• Title/Summary/Keyword: Return water

Search Result 528, Processing Time 0.023 seconds

Evaluation of Drought Events Using the Rectangular Pulses Poisson Process Model (구형펄스모형을 이용한 가뭄사상의 평가)

  • Yoo, Chul-Sang;Kim, Dae-Ha
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.4 s.165
    • /
    • pp.373-382
    • /
    • 2006
  • In this study a theoretical drought severity-duration-frequency analysis is performed based on a simple Rectangular Pulses Poisson Process Model(RPPM). Data set with various durations are prepared for a given truncation level, whose statistics are then derived to be used for parameter estimation. These parameters are then used for the theoretical drought severity-duration-frequency analysis. The analysis is considered for two cases; one is to consider the overlap probability and the other is not. The drought severity of considering the overlap probability increases more as the return period increases. However, the overlap probability itself decreases as the duration increases, which is because the occurrence probability of events decreases as the duration increases. Also, if the duration increases, the events rarely or even not occur, since parameters of the model cannot be estimated in those cases, so the drought severity may not be computed. This is an obvious limitation of the simple RPPM. In this study the return periods of the important drought events occurred in Seoul are estimated using the results of the study. If the return period of an event is assumed to be the longest one among those with various durations, the return periods of some important event in Seoul are estimated to be between 14 and 35 years. These return periods are not so long to indicate that these droughts can occur frequently.

Feasibility Study of Wastewater Reuse for the Vegetable Farming in Jejudo (제주도 밭작물의 농업용수 재이용 타당성 평가)

  • Seong, Choung-Hyun;Kang, Moon-Seong;Jang, Tae-Il;Park, Seung-Woo;Lee, Kwang-Ya;Kim, Hae-Do
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.1
    • /
    • pp.27-32
    • /
    • 2009
  • The objective of this study is to assess the feasibility of wastewater reuse for the vegetable farming. The study region, about 250 ha in size, is located on the west coast of Jejudo, Korea. Major agricultural products of the study area are the cabbage, broccoli, garlic and onion. To confirm the feasibility of wastewater reuse, the drought duration and the water requirement analysis were conducted respectively. The average annual precipitation of the study region (1,121 mm) was smaller than that of Jeju island (1,975 mm). The drought duration for a ten-year return period in October through November was more than 20 days. The water requirement for irrigation was calculated by the FAQ Penman-Monteith method which took into account the cultivated crops, planting system, and meteorological conditions of the study region. The water requirement for a ten-year return period was estimated 4.7 mm/day and the water demand for irrigation was $4,584\;m^3/day$. As a result, the irrigation water for the crops was insufficient during their breeding season, especially in October through November. Thus, the result indicated that the study region required the alternative water supply such as wastewater reuse during the non-rainy season. As drought continues to place considerable stress on the availability of fresh water supplies in the study region, irrigation with reclaimed wastewater will play an important role in helping to meet future water demands.

Water Supply Capacity of the Keum River Barrage Dam Based on Inflow Scenario (유입량 시나리오에 따른 금강하구둑의 용수공급능력 분석)

  • Noh, Jae-Kyoung;Kim, Dae-Hyun
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.499-502
    • /
    • 2003
  • Using the daily water balance model of the Keum River Barrage Dam, water supply capacity was analyzed. The scenario of reservoir inflow was selected to case with Daechung dam, case with no dam, case with Yongdam dams. Runoffs in 12 sub watersheds were simulated by the DAWAST model considered return flows.

  • PDF

Molar Ratio Control Scheme Based on Hideout Return Test for Ulchin Nuclear Power Plant Unit 3 (울진 3호기 잠복방출시험을 이용한 몰비 조절방안)

  • Kim, Y. H.;Y. N. Suh;Lee, S. S.;Kim, E. K.;Y. J. Pi
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.11a
    • /
    • pp.125-130
    • /
    • 1999
  • Corrosion of steam generator tubes is the major issue affecting selection of secondary water chemistry parameters. The objective of secondary side water chemistry control is to minimize corrosion damage and to thereby maximize the reliability and economic performance of the secondary system. To achieve this objective, the water chemistry has to be compatible with all parts of the system including steam generators.(Omitted)

  • PDF

A Study on Improved Operation of Apartment Heating System in a Machine Room (공동주택 기계실 난방설비 운전 개선 연구)

  • Seo, Jeong-Ah;Shin, Younggy;Kim, Yong-Ki;Lee, Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.1
    • /
    • pp.38-42
    • /
    • 2017
  • This study proposes an idea for energy saving in apartment machine rooms. A conventional district heating system is equipped with constant-flow pumps and bypass valves to regulate pump differential pressure. Each family unit is equipped with a constant-flow on/off valve. This leads to excessive hot water circulation and a high return temperature. To reduce energy loss, this study assumes that each family unit is renovated with a heating valve which regulates the return temperature at $35^{\circ}C$. The hot water supply pump is also replaced with a pump with an inverter to vary flow rate. Expected energy savings is then estimated from field test data. According to the results, pump electricity consumption was reduced by 6,100 kWh for a family unit building over about half a year. The supply temperature can also be lowered by $5^{\circ}C$, which can contribute to a production of electricity of 10.3 kWh/ton of hot water.

Measurement and Simulation of Heating Energy for Apartments with District Heating (지역난방 아파트에 대한 난방에너지 실측 및 시뮬레이션)

  • Lee, Eun Ju;Lee, Doo Young;Hong, Hiki;Kim, Young Kyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.572-578
    • /
    • 2014
  • Heating energy was measured in an apartment housing unit with a district heating system, varying the kind of hot water distributors. Ondol coils passing through a living room raised the temperature of the room where the heating was turned off. Including this characteristic of Ondol heating into the modeling, we performed simulations and showed a verification by comparison with the results of measurements. As a result, a main flow control method, which changes hot water flow rate supplied to a housing unit according to the thermal load, can reduce the supplied flow rate and lower the return temperature, compared with a constant flow method. That can result in decreased heat loss in utility-pipe conduits even though the heating energy supplied is almost the same. An outdoor reset control that raises the temperature of the supplied hot water if the outdoor temperature falls has the effect of a quicker response in heating than the reduced flow rate and return temperature.

Estimation of the thermal performance on the double slab floor with supplying air (급기가 되는 이중바닥 구조체의 열 성능 평가)

  • Cha, Kwang-Seok;Park, Myung-Sig;Lee, Dae-Woo;Nam, Woo-Dong
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.866-871
    • /
    • 2006
  • Recently according to the fashion of well-being, the case study of under floor heating system type for residential space is increasing. Specially double slab floor system can make several roles as reducing the acoustic noises and also supplying fresh air through the gap. So in present study floor heating performance was examined with various location of the space in the case of floor supply air and ceiling supply air. In both cases return air went out through ceiling opening. As one of the result is that when using the heat pipe type floor heating system the temperature difference between supply and return water was $15.2^{\circ}C$, but in case of commercial type floor heating system the temperature difference was $5.3^{\circ}C$ when the supply water temperature was $50^{\circ}C$.

  • PDF

The Performance Characteristics of Anti-Surge Devices for High Head Cooling Water Systems in 1,000 MW Thermal Power plants (고수두 1,000 MW 석탄화력발전소 냉각수계통 수격방지장치의 성능특성)

  • Kim, Keun-Pil;Yoo, Hoseon
    • Plant Journal
    • /
    • v.15 no.4
    • /
    • pp.36-42
    • /
    • 2019
  • In recent, according to the tightening of environment regulation policy, the height of the site of the power plant is increased and the length of the cooling water pipe is increased. This has a serious impact on the stability of the plant. This study analyzes the transient phenomenon using LIQT 7.2, an unsteady state one-dimensional analysis software, to secure the stability of 1,000 MW high-capacity coal-fired power plant cooling water system with high head. To prevent water hammer, The effects on performance characteristics were predicted by individual and combination application. The surge pressure of the cooling water which occurs when the pump was stopped without installing the anti-surge devices was the largest at the pump outlet side. The most effective and simple way to reduce surge pressure in these cooling water systems is to combine a vacuum breaker with a hydraulic non-return valve, which is an essential device for pump protection.

Development of a Hydrologic System for Simulating Daily Water Storage in an Estuary Reservoir

  • Noh, Jae-Kyoung
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.7
    • /
    • pp.1-10
    • /
    • 2003
  • In order to analyze the water supply capacity in an estuary reservoir, a system composed of daily water balance model and daily inflow model was developed. The agricultural water demands to paddy fields, domestic water demands to residential areas, and industrial water demands to industrial complexes were considered in this daily water balance model. Likewise, the outflow volume through sluice gates and inside the water level at the start of the outflow was initially conditioned to simulate estuary reservoir storage. The DAWAST model (Noh, 1991) was selected to simulate daily estuary reservoir inflow, wherein return flows from agricultural, domestic, and industrial water were included to simulate runoff. Using this system, the water supply capacity in the Geum River estuary reservoir was analyzed.

Hydrologic Scenarios for Sustained Drought in Han River (한강수계 장기 가뭄 수문시나리오 개발)

  • Lee, Gwang-Man;Cha, Hyung-Sun;Lee, Seung-Yoon
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.6
    • /
    • pp.629-641
    • /
    • 2008
  • Many studies on sustained droughts have often been limited to the analysis of historic flow series. A major disadvantage in this approach can be described as the lack of long historic flow records needed to obtain a significant number of drought events for the analysis. To overcome this difficulty, one of the present study idea is to use synthetically generated hydrologic series. A methodology is presented to develop flow series based on the probabilistic analysis of the stochastic properties of the observed flows. The method can be utilized to generate a flow series of desired length so as to include many multiyear drought events within the process. In this paper, a concept of creating multiyear drought scenarios is introduced, and its development procedure is illustrated by a case study of the water supply system in Han River Basin. Also, it was found that the generated flow series can be reliably used to predict the long drought duration and sustained drought hydrologic scenarios within a given return period.