• 제목/요약/키워드: Respirable Particulate Matter

검색결과 30건 처리시간 0.025초

일부 분진 작업장에서의 폭로분진의 입경분포와 호흡성 분진 비율 (Size Distributions and Respirable Mass Fraction of Exposed Dust in Work Environment)

  • 김영식
    • 한국환경과학회지
    • /
    • 제1권2호
    • /
    • pp.25-31
    • /
    • 1992
  • Authors Investigated the particulate size distribution in work environment of Banwol and Changwon industry complex. Size distributions of particles exposured to workers in welding and in grounding process were evaluated by personal cascade impactors. Personal air samplers with personal cascade impactor were attached to the workers. The mass median diameter measured in welding sites were 0.3 to 3.BUm and in grinding sites were 1.5 to 2.6htn. Respirable matter fractions were ranged 32.67 to 65.055. Respirable matter fractions were calculated from the sixte distribution data by the respirable particle mass of the ACGIH criteria. The study relating to characteristics of particle of other industries and particulate sixte distribution is more needed in the near future

  • PDF

국내 계사(鷄舍) 작업장 유형에 따른 분진 농도 및 발생량 분포 (Distribution of Concentration and Emission of Dust according to Types of Poultry Buildings in Korea)

  • 김기연
    • 한국환경보건학회지
    • /
    • 제43권3호
    • /
    • pp.185-193
    • /
    • 2017
  • Objectives: An on-site study was conducted in order to quantify indoor exposure levels and the emission rate of particulate matter for domestic poultry buildings. Materials and methods: Three types of poultry building (caged layer house, broiler house, and layer house with manure belt) as classified by mode of manure treatment and ventilation were investigated in this study. Nine sites per each poultry building were selected and visited for measuring exposure levels and emission rate of particulate matter. Total dust and respirable dust among the particulate matter were analyzed based on the weight method. Emission rates were estimated by dividing emission amount, which was calculated through multiplying indoor concentration ($mg/m^3$), by the ventilation rate ($m^3/h$), into indoor area ($m^2$) and number of poultry reared in the poultry building. Results: Mean exposure levels for total dust and respirable dust in the poultry buildings were $3.91({\pm}1.99)mg/m^3$ and $1.99({\pm}0.89)mg/m^3$, respectively. The emission rates of particulate matter in the poultry buildings were estimated as $4.75({\pm}1.22)mg\;head^{-1}h^{-1}$ and $64.39({\pm}24.95)g\;m^{-2}h^{-1}$ for total dust and $0.58({\pm}0.23)mg\;head^{-1}h^{-1}$ and $7.52({\pm}2.51)mg\;m^{-2}h^{-1}$ for respirable dust, respectively. The distribution patterns for total dust and respirable dust were similar regardless of poultry building type. Among poultry buildings, broiler house showed the highest exposure level and emission rate of total dust and respirable dust, followed by layer house with manure belt and caged layer house. Conclusions: The finding that the broiler house showed the highest exposure level and emission rate of particulate matter can be attributed to sawdust utilized as bedding material, which can be dispersed into the air by movements of the chickens. Thus, a work environmental management solution for optimally reducing dust concentrations is necessary for broiler houses.

일부 분진 작업장에서의 공기중 분진 입경분포 (A Survey of Particulate Size Distribution in Work Environment)

  • 김영식;이병인;홍성철
    • 한국환경보건학회지
    • /
    • 제17권2호
    • /
    • pp.22-26
    • /
    • 1991
  • Authors investigated the particulate size distribution in work environment of Banwol and Changwon industrial complex. Size distributions of particles exposured to workers in welding and in grinding process were evaluated by ambient cascade impactors. Respirable matter fractions were calculated from the size distribution data by the respirable particle mass of the ACGIH criteria.

  • PDF

성남시 대기정유분새중 호흡성 분여에서 중금속의 농도 및 입경분포 (The Heavy Metals and Size Distribution of Respirable Suspended Particulate Matter at Sungnam City)

  • 권우택;유영식
    • 환경위생공학
    • /
    • 제9권1호
    • /
    • pp.53-61
    • /
    • 1994
  • Sungnam city, as a major satellite town, is located in the southeast of Seoul. Atmospheric conditions are so stable that air pollutants from various emissions are tend to resist change because Sungnam city is located in the Namhansansung valley. The industrial distribution of Sungnam city are composed of various manufactories such as foods, fibers, chemicals, machinery and electronics etc. The heavy metal concentrations and size distribution are the most important parameters influencing among the way in which respirable suspended particulate matter interact with the human respiratory system. Respirable suspended particulate matter was collected on glass fiber filters from April 1993 to February 1994 according to particle size using Anderson sampler during 10 days per month at Sungnam city. 6 heavy metals, Fe, Zn, Pb Mn, Cu and Cd, were analyzed by particle size with atomic absorption spectrophotometry . The results could be summarized as follows: 1. The annual arithmetic mean concentration of total suspended particulate was 116.3$\mu $g/m$^{3}$ m', seasonal variation was the highest in spring season(196.5$\mu $g/m$^{3}$) and the lowest in Summer Season(72.9$\mu $g/m$^{3}$). 2. The ratio of airborne particulate concentrations respirable to nonrepairable( Res/Non- Res) of annual arithmetic mean value was 5.8'1, seasonal variation was highest in the spring season(6.3 : 1) and lowest in the summer season(4.6 : 1). 3. During the spring season the shape of the size distribution was trimodal which showed peaks at 3 size groups, which were below of 0.43$\mu $m, 3.3∼4.7$\mu $m and above of 11.0$\mu $g/m$^{3}$ respectively. 4. Respirable suspended particulate matter concentrations of Zn, Pb Cu and Cd were the highest in below of 0.43$\mu $m as follows; 0.517$\mu $g/m$^{3}$, 0.411 $\mu $g/m$^{3}$, 0.062$\mu $g/m$^{3}$ and 0.0310$\mu $g/m$^{3}$ , respectively, Fe and Mn were the highest in the particle size range of 4.7 ∼ 7.0$\mu $m as follows; 2.504$\mu $g/m$^{3}$ and 0.095$\mu $g/m$^{3}$, respectively. 5. The Pt Cd, Zn, Cu, Fe and Mn concentrations of annual arithmetic mean value respirable to non- respirable( Res/Non- Res ) were 33.65, 19.27, 17.74, 10.54, 3.20 and 5.20, respectively.

  • PDF

기기중성자방사화분석을 이용한 대전 3, 4 공단지역의 호흡성입자의 특성 (Characteristics of Respirable Particulate Matter from the Third and Fourth Industrial Complex Area of Daejeon City Using Instrumental Neutron Activation Analysis)

  • 임종명;이진홍
    • 환경영향평가
    • /
    • 제15권6호
    • /
    • pp.425-433
    • /
    • 2006
  • Instrumental neutron activation analysis was used to measure the concentrations of 27 elements associated with respirable particulate matter (PM10) that were collected from the Third and Fourth Industrial Complex Area of Daejeon City. The distribution patterns of elements were clearly distinguished with their concentrations varying across more than four orders of magnitude. The mean for Al were recorded to be the highest value of 1,527 $ng/m^3$, while that for In showed the lowest value of 0.1 $ng/m^3$. If compared in terms of enrichment factors, it was found that certain elements (e.g., As, Br, Cl, Cr, I, In, Sb, Se, and Zn) are enriched in PM10 samples of the study site. The results of factor analysis indicated six factors with statistical significance, which may exert dominant controls on regulating the elemental concentration levels in the study area.

건설업 옥외작업장 근로자의 미세먼지 노출 실태 조사 (Exposure of Outdoor Workers to Particulate Matter in Construction Sites)

  • 김승원;이가현;피영규;양원호;하권철;박현희
    • 한국산업보건학회지
    • /
    • 제27권1호
    • /
    • pp.46-58
    • /
    • 2017
  • Objectives: Particulate matter (PM) at construction sites mostly originates from either construction activities or the atmospheric environment. This study was conducted to evaluate the exposure level to PM and the contribution ratio of atmosphere sources at construction sites. Methods: We reviewed literature and governmental systems related to PM exposure in occupational settings and summarized them. In the field evaluation, five construction sites and one golf course were selected: two from Gyeonggi-do Province and four from North Gyeongsang-do Province. For each site, personal samples from outdoor construction workers and area samples from the outdoor area around the construction site office were collected according to construction work types. PM concentrations reported from nearby National Ambient Air Monitoring Stations were recorded. Respirable dust concentrations, respirable silica concentrations, and several metal concentrations including Cd, Cr, Pb, and As were monitored over four months. In the end we suggested how to manage particulate matter exposure at construction sites. Results: There was little literature reporting on exposure levels of construction workers to PM. Respirable dust concentrations measured in Gyeonggi-do Province were higher than those measured in North Gyeongsang-do Province. The geometric means of respirable dust concentrations in personal samples and area samples were $37.89{\mu}g/m^3$ and $92.86{\mu}g/m^3$, respectively. The respirable dust concentrations were higher than the PM concentrations reported from nearby National Ambient Air Monitoring Station. The geometric means of respirable silica concentrations of personal samples and area samples were $1.3{\mu}g/m^3$ and $1.1{\mu}g/m^3$, respectively. All metal concentrations were lower than 10% of individual Korean occupational exposure limits. Conclusions: Assuming that personal samples consisted of ambient PM and dust originating from work activities and area samples only collected ambient PM, we concluded that the dust exposure of outdoor construction workers originated 40.8% from the atmosphere and 59.2% from construction activities. PM exposure at construction sites should be controlled by employers, as in the case of outdoor heat stress. The Korean government needs to consider setting an occupational exposure limit for respirable dust.

Evaluation of genotoxic potentials in diesel exhaust particulate matter with the Ames test, the comet assay and the micronucleus assay

  • Kim, Soung-Ho;Lee, Do-Han;Han, Kyu-Tae;Oh, Seung-Min;Chung, Kyu-Hyuck
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.1
    • /
    • pp.165.1-165.1
    • /
    • 2003
  • This research was designed to examine the presence of mutagenic/carcinogenic compounds in airborne pollutants in diesel particulate matter using an integrated biological approach. Respirable air borne particulate matter (PM2.5: <2.5mm) was collected from diesel engine exhaust using a high-volume sampler equipped with a cascade impactor. (omitted)

  • PDF

Evaluation of Endocrine Disrupting Chemicals-Complex Mixture in Diesel Exhaust Respirable Particulate Matter

  • Ryu, Byung-Tak;Jang, Hyoung-Seok;Kim, Yun-Hee;Kim, Soung-Ho;Lee, Do-Han;Han, Kyu-Tae;Oh, Seung-Min;Chung, Kyu-Hyuck
    • 한국환경독성학회:학술대회논문집
    • /
    • 한국환경독성학회 2003년도 춘계학술대회
    • /
    • pp.195-195
    • /
    • 2003
  • It is well known that diesel exhaust particulate matter contains mutagenic PAHs, such as benzo[${\alpha}$]pyrene, benz[${\alpha}$]anthracene, chrysene, etc. Therefore it is suspected that these chemicals act on estrogen receptor and reveal endocrine-disrupting effects. Recent attention has focused on causative chemicals of endocrine-disrupting effects. We examined the estrogenic activity of respirable diesel exhaust particulate matter derived from diesel powered vehicle. PM2.5 diesel exhaust of vehicle was collected using a high volume sampler equipped with a cascade impactor. Diesel exhaust samples were fractionated according to EPA methods. The presence of estrogenic and antiestrogenic chemicals in PM 2.5 diesel exhaust was determined using E-screen assay. To quantitatively assess the estrogenic and antiestrogenic activities in diesel exhaust particulate matter, estradiol equivalent concentration (bio-EEQ) was calculated by comparing the concentration response curve of the sample with those of the estrogen calibration curve. Weak estrogenic activities and strong antiestrogenic activities were detected in the crude extract and moderately polar fractions. Higher antiestrogenic potency was observed with higher EROD activities in aliphatic and aromatic compounds fraction. In conclusion, estrogenic/antiestrogenic-like activities were present in diesel exhaust particulate matter. However, the health consequences of this observation was unknown, the presence of these activities may contribute to and exacerbate adverse health effect evoked by diesel exhaust particulate matter.

  • PDF

의류쇼핑센터 근로자의 분진 및 부유미생물에 대한 노출평가 (Exposure Assessment of Dust and Airborne Microorganisms among Workers in a Clothing Shopping Center)

  • 오성업;김기연
    • 한국산업보건학회지
    • /
    • 제25권2호
    • /
    • pp.194-201
    • /
    • 2015
  • Objectives: The purpose of this study is to assess the exposure level to dust and airborne microorganisms among employed workers in a clothing shopping center. Materials and Methods: On-site investigation of a clothing shopping center was performed between October and November 2012. The hazardous substances measured in this study are particulate matter(Total dust, respirable dust) and airborne microorganisms (Total airborne bacteria, total airborne fungi). Results: The highest geometric mean levels of particulate matter(total dust, respirable dust) for personal sampling were $1.735(SD:0.883)mg/m^3$ for total dust and $0.0711(SD:0.008)mg/m^3$ for respirable dust, respectively. Those for area sampling were $0.625(SD:0.091)mg/m^3$ for total dust and $0.0718(SD:0.012)mg/m^3$ for respirable dust, respectively. The highest geometric averaged concentrations of airborne microorganisms(Total airborne bacteria, total airborne fungi) were detected at $1,181(SD:105)cfu/m^3$ for total airborne bacteria and $683(SD:114)cfu/m^3$ for total airborne fungi, respectively. Concentrations of particulate matters and airborne microorganism in clothes shopping center did not correlate significantly with environmental factors such as temperature or relative humidity. Conclusions: Exposure levelshave not been established for service workers. Thus, health risk assessment for this group is very difficult. Health guidelines for service workers should be established as soon as possible.

Evaluation of Environmental Mutagens-Complex Mixture in Diesel Exhaust Respirable Particulate Matter

  • Kim, Soung-Ho;Ryu, Byung-Tak;Jang, Hyoung-Seok;Kim, Yun-Hee;Lee, Do-Han;Han, Kyu-Tae;Oh, Seung-Min;Chung, Kyu-Hyuck
    • 한국환경독성학회:학술대회논문집
    • /
    • 한국환경독성학회 2003년도 춘계학술대회
    • /
    • pp.194-194
    • /
    • 2003
  • The International Agency for Research on Cancer (IARC, 1989) has classified whole diesel exhaust as probably carcinogenic to humans. Diesel exhaust particulate matter (DPM) adsorbs different chemical substances including PAHs and nitroarenes. DPM is emphasized because it is a major component of diesel exhaust, it is suspected of contributing to a health hazard. Diesel exhaust is a complex mixture of carbon particles and associated organics and inorganics, and it is not known what fraction or combination of fractions cause the health effects [cancer effects, noncancer effects (respiratory tract irritation/inflammation and changes in lung function)] that have been observed with exposure to diesel exhaust. In order to identify which chemical classes are responsible for the majority of the observed biological activities, we performed a particular biological/chemical analysis. Respirable particulate matter (PM2.5: <2.5mm) was collected from diesel engine exhaust using a high-volume sampler equipped with a cascade impactor. Particulate oganic matter was extracted by the dichloromethane/sonication method and the crude extract was fractionated according to EPA recommended procedure into seven fractions by acid-base partitioning and silica gel column chromatography. We examined genotoxic potentials of diesel exhaust particulate matter using novel genotoxicity tests, which are rapid, simple and sensitive methods for assessing DNA-damage at the DNA and chromosomal level (comet assay, in vitro MN test and Ames test). Higher genotoxic potency was observed in non polar fractions and several PAHs were detected by GC-MS, such as 1,2,5,6 dibenzanthracene, chrysene, 1,2-benzanthracene, phenanthrene and fluoranthene.

  • PDF