• Title/Summary/Keyword: Result Analysis and Evaluation

Search Result 5,763, Processing Time 0.044 seconds

Displacement Charateristics of Caisson-Type Breakwater under Earthquake Loadings (지진하중을 받는 케이슨 방파제의 변위 특성분석)

  • Shin, Eun-Chul;Jeon, Jae-Ku;Lee, Joong-Hwa;Lee, Chung-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1258-1270
    • /
    • 2009
  • Recently, the earthquakes activities are more of frequency occurred in the country. In case of nomal or large magnitude earthquakes, which cause a rising number of life loss or widespread loss of property. It must be considered how to cope with the situperty of dpmage in the country ty account of ay earthquake. Consequently, the public works have currently ensured against a lot of risk about seismism not only on large scale structures but also relatively small structures. Therefore, in this study, in order to make the seismic stability safe, it has been evaluated by the seismic performance for caisson-type breakwater. The seismic response analyses have conducted on the caisson-type breaker under long-period, short-period and artificial seismic wave. The liquefaction potential of the foundation, which is caisson-type, is also estimated by using the simplified assessment method. Finally, the result of the numerical analysis by PENTAGON 2D finite element method(FEM) program are presented for 3 cases with time-history seismic analysis under the seismic load.

  • PDF

The Study to Diagnose the Road-Driver Compatibility I: Comparison of Methods for Bio-Signal Analysis (운전자 주행 적합성 진단을 위한 연구 I: 생체신호 분석방법 비교)

  • Kim, Jung-Yong;Yoon, Sang-Young
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.30 no.1
    • /
    • pp.44-49
    • /
    • 2004
  • The aim of this study is to compare the methods in analyzing bio-signals representing measure driver's psychophysiological staus. This study has considered three approaches: first, the deterministic approach calculating the mean and standard deviation of bio-signal, second, probabilistic approach converting driver's bio-signal values to probability density function and identifying individual state relative to overall distribution, and third, diagnostic approach identifying the pattern change of signal over certain period of time. For evaluation of analysis methods, driver's bio-signal was collected under various road conditions, and three analysis approaches were applied respectively. In result, the deterministic approach was found to be simple to use, but generated a large variability of bio-signal. The probabilistic approach provide a relative status of individual driver among overall population, but too much affected by temporal variability of individual driver. The diagnostic approach seemed to reasonably find driver's psychophysiological change over certain period of time, but still needs to develop quantification method of the bio-signal.

Numerical Evaluation on Bending Stiffness of Nodal Connection Systems in the Single Layered Grid Considering Bolt Clearance (볼트 유격을 고려한 단층 그리드 노드 접합 시스템의 휨 강성에 대한 구조 해석적 평가)

  • Hwang, Kyung-Ju
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.4
    • /
    • pp.141-147
    • /
    • 2020
  • Single-layered grid space steel roof structure is an architectural system in which the structural ability of the nodal connection system greatly influences the stability of the entire structure. Many bolt connection systems have been suggested to enhance for better construct ability, but the structural behavior and maximum resistance of the connection system according to the size of bolt clearance play were difficult to identify. In particular, the identification of bending stiffness of the connection system is very important due to the characteristics of shell structures in which membrane stresses based on bending force effect significantly. To identify effective structural behavior and maximum bearing force, four representative nodal connection systems were selected and nonlinear numerical analysis were performed. The numerical analysis considering the size of the bolt clearance were performed to investigate structural behavior and maximum values of the bending force. In addition, the type of effective nodal connection system were evaluated. As a result, the connection system, which has two shear plane, represented high bending stiffness.

Assessment of water quality index suitability of domestic watersheds (국내유역의 수질지수 적합성 평가)

  • Lee, Sangung;Jo, Bugeon;Kim, Young Do
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.5
    • /
    • pp.371-381
    • /
    • 2022
  • Since tributaries have greater water quality variability than main streams, a comprehensive evaluation method that considers the effects of various parameters rather than one water quality parameter has been introduced for effective water quality management of tributaries, but the characteristic of the watershed is not considered. In this study, the urbanization rate, livestock excreta generation, and industrial wastewater discharge in the Hantan River middle-watershed classify urban and non-urban watersheds, and evaluate the suitability of water quality indexes by watershed characteristics by analyzing water quality characteristics and calculating CCME WQI, RTWQI, and NSFWQI. Factor analysis was used to understand the effect of water quality parameters used to calculate the water quality index on the water quality index results. As a result of the factor analysis, the relationship between CCME WQI, TC, and FC was derived, and the relationship between RTWQI and DO, SS in urban watersheds and NSFWQI and FC in non-urban watersheds was revealed. As a result of evaluating suitability through comparison with BOD and T-P grades, it was interpreted that the suitability of the water quality index was low in urban watersheds and that comprehensive water quality evaluation using RTWQI was possible in non-urban watersheds.

Development of a Model for Estimating Leaf Area and the Number of Flower Using Leaf Length and Width of Farfugium japonicum Kitam. (털머위(Farfugium japonicum Kitam.)의 엽장과 엽폭을 이용한 엽면적 및 개화 수 추정 모델 개발)

  • Dae Ho Jung;Yong Suk Chung;Hyunseung Hwang
    • Journal of Bio-Environment Control
    • /
    • v.32 no.2
    • /
    • pp.115-121
    • /
    • 2023
  • The leopard plant has the characteristic of being used for ornamental purposes when there are yellow spots on the leaves, and is widely used as a bed plant for viewing flowers. To set several indicators to predict the growth of crops with ornamental value, and to quantitatively express the relationship between the indicators are necessary. In this study, we determine a model that estimates the leaf area and the number of flower of Farfugium japonicum Kitam. using leaf length and width, and conducting a regression analysis on some regression models. As an indicator for estimating the leaf area and the number of flower, the leaf length and width of F. japonicum were measured and applied to 8 regression models. As a result of regression analysis of 8 models that estimated leaf area and the number of flower, R2 values of the linear models were all higher than 0.84 and 0.80. As a result of validation, using the most reliable model among the models for estimating the leaf area and the number of flowering, R2 was 0.90 and 0.82, respectively. Using a model that estimates various indicators that can be used for quality evaluation from easy-to-measure morphological factors, the evaluation of ornamental plants will be facilitated.

Evaluation of Pullout Capacity of Anchors by Bonded Length through Model Test (모형시험을 통한 정착길이별 앵커의 인발저항력 평가)

  • Han, Jae-Myoung;Kim, Gyu-Hyeong;Woo, Jong-Tae;Lee, Kang-Il
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.3
    • /
    • pp.11-19
    • /
    • 2017
  • A series of pullout tests to compression type anchors is conducted. The test is carried out on a couple of steel cables installed in sandy soil with 60% of relative density. The test is performed with 6 different bonded lengths, which are 1, 2, 3, 4, 5, 6 times longer than the initial bonded length (Lc =30 mm). A numerical analysis with the same condition as the test is also performed to compare each other. Finally, those results are compared with theoretical result by Oosterbaan and Gifford (1972). The result shows that the ultimate pullout capacity appears to increase with an increase of bonded length, and that the results of test, numerical analysis and theoretical approach have a good agreement in the ultimate pullout capacity at failure.

Numerical Analysis for Evaluation of Ejection Capacity Relationship of Safety Valves in Pressure Regulating Station(I) - Flow Analysis and Mass Flow Rate Verification of Pressure Regulator - (정압기지내의 안전밸브 분출용량 관계식 검증을 위한 유동해석(I) - 정압기 유동 해석 및 질량 유량 검증 -)

  • Gwon, Hyuk-Rok;Roh, Kyung-Chul;Kim, Young-Seop;Lee, Seong-Hyuk
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.99-104
    • /
    • 2008
  • Gas pressure regulators in pressure regulating station reduce high-pressure gas in a process line to a lower. Gas pressure regulators are not flow control devices, they are used to control delivery pressure only. For the safety of pressure regulating station, it is essential to study flow regime and characteristics of a safety valves that is connected to a pressure regulator. For this, it is necessary to understand flow characteristics and the flow rate of upstream component part such as gas pressure regulators in regulating station. In the present study, numerical analysis of flow characteristics and the mass flow rate of a pressure regulator is conducted under the several inlet, outlet conditions and open rates. Then, the numerical result of the mass flow rate is verified with experimental equation from manufacture of pressure regulator. Consequently, the numerical result is comparatively good agreement with values from experimental equation.

  • PDF

The Monthly Water Supply Reliability Indexes in the Parallel Reservoir System

  • Park, Ki-Bum;Kim, Sung-Won;Lee, Yeong-Hwa
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1612-1615
    • /
    • 2009
  • Water supply reliability indexes (WSRI) is estimated for assessment of water supply capacity in the downstream for parallel reservoir system in Nakdong River, South Korea, using allocation rule (AR) according to the water supply capacity of each reservoir and the characteristic of parallel reservoir system. The result of the analyzing parallel reservoir system for Andong and Imha reservoir in Nakdong River does not include evidences available enough to decide whether the results of water supply analysis are excellent in the current reliability evaluation or not. However, AR (C) shows a good result in the water supply capacity for each reservoir based on the connected operation system and the total water supply capacity at the control point of downstream by the average water supply capacity and possible range of water supply capacity suggested by this study. The average water supply capacity is analyzed by the reliability of monthly average water supply capacity. Furthermore, the possible range of water supply capacity is estimated by the standard deviation when water deficit occurs. Therefore, AR (C) is useful to establish and estimate the planning water supply capacity according to the monthly water supply condition and the possible range of water supply capacity when the water supply capacity deficit occurs, South Korea.

  • PDF

A Study on the Biodiesel Production Technology using Lard Oil (동물성 유지를 이용한 Biodiesel 생산기술에 관한 연구)

  • Shin, Soo-Beom;Min, Byung-Wook;Yang, Seung-Hun;Park, Min-Seok;Kim, Hae-Sung;Paek, Doo-Hyeon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.19-25
    • /
    • 2006
  • Flesh wasters from tannery create major environmental problems. Despite their considerable fat content, these waster do not find important usage. Their disposal is also troublesome and costly. We have investigated the possible use of this fat as the production of biodiesel(fatty acid methyl esters) by transesterification using with fossil fuels. The fat released the waste by boiling water under the optimal condition (i.e., temperature, $120^{\circ}C;$ decompression, 200mbar) and used to dry without refining for the production of fatty acid methyl esters. Under the optimal condition, the experimental value of biodiesel yield was about 96%. The result of the chemical and GC analysis showed fatty acid composition and characteristics of biodiesel. Evaluation of the product indicated that it was suitable for use as a biodiesel fuel. In result of this experiment oil extract from fleshing process can be transformed into an environmentally affination fuel, to provide economical and ecological profits.

A Study on Evaluation for the Applicatioin of a CFD Code to Flow Analysis and an Estimate of Performance for HAWT (수평축 풍력발전용 터빈의 유동해석 및 성능예측에 대한 CFD의 적용성 평가에 관한 연구)

  • Kim, Beom-Seok;Kim, Jeong-Hwan;Kim, You-Taek;Nam, Chung-Do;Lee, Young-Ho
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2192-2197
    • /
    • 2003
  • The purpose of this 3-D numerical simulation is evaluate the application of a commercial CFD code to predict 3-D flow and power characteristics of wind turbines. The experimental approach, which has been main method of investigation, appears to be its limits, the cost increasing with the size of the wind turbines, hence mostly limited to observing the phenomena on rotor blades. Therefore, the use of Computational Fluid Dynamics (CFD) techniques and Navier-Stokes solvers are considered a very serious contender. The flow solver CFX-TASCflow is employed in all computations in this paper. The 3-D flow separation and the wake distribution of 2 and 3 bladed Horizontal Axis Wind Turbines (HAWTs) are compared to Heuristic model and smoke-visualized experimental result by NREL(National Renewable Energy Laboratory). Simulated 3-D flow separation structure on the rotor blade is very similar to Heuristic model and the wake structure of the wind turbine is good consistent with smoke-visualized result. The calculated power of the 3 bladed rotor by CFD is compared with BEM results by TV-Delft. The CFD results of which is somewhat consist with BEM results, under an error less than 10%.

  • PDF