• Title/Summary/Keyword: Respirable Dust

Search Result 91, Processing Time 0.028 seconds

Proposals for Revising the Occupational Exposure Limits for Aluminum in Korea (국내 알루미늄 노출실태 및 노출기준 개정 제안)

  • Seung Won Kim;Young Gyu Phee;Yong-Joon Baek;Taejin Chung;Hye-Sil Lee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.1
    • /
    • pp.85-97
    • /
    • 2024
  • Objectives: This study was intended to investigate the revision status of the occupational exposure standards for aluminum at home and abroad; to investigate worker exposure at domestic aluminum manufacturing and handling workplaces; to conduct social and economic evaluation for the revision of domestic aluminum exposure limits. Methods: We investigated the current status of occupational exposure limits for aluminum at home and abroad, and analyzed supporting data. An exposure survey was conducted targeting domestic aluminum manufacturing and handling workplaces. Based on these, revised aluminum occupational exposure limits were proposed. Results: The major aluminum exposure limits at home and abroad show a notable difference. The toxicity of aluminum, which was revealed through animal experiments and epidemiological investigations. The average concentration of aluminum in the air at 12 workplaces was 0.016 mg/m3, and the maximum was 0.0776 mg/m3. When total dust and respiratory dust were measured side by side and simultaneously for the same process, 12.1% of the total mass concentration of aluminum dust was respiratory dust. As a result of measuring and comparing the size distribution of dust with an optical particle counter in real time, 48.1% of the total dust in the form of welding fume and pyro-powder was respiratory dust. Based on the literature review and workplace survey, three proposals for changing the aluminum exposure limit were proposed. Proposal (1): For all types, 10 mg/m3 is unified as the exposure limit except for soluble salts and alkyls. Proposal (2): 1(R) mg/m3 as the exposure limit for all forms except soluble salts and alkyl. Proposal (3): 1(R) mg/m3 for pyro-powder and welding fume, and 10 mg/m3 for metal dust, aluminum oxide, and insoluble compounds as exposure standards. A pyro-powder was defined as dry aluminum powder of 200 mesh size (74 ㎛) or smaller (larger size classified as metal dust). Reason for setting: In the workplace survey, the ratio of respiratory dust to total dust was analyzed to be about 1:10, so it was judged that the domestic standard and the ACGIH standard were compatible. Conclusions: In all scenarios according to the revision of the exposure standard, the B/C ratio was greater than 1 or only benefits existed, so it was evaluated as sufficiently reasonable as a result of the socio-economic evaluation.

Evaluation of Crystalline Silica Exposure Level by Industries in Korea (국내 업종별 결정형 유리규산 노출 평가)

  • Yeon, Dong-Eun;Choi, Sangjun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.4
    • /
    • pp.398-422
    • /
    • 2017
  • Objectives: The major aim of this study is to construct the database of retrospective exposure assessment for crystalline silica through reviews of literatures in South Korea. Methods: Airborne concentrations of crystalline silica were collected using an academic information search engine, Research Information Service System(RISS), operated by the Korea Education & Research Information Service(KERIS). The key words used for the literature search were 'silica', 'crystalline silica', 'cristobalite', 'quartz' and 'tridymite'. A total number of 18 published documents with the information of crystalline silica level in air or bulk samples were selected and used to estimate retrospective exposures to crystalline silica. Weighted arithmetic mean(WAM) calculated across studies was summarized by industry type. Industries were classified according to Korea Standard Industrial Classification(KSIC) using information provided in the literature. Results: A total of 2,131 individual air sampling data measured from 1987 to 2012 were compiled. Compiled individual measurement data consisted of 827 respirable crystalline silica (RCS), 31 total crystalline silica(TCS), 24 crystalline silica(CS), 778 respirable dust(RD) and 471 total dust(TD). Most of RCS measurements(68.9%) were collected from 'cast of metals(KSIC 243)'. Comparing industry types, 'mining coal and lignite(KISC 051)' showed the highest WAM concentration of RCS, $0.14mg/m^3$, followed by $0.11mg/m^3$ of 'manufacture of other non-metallic mineral products(KSIC 239)', $0.108mg/m^3$ of 'manufacture of ceramic ware(KSIC 232)', $0.098mg/m^3$ of 'heavy construction(KSIC 412)' and $0.062mg/m^3$ of 'cast of metals(KSIC 243)'. In terms of crystalline silica contents in airborne dust, 'manufacture of other non-metallic mineral products(KSIC 239)' showed the highest value of 7.3%(wt/wt), followed by 6.8% of 'manufacture of ceramic ware(KSIC 232)', 5.8% of 'mining of iron ores(KSIC 061)', 4.9% of 'cast of metals(KSIC 243)' and 4.5% of 'heavy construction(KSIC 412)'. WAM concentrations of RCS had no consistent trends over time from 1994 ($0.26mg/m^3$) to 2012 ($0.12mg/m^3$). Conclusion: The data set related RCS exposure level by industries can be used to determine not only the possibility of retrospective exposure to RCS, but also to evaluate the level of quantitative retrospective exposure to RCS.

A Study on Occupational Environment Assessment Strategies for Respirable Particulate Matter at Coal-Fired Power Plants (석탄화력발전소 호흡성분진 작업환경 평가 전략 사례에 관한 연구)

  • Eun-Seung Lee;Yun-Keun Lee;Dong-Il Shin
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.3
    • /
    • pp.375-383
    • /
    • 2023
  • Objectives: Coal-fired power plants feature diverse working conditions, including multi-layered employment structures and irregular work cycles due to outsourcing and non-standardized tasks. The current uniform occupational environment measurement systems have limitations in accurately assessing and evaluating these varied conditions. This study aims to propose alternative measurement and assessment strategies to supplement existing methods. Methods: Major domestic coal-fired power plants were selected as the study targets. To prepare for the study and establish strategies, work processes were identified and existing occupational environment measurement results were compared and analyzed. The study proceeded by employing three strategies: specific exposure groups (SEGs) measurement, continuous monitoring, and supplementary measurements, which were then compared and discussed. Results: Previous exposure index evaluations (5,268 cases) indicated that crystalline silica, a type of respirable particulate matter, had detection limits below the threshold (non-detectable) in 82.6% (4,349 cases) of instances. Exposures below 10% of the exposure limit were observed at a very low concentration of 96.1%. Similar exposure group measurements yielded results where detection limits were below the threshold in 38.2% of cases, and exposures below 10% of the limit were observed in 70.6%. Continuous monitoring indicated detection limits below the threshold in 12.6% of cases, and exposures below 10% of the limit were observed in 75.6%. Instances requiring active workplace management accounted for more than 30% of cases, with SEGs at 11.8% (four cases), showing a higher proportion compared to 3.0% (four cases) in continuous monitoring. For coal dust, exposures below 10% of the limit were highest in legal measurements at 90.2% (113 cases), followed by 74.0% (91 cases) in continuous monitoring, and 47.0% (16 cases) in SEGs. Instances exceeding 30% were most prevalent in SEGs at 14.7% (five cases), followed by legal measurements at 5.0% (eight cases), and continuous monitoring at 2.4% (three cases). When examining exposure levels through arithmetic means, crystalline silica was found to be 104.7% higher in SEGs at 0.0088 mg/m3 compared to 0.0043 mg/m3 in continuous monitoring. Coal dust measurements were highest in SEGs at 0.1247 mg/m3, followed by 0.1224 mg/m3 in legal measurements, and 0.0935 mg/m3 in continuous monitoring. Conclusions: Strategies involving SEGs measurement and continuous monitoring can enhance measurement reliability in environments with irregular work processes and frequent fluctuations in working conditions, as observed in coal-fired power plants. These strategies reduce the likelihood of omitting or underestimating processes and enhance measurement accuracy. In particular, a significant reduction in detection limits below the threshold for crystalline silica was observed. Supplementary measurements can identify worker exposure characteristics, uncover potential risks in blind spots of management, and provide a complementary method for legal measurements.

A Study on Workers Exposed to Diatomaceous Earth Dust and Development of Pneumoconiosis in a Diatomite Factory (모 규조토 가공 업체의 규조토 분진 폭로에 의한 규조토폐증 유병에 관한 조사)

  • Lim, Hyun-Sul;Kim, Sung-Soon;Lee, Won-Jae
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.1 s.49
    • /
    • pp.1-12
    • /
    • 1995
  • Diatomaceous earth, quarried from the remains of aquatic plants deposited millions of years ago, continues to be a very important raw material with many industrial uses. In its natural state, diatomaceous earth is an amorphous silica with no crystalline pattern. For many uses, however, it is calcinated and calcination converts a portion of the amorphous silica to a crystalline form, cristobalite which is far more fibrogenic. In a factory which produces calcinated diatomaceous earth, seven workers were proved as pneumoconiosis on 1991 and 1992. Authors reviewed medical chart and current status of them. Authors also examined thirty one subjects from the factory with questionnaire, physical examination, spirometry and chest radiography on August 13th 1993. The radiographs were independently interpreted by two radiologists and their findings were classified by International Classification of Radiography of Pneumoconiosis(ILO, 1980). Total and respirable dust of diatomaceous earth were measured on October 1993. The results were as follows; 1. Of 31 workers, 6 (19.4%) were diagnosed as diatomaceous earth pneumoconiosis. There was an increasing tendency in prevalence of pneumoconiosis as the duration of dust exposure gets longer. 2. There were no significant differences in age, smoking rate, alcohol drinking rate, and pulmonary function test results between cases and non-cases. 3. The means of total dust exposures at flour manufacturing, fire brick grinding and packaging, ceramic raws packaging processes exceeded Korean and ACGIH standards, $10mg/m^3$. Above results suggest that engineering controls, periodic environmental and medical surveillance are important for preventing pneumoconiosis in the diatomite factory.

  • PDF

Atmospheric Distribution Characteristics of Airborne Bacteria in Part of Seoul Area (일부 서울 지역 대기 부유세균 분포 현황 조사)

  • Kim, Ki-Youn;Kim, Yoon-Shin;Lee, Cheol-Min;Cho, Man-Su;Byeon, Sang-Hoon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.6
    • /
    • pp.493-502
    • /
    • 2009
  • The concentrations of outdoor airborne bacteria measured in Seoul, Korea for one year (Jan. 2008~Dec. 2008) ranged from $500CFU/m^3$ to $7,500CFU/m^3$. In monthly concentration distribution, the level of outdoor airborne bacteria was highest in September and October and lowest in March. In seasonal concentration distribution, the order of level of outdoor airborne bacteria was autumn>winter>spring>summer. In regional concentration distribution, the highest level of outdoor airborne bacteria was generally found in the forest, followed by general area and traffic site. In distribution characteristics according to particle size, outdoor airborne bacteria showed 31% for >$7.0{\mu}m$ (stage 1), 21% for $4.7{\sim}7.0{\mu}m$(stage 2), 15% for $3.3{\sim}4.7{\mu}m$(stage 3), 19% for $2.1{\sim}3.3{\mu}m$(stage 4), 10% for $1.1{\sim}2.1{\mu}m$(stage 5), and 4% for $0.65{\sim}1.1{\mu}m$(stage 6) and its mean respirable fraction was 48%. In concentration distribution by yellow dust, the mean levels of outdoor airborne bacteria were 803 $(\pm479)CFU/m^3$ for period of yellow dust and 691 $(\pm1,134)CFU/m^3$ for period of non-yellow dust. Although the level of outdoor airborne bacteria was higher in period of yellow dust than period of non-yellow dust, there was no significant difference between period of yellow dust and non-yellow dust (p>0.05). In correlation analysis between outdoor airborne bacteria and atmospheric factors (temperature and relative humidity), there was no significant correlation between outdoor airborne bacteria and atmospheric factors. The predominant airborne bacteria were identified to the Bacillus-derived species.

A Study of $PM_{10}$ and Respirable dust Features in Cast-Iron Factory (주물공장에서 발생되는 $PM_{10}$ 및 호흡성분진의 특성에 관한 연구)

  • 안정언;전기준;박영옥;정용원
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.112-113
    • /
    • 2002
  • 주물작업이란 용융된 금속을 미리 준비한 주형에 부어 원하는 형태의 주물을 만드는 금속성형작업으로서, 생산 공정에서 고열을 이용하여 금속을 용해, 주조하는 등의 작업 특성상 부유분진의 발생이 필연적이며, 일산화탄소, 금속 흄, 휘발성 코울타르 피치, 소음 및 진동, 고열, 전리방사선 등의 유해인자로 인한 피해가 극심하다. 특히 분진은 주물의 생산공정 중 용해, 조형, 탈사 및 후처리 등 거의 전 공정에서 발생되며, 결정형 유리규산(SiO$_2$)을 다량 함유하고 있어 인체에 흡입되었을 때, 건강의 악화 및 직업병의 원인으로서 작업 능률을 떨어뜨리는 요인으로 작용하고 있다(Burgess, 1995). (중략)

  • PDF

Distribution Characteristics of Airborne Fungi in a Partial Area of Seoul City (서울시 일부 지역의 대기 중 부유 진균의 분포 특성)

  • Kim, Ki-Youn;Kim, Dae-Keun
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.5
    • /
    • pp.407-414
    • /
    • 2012
  • Objectives: This study was performed to assess based on field investigation the distribution characteristics of airborne fungi in an area of Seongdong-gu, Seoul. Methods: Three sites, a living area, forest and traffic site, were selected for evaluation of monthly level of outdoor airborne fungi. An on-site survey was executed between January 2009 and December 2009. During the experimental period, air sampling was performed every month in the afternoon (2:00 pm-5:00 pm) using a cascade impactor. Results: Outdoor airborne fungi measured in Seoul, Korea over one year showed a concentration range from 850CFU $m^{-3}$ to 15,200CFU $m^{-3}$. The mean respirable fraction of outdoor airborne fungi was 67% compared to total concentration. Regardless of measurement site, there was no significant concentration difference in outdoor airborne fungi between periods of yellow dust and non-yellow dust (p>0.05). There was no significant correlation relationship between outdoor airborne fungi and atmospheric factors such as temperature and relative humidity. The predominant genera of airborne fungi identified were Aspergillus, Cladosporium, Paecilomyces and Penicillium. Conclusion: Monthly levels of outdoor airborne fungi were highest in April and November and lowest in August. In seasonal concentration distribution, the autumn showed the highest level of outdoor airborne fungi, followed by spring, summer and winter. In regional concentration distribution, the highest level of outdoor airborne fungi was generally found in the forest, followed by the living area and traffic site.

Evaluation of Air Quality in the Compost Pilot Plant with Livestock Manure by Operation Types (축분 퇴비화시스템 운용방식에 따른 실내 대기오염 평가)

  • Kim, K.Y.;Choi, H.L.;Ko, H.J.;Kim, C.N.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.2
    • /
    • pp.283-294
    • /
    • 2004
  • Air quality in the livestock waste compost pilot plant at the Colligate Livestock Station was assessed to quantity the emissions of aerial contaminants and evaluate the degree of correlation between them for different operation strategies; with the ventilation types and agitation of compost pile, in this study. The parameters analyzed to reflect the level of air quality in the livestock waste compost pilot plant were the gaseous contaminants; ammonia, hydrogen sulfide, and odor concentration, the particulate contaminants; inhalable dust and respirable dust, and the biological contaminants; total airborne bacteria and fungi. The mean concentrations of ammonia, hydrogen sulfide, and odor concentration in the compost pilot plant without agitation were 2.45ppm, 19.96ppb, and 15.8 when it was naturally ventilated, and 7.61ppm, 31.36ppb, and 30.2 when mechanically ventilated. Those with agitation were 5.50ppm, 14.69ppb, and 46.4 when naturally ventilated, and 30.12ppm, 39.91ppb, and 205.5 when mechanically ventilated. The mean concentrations of inhalable and respirable dust in the compost pilot plant without agitation were 368.6${\mu}g$/$m^3$ and 96.0${\mu}g$/$m^3$ with natural ventilation, and 283.9${\mu}g$/$m^3$ and 119.5${\mu}g$/$m^3$ with mechanical ventilation. They were also observed with agitation to 208.7${\mu}g$/$m^3$ and 139.8${\mu}g$/$m^3$ with natural ventilation, and 209.2${\mu}g$/$m^3$ and 131.7${\mu}g$/$m^3$ with mechanical ventilation. Averaged concentrations of total airborne bacteria and fungi in the compost pilot plant without agitation were observed to 28,673cfu/$m^3$ and 22,507cfu/$m^3$ with natural ventilation, and 7,462cfu/$m^3$ and 3,228cfu/$m^3$ with mechanical ventilation. They were also observed with agitation to 19,592cfu/$m^3$ and 26,376cfu/$m^3$ with the natural ventilation, and 18,645cfu/$m^3$ and 24,581cfu/$m^3$ with the mechanical ventilation. It showed that the emission rates of gaseous pollutants, such as ammonia, hydrogen sulfide, and odor concentration, in the compost pilot plant operated with the mechanical ventilation and with the agitation of compost pile were higher than those with the natural ventilation and without the agitation. While the concentrations of inhalable dust and total airborne bacteria in the compost pilot plant with the natural ventilation and with the agitation, the concentrations of respirable dust and total airborne fungi in the compost pilot plant with the mechanical ventilation and agitation were higher than those with the natural ventilation and without the agitation of compost pile. It was statistically proved that indoor temperature and relative humidity affected the release of particulates and biological pollutants, and ammonia and hydrogen sulfide were believed primary malodorous compounds emitted from the compost pilot plant.

Relationship between Endotoxin Level of in Swine Farm Dust and Cellular Immunity of Husbandry Workers (돈사 분진 함유 내독소 수준과 축사 작업자들의 세포면역력간 상관성 분석)

  • Kim, Hyoung Ah;Kim, Ji Youn;Shin, Kyeong Min;Jo, Ji Hoon;Roque, Katharine;Jo, Gwang Ho;Heo, Yong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.4
    • /
    • pp.393-401
    • /
    • 2013
  • Objectives: Endotoxins in dust generated in occupational settings is known to contribute to the occurrence of respiratory illness among workers. The relationship between the level of endotoxins in total dust or respirable particulates collected from swine farms and immunological markers related with respiratory allergy was evaluated among swine husbandry workers. Materials and Methods: Peripheral blood samples were collected from ten workers at ten swine farms at Gyeonggi province, Korea. Peripheral mononuclear cells were stimulated with phorbol 12-myristate 13-acetate and ionomycin for 48 hours. The levels of various cytokines produced at culture supernatants were determined using a commercially available ELISA kit. The concentration of particulate matter($PM_{10}$) in the indoor air of the swine farms was evaluated using a PVC membrane filter and mini volume air sampler, and endotoxin levels in the dust were measured by Limulus Amebocyte Lysate Kinetic QCL method. Results: Levels of endotoxins in the total dust were categorized into high(geometric mean: $109.35EU/m^3$) and low concentrations (geometric mean: $0.95EU/m^3$) for five swine farms. Interleukin-4 levels were higher in the high endotoxin group than in the low endotoxin group, while interferon-${\gamma}$ levels were lower in the high endotoxin group than in the low endotoxin group. The ratio (interferon-${\gamma}$ to interleukin-4), indicating immunologic skewedness against allergic reactivities, was lower in the high endotoxin group($1.15{\pm}0.60$) than the low endotoxin group($3.09{\pm}2.38$). In addition, the level of interleukin-13, another cytokine contributing to the occurrence of allergic responses, was significantly higher in the at the high endotoxin group($1.12{\pm}0.37ng/m{\ell}$) than in the low endotoxin group($0.37{\pm}0.04ng/m{\ell}$). Hematologic assessment showed significantly lower cellularity in the number of total leukocytes, neutrophils, and eosinophils in the high endotoxin group than in the low endotoxin group. Conclusions: Even though a sufficient number of swine workers and farms were not investigated, this study generlly suggests that the immunological function of swine farm workers exposed to high levels of endotoxin could be modulated toward allergic reactivities.

Particle Size Distribution of Suspended Particulates in the Atmosphere of a Seoul Residential Area (한 도시 분진의 유해성 입도 분포에 대한 조사 연구)

  • Han, Eui-Jung;Chung, Yong;Kwon, Sook-Pyo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.19 no.1 s.19
    • /
    • pp.130-136
    • /
    • 1986
  • The particle size of suspended particulates was measured by a Anderson air sampler from Mar. 1982 to Feb. 1984 in a part of Seoul. It was concluded as follows : 1) The arithmetic concentration of suspended particulates was $147.8{\mu}g/m^3$ in Spring, 136.9 in Summer, 131.9 in Autumn and 158.1 in Winter respectively. 2) The cumulative distribution of suspended particulates size in logarithmic diagram showed similar to normal log distribution. 3) The atmospheric particulate matters showed a bimodal size distribution on the base of unit particle concentrations, which divided at approximately $2{\mu}m$ in the diameter. 4) While the fine particulates less than $2.1{\mu}m\;was\;35.4{\sim}45.0%$, the coarse particulates was $55.0{\sim}64.5%$. 5) The higher the concentration of suspended particulates, the more increased the ratio of fine particulates. The higher the concentration of suspended particulates, the lower median size of suspended particulate as well. 6) The respirable dust particulates less than $4.7{\mu}m\;was\;52.2{\sim}62.9%$ in seasonal average through the 2 year samples. With the above result, air pollution concerned with public health could be evaluated and the control measures also are suggested.

  • PDF