• 제목/요약/키워드: Resonance situation

검색결과 44건 처리시간 0.027초

A Comparison of Surge Behaviors in Multi-Stage and Single-Stage Axial Flow Compressors

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권4호
    • /
    • pp.338-353
    • /
    • 2016
  • Information on the surge behaviors and stall stagnation boundaries for a nine-stage axial flow compressor are summarized on the basis of analytical data in comparison with those for a single-stage one, with attention to the pressure ratio effect. The general trends of the surge loop behaviors of the pressure-mass flow are similar for both compressors including the fact that the subharmonic surges tend to appear very near the stall stagnation boundaries. With respect to the nine-stage compressor, however, the mild loops in the subharmonic surges tend to be very small in size relative to the deep loops, and at the same time, insufficient surge recovery phenomenon, which is a kind of subharmonic surge, appears also far from the stagnation boundary for relatively short delivery flow-paths. The latter is found to be a rear-stage surge caused by unstalling and re-stalling of the rear stages with the front-stages kept in stall in the stalled condition of the whole compressor, which situation is caused by stage-wise mismatching in the bottom pressure levels of the in-stall multi-stage compressor. The fundamental information on the stall stagnation boundaries is given by a group of normalized geometrical parameters including relative delivery flow-path length, relative suction flow-path length, and sectional area-pressure ratio, and by another group of normalized frequency parameters including relative surge frequencies, modified reduced resonance frequencies, and modified reduced surge frequencies. Respective groups of the normalized parameters show very similar tendency of behaviors for the nine-stage compressor and the single-stage compressor. The modified reduced resonance frequency could be the more reasonable parameter suggesting the flow-induced oscillation nature of the surge phenomena. It could give the stall stagnation boundary in a more unified manner than the Greitzer's B parameter.

250W MHL용 Buck Type 전자식 안정기 및 Dimming 시스템 개발 (The Development of Buck Type Electronic Ballast for 250W MHL and Dimming System)

  • 박종연;박영길;정동열;김한수
    • 전력전자학회논문지
    • /
    • 제7권1호
    • /
    • pp.30-40
    • /
    • 2002
  • 본 논문은 250w 메탈 할라이드 램프용 전자식 안정기의 개발에 관한 연구로써 안정기의 입력 역율은 PFC IC를 이용하여 개선하였고, 벅 Type의 DC-DC 컨버터를 회로에 삽입하여 인버터회로에서 램프의 정격전압만을 공급할 수 있도록 함으로써 인버터 스위칭소자의 스트레스를 줄이게 되었다. 인버터의 형태는 풀 브릿지로 하였고 램프 점등을 구형 저주파에 고주파 성분을 첨가하는 방식으로 음향공명현상을 제거하였다. 또한 LC 회로를 이용한 간단 한 점화기 회로를 개발하였다. 벅 컨버터의 출력 전압을 조절하여 램프의 전압이 가변되는 원리를 이용하여 조광 제어를 할 수 있으며 계절별 및 시간대별로 점등시간과 조도조절이 가능토록 하였다. 벅 컨버터 출력 전압의 조절과 무부하 보호 및 과전류 보호 기능은 마이크로프로세서의 프로그램을 개발하여 수행하였다.

퍼지필터와 ART2를 이용한 선박용 용접기술개발 (A Studying on Gap Sensing using Fuzzy Filter and ART2)

  • 김관형;이재현;이상배
    • 한국항만학회지
    • /
    • 제14권3호
    • /
    • pp.321-329
    • /
    • 2000
  • Welding is essential for the manufacture of a range of engineering components which may vary from very large structures such as ships and bridges to very complex structures such as aircraft engines, or miniature components for microelectronic applications. Especially, a domestic situation of the welding automation is still depend on the arc sensing system in comparison to the vision sensing system. Specially, the gap-detecting of workpiece using conventional arc sensor is proposed in this study. As a same principle, a welding current varies with the size of a welding gap. This study introduce to the fuzzy membership filter to cancel a high frequency noise of welding current, and ART2 which has the competitive learning network classifies the signal patterns the filtered welding signal. A welding current possesses a specific pattern according to the existence or the size of a welding gap. These specific patterns result in different classification in comparison with an occasion for no welding gap. The patterns in each case of 1mm, 2mm, 3mm and no welding gap are identified by the artificial neural network.

  • PDF

The damping efficiency of vortex-induced vibration by tuned-mass damper of a tower-supported steel stack

  • Homma, Shin;Maeda, Junji;Hanada, Naoya
    • Wind and Structures
    • /
    • 제12권4호
    • /
    • pp.333-347
    • /
    • 2009
  • Many tower-supported steel stacks have been constructed in Japan, primarily for economic reasons. However the dynamic behavior of these stacks under a strong wind is not well known and the wind load design standard for this type of a stack has not yet been formulated. In light of this situation, we carried out wind response observation of an operating tower-supported steel stack with and without a tuned-mass damper. The observation revealed the performance of the tuned-mass damper installed on the stack in order to control the wind-induced vibration. Based on the observed data, we performed a wind tunnel test of a specimen of the stack. In this paper we report the results of the wind tunnel test and some comparisons with the results of observation. Our findings are as follows: 1) the tuned-mass damper installed on the specimen in the wind tunnel test worked as well as the one on the observed stack, 2) the amplitude of the vortex-induced vibration of the specimen corresponded approximately to that of the observed stack, and 3) correlation between Scruton number and reduced amplitude, y/d, (y is amplitude, d is diameter) was confirmed by both the wind tunnel test and the observed results.

발전기 변류기 건전성 확보를 위한 연구 (Activities to attain integrity of generator current transformer)

  • 조철환;조성태;양경현;안경재;이형우
    • 동력기계공학회지
    • /
    • 제16권1호
    • /
    • pp.19-23
    • /
    • 2012
  • This thesis is the result of conducting an analysis to find the solution to the phenomenon of power stoppage due to the disconnection of a CT (Current Transformer) because of vibration. The CT which measures the most essential current is used in power industries as part of a generator protection relay. When it comes to the bottom plate of a CT, nonconductor; such as bakelite and laminates; these material elements should be used because it is impossible to utilize the conductor when measuring the current of a generator which carries a high current if you use other materials. These nonconductor's material properties are irregular and interpretation errors often occur because the weight is light. In addition, since the change of dynamic characteristics which are related to the temperature often occur, it is important to match the real situation by considering an error of interpretation rather than selecting the quality of the material. Lastly, the conclusion that the study drew is that it is possible to avoid the resonance by utilizing three changes to the components to solve the problem concerning the high vibration which is caused by non-conductive objects. These changes are the most crucial points in this thesis: First, material changes to the Plate. Second, weight changes to the Coil. Third, thickness changes to the Plate.

원전 정지냉각계통 배관 진동안전성 평가연구 (A Safety Evaluation Study by Vibration Analysis for Shutdown Cooling Piping System)

  • 이욱륜;이준신;손석만;김만희;송승용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.41-45
    • /
    • 2007
  • Palo Verde Unit 1 nuclear power station which is located in Arizona, USA had been operating at reduced power levels around 25% since December 25, 2005 due to vibration in one of its shutdown cooling lines. During an outage from March 18, 2006 to July 7, 2006 the necessary work and modifications to remedy the situation were performed. It cost approximately $46million to buy electricity to replace that lost as a result of this event. Therefore in this study, the vibration of shutdown cooling lines in the same nuclear power plant in Korea as Palo Verde Unit 1 should be measured by the operating condition of power plant. And it was evaluated using the expression for allowable velocity in ASME OM-S/G-2003. From the result of this study it is evaluated whether it is safe or not. If not the countermeasure should be considered in this study.

  • PDF

Research Advances on Tension Buckling Behaviour of Aerospace Structures: A Review

  • Datta, Prosun Kumar;Biswas, Sauvik
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제12권1호
    • /
    • pp.1-15
    • /
    • 2011
  • This paper reviews most of the research done in the field of tensile buckling characteristics pertaining to aerospace structural elements with special attention to local buckling and parametric excitation due to periodic loading on plate and shell elements. The concepts of buckling in aerospace structures appear as the result of the application of a global compressive applied load or shear load. A less usual situation is the case, in which a global tensile stress creates buckling instability and the formation of complex spatial buckling pattern. In contrast to the case of a pure compression or shear load, here the applied macroscopic load has no compressive component and is thus globally stabilizing. The instability stems from a local compressive stress induced by the presence of a defect, such as a crack or a hole, due to partial or non-uniform applied load at the far end. This is referred to as tensile buckling. This paper discusses all aspects of tensile buckling, theoretical and experimental. Its far reaching applications causing local instability in aerospace structural components are discussed. The important effects on dynamic stability behaviour under locally induced periodic compression have been identified and influences of various parameters are discussed. Experimental results on simple and combination resonance characteristics on plate structures due to tensile buckling effects are elaborated.

연료전지차용 수소배출 배관 및 배관이음매 안전성 평가를 위한 기초 연구 (The Basic Study on the Leak Test Method of the Hydrogen Exhaust Pipe for a Fuel Cell Vehicle)

  • 서호철;박경석;서경두;용기중
    • 한국정밀공학회지
    • /
    • 제28권2호
    • /
    • pp.185-192
    • /
    • 2011
  • This study deals with a basic proposal to prove the safety for the exhausted fittings of the hydrogen fuel cell vehicle. First, this study was approached to numerical analysis solving to close the exact boundary condition (Axial, Bending, Lateral) and the second, this study produced the Lateral movement equipment for the vibration. For the numerical analysis, This study was considered with the exact solution of Lateral movement and the resonance effect for durability sample according to fitting positions. The second, This study was made for special equipment for displacement/gas leak and the frequency because the domestic samples were comparing with foreign fitting and foreign fitting for the hydrogen fuel cell vehicle. The result of this study was satisfied with domestic fittings for the basic reference but it need more test because of other situation for hydrogen fuel cell vehicle.

A Case of Inguinal Sparganosis Mimicking Myeloid Sarcoma

  • Yeo, Jin Yeob;Han, Jee Young;Lee, Jung Hwan;Park, Young Hoon;Lim, Joo Han;Lee, Moon Hee;Kim, Chul Soo;Yi, Hyeon Gyu
    • Parasites, Hosts and Diseases
    • /
    • 제50권4호
    • /
    • pp.353-355
    • /
    • 2012
  • We report here a case of inguinal sparganosis, initially regarded as myeloid sarcoma, diagnosed in a patient undergone allogeneic hematopoietic transplantation (HSCT). A 56-year-old male patient having myelodysplastic syndrome was treated with allogeneic HSCT after myeloablative conditioning regimen. At day 5 post-HSCT, the patient complained of a painless palpable mass on the left scrotum and inguinal area. Pelvic magnetic resonance imaging and computed tomography revealed suspected myeloid sarcoma. Gun-biopsy was performed, and the result revealed eosinophilic infiltrations without malignancy. Subsequent serologic IgG antibody test was positive for sparganum. Excisional biopsy as a therapeutic diagnosis was done, and the diagnosis of sparganosis was confirmed eventually. This is the first report of sparganosis after allogeneic HSCT mimicking myeloid sarcoma, giving a lesson that the physicians have to consider the possibility of sparganosis in this clinical situation and perform adequate diagnostic and therapeutic approaches.

사각헝 탱크 구조의 접수 진동 특성에 관한 연구 (Analytical and Experimental Study on Vibration Characteristics for Rectangular Tank Structure Filled with Fluid)

  • 최수현;김극수;손성완
    • 한국소음진동공학회논문집
    • /
    • 제12권3호
    • /
    • pp.195-203
    • /
    • 2002
  • In the engine room and the aft part areas of the ship, there exist so many tank structures contacting with fresh water or sea water or oil. If these structures exhibit excessive vibrations during the sea trials, it takes a lot of cost, time and effort to improve vibration situation because the reinforcement work requires emptying the fluid out of the tanks, additional welding and special painting. It is therefore very important to predict a precise vibration characteristics of the tank structures at the design stage, however it is not easy to estimate vibration characteristics of the structures because of difficulties for accurate evaluation of the added (or virtual) mass effect due to the fluid inside the tank. In this paper, numerical and experimental approaches have been performed to present same fundamental data necessary for anti-vibration design of tank structures contacting with fluid, by investigating vibration behaviors of rectangular tank structure for various water depths.