• 제목/요약/키워드: Retrograde

Search Result 500, Processing Time 0.029 seconds

TSSG-pulling of Sillenite $Bi_{12}TiO_{20}$ for EOS Application

  • Miyazawa, Shintaro
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1999.06a
    • /
    • pp.227-250
    • /
    • 1999
  • The reproducibility of successive growth of Bi12TiO20(BTO) single crystals using a top-seeded solution growth (TSSG) pulling method was evaluated by measuring the lattice constants and their standard deviations. A substantial phase diagram in the region close to the stoichiometric BTO was established experimentally for this purpose, and the existence of a retrograde solid solution close to a BTO was clarified. It was emphasize that a starting solution, with a 10.0~10.1 mol% TiO2 concentration, results in large single crystals with a highly homogeneous lattice constant of within $\pm$1x10-4$\AA$, when the solidified fraction of the grown crystal is less than about 45%. A wavelength dispersion of refractive index was measured for the first time, an it was verified that the refractive index of BTO is larger than that of BSO(Bi12TiO20), allowing the voltage sensitivity of EOS higher than the case with BSO as a probe head.

  • PDF

Study for portable bladder function monitoring system (휴대용 방광기능 검사 장치에 대한 연구)

  • Kim, K.S.;Lee, S.O.;Lee, G.S.;Lee, T.H.;Kim, G.H.;Kim, H.J.;Jang, C.H.;Yoon, S.I.;Kim, C.H.;Chae, H.C.;Song, C.G.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.379-381
    • /
    • 2005
  • Urodynamics describes a collection of tests designed to evaluate lower urinary tract function and can be performed using retrograde filling of the bladder within a room. In this study, we designed and calibrated the potable urodynamics monitoring system using DSP chip (TMS320VC33, Texas InstrumentTM, U.S.) and obtained signals of bladder(Pves) and bladder neck pressure(Pneck) and EMG using calibration kit (DPT9022K0122, MedtronicsTM, U.s,). This system monitor spontaneous urination during daily life and can make patients more comportable.

  • PDF

Analog Performance Enhancement of Digital CMOS for SOC Application (SOC를 위한 Digital CMOS 소자의 Analog Performance 개선)

  • 지희환;김용구;왕진석;박성형;이희승;강영석;김대병;이희덕
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.1003-1006
    • /
    • 2003
  • 본 논문에서는 sub-micron 소자에서 SCE(Short Channel Effect) 억제를 위한 Halo 와 SSR(Super Steep Retrograde Well) 적용에 따른 analog 특성의 열화를 석하고 이를 개선하기 위해 Twist 이온주입과 In, Sb Halo 를 채택하였다. Analog 특성은 CMOS 의 amplifier 과 Comparator 로의 사용을 고려해 Drain Rout과 Early voltage를 이용해 나타내었으며 Digital 성능을 함께 고려하였다. 실험결과 NMOS 의 경우 45 twist Halo 조건에서, PMOS의 경우 As보다 Sb를 Halo 로 적용하는 경우 더 우수한 analog 특성을 나타내었다.

  • PDF

초 저 소비전력 및 저 전압 동작용 FULL CMOS SRAM CELL에 관한 연구

  • 이태정
    • The Magazine of the IEIE
    • /
    • v.24 no.6
    • /
    • pp.38-49
    • /
    • 1997
  • 0.4mm Resign Rule의 Super Low Power Dissipation, Low Voltage. Operation-5- Full CMOS SRAM Cell을 개발하였다. Retrograde Well과 PSL(Poly Spacer LOCOS) Isolation 공정을 사용하여 1.76mm의 n+/p+ Isolation을 구현하였으며 Ti/TiN Local Interconnection을 사용하여 Polycide수준의 Rs와 작은 Contact저항을 확보하였다. p-well내의 Boron이 Field oxide에 침적되어 n+/n-well Isolation이 취약해짐을 Simulation을 통해 확인할 수 있었으며, 기생 Lateral NPN Bipolar Transistor의 Latch Up 특성이 취약해 지는 n+/n-wellslze는 0.57mm이고, 기생 Vertical PNP Bipolar Transistor는 p+/p-well size 0.52mm까지 안정적인 Current Gain을 유지함을 알 수 있었다. Ti/TiN Local Interconnection의 Rs를 Polycide 수준으로 낮추는 것은 TiN deco시 Power를 증가시키고 Pressure를 감소시킴으로써 실현할 수 있었다. Static Noise Margin분석을 통해 Vcc 0.6V에서도 Cell의 동작 Margin이 있음을 확인할 수 있었으며, Load Device의 큰 전류로 Soft Error를 개선할수 있었다. 본 공정으로 제조한 1M Full CMOS SRAM에서 Low Vcc margin 1.0V, Stand-by current 1mA이하(Vcc=3.7V, 85℃기준) 를 얻을 수 있었다.

  • PDF

Diagnosis of Subclavian Steal: Contrast Enhanced 3D MR Angiography vs 2D TOF

  • 이호규;김건언;최중곤;서대철
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.136-136
    • /
    • 2001
  • Purpose: Subclavian steal refers to the retrograde flow of blood in a vertebral artery that supplies t ipsilateral shoulder and arm caused by proximal subclavian artery stenosis or occlusion. T purpose of this exhibit is to demonstrate MR findings of subclavian steal on contrast-enhanc 3D (CE 3DMRA) and 2D TOF MR angiography. Method: Four patients(men 3 and women 1, age: 28-78years) with subclavian steal obtained both CE 3DMRA and digital subtraction angiography(DSA) including subclavian arterie Sequential imaging was undertaken during first pass after double dose of Gd-DTPA (0 mM/kg) Injected by a power injector. Coronal source images were obtained with coronal D-fast low angle shot sequence(TR/TE/flip angle=3.8/l.3/35, acquisition time= 10sec/one measurement). Precontrast imaging was subtracted from enhanced images and maximu intensity projection was done. 2D time-of-flight MR angiography(2D TOF) of the carot bifurcation was added in all cases with post-saturation. All studies were review retrospectively.

  • PDF

Inquiry into the Laboratory Diagnostic Tests in Larygopharyngeal Reflux Disease (인후두역류질환의 실험실 검사의 재평가)

  • Kim, Han-Su
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.18 no.2
    • /
    • pp.102-107
    • /
    • 2007
  • Laryngopharyngeal reflux disease (LPRD) is the result of retrograde flow of gastric contents to the laryngopharynx. Laryngoscopic findings and special questionnaires are first step of diagnosis of LPRD. Empiric trials of Proton pump inhibitor' test (PPI test) is recommended as treatment and diagnosis. However confirmation of reflux is then recommended primarily in patients with persistent symptoms despite acid-suppressive therapy. The 24 hour ambulatory double pH monitoring has been a gold standard method in diagnosis of LPRD even though it has some limitation. The combined multichannel intraluminal impedance and pH monitoring is a new-rising test tool. It can detect acid/non-acid, liquid/gaseous reflux and clearance of refluxate. The water siphon test is also used for diagnosis of LPRD.

  • PDF

Development of Analysis Simulation Tool of High-Energy Ion Implantation Process for GSI MOS Transistor (GSI급 MOS Transistor 개발을 위한 HEI (High-Energy Ion Implantation) 공정 분석 시뮬레이터 개발)

  • 손명식;박수현;이영직;권오근;황호정
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.946-949
    • /
    • 1999
  • In this research we have developed a reliable, effective and feasible HEI(High-Energy Ion Implantation) process 3D-simulation tool, and then by using it we can predict and analyze the effect of HEI process on characteristics of the standard CMOS device. high-energy ion implantation above 200 keV is inevitable process to form retrograde well and buried layer to prevent leakage current, to conduct field implant for field isolation, and to perform after-gate implantation. The feasible analysis tool is a product of the HEI process modeling verified by comparison of the SIMS experiments with the simulation results. Especially, in this paper, we present the predicting capability of HEI-induced impurity and damage profiles compared with the published SIMS data in order to acquire the reliability of our results ranging from few keV to several MeV for phosphorus and boron implantation.

  • PDF

Surgical Treatment of Patent Ductus Aretriosus: Report of 40 cases (개방성 동맥관 수술 보고 (40 예))

  • 노중기
    • Journal of Chest Surgery
    • /
    • v.12 no.2
    • /
    • pp.105-109
    • /
    • 1979
  • Since 1973, 40 patients with Patent Ductus Arteriosus were operated in The Department of Thoracic and Cardiovascular Surgery, Korea University Medical College. Clinical analysis of these cases: 1. Age ranged from 8 months old to 28 years old Sex ratio was 22 females to 18 males. 2. Pulse pressure widening above 50 mmHg was appeared in 27 patients. In 31 patients, continuous machinery murmur was heard on left second and third intercostal space, but 9 patients has holosystolic murmur on left sternal border. 3. Retrograde Aortography was performed in 11 patients and right heart catheterization, 17 patients, In 8 patients, pulmonary hypertension [above 30 mmHg in` systole] was noted. 3 out of 8 patients was combined with Ventricular Septal Defect. Severe pulmonary hypertension [above 80mmHg in systole] was presented in 3 patients. 4. In 38 patients, operative method was performed with multiple suture ligation of PDA, and in 2 patients, suture closure through pulmonary arteriotomy under cardiopulmonary bypass. 5. One operative death occurred in a patient in this group. Cause of death was right heart failure after multiple suture ligation of PDA and pulmonary artery bandings.

  • PDF

TSSG-pulling of sillenite $Bi_{12}TiO_{20}$ for EOS application

  • Miyazawa, Shintaro
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.9 no.4
    • /
    • pp.424-431
    • /
    • 1999
  • The reproducibility of successive growth of $Bi_{12}TiO_{20}$ (BTO) single crystlas using a top-seeded solution growth (TSSG) pulling method was evalutated by measuring the lattice constants and their standard deviations. A substantial phase diagram in the region close to the stoichiometric BTO was established expermentally for this purpose, and the existence of a retrograde solid solution close to a BTO was clarified. It was emphasized that a starting solution, with a 10.0~10.1 mol% $TiO_{2}$ concentration, results in large single crystals with a highly homogeneous lattice constant of within ${\pm}1{\times}10^{-4}\AA$, when the solidified fraction of the grown crystal is less than about 45 %. A wavelength dispersion of refractive index was measrued for the first time, and it was verified that the refractive index of BTO is larger than that of BSO($Bi_{12}TiO_{20}$), allowing the voltage sensitivity of EOS higher than the case with BSO as a probe head.

  • PDF

CASE REPORTS ON TREATMENT OF SKELETAL CLASS III MALOCCLUSION WITH FACE-MASK (Face-Mask를 이용한 골격성 III급 부정교합 환아의 치험례)

  • Yang, Kyu-Ho;Lee, Young-Jun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.3
    • /
    • pp.736-745
    • /
    • 1996
  • The conventional treatment of skeletal Class III malocclusion has been focused on application of orthopedic force primarily to the mandible. However, In Class III malocclusion with retrograde position or underdevelopment of Maxilla, this approach is not suitable treatment. These patients need an application of orthopedic forces via face-mask to the Maxilla to stimulate its growth and to change the direction of growth. In skeletal Class III patients who were treated by Face-Mask, the following results were obtained. 1. Forward growth of Maxilla was enhanced. 2. Labioversion of upper incisors and linguoversion of lower incisors were observed. 3. Mandible was rotated to clockwise direction and remodeling of B point was observed. 4. Anterior crossbite was corrected by combining of the above results.

  • PDF