• 제목/요약/키워드: Restrike voltage

검색결과 4건 처리시간 0.021초

진상소전류시험용 Capacitor Load Bank 설계 (Design of Capacitor Load Bank for Capacitive Current Switching Tests)

  • 노창일;나대열;김선구;정흥수;김원만;이동준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.106-108
    • /
    • 2002
  • Capacitive current switching test for circuit breaker and load breaker switch requires special attention because, after current interruption, the capacitive load contains an electrical charge and can cause dielectric restrike and re-ignition of the switching devices. therefore dielectric strength of capacitor load bank shall be able to withstand 4Vt (Vt : test voltage) and charging voltage discharged within 1 min. In this paper presents both characteristic of capacitive current switching tests and design of capacitor load bank.

  • PDF

민감한 전기전자기기의 전압외란에 대한 영향 최소화 연구 (A Research to Minimizing the Effect of Voltage Disturbances on Sensitive Electrical and Electronic Equipment)

  • 윤갑구
    • 기술사
    • /
    • 제19권2호
    • /
    • pp.10-20
    • /
    • 1986
  • 전압외란(voltage disturbances)에 대하여 민감함 전기전자기기가 받는 영향을 최소화하기 위한 방안으로 전력공급자측에서의 대책과 수용가기기에서의 대응책에 대하여 조사연구하였다. 전력공급자에서의 대책으로는 전압강하 시간의 단축에 대하여 검토하였는데, 효과와 경제성으로 보아 실현가능성이 적었다. 수용가기기에서의 대응책으로는 컴퓨터제어(computer control)와 자동화시스템(automated systems) 등에는 무정전 전원장치 또는 노이즈 서프레서(noise suppressor)나 파워콘디쇼너(power conditioners)를 설치하고, 전자개폐기는 지연석방형 전자개폐기를 채용하며, 가변속제어전동기에는 순간전압부하에 대한 대책이 고려된 제어회로를 채용하고, 고압방전등에는 순간재점등장치가 붙은 등기구를 채용하며, 부족전압계전기는 계전기의 정전시감을 연장하는 방안과 순간정전시에는 자동으로 재투입하는 sequence를 구성하는 방법등이 효과적인 대책으로 검토되었다.

  • PDF

스패터 양을 이용한 아크 안정성 판별에 관한 연구 (A study on determining arc stability using weight of spatter)

  • 강성구;문형순;나석주
    • Journal of Welding and Joining
    • /
    • 제15권6호
    • /
    • pp.41-48
    • /
    • 1997
  • For analyzing the characteristics of arc welding processes, an algorithm is necessary to determine the metal transfer mode, arc stability and weld quality. In this study, the weight of spatter during welding was selected for determining the arc stability, which is very relevant to the occurrence of spatter. Weld spatter occurs mainly at the moment when the short circuit is formed and also when it is broken causing the arc to restrike. Based on this fact, the arc stability can be determined by finding the suitable parameters of welding current and arc voltage which influence the weight of spatter. Through various welding experiments, the peak current, the arcing time, the short circuit time, the current and its slope at the start of short circuit were found mainly to influence the weight of spatter. For the convenient usage, an index was proposed by combining all these parameters. It was found that the index is very effective for determining the arc stability.

  • PDF

평면형 구리 - 탄소 전극의 형태별 재기전압 특성 및 파형 패턴에 관한 연구 (Study on Restriking Transient Voltage Characteristics and Waveform Patterns of Planar Copper-Carbon Electrodes using Forms)

  • 임종민;최충석
    • 한국화재소방학회논문지
    • /
    • 제34권4호
    • /
    • pp.1-6
    • /
    • 2020
  • 본 논문은 직렬 아크 방전이 진행될 때의 전압 및 전류 파형을 실시간 측정하였다. 아크 방전의 방사 패턴을 분석한 결과 간헐적인 방전, 아크의 성장, 발열부의 생성, 플룸의 발생, 적열부 형성 순서로 진행되는 것을 알 수 있었다. 직렬 아크 방진이 진행될 때 전류 및 전압 파형은 정현파와 같은 주기성을 나타냈다. 그리고 + 파형에서 - 파형으로 바뀔 때와 - 파형에서 + 파형으로 바뀔 때 파형의 재기전압이 발생하는 것이 확인되었다. 방전이 진행될 때 1 s 동안에 발생하는 열량은 약 0.317 mJ이고, 600 s 동안에 약 190 mJ의 열이 발생하는 것으로 해석되었다. 그리고 단락 지속시간은 약 1.66 ms인 것으로 해석되었으며, 동일한 주기에서 전압 파형은 49.9 V까지 전위가 상승하는 것을 알 수 있었다. 또한, 방전이 진행될 때 전류의 실효치는 약 1.72 A이고, 최대치는 약 2.53 A로 분석되었다. 그리고 전압의 실효치는 약 42.8 V로 계산되었고, 최대치는 약 208 V로 측정되었다.