• 제목/요약/키워드: Resonant inverter

검색결과 601건 처리시간 0.028초

SRF-PLL을 이용한 계통연계형 단상 인버터의 전원 위상각 검출시 옵셋 오차 영향에 관한 연구 (A Study on Effects of Offset Error during Phase Angle Detection in Grid-tied Single-phase Inverters based on SRF-PLL)

  • 권영;성의석;황선환
    • 조명전기설비학회논문지
    • /
    • 제29권10호
    • /
    • pp.73-82
    • /
    • 2015
  • This paper proposes an ripple reduction algorithm and analyzes the effects of offset and scale errors generated by voltage sensor while measuring grid voltage in grid-tied single-phase inverters. Generally, the grid-connected inverter needs to detect the phase angle information by measuring grid voltage for synchronization, so that the single-phase inverter can be accurately driven based on estimated phase angle information. However, offset and scale errors are inevitably generated owing to the non-linear characteristics of voltage sensor and these errors affect that the phase angle includes 1st harmonic component under using SRF-PLL(Synchronous Reference Frame - Phase Locked Loop) system for detecting grid phase angle. Also, the performance of the overall system is degraded from the distorted phase angle including the specific harmonic component. As a result, in this paper, offset and scale error due to the voltage sensor in single-phase grid connected inverter under SRF-PLL is analyzed in detail and proportional resonant controller is used to reduce the ripples caused by the offset error. Especially, the integrator output of PI(Proportional Integral) controller in SRF-PLL is selected as an input signal of the proportional resonant controller. Simulation and experiment are performed to verify the effectiveness of the proposed algorithm.

Three-Phase AC-to-DC Resonant Converter Operating in High Power Factor Mode in High-Voltage Applications

  • Chaudhari, Madhuri A.;Suryawanshi, Hiralal M.;Kulwal, Abhishek;Mishra, Mahesh K.
    • Journal of Power Electronics
    • /
    • 제8권1호
    • /
    • pp.60-73
    • /
    • 2008
  • In this paper a three-phase ac-to-dc resonant converter with high input power factor and isolated output is proposed. To improve the input power factor of the converter, high frequency current is injected into the input of the three-phase diode bridge rectifier. It is injected through an impedance network consisting of a series of L-C branches from the output of the high frequency three-phase inverter. A narrow switching frequency variation is required to regulate the output voltage. A design example with different design curves is illustrated along with the component ratings. Experimental verification of the converter is performed on a prototype of 3 kW, 1000 V output, operating above 300 kHz. Experimental results confirm the concept of the proposed converter. Narrow switching frequency variation is required to regulate the output voltage.

Grid-tied Power Converter for Battery Energy Storage Composed of 2-stage DC-DC Converter

  • Kim, Do-Hyun;Lee, Yoon-Seok;Han, Byung-Moon;Kim, Ju-Yong;Chae, Woo-Kyu
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1400-1408
    • /
    • 2013
  • This paper proposes a new grid-tied power converter for battery energy storage, which is composed of a 2-stage DC-DC converter and a PWM inverter. The 2-stage DC-DC converter is composed of an LLC resonant converter connected in cascade with a 2-quadrant hybrid-switching chopper. The LLC resonant converter operates in constant duty ratio, while the 2-quadrant hybrid-switching chopper operates in variable duty ratio for voltage regulation. The operation of proposed system was verified through computer simulations. Based on computer simulations, a hardware prototype was built and tested to confirm the technical feasibility of proposed system. The proposed system could have relatively higher efficiency and smaller size than the existing system.

가포화 자기스위치를 이용한 탈황탈질 시스템의 전원장치에 관한 연구 (A study on topology of the DeNOx, DeSOx using magnetic pulse compressors)

  • 김수홍;이용덕;김승모;김병섭;권병기;최창호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.157-159
    • /
    • 2008
  • Generally, Capacitor charging power supply (CCPS) consist of the full-bridge inverter, LC resonant tank and capacitance load. The multi-connection systems are normally used for high voltage or high power application. In this paper, conventional parallel operation resonant type and proposed series operation PWM type CCPS for pulse corona occurrence of DeSOx, DeNOx system using magnetic pulse compressor make a comparison. The effect of proposed CCPS is verified by circuit characteristics analysis of parallel operation resonant type and series operation PWM type, and it is confirmed by simulation result.

  • PDF

LCpCs 공진 탱크를 이용한 방전등용 전자식 안정기의 감도특성 해석 (Sensitivity Analysis of The Electronic Ballasts with The LCpCs-type Resonant Tank for The Discharge Lamps)

  • 박종연;최현희
    • 산업기술연구
    • /
    • 제28권B호
    • /
    • pp.123-127
    • /
    • 2008
  • This paper studied the sensitivity characteries of the electronic ballast for the discharge lamps, which implies variation ratio of the output power by the passive element variation. We have derived the equation to represent the lamp power, and obtained the sensitivity characteristic equations. The simulation result shows that the proposed equations are correct and very useful to design the electronic ballast with the LCpCs-type resonant tank.

  • PDF

부분공진기법을 이용한 연계형 태양광발전시스템 (The Utility Interaction type PV system by using partial resonant system)

  • 고강훈;이현우;김영철;최광주
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.290-295
    • /
    • 1999
  • This paper describes Trans-less type utility interactive system that is combined with buck/boost chopper applying partial resonant method, which remove Trans, and high efficient PWM inverter. Therefore, it is possible to make it lightweight, to cut down the cost, and to improve its reliability. What the merits of this system are that we con transmit arbitrary power to load and utility regardless of generating voltage magnitude and we can always obtain high factor controlling by equal phase signal with utility.

  • PDF

유도 가열기의 제어시스템에 관한 연구 (A Study on Control System Of Induction Heating)

  • 김동운;성낙규;최기수;안규복;이승환;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1254-1256
    • /
    • 2000
  • In this paper, a control scheme for induction heating is proposed. The propose scheme estimates, resonant frequency by PI control subbing a phase of output voltage and resonant capacitor voltage. There are would be two advantages in the proposed system over existing induction heating system. One is the rapid resonant frequency estimation. A other is the just control of temperature. Power Circuit is used a inverter stack and transformer rated on 5.5kw.

  • PDF

단상전원에 적합한 LCC 직병렬 공진 특성 (Resonant Characteristics of LCC Series-Parallel for Single-Phase Power Source)

  • 이달은;윤신용;김일남;김철진;백수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1208-1210
    • /
    • 2004
  • The Cold-Cathode Fluorescent Lamps (CCFL) are widely used to illuminate the liquid crystal displays(LCD) used in many battery powered instrument. This paper presents analysis of fly-back converter for universal-line applications($90\sim265Vac$) and half-bridge type resonant inverter for CCFL drive for stable characteristic and life improvement of fluorescent lamp operation frequency is higher than resonant frequency for safe operation. The validity of this study was confirmed from the simulation and experiential result.

  • PDF

위상제어 LCL형 직렬공진 콘버터의 설계에 관한 연구 (Design considerations for LCL type series resonant converter with phase shift control)

  • 민경진;유상봉;현동석
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.517-525
    • /
    • 1996
  • A Simple AC complex circuit analysis for LCL type series resonant converter with phase shift control is proposed. Based on these analyses, a set of characteristic curves which allows a optimal design procedure for this converter is shown, without increasing the volt-ampere rating of tank circuit Especially, inverter output peak current can be minimized in both full load and partial load conditions. The presented design considerations can make the load range wide from full loads to light loads achieving turn-on with zero voltage switching (ZVS) operation. The detailed analysis and experimental results show the effectiveness of the proposed design algorithms. (author). refs., figs., tab.

  • PDF

독립전압 제어를 위한 다중출력 공진형 컨버터의 적용 (Implementation of a multi-output resonant converter topology for an independent voltage control)

  • 다니엘;박종후
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.265-266
    • /
    • 2015
  • A multiple output dc-dc resonant converter topology for an independent voltage control technique is proposed, using a narrow frequency selection band-pass filters. The multi-output converter is supplied by a single source inverter with the superposed sinusoidal signals reserved for each output. A series-series parallel resonant topology is utilized to implement the narrow frequency selection channels for minimum interference. Finally the experimental setup for four output dc-dc converter is verified with the narrow channel frequencies of 26 kHz, 32 kHz, 38 kHz and 46 kHz.

  • PDF