• Title/Summary/Keyword: Resonance Type

Search Result 1,096, Processing Time 0.022 seconds

Interference Issuses of Radio Frequency Identification Devices in Magnetic Resonance Imaging Systems and Computed Tomography Scan

  • Periyasamy, M.;Dhanasekaran, R.
    • Journal of Magnetics
    • /
    • v.20 no.3
    • /
    • pp.295-301
    • /
    • 2015
  • We evaluated certain issues related to magnetic resonance imaging (MRI) coupled with the use of active 2.5 GHz radio frequency identification (RFID) tags for patient identification using low field (0.3 T) MRI and computed tomography (CT) scans. We also investigated the performance of the RFID reader located outside the MRI room by considering several factors. A total of ten active RFID tags were exposed to several MRI sequences and X-rays of CT scan. We found that only card type active RFID tags are suitable for patient identification purpose in MRI environment and both wristbands as well as card tags were suitable for the same in CT environment. Severe artifacts were found in the captured MRI and CT images when the area of the imaging was in proximity to the tags. No external factors affected the performance of active RFID reader stationed outside the MRI scan room.

Independent Color Filtering of Differently Polarized Light Using Metal-Insulator-Metal Type Guided Mode Resonance Structure

  • Jung, Young Jin;Park, Namkyoo
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.180-187
    • /
    • 2016
  • The independent operation of a color filter for incident polarization is demonstrated using a guided-mode resonance (GMR) filter employing a metal-insulator-metal (MIM) waveguide. To achieve independent operation, a rectangular MIM grating is proposed as a wave-guide resonator. The design considerations are discussed and include how to determine the grating period and slit width. Power flow distribution is observed with slit width variation. Blue-green, green-red, and blue-red filters for corresponding x- and y-polarizations are demonstrated as application examples with numerical simulation with rectangle-shaped MIM grating. As a practical application, feasibility as a chromatic polarizer is discussed.

Combination resonances of imperfect SSFG cylindrical shells rested on viscoelastic foundations

  • Foroutan, Kamran;Ahmadi, Habib
    • Structural Engineering and Mechanics
    • /
    • v.75 no.1
    • /
    • pp.87-100
    • /
    • 2020
  • The present paper investigates the combination resonance behavior of imperfect spiral stiffened functionally graded (SSFG) cylindrical shells with internal and external functionally graded stiffeners under two-term large amplitude excitations. The structure is embedded within a generalized nonlinear viscoelastic foundation, which is composed of a two-parameter Winkler-Pasternak foundation augmented by a Kelvin-Voigt viscoelastic model with a nonlinear cubic stiffness, to account for the vibration hardening/softening phenomena and damping considerations. With regard to classical plate theory of shells, von-Kármán equation and Hook law, the relations of stress-strain are derived for shell and stiffeners. The spiral stiffeners of the cylindrical shell are modeled according to the smeared stiffener technique. According to the Galerkin method, the discretized motion equation is obtained. The combination resonance is obtained by using the multiple scales method. Finally, the influences of the stiffeners angles, foundation type, the nonlinear elastic foundation coefficients, material distribution, and excitation amplitude on the system resonances are investigated comprehensively.

Modification and Testing to Prevent the Resonance in a Finger-type Low Pressure Turbine Blade (저압 터빈용 Finger 형 블레이드의 공진 방지를 위한 개선 및 시험)

  • Ha, Hyun-Cheon;Lee, Dong-Jin;Ryu, Seok-Ju;Chung, Hee-Chan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.612-617
    • /
    • 2000
  • This paper describes the experience gained from the treatments for prevention of blade failure occurred in the low-pressure turbine. Some cracks due to high cycle fatigue were found at the blades in low-pressure turbines after long time operation. Such failure was mainly caused by the resonance of the blade with the vane passing frequency excitation. If a natural frequency of the blade exists near the excitation frequency, a resonant vibration can occur and leads to a large amount of stress which may cause fatigue failures in turbine blades. To avoid the resonance of the blade, some modifications have been performed and full-scaled mockup testing has been done to confirm the verification for modification. Test result shows that enlarging the span cover is very useful to change the natural frequency of the grouped blades effectively.

  • PDF

Retropharyngeal Tenosynovial Giant Cell Tumor Misdiagnosed as Oropharyngeal Cancer: a Case Report

  • Jung, Mi Ran;Lee, Jee Young;Kim, Sang Yoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.4
    • /
    • pp.272-276
    • /
    • 2018
  • Extra-articular tenosynovial giant cell tumor (TS-GCT) in retropharyngeal space is a rare case. We found only two case reports in the literature, in which one was located in retropharynx or prevertebral space of the cervical spine. We describe a rare case of TS-GCT in the retropharynx, which was initially misdiagnosed as oropharyngeal cancer. Furthermore, we want to assure that extraarticular diffuse type TS-GCT should be considered in the differential diagnosis of lesions showing low signal intensity in MRI scan.

Use of Cardiac Computed Tomography and Magnetic Resonance Imaging in Case Management of Atrial Fibrillation with Catheter Ablation

  • Hee-Gone Lee;Jaemin Shim;Jong-il Choi;Young-Hoon Kim;Yu-Whan Oh;Sung Ho Hwang
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.695-708
    • /
    • 2019
  • Atrial fibrillation (AF) is the most common arrhythmia associated with the risk of morbidity and mortality in clinical patients. AF is considered as an arrhythmia type that develops and progresses through close connection with cardiac structural arrhythmogenic substrates. Since the introduction of catheter ablation-mediated electrical isolation of arrhythmogenic substrates, cardiac imaging indicates improved treatment outcome and prognosis with appropriate candidate selection, ablation catheter guidance, and post-ablation follow-up. Currently, cardiac computed tomography (CCT) and cardiovascular magnetic resonance (CMR) imaging are essential in the case management of AF at both pre-and post-procedural stages of catheter ablation. In this review, we discuss the roles and technical considerations of CCT and CMR imaging in the management of patients with AF undergoing catheter ablation.

Preparation and Characterization of the L-prolino Co(III) Complexes with the Tetradentate $N_2O_2$-type Ligands

  • Jin-Seung Jung;Cheal Kim;Moo-Jin Jun
    • Bulletin of the Korean Chemical Society
    • /
    • v.11 no.3
    • /
    • pp.235-238
    • /
    • 1990
  • Complexes of the type[Co(T)(L-pro)], where T is the quadridentate $N_2O_2$-type ligand, N,N'-dimethylethylenediamine-N,N'-diacetate or N,N'-dimethylethylenediamine-N,N'-di-$\alpha$-butyrate, have been prepared. The complexes were separated into the two stereoisomers, $\Delta$-s-cis-[Co(T)(L-pro)] and $\Lambda$-s-cis-[Co(T)(L-pro)]. They were characterized by their proton magnetic resonance, absorption and circular dichroism spectra, elemental analyses.

The Vibration Characteristic Improvement by Mode Variation of Ring Type Ultrasonic Motor (리형 초음파모터의 모드가변에 따른 진동특성 개선)

  • 윤신용;김수석
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.115-124
    • /
    • 2004
  • This paper suggested the vibration characteristic improvement by variation mode of ring type ultrasonic motor. Design for the piezoelectric ceramic and elastic body of stator were calculated by the finite element method(FEM) that consider the resonance frequency, vibration mode and coupling efficiency etc. Through the result of vibration analysis from 6 order mode to 8 mode, the 7 order mode was gained very an excellent results that it was the coupling efficient, minimum power loss and bending vibration value. Here over 7 order mode, was acquired that an output current for input voltage was very a large increased results. The result of vibration calculation, from thickness 0.5[mm] to 2[mm], know the fact that the vibration displacement at 0.5[mm] is an high value too. From such analysis result, this paper was manufactured the ultrasonic motor of outer diameter 50[mm], inter 22[mm] having the about 43.86[KHz] resonance frequency. We have gated that a simulation result is 42.2[KHz] and an experiment result is 43.86[KHz]. Then, a propriety of this paper was established the result almost similar to though comparison, investigation of simulation and experiment result.

Added Predictive Values of Proton Density Magnetic Resonance Imaging on Posterior Communicating Artery Aneurysms and Surrounding Soft Tissues with Simple Classification

  • Sun Yoon;Min Jeoung Kim;Hyun Jin Han;Keun Young Park;Joonho Chung;Yong Bae Kim
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.4
    • /
    • pp.418-425
    • /
    • 2023
  • Objective : Deciphering the anatomy of posterior communicating artery (PCoA) aneurysms in relation to surrounding structures is essential to determine adjuvant surgical procedures. However, it is difficult to predict surgical structures through preoperative imaging studies. We aimed to present anatomical structures using preoperative high-resolution three-dimensional proton density-weighted turbo spin-echo magnetic resonance (PDMR) imaging with simple classification. Methods : From January 2020 to April 2022, 30 patients underwent PDMR before microsurgical clipping for unruptured PCoA aneurysms in a single tertiary institute. We retrospectively reviewed the radiographic images and operative data of these patients. The structural relationship described by PDMR and intraoperative findings were compared. Subsequently, we classified aneurysms into two groups and analyzed the rate of adjuvant surgical procedures and contact with the surrounding structures. Results : Correlations between preoperative PDMR predictions and actual intraoperative findings for PCoA aneurysm contact to the oculomotor nerve, temporal uncus, and anterior petroclinoid fold (APCF) reported a diagnostic accuracy of 0.90, 0.87, and 0.90, respectively. In 12 patients (40.0%), an aneurysm dome was located on the plane of the oculomotor triangle and was classified as the infratentorial type. Compared to the supratentorial type PCoA aneurysm, adjuvant procedures were required more frequently (66.7% vs. 22.2%, p=0.024) for infratentorial type PCoA aneurysm clipping. Conclusion : Preoperative PCoA aneurysm categorization using PDMR can be helpful for predicting surgical complexity and planning of microsurgical clipping.

Magnetic Resonance Imaging Analysis of Intervertebral Disc Change of Several Spondylolisthesis Patients in Fifties : Comparison Lytic and Degenerative Spondylolisthesis (일부 50대 척추전방전위증 환자의 유형별 자기공명영상상 추간판 변형 형태 고찰)

  • Kim, Seok;Bahn, Hyo-Jung;Yoon, Hyun-Seok;Han, Kyung-Wan;Woo, Jae-Hyuk
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.6 no.2
    • /
    • pp.13-22
    • /
    • 2011
  • Objectives : The purpose of this study is to find out the characteristics of intervertebral disc changes and relative factors of the spondylolisthesis patients in fifties by type of spondylolisthesis. Methods : We investigated 69 cases of patients who visited one Korean traditional medicine hospital and were diagnosed as spondylolisthesis on L-spine X-ray and L-spine magnetic resonance imaging(MRI). We selected 37 lytic spondylolisthesis patients and 32 degenerative spondylolisthesis patients. We analysed the relativity between the numbers of changed discs, types of changed disc, locations of nerve compression and types of spondylolisthesis. Results : 1. The number of changed discs increase in lytic type, but there is no statistically significant difference. 2. Bulging disc is the dominant type of disc change. There is no significant difference between two types. 3. Both foraminal type was shown dominantly in lytic spondylolisthesis, diffuse type in degenerative spondylolisthesis by the analysis of the location of the nerve compression. But the symptoms of patients and dermatome did not match in most of the cases. Conculsions : The direction of nerve compression is different while the disc changing aspects are similar in both types. In several spondylolisthesis patients in fifties, symptoms of patient are related to degeneration of vertebrae, not to the type of spondylolisthesis.

  • PDF