• 제목/요약/키워드: Resonant Circuits

검색결과 158건 처리시간 0.022초

Modeling of a Transfer Function for Frequency Controlled Resonant Inverters

  • Han, Mu-Ho;Lee, Chi-Hwan;Kwon, Woo-Hyun
    • Journal of Power Electronics
    • /
    • 제9권4호
    • /
    • pp.567-574
    • /
    • 2009
  • A linear transfer function for the output current control of frequency-controlled resonant inverters is proposed in this paper. The circuit of resonant inverters can be transformed into two coupled circuits through the complex phasor transform. The circuits consist of cross-coupled power sources and passive elements. The circuits are used to induce the state space equation, which is transformed into the $4^{th}$ order cross-coupled transfer function. The $4^{th}$ order cross-coupled transfer function is modeled into a $2^{nd}$ order linear transfer function based on a behavior analysis of the pole and zero locations that facilitate a simple and intuitive linear transfer function. The feasibility and validity of the proposed linear transfer function were verified by simulation and experiment.

능동클램프회로를 갖는 병렬공전 인버터 링크형 DC-DC 컨버터 (A Parallel Resonant inverter linked type DC-DC Converter with active-c1amp circuits)

  • 오경섭;남승식;김동희;김희대;선우영호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.311-314
    • /
    • 2003
  • In this paper, proposed circuit proposes that Active-Clamp-Circuits basis of a current-fed inverter linked type high frequency resonant dc-dc converter of conventional. and the paper the most of characteristics of the reduced high voltage stress main switches with active clamp circuits and output current constant with the resonant part consists of L, C resonant tank circuit. Also, the capacitor (C$_1$, C$_2$) connected in switches are a common using by resonance capacitor and ZVS capacitor. and circuit analysis used state equation of each part modes. Also we conform a rightfulness theoretical analysis by comparing a parameters values and simulation values obtained from simulation using Power MOS-FET as switching devices.

  • PDF

부분공진기법에 의한 고효율 인버터 시스템 (High Efficiency Inverter System by Partial Resonant Method)

  • 김영철;이현우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 연구회 합동 학술발표회 논문집
    • /
    • pp.39-43
    • /
    • 1998
  • A large number of soft switching topologies included a resonant circuit have been proposed. But these circuits increase number of switch in circuit and complicate sequence of switching operation. In this paper, the authors propose power conversion system, DC-AC inverter of high efficiency and high power factor with soft switching mode by partial resonant method. The switching devices in a proposed circuits are operated with soft switching by the partial resonant method, that is, PRS2MPC (Partial Resonant Soft Switching Mode Power Converter). The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in partial resonant circuit makes charging energy regenerated at input power source for resonant operation.

  • PDF

두개의 변압기와 공진 탱크로 구성된 LLC 공진 컨버터 (LLC Resonant Converter with Two Transformers and Resonant Tanks)

  • 김주훈;강성인;김은수;전용석;이재삼;허동영
    • 전력전자학회논문지
    • /
    • 제14권5호
    • /
    • pp.406-414
    • /
    • 2009
  • 본 논문에서는 전원장치의 고집적화와 저가격화를 위해 두 개의 공진커패시터와 두 개의 변압기로 구성된 독립된 공진탱크회로를 갖는 LLC 공진 컨버터를 제안하였다. 제안된 공진회로에 적용된 두개의 변압기는 각 변압기에 흐르는 전류 불평형문제를 저감하기 위해 1차 측은 병렬 연결되어 있고 2차 측은 상호 직렬 연결되어 있다. 300W 시제품을 제작 실험한 결과를 통해 제안된 LLC 공진컨버터가 적용 가능함을 나타냈다.

PLL을 이용한 공진부하 MOSFET 인버어터의 주파수 추종제어계 (Frequency Follow-up Control System of Resonant Load MOSFET Inverter using PLL)

  • Kim, Joon-Hong;Joong-Hwan kim
    • 대한전기학회논문지
    • /
    • 제35권7호
    • /
    • pp.272-277
    • /
    • 1986
  • The system that follows to the resonance frequency of high frequency MOSFET inverter and varies according to the changes of load characteristics is proposed. Also we suggested a method how to select the resonant load type between series and parallel circuit for a given inverter type. It leads to the conclusion that in the case of high impedance loads, parallel resonant circuits are preferable, on the other hand, for low impedance loads, series resonant circuits are more preferable. For frequency tracking, a PLL circuit is used as main control element to detect the phase difference of current and voltage of load. The realized apparatus composed of control circuit and voltage type full-bridged MOSFET elements as main parts of inverter. A stable frequency follow-up characteristics are obtained for 1.2MHz, 1.5KW high frequency output and power is always supplied to the load with unity power factor.

  • PDF

Design of a Dual-Band Bandpass Filter Using an Open-Loop Resonator

  • Im, Hyun-Seo;Yun, Sang-Won
    • Journal of electromagnetic engineering and science
    • /
    • 제17권4호
    • /
    • pp.197-201
    • /
    • 2017
  • In this paper, we present a novel design for a dual-band bandpass filter (BPF) based on the conventional second-order, open-loop BPF. By adding series resonant circuits to the open ends of the resonator, we can create two resonant modes from the even and odd modes. One pair of the even and odd modes constitutes the upper passband, while the other pair constitutes the lower passband. By adding another series resonant circuit to the open-loop resonator, we can control the bandwidth of either the upper passband or the lower passband. We can replace the series resonant circuits with simple microstrip line resonators. A dual-band BPF working at both Wi-Fi bands (2.4 GHz and 5.8 GHz bands) is designed based on the proposed method and is tested. The measured and simulated results show excellent agreement.

An Improved Topology for the Current Fed Parallel Resonant Half Bridge Circuits Used in Fluorescent Lamp Electronic Ballasts

  • Wang, Qingsong;Cheng, Ming;Zhang, Bing
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.567-575
    • /
    • 2015
  • An improvement in the current fed parallel resonant half bridge (CFPRHB) circuits used in fluorescent lamp electronic ballasts is provided in this paper. The CFPRHB belongs to the self-oscillating family which includes the current fed push-pull and series resonant inverters, most of which are used in instant-start applications. However, many failure modes are related to the bypass capacitor according to an analysis of failed samples. In this paper, the operating functions of the existing topology in the steady state are analyzed and the main root cause of failure modes has been found. Comparisons between the two topologies are conducted in terms of the voltage stress of the bypass capacitor as well as the thermal and performance of the ballasts to verify the advantages of the proposed topology. It is found that the improved topology is capable of enhancing the reliability and reducing the cost of products without having a negative influence on the system performance.

LC 고주파공진회로를 이용한 사이크로콘버터에 의한 유도전동기의 벡터제어 (Vector Control of IM with The Cycloconverters using High Frequency LC Resonant Circuits)

  • 최정수;조규민;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.680-682
    • /
    • 1993
  • In this paper, rotor flux feedforward control of induction motor fed by cycloconverters with high frequency LC resonant circuits is presented. The cycloconverter using new current control algorithm as a power source of induction motor drive system is proposed. And then its validity of the application to induction motor control system is verified by experimental results.

  • PDF

A Current-Fed Parallel Resonant Push-Pull Inverter with a New Cascaded Coil Flux Control for Induction Heating Applications

  • Namadmalan, Alireza;Moghani, Javad Shokrollahi;Milimonfare, Jafar
    • Journal of Power Electronics
    • /
    • 제11권5호
    • /
    • pp.632-638
    • /
    • 2011
  • This paper presents a cascaded coil flux control based on a Current Source Parallel Resonant Push-Pull Inverter (CSPRPI) for Induction Heating (IH) applications. The most important problems associated with current source parallel resonant inverters are start-up problems and the variable response of IH systems under load variations. This paper proposes a simple cascaded control method to increase an IH system's robustness to load variations. The proposed IH has been analyzed in both the steady state and the transient state. Based on this method, the resonant frequency is tracked using Phase Locked Loop (PLL) circuits using a Multiplier Phase Detector (MPD) to achieve ZVS under the transient condition. A laboratory prototype was built with an operating frequency of 57-59 kHz and a rated power of 300 W. Simulation and experimental results verify the validity of the proposed power control method and the PLL dynamics.

인버터의 손실저감을 위한 소프트 스위칭기법 (A Soft switching method for Loss reduction of Inverter)

  • 곽동걸;김영철;이현우
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(5)
    • /
    • pp.249-252
    • /
    • 2001
  • A large number of soft switching topologies included a resonant circuit have been proposed. But these circuits increase number of switch in circuit and complicate sequence of switching operation. In this Paper, the authors propose power conversion system, DC-AC inverter of high efficiency and high power factor with soft switching mode by partial resonant method. The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in partial resonant circuit makes charging energy regenerated at input power source for resonant operation.

  • PDF