• Title/Summary/Keyword: Retention force

Search Result 169, Processing Time 0.027 seconds

A Study on the Hydrolyzed Ginseng Saponin-Quaternary and its Application in Cosmetics (가수분해된 인삼사포닌 4급 암모늄엽과 화장품으로의 응용에 관한 연구)

  • 김영대;김창규;이정남;하병조
    • Journal of Ginseng Research
    • /
    • v.13 no.2
    • /
    • pp.189-197
    • /
    • 1989
  • A new quaternary ammonium compound, hydrolyzed ginseng-saponin quaternary (HGSQ), from Korean ginseng saponin and 2,3-epoxypropyltrimethylammonium chloride has been developed as a conditioning agent in cosmetics. This structure has a hydrophobic group from the aglycone of ginseng saponin which is biologically active and considered to be the most important component of the Korean ginseng. Its properties : surface tension, critical micelle concentration (CMC), eye irritation, sorption onto hair, force reduction(%) and moisture retention effect were studied. Its cationic character allows the molecule to be more substantive than ginseng saponin. HGSQ had good physical properties and was safe. enough as a cosmetic raw material. Also half-head tests of HGSQ-containing shampoo were carried out to compare the conditioning effects in shampoos. HGSQ was an excellent conditioning agent in shampoo..

  • PDF

Particle Separator using Radiation Force (광력을 이용한 입자 분리 장치)

  • Kim, Sang-Bok;Yoon, Sang-Youl;Kim, Sang-Soo;Sung, Hyung-Jin
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.55-58
    • /
    • 2007
  • To improve the conventional optical chromatography, the continuous particle separator, the cross-type optical chromatography, is fabricated using micro-channel and fiber optics. A laser beam irradiates into the liquid solution containing particles in the perpendicular to the liquid flow direction. The different sized polystyrene latex micro-spheres, $2.0\;{\mu}m\;{\pm}\;0.02\;{\mu}m$, $5.0\;{\mu}m\;{\pm}\;0.05\;{\mu}m$, and $10.0\;{\mu}m\;{\pm}\;0.09\;{\mu}m$ diameter, are separated in cross-type optical chromatography. The separated particles are delivered to down stream in the micro-channel maintaining the retention distance continuously. The measured retention distances for different sized particles well agree with theoretical predictions.

  • PDF

Genotypic and Environmental Effects on Cookie Quality of Korean Winter Wheat

  • Hong, Byung-Hee;Park, Chul-Soo;Baik, Byung-Kee
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.46 no.5
    • /
    • pp.352-359
    • /
    • 2001
  • Cookie baking properties and relationships between cookie baking properties and flour characteristics were evaluated for two years, 1997 and 1998, and at two locations, Suwon and Deokso, with Korean winter wheat cultivars and lines. Cookie baking parameters, except for cookie diameter and top grain score, were influenced by locations and years. Chokwang, Suwon 274, Suwon 275, Suwon 277 and Urimil showed larger cookie diameter and excellent top grain score compared to the other Korean winter wheat cultivars and lines. Among the flour characteristics, protein content, damaged starch content, alkaline water retention capacity and flour swelling volume showed high positive correlation coefficients with cookie baking parameters. Friabilin-present lines showed larger cookie diameter, suitable surface structure of cookie and softer snapping force than the friabilin-absent lines.

  • PDF

A STUDY ON THE PHYSICAL PROPERTIES AND BIOLOGICAL CHARACTERISTICS OF DENTAL MAGNETIC ATTACHMENTS (치과용 자석부착장치의 물리적, 생물학적 특성에 관한 연구)

  • Lim, Yong-Sik;Kim, Yung-Soo;Kim, Chang-Whe;Kim, Yong-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.1
    • /
    • pp.1-22
    • /
    • 1999
  • In order to investigate various physical and biological properties of dental magnetic attachments studies on retentive characteristics, corrosion properties, cytotoxicity of different magnetic systems for dental applications were done. For the study of retentive characteristics changes of retentive force by increasing air gap, wear properties of various attachment systems and loss of magnetic force by heat treatment were measured. Forte study of corrosion property of magnet covering metal electrochemical corrosion was done in artificial saliva and 0.9% NaCl solution between $-1,000mV_{SCE}\;and\;+1,000mV_{SCE}$. Anodic polarization curves are obtained about 6 types of samples and 2 types of solution. Corroded surfaces were examined with metallurgical microscope, scanning electron microscope and surface profilometer. For the study of cytotoxicity of magnetic attachment and its field cell growth and agar overlay test were done. The results of this study were as follows. 1. In Magnetic attachments using closed circuit retentive force at zero air gap was greater than magnets using open circuit, but decrease of retentive force by increasing air gap was also greater than open systems. 2. After 40,000 cycles of wear test all mechanical attachment resulted in varing degree of retention loss but in magnetic attachments no loss of retentive force was observed. 3. The magnetic attachment using Neodymium magnet showed early loss of retentive force about $200^{\circ}C$ but attachment using Samarium magnet showed some resistance to heat treatment and complete retention loss was observed about $500^{\circ}C$. The keeper was not influenced by heat treatment in retention. 4. In electrochemical corrosion test Dyna magnetic attachment covering metal showed the highiest corrosion resistance and Shiner magnet covering metal showed the least corrosion resistance and examination of corroded surface with metallurgical microscope, scanning electron micro-scope and surface profilometer also showed same results with anodic polarization corves. 5. The result of cell culture tests on the magnet covered with metal showed least recognizable cytotoxicity.

  • PDF

Sinking and fit of abutment of locking taper implant system

  • Moon, Seung-Jin;Kim, Hee-Jung;Son, Mee-Kyoung;Chung, Chae-Heon
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.2
    • /
    • pp.97-101
    • /
    • 2009
  • STATEMENT OF PROBLEM. Unlike screw-retention type, fixture-abutment retention in Locking taper connection depends on frictional force so it has possibility of abutment to sink. PURPOSE. In this study, Bicon$^{(R)}$ Implant System, one of the conical internal connection implant system, was used with applying loading force to the abutments connected to the fixture. Then the amount of sinking was measured. MATERIAL AND METHODS. 10 Bicon$^{(R)}$ implant fixtures were used. First, the abutment was connected to the fixture with finger force. Then it was tapped with a mallet for 3 times and loads of 20 kg corresponding to masticatory force using loading application instrument were applied successively. The abutment state, slightly connected to the fixture without pressure was considered as a reference length, and every new abutment length was measured after each load's step was added. The amount of abutment sinking (mm) was gained by subtracting the length of abutment-fixture under each loading condition from reference length. RESULTS. It was evident, that the amount of abutment sinking in Bicon$^{(R)}$ Implant System increased as loads were added. When loads of 20 kg were applied more than 5 - 7 times, sinking stopped at $0.45{\pm}0.09\;mm$. CONCLUSION. Even though locking taper connection type implant shows good adaption to occlusal force, it has potential for abutment sinking as loads are given. When locking taper connection type implant is used, satisfactory loads are recommended for precise abutment location.

Evaluation of the initial retention of implant-retained attachments made of dental polyaryletherketones (PAEKs) (Polyaryletherketones (PAEKs)로 제작된 임플란트 유지형 어태치먼트의 유지력 평가)

  • Soo-chul Park;Sung-Min Kim
    • Journal of Technologic Dentistry
    • /
    • v.45 no.3
    • /
    • pp.61-66
    • /
    • 2023
  • Purpose: The current study examined the retention and wear resistance of stud-type attachments made of high-performance polyetheretherketone (PEEK) or polyetherketoneketone (PEKK) from the polyaryletherketones (PAEKs) family. Methods: The study sample included 10 PEEK or PEKK attachments that were mounted onto their male parts, designed on the upper aspect of the attachment, with a load of 30 N. Tensile stress was applied using an Instron machine to separate the male and female parts, and the maximum tensile stress to be applied was determined based on the retention force observed. The wear resistances of PEEK and PEKK were evaluated by measuring the inner diameter of the inserted female part 10 times. Results: The maximum tensile stresses of PEEK and PEKK were 56.26±0.58 and 69.12±0.92 N, respectively, with the maximum stress required to remove the PEKK specimens from the abutment being 12.86 N higher than that required to remove the PEEK specimens. Furthermore, PEKK exhibited higher wear resistance than PEEK. Conclusion: This study evaluated custom-made removable implant-retained attachment components for overdentures, wherein the female parts were made of PEEK or PEKK. The retention stress and wear resistance were evaluated based on the type of attachment material, and the results showed that both types of attachment inserts demonstrated clinically acceptable results in terms of retention.

INFLUENCE OF TOOTH SURFACE ROUGHNESS AND TYPE OF CEMENT ON RETENTION OF COMPLETE CAST CROWNS (치아표면 거칠기와 시멘트 종류가 전부주조관의 유지력에 미치는 영향)

  • Kim, Kil-Su;Song, Chang-Yong;Ahn, Seung-Geun;Park, Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.465-473
    • /
    • 1999
  • Bond strength of luting cements to dentin is a critical consideration for success of complete cast crowns. This study was performed to evaluate the relationship between surface characteristics of teeth prepared for complete cast crowns and retention of cemented restorations. Eighty artificial crowns were cast for standardized complete crown tooth preparations accomplished with the use of a special device on recently extracted human teeth. Coarse diamond(#102R, Shofu) and superfine finishing diamond(#SF102R, Shofu) burs of similar shape were used. Crowns in each group were randomly subdivided into few subgroups of 10 for luting cements selected for this study: zinc phosphate cement (FLECK' S), polycarboxylate cement (Poly-F), rein-forced glass ionomer cement (Fuji PLUS). and adhesive resin cement (Panavia 21). Retention was evaluated by measuring the tensile load required to dislodge the artificial crown from tooth preparations with an Instron testing machine, and analysed by one-way ANOVA and Student's t-test. The obtained results were as follows ; 1. When tooth preparation was done with coarse diamond bur, retentive force was diminished in order of Panavia 21 Fuji PLUS, FLECK'S, and Poly-F. Retentive forces showed the significant difference between Fuji PLUS group and FLECK'S group(p<0.001). 2. When tooth preparation was done with superfine diamond bur, retentive force was diminished in order of Fuji PLUS, Panavia 21, FLECK'S, and Poly-F. Retentive forces showed the significant difference between Panavia 21 group and FLECK'S group(p<0.001). 3. Retentive force in coarse tooth surfaces was significantly higher than that in superfine tooth surface with all luting cements(p<0.001), and cement residues were almost retained with-in the cast crown in all groups.

  • PDF

Evaluation of citrus fiber as a natural alternative to sodium tripolyphosphate in marinated boneless broiler chicken breast and inside beef skirt (transversus abdominis)

  • Kendal R. Howard;Cheyenne L. Runyan;Allen B. Poe;Andrew M. Cassens;Lea A. Kinman
    • Animal Bioscience
    • /
    • v.37 no.1
    • /
    • pp.116-122
    • /
    • 2024
  • Objective: This research was conducted to evaluate the effects of citrus fiber (CF) as a natural alternative to sodium tripolyphosphate (STPP) in marinated broiler boneless chicken breast and inside beef skirt on overall retention rate, shear force, and consumer sensory attributes. Methods: Five different marinade formulations were targeted to include 0.9% salt, either 0.25% or 0.50% STPP or CF and water on a finished product basis. Water and salt only were considered the negative control (CON). Chicken breasts (n = 14) and inside beef skirt (n = 14) were randomly assigned to a treatment, raw weights recorded and then placed in a vacuum tumbler. Marinated weights were recorded, individually packed, and randomly assigned to either retail display for 10-day retention rate, shear force analysis, cook loss, or consumer sensory panel. Results: Pickup percentage, and overall retention was similar among treatments for chicken breast and inside beef skirt. Citrus fiber treatments resulted in higher cooking loss compared to the CON in chicken breast; though, CF050 resulted in similar cooking loss compared to STPP025 in inside beef skirt. No differences were found in sensory attributes for chicken breast, however, WBSF data showed CF025 was tougher than CF050, STPP050, and CON. Inside beef skirt with CF050 were least liked overall by the consumer panel. Conclusion: Citrus fiber included in marinades at a lower percentage rate can produce similar texture characteristics, and sensory properties compared with those marinated with STPP.

A Literature Review on Locator Attachment for Implant Overdenture (임플란트 피개의치를 위한 Locator 어태치먼트: 문헌 고찰)

  • Cha, Min-Sang;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.127-140
    • /
    • 2013
  • The Locator attachment is used widely for implant retained overdenture. It can be used solitary and needs small vertical space. Locator can be applicable for parallel implants and divergent implants. Nylon male cap allow personalized retention for each case. In this literature review, initial retention force and changes in retention force of various attachments were evaluated. Rotation freedom and stress distribution around the attachment were reviewed. Moreover, patient satisfaction and maintenance care of Locator attachment were described. From all of the researches, it was drawn that Locator attachment can be used successfully and widely in several clinical situations.

Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study

  • Aroso, Carlos;Silva, Antonio Sergio;Ustrell, Raul;Mendes, Jose Manuel;Braga, Ana Cristina;Berastegui, Esther;Escuin, Tomas
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.21-29
    • /
    • 2016
  • This in vitro study investigated and compared the durability and retention of three types of attachments. MATERIALS AND METHODS. Three commercially available attachments were investigated: $Clix^{(R)}$, Dalbo-$Plus^{(R)}$ and $Locator^{(R)}$. In total, 72 samples of these attachments were placed in the acrylic resin forms and subjected to mechanical testing (5400 cycles of insertion and removal) over the respective ball or Locator abutments immersed in artificial saliva at pH 7 and $37^{\circ}C$. The abutments were placed at angulations of $0^{\circ}$, $10^{\circ}$ and $20^{\circ}$. The retention force was recorded at the beginning and after 540, 1080, 2160, 3240, 4320 and 5400 insertion-removal cycles. RESULTS. The results revealed that there were significant differences in the average values of the insertion/removal force due to angulation ($F_{(2.48)}=343619$, P<.05) and the type of attachment ($F_{(7.48)}=23.220$, P<.05). CONCLUSION. Greater angulation of the abutments was found to influence the retention capacity of the attachments, and the fatigue test simulating 5 years of denture insertion and removal did not produce wear in the metal abutments.