• 제목/요약/키워드: Retraction force

검색결과 53건 처리시간 0.025초

Torque control during lingual anterior retraction without posterior appliances

  • Mo, Sung-Seo;Kim, Seong-Hun;Sung, Sang-Jin;Chung, Kyu-Rhim;Chun, Yun-Sic;Kook, Yoon-Ah;Nelson, Gerald
    • 대한치과교정학회지
    • /
    • 제43권1호
    • /
    • pp.3-14
    • /
    • 2013
  • Objective: To evaluate the factors that affect torque control during anterior retraction when utilizing the C-retractor with a palatal miniplate as an exclusive source of anchorage without posterior appliances. Methods: The C-retractor was modeled using a 3-dimensional beam element (0.9-mm-diameter stainless-steel wire) attached to mesh bonding pads. Various vertical heights and 2 attachment positions for the lingual anterior retraction hooks (LARHs) were evaluated. A force of 200 g was applied from each side hook of the miniplate to the splinted segment of 6 or 8 anterior teeth. Results: During anterior retraction, an increase in the LARH vertical height increased the amount of lingual root torque and intrusion of the incisors. In particular, with increasing vertical height, the tooth displacement pattern changed from controlled tipping to bodily displacement and then to lingual root displacement. The effects were enhanced when the LARH was located between the central and lateral incisors, as compared to when the LARH was located between the lateral incisors and canines. Conclusions: Three-dimensional lingual anterior retraction of the 6 or 8 anterior teeth can be accomplished using the palatal miniplate as the only anchorage source. Using LARHs at different heights or positions affects the quality of torque and intrusion.

Laser 반사측정법을 이용한 상악전치부의 후방견인시 저항중심의 수직적 위치에 관한 실험적 연구 (EXPERIMENTAL STUDY OF THE VERTICAL LOCATION OF THE CENTERS OF RESISTANCE FOR MAXILLARY ANTERIOR TEETH DURING RETRACTION USING THE LASER REFLECTION TECHNIQUE)

  • 우재영;박영철
    • 대한치과교정학회지
    • /
    • 제23권3호
    • /
    • pp.375-389
    • /
    • 1993
  • The delivery of optimal orthodontic treatment is greatly influenced by a clinician's ability to predict and control tooth movement achieved by applying known force systems to the dentition. It is important to determine the location of the center of resistance of a tooth or group of teeth to better understand the nature of their displacement characteristics under the various force levels. The purpose of this study was to define the location of the centers of resistance of various units of the upper anterior segment for lingually directed 100gm and 200gm force in a dry human skull. The units investigated were composed of four incisors and six anterior teeth. In addition, the effect of change in force magnitude on the location of the center of resistance of these units was investigated. The laser reflection technique was used to measure the initial displacements of the consolidated teeth under loading. The results were as follows: 1. The instantaneous center of resistance for the four anterior teeth was located vertically between level 4 and level 5-that is, at $37.4\%$ apical to the cementoenamel junction level. 2. The instantaneous center of resistance for the six anterior teeth was located vertically just beneath level 5-that is, at $50.3\%$ apical to the cementoenamel junction level. 3. Increasing force levels had little effect on the location of the center of resistance of a given unit. 4. The location of the instantaneous center of resistance shifted apically as the number of dental units consolidated increased.

  • PDF

유한요소법을 이용한 설측 치아교정시 전치부 후방견인에 관한 연구 (Study on the Retraction of Anterior Teeth for the Lingual Orthodontics with the Three-Dimensional Finite Element Method)

  • 송정한;허훈;박현상
    • 대한기계학회논문집A
    • /
    • 제28권8호
    • /
    • pp.1237-1244
    • /
    • 2004
  • The orthodontic surgery including lingual orthodontics has recently attracted a person's attention due to its functional and esthetic appreciation. The skeletal anchorage with the miniscrew is newly adopted in the lingual orthodontics to assist the upholding ability. The appliciation needs to understand the mechanism of the orthodontic appliance and its related orthodontic correction for optimal orthodontic treatment. There is, however, few information about the qualitative and quantitative effect of the orthodontic appliance with the miniscrew has not been well identified. In this paper, three dimensional finite element analysis is introduced to the lingual orthodontics in order to investigate the effect of the anterior retraction force on the miniscrew and transpalatal arch wire. The analysis determines the adequate location of the miniscrew and the point of force application of the anchorage system in the lingual orthodontics. The analysis results demonstrate the effect of the position of the miniscrew and the transpalatal arch wire on the lingual orthodontics.

경사면에서의 리뷸릿 유동에 관한 연구 (A Study of Rivulet Flow on Inclined Surface)

  • 김진호;김호영;이재헌
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.576-581
    • /
    • 2001
  • When a liquid is supplied through a nozzle onto a relatively nonwetting inclined solid surface, a narrow rivulet forms. This work provides novel physical insights into the following phenomena in the rivulet flow that have not been well understood to date. Firstly, the fundamental mechanism behind the transition of a linear rivulet to a droplet flow is investigated. The experiments show that the droplet flow emerges due to the necking of a liquid thread near the nozzle. Based on the observation, it is argued that when the retraction velocity of a liquid thread exceeds its axial velocity, the bifurcation of the liquid thread occurs, and this argument is experimentally verified. Secondly, a discussion on the curved motion of a meandering rivulet is given. This study proposes the contact angle hysteresis as a primary origin of the centripetal force that enables the rivulet's curved motion A simple scaling analysis based on this assumption predicts a radius of curvature which agrees with the experimental observation.

  • PDF

경사면에서의 리뷸릿 유동에 관한 연구 (A Study of Rivulet Flow on an Inclined Solid Surface)

  • 김진호;김호영;강병하;이재헌
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.1042-1048
    • /
    • 2001
  • When a liquid is supplied through a nozzle onto a relatively non-wetting inclined solid surface, a narrow rivulet forms. This work provides novel physical insights into the following phenomena in the rivulet flow that have not been well understood to date. Firstly, the fundamental mechanism behind the transition of a linear rivulet to a droplet flow is investigated. The experiments show that the droplet flow emerges due to the necking of a liquid thread near the nozzle. Based on the observation, it is argued that when the axial velocity of a liquid is slower than the retraction velocity of its thread, the bifurcation of the liquid thread occurs, and this argument is experimentally verified. Secondly, a discussion on the curled motion of a meandering rivulet is given. This study proposes the contact angle hysteresis as a primary origin of the centripetal force that enables the rivulet\`s curved motion. A simple scaling analysis based on this assumption predicts a radius of curvature which agrees with the experimental observation.

  • PDF

Displacement pattern of the anterior segment using antero-posterior lingual retractor combined with a palatal plate

  • Seo, Kyung-Won;Kwon, Soon-Yong;Kim, Kyung A;Park, Ki-Ho;Kim, Seong-Hun;Ahn, Hyo-Won;Nelson, Gerald
    • 대한치과교정학회지
    • /
    • 제45권6호
    • /
    • pp.289-298
    • /
    • 2015
  • Objective: To evaluate and compare the effects of two appliances on the en masse retraction of the anterior teeth anchored by temporary skeletal anchorage devices (TSADs). Methods: The sample comprised 46 nongrowing hyperdivergent adult patients who planned to undergo upper first premolar extraction using lingual retractors. They were divided into three groups, based on the lingual appliance used: the C-lingual retractor (CLR) group (group 1, n = 16) and two antero-posterior lingual retractor (APLR) groups (n = 30, groups 2 and 3). The APLR group was divided by the posterior tube angulation; posterior tube parallel to the occlusal plane (group 2, n = 15) and distally tipped tube (group 3, n = 15). A retrospective clinical investigation of the skeletal, dental, and soft tissue relationships was performed using lateral cephalometric radiographs obtained pretreatment and post en masse retraction of the anterior teeth. Results: All groups achieved significant incisor and canine retraction. The upper posterior teeth did not drift significantly during the retraction period. The APLR group had less angulation change in the anterior dentition, compared to the CLR group. By changing the tube angulation in the APLR, the intrusive force significantly increased in the distally tipped tube of group 3 patients and remarkably reduced the occlusal plane angle. Conclusions: Compared to the CLR, the APLR provides better anterior torque control and canine tipping while achieving bodily translation. Furthermore, changing the tube angulation will affect the amount of incisor intrusion, even in patients with similar palatal vault depth, without the need for additional TSADs.

An objective assessment of the impact of tendon retraction on sleep efficiency in patients with full-thickness rotator cuff tears: a prospective cohort study

  • Ashley E. MacConnell;William Davis;Rebecca Burr;Andrew Schneider;Lara R Dugas;Cara Joyce;Dane H. Salazar;Nickolas G. Garbis
    • Clinics in Shoulder and Elbow
    • /
    • 제26권2호
    • /
    • pp.169-174
    • /
    • 2023
  • Background: Sleep quality, quantity, and efficiency have all been demonstrated to be adversely affected by rotator cuff pathology. Previous measures of assessing the impact of rotator cuff pathology on sleep have been largely subjective in nature. This study was undertaken to objectively analyze this relationship through the use of activity monitors. Methods: Patients with full-thickness rotator cuff tears at a single institution were prospectively enrolled between 2018 and 2020. Waist-worn accelerometers were provided for the patients to use each night for 14 days. Sleep efficiency was calculated using the ratio of the time spent sleeping to the total amount of time that was spent in bed. Retraction of the rotator cuff tear was classified using the Patte staging system. Results: This study included 36 patients: 18 with Patte stage 1 disease, 14 with Patte stage 2 disease, and 4 patients with Patte stage 3 disease. During the study, 25 participants wore the monitor on multiple nights, and ultimately their data was used for the analysis. No difference in the median sleep efficiency was appreciated amongst these groups (P>0.1), with each cohort of patients demonstrating a generally high sleep efficiency. Conclusions: The severity of retraction of the rotator cuff tear did not appear to correlate with changes in sleep efficiency for patients (P>0.1). These findings can better inform providers on how to counsel their patients who present with complaints of poor sleep in the setting of full-thickness rotator cuff tears.

Space closing loop에 의해 야기되는 상악 절치부 이동양상에 관한 역학적 연구 (MECHANICAL ANALYSIS OF THE PATTERN OF MOVEMENT DURING RETRACT10N OF MAXILLARY INCISORS BY SPACE CLOSING LOOP)

  • 민상홍;윤영주;김광원
    • 대한치과교정학회지
    • /
    • 제25권2호
    • /
    • pp.143-152
    • /
    • 1995
  • 이 연구는 다양한 형태의 closing loops의 activation에 따른 치주조직에서의 응력분포를 평가하고 상악 절치의 이동 양상을 예측하기 위하여 3차원 유한요소법에 의하여 시행되었다. 동시에 상악 절치의 견인시 사용되는 bull loop, key-hole loop, T-loop, combination loop 그리고 asymmetrical T-loop도 3차원 유한요소법에 의해 분석 되었다. 이 연구로부터 얻어진 결과는 다음과 같다. 1. 여러가지 형태의 공간폐쇄용 루프중 bull loop에서 가장 큰 수평력을 나타냈으며 , key-hole, combination loop, T-loop 순이었다. 이들 모두 치아이동의 양상은 uncontrolled tipping을 나타냈다. 2. Asymmetrical TMA T-loop에서는 수평력이 현저히 감소하였으며, 절치부위에 함입력이 나타났다. 3. 절치부에서 torque의 증가에 따라 모멘트가 증가하였고, 선형적인 증가를 보였다. 4. 모멘트의 증가에 따라 치아의 초기 이동양상은 uncontrolled tipping에서 치근이동 양상으로 변화되었다.

  • PDF

수문용 대형 유압실린더의 신뢰성평가기준개발

  • 김형의;정동수;이용범;이근호;강보식;윤소남;성백주;김도식;조정대
    • 한국신뢰성학회:학술대회논문집
    • /
    • 한국신뢰성학회 2000년도 추계학술대회
    • /
    • pp.75-86
    • /
    • 2000
  • 본 연구사례는 댐 수문용 대형유압실린더(Piston Diameter :630mm, Stroke:8.3m, weight :30ton, Retraction Force:450ton)의 신뢰성평가를 위한 검토과정에서 제기된 문제를 보완하여, 평가규격을 정립하고, 시험장비를 구축하여, 초대형 유압실린더의 신뢰성 평가를 실시한 사례에 대하여 정리한 것이다.

  • PDF

Effects of bracket slot size during en-masse retraction of the six maxillary anterior teeth using an induction-heating typodont simulation system

  • Kim, Ji-Yong;Yu, Won-Jae;Koteswaracc, Prasad N.K.;Kyung, Hee-Moon
    • 대한치과교정학회지
    • /
    • 제47권3호
    • /
    • pp.158-166
    • /
    • 2017
  • Objective: To investigate how bracket slot size affects the direction of maxillary anterior tooth movement when en-masse retraction is performed in sliding mechanics using an induction-heating typodont simulation system. Methods: An induction-heating typodont simulation system was designed based on the Calorific Machine system. The typodont included metal anterior and resin posterior teeth embedded in a sticky wax arch. Three bracket slot groups (0.018, 0.020, and 0.022 inch [in]) were tested. A retraction force of 250 g was applied in the posterior-superior direction. Results: In the anteroposterior direction, the cusp tip of the canine in the 0.020-in slot group moved more distally than in the 0.018-in slot group. In the vertical direction, all six anterior teeth were intruded in the 0.018-in slot group and extruded in the 0.020- and 0.022-in slot groups. The lateral incisor was significantly extruded in the 0.020- and 0.022-in slot groups. Significant differences in the crown linguoversion were found between the 0.018- and 0.020-in slot groups and 0.018- and 0.022-in slot groups for the central incisor and between the 0.018- and 0.022-in slot groups and 0.020- and 0.022-in slot groups for the canine. In the 0.018-in slot group, all anterior teeth showed crown mesial angulation. Significant differences were found between the 0.018- and 0.022-in slot groups for the lateral incisor and between the 0.018- and 0.020-in slot groups and 0.018- and 0.022-in slot groups for the canine. Conclusions: Use of 0.018-in slot brackets was effective for preventing extrusion and crown linguoversion of anterior teeth in sliding mechanics.