• Title/Summary/Keyword: Response to radiation

Search Result 1,274, Processing Time 0.028 seconds

Estimated Risk of Radiation Induced Contra Lateral Breast Cancer Following Chest Wall Irradiation by Conformal Wedge Field and Forward Intensity Modulated Radiotherapy Technique for Post-Mastectomy Breast Cancer Patients

  • Athiyaman, Hemalatha;M, Athiyaman;Chougule, Arun;Kumar, HS
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.12
    • /
    • pp.5107-5111
    • /
    • 2016
  • Background: Epidemiological studies have indicated an increasing incidence of radiation induced secondary cancer (SC) in breast cancer patients after radiotherapy (RT), most commonly in the contra-lateral breast (CLB). The present study was conducted to estimate the SC risk in the CLB following 3D conformal radiotherapy techniques (3DCRT) including wedge field and forward intensity modulated radiotherapy (fIMRT) based on the organ equivalent dose (OED). Material and Methods: RT plans treating the chest wall with conformal wedge field and fIMRT plans were created for 30 breast cancer patients. The risks of radiation induced cancer were estimated for the CLB using dose-response models: a linear model, a linear-plateau model and a bell-shaped model with full dose response accounting for fractionated RT on the basis of OED. Results: The plans were found to be ranked quite differently according to the choice of model; calculations based on a linear dose response model fIMRT predict statistically significant lower risk compared to the enhanced dynamic wedge (EDW) technique (p-0.0089) and a non-significant difference between fIMRT and physical wedge (PW) techniques (p-0.054). The widely used plateau dose response model based estimation showed significantly lower SC risk associated with fIMRT technique compared to both wedge field techniques (fIMRT vs EDW p-0.013, fIMRT vs PW p-0.04). The full dose response model showed a non-significant difference between all three techniques in the view of second CLB cancer. Finally the bell shaped model predicted interestingly that PW is associated with significantly higher risk compared to both fIMRT and EDW techniques (fIMRT vs PW p-0.0003, EDW vs PW p-0.0032). Conclusion: In conclusion, the SC risk estimations of the CLB revealed that there is a clear relation between risk associated with wedge field and fIMRT technique depending on the choice of model selected for risk comparison.

Role of radiotherapy in local control of non-AIDS associated Kaposi's sarcoma patients in Korea: a single institution experience

  • Chang, Ji Hyun;Kim, Il Han
    • Radiation Oncology Journal
    • /
    • v.30 no.4
    • /
    • pp.153-157
    • /
    • 2012
  • Purpose: There has been no definite consensus on standard treatment, either local or systemic, for the Kaposi's sarcoma (KS). Radiotherapy (RT) can be a good local therapeutic choice especially in non-AIDS associated KS (NAKS) for its indolent behavior. Materials and Methods: Medical records of 17 KS patients treated with RT at the Seoul National University Hospital from February 1998 to January 2012 were retrospectively reviewed. One human immunodeficiency virus (HIV)+ patient with 3 lesions was excluded. The total number of the lesion was 23 among the 16 patients. The median follow-up period was 27.9 months. Correlation between response and variables was analyzed using the logistic regression model. Median age of the patients was 75 years. All the 23 lesions were located at the extremities. Fourteen (61%) of those had pain or local swelling as the initial presentation. Ten patients had possible causes of immunodeficiency and were regarded as iatrogenic, and other 6 were classic KS. Median dose of RT was 36 Gy. Results: No KS-related death was observed. Excluding 2 with short-term follow-up only, complete response and partial response were obtained in 2 (9%) and 19 (73%) lesions, respectively. Of those, 3 lesions underwent local progression. Six had out-of-field recurrence after RT. Symptom improvement was achieved in 13 (93%) of 14 patients. Grade 2 skin toxicities were found in 9 lesions but all got improvement after treatment. When divided into responsive and progressive group, free from progression was not related to any of the possible variables. Conclusion: RT is effective in local control of NAKS resulting great response rate.

Adaptive Response to ionizing Radiation Induced by Low Doses of Gamma Rays in Human Lymphoblastoid Cell Lines (인체임파양세포에서 저선량의 감마선에 의해서 유도되는 적응 반응)

  • Seong, Jin-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.12 no.1
    • /
    • pp.1-8
    • /
    • 1994
  • When cells are exposed to low doses of a mutagenic or clastogenic agents. they often become less sensitive to the effects of a higher dose administered subsequently. Such adaptive responses were first described in Escherichia coli and mammalian cells to low doses of an alkylating agent. Since most of the studies have been carried out with human lymphocytes, it is urgently necessary to study this effect in different cellular systems. Its relation with inherent cellular radiosensitivity and underlying mechanism also remain to be answered. In this study, adaptive response by 1 cGy of gamma rays was investigated in three human lymphoblastoid cell lines which were derived from ataxia telangiectasia homozygote, ataxia telangiectasia heterozygote, and normal individual. Experiments were carried out by delivering 1 cGy followed by 50 cGy of gamma radiation and chromatid breaks were scored as an endpoint. The results indicate that prior exposure to 1 cGy of gamma rays reduces the number of chromatid breaks induced by subsequent higher dose (50 cGy), The expression of this adaptive response was similar among three cell lines despite of their different radiosensitivity. When 3-aminobenzamide, an inhibitor of poly (ADP-ribose) polymerase, was added after 50 cGy, adaptive responses were abolished in all the tested cell lines. Therefore it is suggested that the adaptive response can be observed in human lymphoblastoid cell lines, which was first documented through this study. The expression of adaptive response was similar among the cell lines regardless of their radiosensitivity. The elimination of the adaptive response by 3-aminobenzamide is consistent with the proposal that this adaptive response is the result of the induction of a certain chromosomal repair mechanism.

  • PDF

Effects of Inhibitors on Cross-Adaptive Response to Ultraviolet Radiation or Ethyl methanesulfonate in Chinese Hamster Ovary Cells

  • Lee, Dong-Wook;Shin, Eun-Joo;Kim, Seon-Young;Um, Kyung-Il
    • Environmental Mutagens and Carcinogens
    • /
    • v.16 no.2
    • /
    • pp.83-87
    • /
    • 1996
  • This study was performed by the sister chromatid exchanges (SCEs) to investigate the effects of Aphidicolin (APC) or 2, 4-dinitrophenoi (DNP) on cross-adaptive response to ultraviolet radiation (UV) or ethyl methanesulfonate (EMS) in Chinese hamster ovary (CHO) cells. The pretreatment with 1 J/m$^2$ UV decreased the yield of SCEs induced by subsequent treatment with 8 mM EMS in CHO cells. And the treatment with 10 $\mu$g/ml APC or 50 $\mu$M DNP during incubation after pretreatment with 1 J/m$^2$ UV increased the yield of SCEs induced by 8 mM EMS. The pretreatment with 2 mM EMS decreased the yield of SCEs induced by subsequent treatment with 5 J/m$^2$ UV. The treatment with 10 $\mu$g/ml APC during incubation after 2 mM EMS increased the yield of SCEs induced by 5 J/m$^2$ UV. These results suggest that APC and DNP inhibit cross-adaptive response to pretreatment with UV and subsequent treatment with EMS, and also cross-adaptive response to pretreatment with EMS and subsequent treatment with UV is inhibited by APC in CHO cells.

  • PDF

Curative Radiation Therapy for T2N0M0 Non-small Cell Lung Cancer (T2N0M0 비소세포성 폐암의 근치적 방사선치료)

  • Park, In-Kyu;Kim, Jae-Choel
    • Radiation Oncology Journal
    • /
    • v.13 no.1
    • /
    • pp.19-26
    • /
    • 1995
  • Purpose : Surgery is the treatment of choice for resectable non-small cell lung cancer. For patients who are medically unable to tolerate a surgical resection or who refuse surgery, radiation therapy is an acceptable alternative. A retrospective analysis of Patients with stage I non-samll cell lung cancer treated with curative radiation therapy was performed to determine the results of curative radiation therapy and patterns of failure, and to identify factors that may influence survival. Materials and Methods : From 1986 through 1993, 39 Patients with T2N0M0 non-small cell lung cancer were treated with curative radiation therapy at department of radiation oncology, Kyungpook national university hospital. All Patients were not candidates for surgical resection because of either Patient refusal (16 patients), poor pulmonary function (12 patients), old age (7 patients), Poor Performance (2 patients) or coexisting medical disease (2 patients). Median age of patients was 67 years. Histologic cell type was squamous cell carcinoma in 36, adenocarcinoma in 1, large cell carcinoma in 1 and mucoepidermoid carcinoma in 1. All patients were treated with megavoltage irradiation and radiation dose ranged from 5000cgy to 6150cGy with a median dose of 6000cGy. The median follow-up was 17 months with a range of 4 to 82 months, Survival was measured from the date therapy initiated. Results : The overall survival rate for entire Patients was $40.6\%$ at 2 years and $27.7\%$ at 3 years, with a median survival time of 21 months. The disease-free survival at 2 and 3 years was $51.7\%$ and $25.8\%$, respectively. Of evaluable 20 patients with complete response, 15 patients were considered to have failed. Of these, 13 patients showed local failure and 2 patients failed distantly. Response to treatment (p=0.0001), tumor size (p=0.0019) and age (p=0.0247) were favorably associated with overall survival. Only age was predictive for disease-free survival (p = 0.0452). Conclusion : Radiation therapy is an effective treatment for small (less than 3cm) tumors, and should be offered as an alternative to surgery in elderly or infirm patients. Since local failure is the prominent Patterns of relapse, potential methods to improve local control with radiation therapy are discussed.

  • PDF

Effect of Induction Chemotherapy Followed by Radiation Therapy of Locally Advanced Hypopharyngeal Carcinoma (국소진행된 하인두암에서 선행 항암화학요법과 방사선치료의 효과)

  • Kim, Jae-Won;Son, Hee-Young;Jeon, Sea-Yuong;Park, Jung-Je;Ahn, Seong-Ki;Kang, Ki-Mun;Kim, Jin-Pyeong
    • Korean Journal of Head & Neck Oncology
    • /
    • v.24 no.1
    • /
    • pp.26-32
    • /
    • 2008
  • Purpose:Hypopharyngeal carcinoma is usually diagnosed as an advanced disease after an asymptomatic beginning, and it is related to a high frequency of lymph node metastases. An eventual negative outcome may occur not only because of possible locoregional failures but also for frequent distant metastases. Thus, the efficacy of induction chemotherapy followed by radiation therapy, with regards to the response, survival rate and complications for locally advanced hypopharyngeal carcinoma patients, was examined. Methods and Materials:Since July 1998 to February 2001, 18 patients having locally advanced hypopharyngeal carcinoma were treated with induction chemotherapy followed by radiation therapy, and the results were retrospectively analyzed. The regimen of the induction chemotherapy was the 5-flurouracil(5-FU, 1,000mg/$m^2$ daily for 5 consecutive days) and cisplatin(100mg/$m^2$ on day 1) combination at 3-week intervals for 2 cycles. The total radiation dose for the primary tumor and metastatic lymph nodes was 68.4-72.0Gy(median:70.2Gy) Results:The 3-year overall survival rate and disease free survival rate were 31.3% and 22.2%, respectively. In 6 patients(33.3%), preservation of the larynx for over 3 years was possible. After the induction chemotherapy and radiotherapy, a complete response was noted in 14 patients(77.8%), and a partial response in 4 patients (22.2%), with an overall response rate of 100%. Conclusion:Induction chemotherapy followed by radiation therapy is an effective treatment and larynx preservation rate was 33% in patients with locally advanced hypopharyngeal carcinoma in our report.

Development of Diode Based High Energy X-ray Spatial Dose Distribution Measuring Device

  • Lee, Jeonghee;Kim, Ikhyun;Park, Jong-Won;Lim, Yong-Kon;Moon, Myungkook;Lee, Sangheon;Lim, Chang Hwy
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.3
    • /
    • pp.97-106
    • /
    • 2018
  • Background: A cargo container scanner using a high-energy X-ray generates a fan beam X-ray to acquire a transmitted image. Because the generated X-rays by LINAC may affect the image quality and radiation protection of the system, it is necessary to acquire accurate information about the generated X-ray beam distribution. In this paper, a diode-based multi-channel spatial dose measuring device for measuring the X-ray dose distribution developed for measuring the high energy X-ray beam distribution of the container scanner is described. Materials and Methods: The developed high-energy X-ray spatial dose distribution measuring device can measure the spatial distribution of X-rays using 128 diode-based X-ray sensors. And precise measurement of the beam distribution is possible through automatic positioning in the vertical and horizontal directions. The response characteristics of the measurement system were evaluated by comparing the signal gain difference of each pixel, response linearity according to X-ray incident dose change, evaluation of resolution, and measurement of two-dimensional spatial beam distribution. Results and Discussion: As a result, it was found that the difference between the maximum value and the minimum value of the response signal according to the incident position showed a difference of about 10%, and the response signal was linearly increased. And it has been confirmed that high-resolution and two-dimensional measurements are possible. Conclusion: The developed X-ray spatial dose measuring device was evaluated as suitable for dose measurement of high energy X-ray through confirmation of linearity of response signal, spatial uniformity, high resolution measuring ability and ability to measure spatial dose. We will perform precise measurement of the X-ray beamline in the container scanning system using the X-ray spatial dose distribution measuring device developed through this research.

Role of Radiotherapy in Unresectable Pancreatic Carcinoma (수술 불가능한 췌장암 환자에서 방사선 치료의 역할)

  • Shin Hyun Soo;Seong Jinsil;Oh Won Yong;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.119-126
    • /
    • 1993
  • From 1988 to 1991, nineteen patients with unresectable localized pancreatic carcinoma were treated with radiotherapy and/or hyperthermia or in combination with chemotherapy. Radiation dose of 4500-5000 cGy with or without additional 500-1000 cGy was administered over 5 to 6 weeks to the pancreatic tumor area using 10 MV linear accelerator. Five of 19 patients were given chemotherapy, either neoadjuvant or maintenance setting with FAM regimen (5-FU, adriamycin and mitomycin C), which was repeated every 4 weeks for one year or until progression. Symptomatic palliation was achieved in 17 among 19 patients ($89{\%}$) and objective response (complete or partial response in CT finding) was achieved in 5 among 11 patients ($45{\%}$). The median survival time was 9 months and one-year survival rate, $32{\%}$. Local-regional failure was documented in 10 among 13 patients ($77{\%}$) and distant failures were found in the liver (3 patients) and carcinomatosis (2 patients). Prognostic significance of various factors such as age, sex, performance status, tumor location, stage, etc. were assessed. Any factors did not have the prognostic significance in univariate analysis. Treatment was well tolerated in most of the patients with only mild to moderate toxicity.

  • PDF

Treatment outcome in patients with vulvar cancer: comparison of concurrent radiotherapy to postoperative radiotherapy

  • Lee, Ja-Young;Kim, Sung-Hwan;Kim, Gi-Won;Yu, Mi-Na;Park, Dong-Choon;Yoon, Joo-Hee;Yoon, Sei-Chul
    • Radiation Oncology Journal
    • /
    • v.30 no.1
    • /
    • pp.20-26
    • /
    • 2012
  • Purpose: To evaluate outcome and morbidity in patients with vulvar cancer treated with radiotherapy, concurrent chemoradiotherapy or postoperative radiotherapy. Materials and Methods: The records of 24 patients treated with radiotherapy for vulvar cancer between July 1993 and September 2009 were retrospectively reviewed. All patients received once daily 1.8-4 Gy fractions external beam radiotherapy to median 51.2 Gy (range, 19.8 to 81.6 Gy) on pelvis and inguinal nodes. Seven patients were treated with primary concurrent chemoradiotherapy, one patient was treated with primary radiotherapy alone, four patients received palliative radiotherapy, and twelve patients were treated with postoperative radiotherapy. Results: Twenty patients were eligible for response evaluation. Response rate was 55% (11/20). The 5-year disease free survival was 42.2% and 5-year overall survival was 46.2%, respectively. Fifty percent (12/24) experienced with acute skin complications of grade III or more during radiotherapy. Late complications were found in 8 patients. 50% (6/12) of patients treated with lymph node dissection experienced severe late complications. One patient died of sepsis from lymphedema. However, only 16.6% (2/12) of patients treated with primary radiotherapy developed late complications. Conclusion: Outcome of patients with vulvar cancer treated with radiotherapy showed relatively good local control and low recurrence. Severe late toxicities remained higher in patients treated with both node dissection and radiotherapy.

Fabrication and Evaluation of Spectroscopic Grade Quasi-hemispherical CdZnTe Detector

  • Beomjun Park;Kyungeun Jung;Changsoo Kim
    • Journal of Radiation Protection and Research
    • /
    • v.49 no.2
    • /
    • pp.85-90
    • /
    • 2024
  • Background: This study focuses on the fabrication and characterization of quasi-hemispherical Cd0.9Zn0.1Te (CZT) detector for gamma-ray spectroscopy applications, aiming to contribute to advancements in radiation measurement and research. Materials and Methods: A CZT ingot was grown using the vertical Bridgman technique, followed by proper fabrication processes including wafering, polishing, chemical etching, electrode deposition, and passivation. Response properties were evaluated under various external bias voltages using gamma-ray sources such as Co-57, Ba-133, and Cs-137. Results and Discussion: The fabricated quasi-hemispherical CZT detector demonstrated sufficient response properties across a wide range of gamma-ray energies, with sufficient energy resolution and peak distinguishability. Higher external bias voltages led to improved performance in terms of energy resolution and peak shape. However, further improvements in defect properties are necessary to enhance detector performance under low bias conditions. Conclusion: This study underscores the efficacy of quasi-hemispherical CZT detector for gamma-ray spectroscopy, providing valuable insights for enhancing their capabilities in radiation research field.