Design and Characteristics of AE Sensor for Detection of Metallic particle in GIS (GIS 내의 금속이물 탐지용 AE 센서의 설계와 특성)

  • 홍재일;정영호;류주현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.6
    • /
    • pp.502-508
    • /
    • 2000
  • In order to detect the partial discharge with the metallic particle in GIS the AE(Acoustic Emission) sensor was designed and simulated by ANSYS 5.5 and manufactured as the coupled vibration mode. The measured resonant frequency and the maximum sensitivity frequency of three coupled AE sensors were as follows ; 147.88 kHz in 8.1mm $\Phi$$\times$8.1mm 128.82 kHz and 58.8 kHz in 9.5 mm$\Phi$$\times$9.5mm, 85.22 kHz and 32.6 kHz in 14.3 mm$\Phi$$\times$14.3 mm, resonant frequency of the AE sensor. The AE sensor of 9.5 mm$\Phi$$\times$9.5mm responded higher than the other coupled vibration mode AE sensor at the partial discharge detection in GIS.

  • PDF

Mode analysis for the AT Forward MRC (AT 포워드 다중공진형 컨버터의 동작 모드 해석)

  • Kim, Sang-Il;Kim, Hee-Jun;Kim, Chang-Sun;Oh, Won-Seak
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2691-2694
    • /
    • 1999
  • The multi-resonant converter(MRC) can reduce the switching losses exiting in a converter, so it is capable of operating at a high frequency. Such a few MHz high frequency application provides a high power density [$W/inch^{3}$]. But the high voltage stress across a switch of the resonant circuit is about 4$\sim$5 times the input voltage, it causes increasing of the conduction loss in MRC. In this paper, the mode analysis for the suggested AT Forward MRC with low voltage stress is discussed. The operational modes of the AT Forward MRC are divided to 8 equivalent modes according to the two switching sequences, Each mode is analyzed over all of the paper.

  • PDF

Step-Down Voltage Properties of Piezoelectric Transformer with Extensional Vibration Mode (Extensional 진동 모드를 이용한 압전 트랜스포머의 감압 특성)

  • Choi, Ji-Hyun;Bang, Kyu-Seok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.652-655
    • /
    • 2003
  • In this paper, step-down piezoelectric transformer is studied. The piezoelectric transformer, made of lead zirconate titanate solid solution ceramic, is operated by a fundamental contour-extensional vibration mode. The transformer of 14mm length, 14mm width and 4.5mm thickness was made up two shape(Type I and II). The resonant frequency (fr) is 144kHz and 128kHz at the load resistant of $7.5{\Omega}$ that is a similar to calculating matching impedance. The gain (G) obtained 0.19 and 0.08 at each resonant frequency, when applied input voltage is 25V. The temperature difference with the variation of load resistant was increased with increasing load resistant and was the lowest at $7.5{\Omega}$ near the matching of output impedance.

  • PDF

Voltage Gain Characteristics of Piezoelectric Transformer for Power Supply (Power Supply용 압전 트래스포머의 Voltage Gain특성)

  • 김성진;남성이;이수호;홍재일;류주현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.191-194
    • /
    • 1998
  • This Paper present a new structure for a piezoelectric transformer, operating in thickness extensional vibration mode. Modified PbTiO$_3$ family ceramics were used for the Piezoelectric transformer, because it is a material with large anisotropy between electromechanical coupling facters k$\sub$t/ and k$\sub$p/. Piezoelectric transformer was fabricated that is 20mm long, 20mm wide and 3.1mm thick. Resonant frequencies of sencond thickness extensional vibration mode is 1.72MHz at loading resistance 100{$\Omega$]. And Voltage gain of piezoelectric ceramics is showed 0.53 at resonant frequency of sencond thickness extensional vibration mode.

  • PDF

Characteristics of AE Sensor for Detection of Metallic particle in GIS (가스절연개체장치의 금속이물 탐지용 AE 센서의 특성)

  • 홍재일;민석규;정영호;류주현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.286-289
    • /
    • 1999
  • In order to detect the partial discharge with the metallic particle in GIS, AE sensor was designed and simulated by ANSYS, and manufactured as the coupled vibration mode. The resonant frequency of three Coupled AE sensors were as follows ; 147.88 kHz in 8.1 mm$\Phi$ $\times$ 8.1mm, 128.82 kHz in 9.5 mm$\Phi$ $\times$ 9.5mm, 85.22 kHz in 14.3mm$\Phi$ $\times$14.3mm. That frequency is λ/2 resonant frequency. AE sensor of 9.5mm$\Phi$ $\times$9.5mm responded higher than the other coupled vibration mode AE sensor at the partial discharge detection in GIS.

  • PDF

Thickness-Vibration-Mode Piezoelectric Transformer for Power Converter

  • Su-Ho lee;Yoo, Ju-Hyun;Yoon, H.S.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.1 no.3
    • /
    • pp.1-5
    • /
    • 2000
  • This paper presents a new sort of multilayer piezoelectric ceramic transformer for switching regulation power supplies. This piezoelectric transformer operate in the second thickness resonant vibration mode. Accordingly its resonant frequency is higher than 1 NHz, Because output power is low if input and output part of transformer are consisted of single layer, this research suggests a new method, which is consisted of both input and output part of transformer have 2-layered piezoelectric ceramics, The size of transformer is 20 mm in width and length, and 1.4 mm in thickness, respectively, To design a high efficient switching circuit of the transformer, internal circuit parameters were measured and then weve calculated a parameter of inductor nd capacitor to design a driving circuit, Weve used a MISFET and its driver circuit modified a calp oscillator circuit as the primary switching circuit.

  • PDF

Wave Simulation Technique for Large-scale Optical Sensor Designs (거대 스케일 광학 센서 설계를 위한 파동 시뮬레이션(Wave Simulation) 기법 연구)

  • Yong-Hoon Lee;Tae Yoon Kwon;Muhan Choi
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.62-65
    • /
    • 2023
  • The wave mode calculation of a large-scale optical system in comparison to the working wavelength is practically impossible because the computational cost increases exponentially. In this paper, we propose a method that can obtain the optical mode in a large-scale optical system. The method carries out simulations by dividing the calculation area into blocks and moving along the light axis along which the light propagates. By applying this method to the calculation of resonant modes in a ring-type optical resonator, which is mainly used for ring laser optical gyro sensors, the efficiency of the proposed method was verified.

A Contact-less Power Supply using LLC resonant converter for Photovoltaic Power Generation System (태양광 발전 시스템을 위한 LLC 직렬공진컨버터 적용 무접점 전원장치)

  • Lee, H.K.;Lee, G.S.;Kang, S.I.;Kong, Y.S.;Kim, E.S.;Kim, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.347-350
    • /
    • 2006
  • The high efficiency full-bridge LLC resonant converter using a contact-less transformer is proposed for the photovoltaic power generation system. For the series resonance with a series capacitor, the LLC resonant converter utilizes the leakage inductance and magnetizing inductance of a contact-less transformer. Unlike the conventional series resonant converter operated to the continuous resonant current at above resonance frequency, the proposed converter operates to the discontinuous resonant current at the narrow frequency control range below resonance frequency. Due to the discontinuous mode resonant current, the proposed converter can be achieved the zero voltage switching (ZVS) in the primary switches and the zero current switching (ZCS) in the secondary rectification diodes without any auxiliary circuit. In this paper, the experimental results of the proposed full-bridge LLC resonant converter using a contact-less transfonner are verified on the simulation based on the theoretical analysis and the 150W experimental prototype.

  • PDF

The operational characteristics of the AT Forward Multi-Resonant Converter (AT 포워드 다중 공진형 컨버터의 동작 특성)

  • 김창선
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.3
    • /
    • pp.114-123
    • /
    • 1998
  • The multi-resonant converter(MRC) minimizes a parasitic oscillation by using the resonant tank circuit absorbed parasitic reactances existing in a converter circuit. So it si possible that the converter operated at a high frequency has a high efficiency because the losses are reduced. Such a MHz high frequency applications provide a high power density [W/inch3] of the converter. But the resonant voltage stress across a switch of the resonant tank circuit is 4~5 times a input voltage. This h호 voltage stress increases the conduction loss because of on-resistance of a MOSFET with higher rating. Thus, in this paper we proposed the alternated multi-resonant converter (AT MRC) differ from the clamp mode multi-resonant converter and applicated it to the forward MRC. The AT forward MRC can reduce the voltage stress to 2~3 times a input voltage by using two series input capacitor. The control circuit is simple because tow resonant switches are driven directly by the output pulse of the voltage controled oscillator. This circuit type is verified through the experimental converter with 48V input voltage, 5V/50W output voltage/power and PSpice simulation. the measured maximum voltage stress is 170V of 2.9 times the input voltage and the maximum efficiency of 81.66% is measured.

  • PDF

Duplex Pulse Frequency Modulation Mode Controlled Series Resonant High Voltage Converter for X-Ray Power Generator

  • Chu Enhui;Ogura Koki;Moisseev Serguei;Okuno Atsushi;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.295-300
    • /
    • 2001
  • A variety of high voltage DC power supplies employing the high frequency inverter are difficult to achieve soft switching considering a quick response and no overshoot response under the wide load variation ranges which are used in medical-use x-ray high voltage generator from 20kV to 150kV in the output voltage and from 0.5mA to 1250mA, respectively. The authors develops soft switching high voltage DC power supply designed for x-ray power generator applications, which uses series resonant inverter circuit topology with a multistage voltage multiplier instead of a conventional high voltage diode rectifier connected to the second-side of a high-voltage transformer with a large turn ratio. A constant on-time dual mode frequency control scheme operating under a principle of zero-current soft switching commutation is described. Introducing the multistage voltage multiplier, the secondary transformer turn-numbers and stray capacitance of high-voltage transformer is effective to be greatly reduced. It is proved that the proposed high-voltage converter topology with dual mode frequency modulation mode control scheme is able to be the transient response and steady-state performance in high-voltage x-ray tube load. The effectiveness of this high voltage converter is evaluated and discussed on the basis of simulation analysis and observed data in experiment.

  • PDF