• Title/Summary/Keyword: Return pump

Search Result 47, Processing Time 0.02 seconds

Matching Diffuser Vane with Return Vane Installed in Multistage Centrifugal Pump

  • Kawashima, Daisuke;Kanemoto, Toshiaki;Sakoda, Kazuyuki;Wada, Akihiro;Hara, Takashi
    • International Journal of Fluid Machinery and Systems
    • /
    • 제1권1호
    • /
    • pp.86-91
    • /
    • 2008
  • The effects of the diffuser vane on the performances of the multistage centrifugal pump were investigated experimentally, taking account of the interactions among the diffuser vane, the return vane, and the next stage impeller. It is very important to match well the diffuser vane with the return vane, for improving the hydraulic efficiency of the pump. The efficiency may be more improved by making the cross-sectional area of the channel from the diffuser vane outlet to the return vane inlet larger, as much as possible.

Return Vane Installed in Multistage Centrifugal Pump

  • Miyano, Masafumi;Kanemoto, Toshiaki;Kawashima, Daisuke;Wada, Akihiro;Hara, Takashi;Sakoda, Kazuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제1권1호
    • /
    • pp.57-63
    • /
    • 2008
  • To optimize the stationary components in the multistage centrifugal pump, the effects of the return vane profile on the performances of the multistage centrifugal pump were investigated experimentally, taking account of the inlet flow conditions for the next stage impeller. The return vane, whose trailing edge is set at the outer wall position of the annular channel downstream of the vane and which discharges the swirl-less flow, gives better pump performances. By equipping such return vane with the swirl stop set from the trailing edge to the main shaft position, the unstable head characteristics can be also suppressed successfully at the lower discharge. Taking the pump performances and the flow conditions into account, the impeller blade was modified so as to get the shock-free condition where the incidence angle is zero at the inlet.

원심다단펌프용 디퓨저-리턴채널의 유동특성 (Hydrodynamic Characteristics of Vaned-Diffuser and Return-Channel for a Multistage Centrifugal Pump)

  • 오형우
    • 한국유체기계학회 논문집
    • /
    • 제14권6호
    • /
    • pp.54-60
    • /
    • 2011
  • This paper presents the steady-state performance analysis of the first stage of a multistage centrifugal pump, composed of a shrouded-impeller, a vaned-diffuser and a return-channel, using the commercially available computational fluid dynamics (CFD) code, ANSYS CFX. The detailed flow fields in the vaned-diffuser with outlet in its side wall and the return-channel are investigated by the CFD code adopted in the present study. The effect of the vaned-diffuser with a downstream crossover bend and the corresponding return-channel on the overall hydrodynamic performance of the first stage pump has also been demonstrated over the normal operating conditions. The predicted hydrodynamics for the diffusing components herein could provide useful information to match the inlet blade angle of the next stage impeller for improving the multistage pump performances.

DC모터형 연료펌프를 이용한 연료공급방식별 LPG성상에 따른 LPi엔진 연소 및 배출가스 특성 (LPi Engine Combustion and Emission Characteristics Depending on LPG Properties from Various Fuel Supply Types by Using DC Motor Type Fuel Pump)

  • 김주원;황인구;명차리;박심수
    • 대한기계학회논문집B
    • /
    • 제32권12호
    • /
    • pp.907-914
    • /
    • 2008
  • This study is mainly focused on the assessment of return, semi return, and returnless fuel supply system for an LPi engine. In order to compare the return type with returnless one with various LPG blends, combustion analysis and cyclic THC emission characteristic were tested at the part load operating condition of the LPi engine. Considering heat balance of each fuel supply systems, pressure and temperature increment of return type showed lower at the fuel rail during idle warm up operation. However, those of returnless type at LPG tank maintained stable and slow increment because the heat transfer from the LPi engine was minimized. Finally, hot restartability of each fuel supply systems were evaluated with the various LPG blends and fuel temperatures. As a result, semi return type has equivalent performance to return type considering combustion and emission characteristic, hot restartability performance for LPi engine.

Quantifying Energy Consumption to the Level of Service Pressure in Water Distribution Network

  • Marlim, Malvin S.;Choi, Jeongwook;Kang, Doosun
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2022년도 학술발표회
    • /
    • pp.458-458
    • /
    • 2022
  • It is essential to reduce global carbon emissions, mainly from energy use. The water supply and distribution sector is a vital part of human society and is one of the primary energy consumers. The procurement and distribution of water require electricity to operate the pump to deliver water to users with sufficient pressure. As the water users are spatially distributed over a wide area, the energy required to deliver water to each user differs depending on the corresponding supplying element (reservoir, tank, pipe, pump, and valve). This difference in energy required for each user also comes with a difference in pressure availability which affects the level of service for individual users and the whole network. Typically, there is a disproportion where users close to the source experience excessively high pressure with low energy consumption. In contrast, remote users need more energy to get the minimum pressure. This study proposes the Energy Return Index (ERI) to quantify the pressure return from particular energy consumption to supply water to each node. The disproportionality can be quantified and identified in the network using the proposed ERI. The index can be applied to optimize the network elements such as pump operation and tank location/size to reach a balanced energy consumption with the appropriate level of service.

  • PDF

공동주택 기계실 난방설비 운전 개선 연구 (A Study on Improved Operation of Apartment Heating System in a Machine Room)

  • 서정아;신영기;김용기;이태원
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.38-42
    • /
    • 2017
  • This study proposes an idea for energy saving in apartment machine rooms. A conventional district heating system is equipped with constant-flow pumps and bypass valves to regulate pump differential pressure. Each family unit is equipped with a constant-flow on/off valve. This leads to excessive hot water circulation and a high return temperature. To reduce energy loss, this study assumes that each family unit is renovated with a heating valve which regulates the return temperature at $35^{\circ}C$. The hot water supply pump is also replaced with a pump with an inverter to vary flow rate. Expected energy savings is then estimated from field test data. According to the results, pump electricity consumption was reduced by 6,100 kWh for a family unit building over about half a year. The supply temperature can also be lowered by $5^{\circ}C$, which can contribute to a production of electricity of 10.3 kWh/ton of hot water.

한국에 있어서의 히이트 펌프계의 최적 설계 조건에 관한 연구 (A Study on Optimum Design Condition for 'HEAT PUMP' System in Korea)

  • 최영배
    • 대한설비공학회지:설비저널
    • /
    • 제10권4호
    • /
    • pp.304-315
    • /
    • 1981
  • This paper presents, the result of the study for the fluctuant temperature of the out-side air adopting the heat pump system in seoul, Taejean, Taegu, Busan and Jejeu among principle cities in korea for the purpose of checking the heating capacity, Heat pump capacity (outlet capacity), Coefficient of performance and running cost in comparison with the supporting the energy for the boiler's operation. According to the supply temperature changes of the out door coil by the out side air-return air mixing ratio, the Coefficient of performance is increased from 3. 1 to 5.0. Particularly, in Taegu, it is necessary to adopt the heat pump system against the supplement heat supply on the full outside air intake in January of the heating period, and it was recognized that the running cost is cheaper than that of the Boiler use. At the same time, if it is able to get $25\%$ of return air of the inside in the Seoul, it could be saved its costs when we use the supplementary boiler. And I think it is necessary to the development.

  • PDF

고압 다단 펌프의 레이디얼 디퓨저에 대한 연구 (Study on the Radial Diffuser of Multistage High Pressure Pump)

  • 김덕수;산자르;박원규
    • 대한기계학회논문집B
    • /
    • 제40권11호
    • /
    • pp.727-736
    • /
    • 2016
  • 본 연구에서는 복합화력 화력 발전소용 고압 다단펌프의 레이디얼 디퓨저 형상에 따른 펌프의 성능(양정, 효율)변화를 수치 해석적으로 분석하였다. 레이디얼 디퓨저 설계 변수는 크게 디퓨저 베인수, 디퓨저 외경비($D_4/D_3$), 리턴채널 출구각도(${\alpha}_6$), 압력회복계수($C_p$) 등으로 선정하였다. 수치해석 결과 디퓨저 외경비가 큰 경우 양정 및 효율이 가장 크게 예측되었으며, 리턴채널의 출구각도(${\alpha}_6$)가 60도인 경우 디퓨저 출구에서의 Pre-Swirl로 인해 출구각도가 90도인 것에 비해 양정이 저하되는 것을 알 수 있다.

MOVING-ACTUATOR TYPE 인공심장의 심박출 조절에 대한 자동 제어방법 (Automatic Control System on Cardiac Output Regulation for the Moving Actuator Type Total Artificial Heart)

  • 김원곤
    • Journal of Chest Surgery
    • /
    • 제28권6호
    • /
    • pp.542-548
    • /
    • 1995
  • The goal of this study is to develop an effective control system for cardiac output regulation based upon the preload and afterload conditions without any transducers and compliance chambers in the moving actuator type total artificial heart. Motor current waveforms during the actuator movement are used as an input to the automatic control algorithm. While the current waveform analysis is performed, the stroke length and velocity of the actuator are gradually increased up to the maximum pump output level. If the diastolic filling rate of either right or left pump begins to exceed the venous return, atrial collapse will occur. Since the diastolic suction acts as a load to the motor, this critical condition can be detected by analyzing the motor current waveforms. Every time this detection criterion is met, the control algorithm decreases the stroke velocity and length of the actuator step by step just below the critical detection level. Then, they start to increase. In this way the maximum pump output under given venous return can be achieved. Additionally the control algorithm provides some degree of afterload sensitivity. If the aortic pressure is detected to exceed 120 mmHg, the stroke length and velocity decrease in the same way as the response to the preload. Left-right pump output balance is maintained by proper adjustment of the asymmetry of the stroke angle. In the mock circulatory test, this control system worked well and there was a considerable range of stroke volume difference with adjustment of the asymmetry value. Two ovine experiments were performed. It was confirmed that the required cardiac output regulation according to the venous return could be achieved with adequate detection of diastolic function, at least in the in vivo short-term survival cases[2-3 days . We conclude that this control algorithm is a promising method to regulate cardiac output in the moving actuator type total artificial heart.

  • PDF

심야전기보일러 대체 Heat Pump의 경제성 분석 (Analysis on Economic Feasibility of Electric Night Storage Heat Pump as a Substitution of a Heater)

  • 정훈;조종영;이철희
    • 한국기계기술학회지
    • /
    • 제13권3호
    • /
    • pp.119-124
    • /
    • 2011
  • Electric night storage heater was introduced and disseminated for power grid balancing and efficient management of power generation facility. But fuel cost for heating has been increased rapidly while the cost of electricity increased slightly. This abnormal rate system caused peak load in winter at last. To solve this problem, application of an air source heat pump was suggested. In the study, the effect of replacing night heater by heat pump and the economics were analysed. In addition the expectation of prospect of heat pump penetration was simulated based on surveyed and investigated data. As a result, fund supporting as well as institutional backing was needed for effective propagation and return of investment.