintenance policy. Conclusion: This method can be used for facilities or systems that undergo degradation, which can be evaluated in terms of cost and time. The method is expected to be used in decision-making for devising the optimal preventive maintenance policy.

유기물 농도가 낮은 고품질 정수 생산을 위한 고압막여과 공정 설계 시 고려사항 (Considerations to design high-pressure membrane system to produce high quality potable water with lower organic matter concentration)

  • 전종민;김성수;서인석;김수한
    • 상하수도학회지
    • /
    • 제34권6호
    • /
    • pp.473-480
    • /
    • 2020
  • High-pressure membrane system like nanofiltration(NF) and reverse osmosis(RO) was investigated as a part of water treatment processes to produce high quality potable water with low organic matter concentration through membrane module tests and design simulation. River water and sand filtration permeate in Busan D water treatment plant were selected as feed water, and NE4040-90 and RE4040-Fen(Toray Chemical Korea) were used as NF and RO membranes, respectively. Total organic carbon(TOC) concentrations of NF and RO permeates were mostly below 0.5 mg/l and the average TOC removal rates of NF and RO membranes were 93.99% and 94.28%, respectively, which means NF used in this study is competitive with RO in terms of organic matter removal ability. Different from ions rejection tendency, the TOC removal rate increases at higher recovery rates, which is because the portion of higher molecular weight materials in the concentrated raw water with increasing recovery rate increases. Discharge of NF/RO concentrates to rivers may not be acceptable because the increased TDS concentration of the concentrates can harm the river eco-system. Thus, the idea of using NF/RO concentrate as the raw water for industrial water production was introduced. The design simulation results with feed water and membranes used in this work reveal that the raw water guideline can be satisfied if the recovery rate of NF/RO system is designed below 80%.

전처리 MF의 다양한 역세 공정을 적용한 하수재이용 파일럿 플랜트 연구 (Study of MF membrane as pretreatment option using various backwash process from wastewater reuse pilot plant)

  • 박광덕;박찬수;이창규;김종오;최준석
    • 상하수도학회지
    • /
    • 제30권3호
    • /
    • pp.335-341
    • /
    • 2016
  • Various studies have forwarded an outstanding wastewater effluent treatment systems toward securing sustainable supply of water sources. In this paper, a broad overview of the performance of MF membrane as pretreatment option for wastewater reuse will be presented based on the literature survey and experiments conducted over the wastewater reuse pilot plant. The pilot plant was operated with a continuous data acquisition for about 300days under various chemical enhanced backwash (CEB) system with subsequent treated water quality analysis. Accordingly, assessment of the effluent revealed that the pretreated water is suitable enough to be used as an input for Reverse Osmosis (RO) unit and significant effect of CEB and concentration of NaOCl is also conceived from the analysis. Moreover, it's also observed that the application of various CEB condition over long operational hours induced a constant declination of overall performance of MF membrane.