• Title/Summary/Keyword: Result Analysis and Evaluation

Search Result 5,763, Processing Time 0.043 seconds

Full mouth rehabilitation for a patient with vertical dimension loss using digital diagnostic analysis: A clinical report (수직고경이 감소된 환자의 디지털 진단 분석을 이용한 완전 구강 회복 증례)

  • Choi, Yeawon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Kim, Hyeong-Seob;Kwon, Kung-Rock;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.487-496
    • /
    • 2021
  • Full mouth rehabilitation is re-organizing the occlusion of the remaining teeth and missing teeth considering the functions, esthetics, and neuromuscular harmony. With the loss of multiple teeth, the patient's occlusal plane gradually collapses and the vertical dimension can be reduced. Since reduced vertical dimension can be a potential etiology of the temporomandibular joint and masticatory muscles, prosthetic restoration with increased vertical dimension is required. This case report is about a 68 years old patient with vertical dimension loss due to worn dentition and multiple loss of teeth. In this case, the loss of vertical dimension is assessed carefully using the digital dentistry technology. Using CAD software in digital analysis step, the occlusal plane was established and evaluated using several criteria. Orienting the position of the bone and teeth using CBCT image, patient's condition was visualized in 3 dimension and treatment planning was possible virtually. The information that matches the patient's condylar position with the articulator, which is the virtual face bow, is reproduced on the actual articulator, and evaluated again. After the evaluation, provisional prosthesis was fabricated and it was confirmed that the patient adapts without any abnormality. This was implemented as a final prosthesis. As a result, the patient obtained satisfying results, utilizing the benefits of digital dentistry technology and traditional methods.

Evaluation of Dark Spots Formated on the High Temperature Metal Filter Elements (고온 금속필터 element 표면에 생성된 반점에 대한 평가)

  • Park, Seung-Chul;Hwang, Tae-Won;Moon, Chan-Kook
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.3
    • /
    • pp.171-178
    • /
    • 2008
  • Metal filter elements were newly introduced to the high temperature filter(HTF) system in the low- and intermediate-level radioactive waste vitrification plant. In order to evaluate the performance of various metal materials as filter media, elements made of AISI 316L, AISI 904L, and Inconel 600 were included to the test set of filter elements. At the visual inspection to the elements performed after completion of each test, a few dark spots were observed on the surface of some elements. Especially they were found much more at the AISI 316L elements than others. To check the dark spots are the corrosion phenomena or not, two kinds of analyses were performed to the tested filter elements. Firstly, the surfaces or the cross sections of filter specimens cut out from both normal area and dark spot area of elements were analyzed by SEM/EDS. The results showed that the dark spots were not evidences of corrosion but the deposition of sodium, sulfur and silica compounds volatilized from waste or molten glass. Secondly, the ring tensile strength were analyzed for the ring-shape filter specimens cut out from each kind of element. The result obtained from the strength tested showed no evidence of corrosion as well. Conclusionally, depending on the two kinds of analysis, no evidences of corrosion were found at the tested metal filter elements. But the dark spots formed on the surface could reduce the effective filtering area and increase the overall pressure drop of HTF system. Thus, continuous heating inside filter housing up to dew point will be required normally. And a few long-period test should be followed for the exact evaluation of corrosion of the metal filter elements.

  • PDF

A Case study and Analysis on the Up-Lift Pressure Treatment Evaluation of Underground Installations for their Efficient Adoption (사례분석을 통한 효율적 상향수압(Up-Lift Pressure) 처리공법 적용방안에 관한연구 - ◯◯ 상업지역 현장사례 중심으로 -)

  • Ko, Ok-Yeol;Kwon, Oh-Chul;Shim, Jae-Kwang;Park, Tae-Eun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.4
    • /
    • pp.119-129
    • /
    • 2009
  • Building construction trends have been changed dramatically in terms of size and mass. With the need to maximize land usage, there has been an increase in the construction of high-rise buildings. This affects not only the entire construction duration and cost, but also subsequent construction activities, such as work to increase underground facilities and in reclamation land area construction. These types of site conditions require soft ground reinforcement and the proper uplift water pressure treatment. In general, two kinds of methods have been used for uplift water pressure treatment systems. However, there have been some problems arising as the result of a lack of research and analysis on underground construction techniques, and a reliance on experiments over actual survey and analysis of site conditions. This paper focused on the problems of conventional selection procedure, by analyzing drawings and proposing a kind of modeling for a reasonable procedure. The results were applied to OO project as a sample construction case to be verified in this research. The initial plan in the case project was the Rock Anchor System. However, as there were terrible miscalculations of basic site conditions that had an extraordinary influence on the underground water level, such as the site's proximity to the Han-river, it was necessary to change the plan to include apermanent drainage system. This achieved a direct construction cost reduction \ 406,702,000 and a maximum sayings of 4% of operational cost, based on the 50-year building Life Cycle Cost.

The Usefulness of Dyspnea Rating in Evaluation for Pulmonary Impairment/Disability in Patients with Chronic Pulmonary Disease (만성폐질환자의 폐기능손상 및 장애 평가에 있어서 호흡곤란정도의 유용성)

  • Park, Jae-Min;Lee, Jun-Gu;Kim, Young-Sam;Chang, Yoon-Soo;Ahn, Kang-Hyun;Cho, Hyun-Myung;Kim, Se-Kyu;Chang, Joon;Kim, Sung-Kyu;Lee, Won-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.2
    • /
    • pp.204-214
    • /
    • 1999
  • Background: Resting pulmonary function tests(PFTs) are routinely used in the evaluation of pulmonary impairment/disability. But the significance of the cardiopulmonary exercise test(CPX) in the evaluation of pulmonary impairment is controvertible. Many experts believe that dyspnea, though a necessary part of the assessment, is not a reliable predictor of impairment. Nevertheless, oxygen requirements of an organism at rest are different from at activity or exercising, and a clear relationship between resting PFTs and exercise tolerance has not been established in patients with chronic pulmonary disease. As well, the relationship between resting PFTs and dyspnea is complex. To investigate the relationship of dyspnea, resting PFTs, and CPX, we evaluated the patients of stabilized chronic pulmonary disease with clinical dyspnea rating(baseline dyspnea index, BDI), resting PFTs, and CPX. Method: The 50 patients were divided into two groups: non-severe and severe group on basis of results of resting PFTs(by criteria of ATS), CPX(by criteria of ATS or Ortega), and dyspnea rating(by focal score of BDI). Groups were compared with respect to pulmonary function, indices of CPX, and dyspnea rating. Results: 1. According to the criteria of pulmonary impairment with resting PFTs, $VO_2$max, and focal score of BDI were significantly low in the severe group(p<0.01). According to the criteria of $VO_2$max(ml/kg/min) and $VO_2$max(%), the parameters of resting PFTs, except $FEV_1$ were not significantly different between non-severe and severe(p>0.05). According to focal score($FEV_1$(%), FVC(%), MW(%), $FEV_1/FVC$, and $VO_2$max were significantly lower in the severe group(p<0.01). However, in the more severe dyspneic group(focal score<5), only $VO_2$max(ml/kg/min) and $VO_2$max(%) were low(p<0.01). $FEV_1$(%) was correlated with $VO_2$max(%)(r=0.52;p<0.01), but not predictive of exercise performance. The focal score had the correlation with max WR(%) (r=0.55;p<0.01). Sensitivity and specificity analysis were utilized to compare the different criteria used to evaluate the severity of pulmonary impairment, revealed that the classification would be different according to the criteria used. And focal score for dyspnea showed similar sensitivity and specificity. Conclusion : According to these result, resting PFTs were not superior to rating of dyspnea in prediction of exercise performance in patients with chronic pulmonary diseases and less correlative with focal score for dyspnea than $VO_2$max and max WR. Therefore, if not contraindicated, CPX would be considered to evaluate the severity of pulmonary impairment in patients with chronic pulmonary diseases, including with severe resting PFTs. Current criteria used to evaluate the severity of impairment were insufficient in considering the degree of dyspnea, so new criteria, including the severity of dyspnea, may be necessary.

  • PDF

Evaluation of Ecological Niche for Major Tree Species in the Natural Deciduous Forest of Mt. Chumbong (점봉산(點鳳山) 일대(一帶) 천연활엽수림(天然闊葉樹林)의 주요(主要) 구성(構成) 수종(樹種)에 대한 생태지위(生態地位) 평가(評價))

  • Kim, Guang Ze;Kim, Ji Hong
    • Journal of Korean Society of Forest Science
    • /
    • v.90 no.3
    • /
    • pp.380-387
    • /
    • 2001
  • The characteristics of ecological niche, breadth and overlap, for seventeen major tree species were evaluated in the natural deciduous forest in Mt. Chumbong area. Employed by the plot sampling method, the environmental gradient for vertical niche was based on the intensity of light within the forest, and that for horizontal niche was based on multi-dimensional resources in distribution pattern. The result showed that Fraxinus rhynchophylla had the highest value of vertical niche breadth and Maackia amurensis had the lowest, and Acer pseudo-sieboldianum had the highest value of horizontal niche breadth and Betula costata had the lowest. There was no significant correlation between both measures of niche breadth. However, the tolerance index for each species was positively correlated to the values of niche breadth. Spearman's rank correlation coefficients were applied to test the correlationship between the species ranks of tolerance index and those of two ecological niche breadths. The coefficient of $r_s=0.432$ ($P{\leq}0.1$) was not enough to support significant correlationship between the tolerance index and vertical niche breadth at the 95% probability. If Carpinus cordata, rarely reach canopy of the forest due to its own growth form, are excluded from the analysis, coefficient was calculated as $r_s=0.650$ ($P{\leq}0.01$), resulting in highly significant correlationship. The Spearman's rank correlation coefficient was $r_s=0.797$ ($P{\leq}0.01$) for tolerance indices and the values of horizontal niche breadth, indicating highly significant. Four distinctive species groups, produced by cluster analysis on the basis of ecological niche overlap for each pair of species, were in considerable accord with the positively associated species constellation pattern created by the inter-species association analysis.

  • PDF

Evaluation of applicability of linkage modeling using PHABSIM and SWAT (PHABSIM과 SWAT을 이용한 연계모델링 적용성 평가)

  • Kim, Yongwon;Byeon, Sangdon;Park, Jinseok;Woo, Soyoung;Kim, Seongjoon
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.10
    • /
    • pp.819-833
    • /
    • 2021
  • This study is to evaluate applicability of linkage modeling using PHABSIM (Physical Habitat Simulation System) and SWAT (Soil and Water Assessment Tool) and to estimate ecological flow for target fishes of Andong downstream (4,565.7 km2). The SWAT was established considering 2 multi purpose dam (ADD, IHD) and 1 streamflow gauging station (GD). The SWAT was calibrated and validated with 9 years (2012 ~ 2020) data of 1 stream (GD) and 2 multi-purpose dam (ADD, IHD). For streamflow and dam inflows (GD, ADD and IHD), R2, NSE and RMSE were 0.52 ~ 0.74, 0.48 ~ 0.71, and 0.92 ~ 2.51 mm/day respectively. As a result of flow duration analysis for 9 years (2012 ~ 2020) using calibrated streamflow, the average Q185 and Q275 were 36.5 m3/sec (-1.4%) and 23.8 m3/sec (0%) respectively compared with the observed flow duration and were applied to flow boundary condition of PHABSIM. The target stream was selected as the 410 m section where GD is located, and stream cross-section and hydraulic factors were constructed based on Nakdong River Basic Plan Report and HEC-RAS. The dominant species of the target stream was Zacco platypus and the sub-dominant species was Puntungia herzi Herzenstein, and the HSI (Habitat Suitability Index) of target species was collected through references research. As the result of PHABSIM water level and velocity simulation, error of Q185 and Q275 were analyzed -0.12 m, +0.00 m and +0.06 m/s, +0.09 m/s respectively. The average WUA (Weighted Usable Area) and ecological flow of Zacco platypus and Puntungia herzi Herzenstein were evaluated 76,817.0 m2/1000m, 20.0 m3/sec and 46,628.6 m2/1000m, 9.0 m3/sec. This results indicated Zacco platypus is more adaptable to target stream than Puntungia herzi Herzenstein.

Evaluation on the Usefulness of Filter in Sentinel Lymphoscintigraphy Using $^{99m}Tc$-Phytate (Phytate를 이용한 감시림프절 검사 시 Filter의 유용성 평가)

  • Jeong, Yeong-Hwan;Seo, Han-Kyung;Shim, Cheol-Min;Lim, Seong-Dong;Han, Dong-Hyeon;Park, Yung-Sun;Kim, Dong-Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.35-39
    • /
    • 2010
  • Purpose: The aim of this study was to investigate distribution of particle size in phytate kit and compare filtered method with non-filtered method using 200 nm filter for sentinel lymphoscintigraphy (SLS). Materials and Methods: Five phytate kit of having the same available period was measured by particle size analyzer. For in-vivo experiment, $^{99m}Tc$-phytate was injected intradermally at both foot to perform lymphoscintigraphy. Imaging was acquired at 1hour after injection. Region of interest (ROI) was drawn in inguinal and background area for analysis. RAW 264.7 cells (Murine macrophage cell) were prepared for measurement of celluar uptake as a representative of macrophages. Paired t-test was performed using SPSS (SPSS Inc, USA) for statistical analysis. Results: The size of most particle in Techne phytate kit was distributed in 130~650 nm(90.5 %). In-vivo study, the ROI analysis showed similar result between filtered and non-filtered sample, and the numerical value of count/pixel were $58.3{\pm}5.97$ and $60.2{\pm}4.88$. In-vitro study, cellular uptake study also showed no difference between filtered and non-filtered sample by gamma counting. Conclusion: The present study demonstrates that there was no meaning of 200 nm filtered method for SLS using $^{99m}Tc$-phytate.

  • PDF

EVALUATION OF CONDYLAR POSITION USING COMPUTED TOMOGRAPH FOLLOWING BILATERAL SAGITTAL SPLIT RAMUS OSTEOTOMY (전산화단층촬영법을 이용한 하악 전돌증 환자의 하악지 시상 골절단술후 하악과두 위치변화 분석)

  • Chol, Kang-Young;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.4
    • /
    • pp.570-593
    • /
    • 1996
  • This study was intended to perform the influence of condyle positional change after surgical correction of skeletal Class III malocclusion after BSSRO in 20 patients(males 9, females 11) using computed tomogram that were taken in centric occlusion before, immediate, and long term after surgery and lateral cephalogram that were taken in centric occlusion before, 7 days within the period intermaxillary fixation, 24hour after removing intermaxillary fixation and long term after surgery. 1. Mean intercondylar distance was $84.45{\pm}4.01mm$ and horizontal long axis of condylar angle was $11.89{\pm}5.19^{\circ}$on right, $11.65{\pm}2.09^{\circ}$on left side and condylar lateral poles were located about 12mm and medial poles about 7mm from reference line(AA') on the axial tomograph. Mean intercondylar distance was $84.43{\pm}3.96mm$ and vertical axis angle of condylar angle was $78.72{\pm}3.43^{\circ}$on right, $78.09{\pm}6.12^{\circ}$on left. 2. No statistical significance was found on the condylar change(T2C-T1C) but it had definitive increasing tendency. There was significant decreasing of the distance between both condylar pole and the AA'(p<0.05) during the long term(TLC-T2C). 3. On the lateral cephalogram, no statistical significance was found between immediate after surgery and 24 hours after the removing of intermaxillary fixation but only the lower incisor tip moved forward about 0.33mm(p<0.05). Considering individual relapse rate, mean relapse rate was 1.2% on L1, 5.0% on B, 2.0% on Pog, 9.1% on Gn, 10.3% on Me(p<0.05). 4. There was statistical significance on the influence of the mandibular set-back to the total mandibular relapse(p<0.05). 5. There was no statistical significance on the influence of the mandibular set-back(T2-T1) to the condylar change(T2C-T1C), the condylar change(T2C-T1C, TLC-T2C) to the mandibular total relapse, the pre-operative condylar position to the condylar change(T2C-T1C, TLC-T2C), the pre-operative mandibular posture to the condylar change(T2C-T1C, TLC-T2C)(p>0.05). 6. The result of multiple regression analysis on the influence of the pre-operative condylar position to the total mandibular relapse revealed that the more increasing of intercondylar distance and condylar vertical axis angle and decreasing of condyalr head long axis angle, the more increasing of mandibular horizontal relapse(L1,B,Pog,Gn,Me) on the right side condyle. The same result was founded in the case of horizontal relapse(L1,Me) on the left side condyle.(p<0.05). 7. The result of multiple regression analysis on the influence of the pre-operative condylar position to the pre-operative mandibular posture revealed that the more increasing of intercondylar distance and condylar vertical axis angle and decreasing of condylar head long axis angle, the more increasing of mandibular vertical length on the right side condyle. and increasing of vertical lengh & prognathism on the left side condyle(p<0.05). 8. The result of simple regression analysis on the influence of the pre-operative mandibular posture to the mandibular total relapse revealed that the more increasing of prognathism, the more increasing of mandibular total relapse in B and the more increasing of over-jet the more increasing of mandibular total relapse(p<0.05). Consequently, surgical mandibular repositioning was not significantly influenced to the change of condylar position with condylar reposition method.

  • PDF

A Study on the Application of Physical Soil Washing Technology at Lead-contaminated Shooting Range in a Closed Military Shooting Range Area (폐 공용화기사격장 내 납오염 사격장 군부지의 물리적 토양세척정화기술 적용성 연구)

  • Jung, Jaeyun;Jang, Yunyoung
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.5
    • /
    • pp.492-506
    • /
    • 2019
  • Heavy metal contaminants in the shooting range are mostly present in a warhead circle or a metal fragment present as a particle, these fine metal particles are weathered for a long period of time is very likely that the surface is present as an oxide or carbon oxide. In particular, lead which is a representative contaminant in the shooting range soil, is present as more fine particles because it increases the softness and is stretched well. Therefore, by physical washing experiment, we conducted a degree analysis, concentration of heavy metals by cubic diameter, composition analysis of metallic substances, and assessment of applicability of gravity, magnetism and floating selection. The experimental results FESEM analysis and the measurement results lead to the micro-balance was confirmed thatthe weight goes outless than the soil ofthe same size in a thinly sliced and side-shaped structure according to the dull characteristics it was confirmed that the high specific gravity applicability. In addition, the remediation efficiency evaluation results using a hydrocyclone applied to this showed a cumulative remediation efficiency of 71%,twice 80%, 3 times 91%. On the other hand, magnetic sifting showed a low efficiency of 17%,floating selection -35mesh (0.5mm)target soil showed a relatively high efficiency to 39% -10mesh (2mm) efficiency was only 16%. The target treatment diameter of soil washing should be 2mm to 0.075mm, which is applied to the actual equipment by adding an additional input classification, which would require management as additional installation costs and processes are constructed. As a result, it is found that the soilremediation of shooting range can be separately according to the size of the warhead. The size is larger than the gravel diameter to most 5.56mm, so it is possible to select a specific gravity using a high gravity. However, the contaminants present in the metal fragments were found to be processed by separating using a hydrocyclone of the soil washing according to the weight is less than the soil of the same particle size in a thinly fragmented structure.

The Accuracy Evaluation according to Dose Delivery Interruption and Restart for Volumetric Modulated Arc Therapy (용적변조회전 방사선치료에서 선량전달의 중단 및 재시작에 따른 정확성 평가)

  • Lee, Dong Hyung;Bae, Sun Myung;Kwak, Jung Won;Kang, Tae Young;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.77-85
    • /
    • 2013
  • Purpose: The accurate movement of gantry rotation, collimator and correct application of dose rate are very important to approach the successful performance of Volumetric Modulated Arc Therapy (VMAT), because it is tightly interlocked with a complex treatment plan. The interruption and restart of dose delivery, however, are able to occur on treatment by various factors of a treatment machine and treatment plan. If unexpected problems of a treat machine or a patient interrupt the VMAT, the movement of treatment machine for delivering the remaining dose will be restarted at the start point. In this investigation, We would like to know the effect of interruptions and restart regarding dose delivery at VMAT. Materials and Methods: Treatment plans of 10 patients who had been treated at our center were used to measure and compare the dose distribution of each VMAT after converting to a form of digital image and communications in Medicine (DICOM) with treatment planning system (Eclipse V 10.0, Varian, USA). We selected the 6 MV photon energy of Trilogy (Varian, USA) and used OmniPro I'mRT system (V 1.7b, IBA dosimetry, Germany) to analyze the data that were acquired through this measurement with two types of interruptions four times for each case. The door interlock and the beam-off were used to stop and then to restart the dose delivery of VMAT. The gamma index in OmniPro I'mRT system and T-test in Microsoft Excel 2007 were used to evaluate the result of this investigation. Results: The deviations of average gamma index in cases with door interlock, beam-off and without interruption on VMAT are 0.141, 0.128 and 0.1. The standard deviations of acquired gamma values are 0.099, 0.091, 0.071 and The maximum gamma value in each case is 0.413, 0.379, 0.286, respectively. This analysis has a 95-percent confidence level and the P-value of T-test is under 0.05. Gamma pass rate (3%, 3 mm) is acceptable in all of measurements. Conclusion: As a result, We could make sure that the interruption of this investgation are not enough to seriously affect dose delivery of VMAT by analyzing the measured data. But this investigation did not reflect all cases about interruptions and errors regarding the movement of a gantry rotation, collimator and patient So, We should continuously maintain a treatment machine and program to deliver the accurate dose when we perform the VMAT for the many kinds of cancer patients.

  • PDF