• 제목/요약/키워드: Resonance Frequency Shift

검색결과 85건 처리시간 0.025초

Resonance Characteristics of THz Metamaterials Based on a Drude Metal with Finite Permittivity

  • Jun, Seung Won;Ahn, Yeong Hwan
    • Current Optics and Photonics
    • /
    • 제2권4호
    • /
    • pp.378-382
    • /
    • 2018
  • In most previous investigations of plasmonic and metamaterial applications, the metallic film has been regarded as a perfect electrical conductor. Here we demonstrate the resonance characteristics of THz metamaterials fabricated from metal film that has a finite dielectric constant, using finite-difference time-domain simulations. We found strong redshift and spectral broadening of the resonance as we decrease the metal's plasma frequency in the Drude free-electron model. The frequency shift can be attributed to the effective thinning of the metal film, originating from the increase in penetration depth as the plasma frequency decreases. On the contrary, only peak broadening occurs with an increase in the scattering rate. The metal-thickness dependence confirms that the redshift and spectral broadening occur when the effective metal thickness drops below the skin-depth limit. The electromagnetic field distribution illustrates the reduced field enhancement and reduced funneling effects near the gap area in the case of low plasma frequency, which is associated with reduced charge density in the metal film.

이중 질량체를 사용한 진동형 자이로스코프의 검출부 대역폭 개선 (Improvement of Sense Mode Bandwidth of Vibratory Silicon-On-Glass Gyroscope Using Dual-Mass System)

  • 황영석;김용권;지창현
    • 전기학회논문지
    • /
    • 제60권9호
    • /
    • pp.1733-1740
    • /
    • 2011
  • In this research, a MEMS vibratory gyroscope with dual-mass system in the sensing mode has been proposed to increase the stability of the device using wide bandwidth. A wide flat region between the two resonance peaks of the dual-mass system removes the need for a frequency matching typically required for single mass vibratory gyroscopes. Bandwidth, mass ratio, spring constant, and frequency response of the dual-mass system have been analyzed with MATLAB and ANSYS simulation. Designed first and second peaks of sensing mode are 5,917 and 8,210Hz, respectively. Driving mode resonance frequency of 7,180Hz was located in the flat region between the two resonance peaks of the sensing mode. The device is fabricated with anodically bonded silicon-on-glass substrate. The chip size is 6mm x 6mm and the thickness of the silicon device layer is $50{\mu}m$. Despite the driving mode resonance frequency decrease of 2.8kHz and frequency shift of 176Hz from the sensing mode due to fabrication imperfections, measured driving frequency was located within the bandwidth of sensing part, which validates the utilized dual-mass concept. Measured bandwidth was 768Hz. Sensitivity calculated with measured displacement of driving and sensing parts was 22.4aF/deg/sec. Measured slope of the sensing point was 0.008dB/Hz.

완전발달 난류 원관 유동에서의 3T 및 7T MRI를 이용한 자기공명온도계의 적용 (Application of Magnetic Resonance Thermometry (MRT) on Fully Developed Turbulent Pipe Flow using 3T and 7T MRI)

  • 류형우;백승찬;김동현;이활;오석훈;황원태
    • 한국가시화정보학회지
    • /
    • 제18권1호
    • /
    • pp.26-37
    • /
    • 2020
  • Magnetic resonance thermometry (MRT) is a technique capable of measuring three-dimensional mean temperature fields by utilizing temperature-dependent shifts in proton resonance frequency. In this study, experimental verification of the technique is obtained by measuring 3D temperature fields within fully developed turbulent pipe flow, using 3T and 7T MRI scanners. The effect of the proton resonance frequency (PRF) thermal constant is examined in detail.

듀얼 모드 위상 시프트 ZVS PWM 제어 고주파 공진형 인버터를 이용한 IH 온수기 (Induction Heating Water Heater using Dual Mode Phase Shifted ZVS-PWM High Frequency Resonant Inverter)

  • 정상석;유의정;우경일;박한석
    • 전기학회논문지P
    • /
    • 제67권2호
    • /
    • pp.82-89
    • /
    • 2018
  • This paper presents a novel prototype of dual mode control based phase shift ZVS PWM high frequency load resonant inverter with lossless snubber capacitors in addition to a single active auxiliary resonant snubber for electromagnetic induction heating(IH) foam metal based consumer fluid dual packs(DPA) heater. The operating principle in steady state and unique features of this voltage source soft switching high frequency inverter circuit topology are described in this paper. The lossless snubber and auxiliary active resonant snubber assisted constant frequency phase shift ZVS PWM high frequency load resonant inverter employing IGBT power modules actually is capable of achieving zero voltage soft commutation over a widely specified power regulation range from full power to low power. The steady state operating performances of this dual mode phase shift PWM series load resonant high frequency inverter are evaluated and discussed on the basis of simulation and experimental results for induction heated foam metal heater which is designed for compact and high efficient moving fluid heating appliance in the consumer pipeline systems.

비선형 초음파공명 특성을 이용한 미세균열 탐지 (Detection of Micro-Crack Using a Nonlinear Ultrasonic Resonance Parameters)

  • 정용무;이덕현
    • 비파괴검사학회지
    • /
    • 제32권4호
    • /
    • pp.369-375
    • /
    • 2012
  • 기존 비파괴평가 기술의 결함 탐지 한계를 극복하기 위하여 비선형 초음파공명 특성을 이용한 미세 균열 진단 기술을 개발하였다. 가진 전압에 따른 초음파공명 주파수의 천이현상과 정규화 공명 진폭 감소 현상을 비선형 초음파공명 특성 파라미터로 제안하였으며 이를 실험적으로 확인하였다. CT 시편에 피로시험을 통하여 미세한 자연 균열을 생성하였으며 피로 사이클 단계마다 초음파공명주파수와 정규화 공명진폭의 변화를 측정하였다. 무결함 또는 10 ${\mu}m$ 정도의 매우 미세한 균열이 존재하는 시편에서는 초음파공명 주파수 천이현상이나 정규화 공명 진폭의 변화가 나타나지 않는 반면에 30 ${\mu}m$급 이상의 미세 균열 시편에서는 균열 크기가 증가함에 따라 초음파공명주파수의 천이 현상이나 정규화 공명 진폭의 감소량이 증가함을 확인하였다.

Experimental Studies on Plasmon Resonance of Ag Nanoparticles on Highly Ordered Pyrolytic Graphite (HOPG)

  • Lopez Salido, Ignacio;Bertram, Nils;Lim, Dong-Chan;Gantefor, Gerd;Kim, Young-Dok
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권4호
    • /
    • pp.556-562
    • /
    • 2006
  • Studies on Ag nanoparticles grown on Highly Ordered Pyrolytic Graphite (HOPG) using HREELS provide different results for smaller and larger particle sizes corresponding to Ag coverages below and above 4 monolayers, respectively. For the larger particles, a positive frequency shift with decreasing particle size and a broadening of the plasmon resonance were observed with decreasing particle size, in line with previous studies on Ag on alumina. For the smaller particles, in contrast, a shift to lower energy with decreasing particle size, and a narrowing of the plasmon resonance with decreasing particle size can be found. The asymmetry of the Ag-features present for Ag coverages above 4 monolayers disappears for Ag coverages below 4 monolayers. The result for the smaller particles can be rationalized in terms of change of the particle growth mode with increasing particle size, which corroborates our STM data, as well as electronic effects due to the metal/support charge transfer.

고속 마이크로 외팔보 공진시험을 통한 나노스케일 티타늄 박막의 탄성계수 평가 (High-speed Microcantilever Resonance Testing on the Young's Modulus of a Nanoscale Titanium Film)

  • 김윤영
    • 한국표면공학회지
    • /
    • 제50권5호
    • /
    • pp.392-397
    • /
    • 2017
  • The Young's modulus of a nanoscale titanium (Ti) thin-film was evaluated using a high-speed microcantilever resonating at the megahertz frequency in the present study. A 350 nm thick Ti film was deposited on the surface of a silicon microcantilever, and the morphology of the film was analyzed using the atomic force microscopy. The microcantilever was excited to resonate using an ultrasonic pulser that generates tone burst signals and the resonance frequency shift induced by the deposition of Ti was measured using a Michelson interferometer. The Young's modulus was determined through a modal analysis using the finite element method and the result was validated by the nanoindentation testing, showing good agreement within a relative error of 1.0%. The present study proposes a nanomechanical characterization technique with enhanced accuracy and sensitivity.

Noise Lowering for a Large Variable Speed Range Use Permanent Magnet Motor by Frequence Shift and Structural Response Evaluation of Electromagnetic Forces

  • Arata, Masanori;Takahashi, Norio;Fujita, Masafumi;Mochizuki, Motoyasu;Araki, Takashi;Hanai, Takashi
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.67-74
    • /
    • 2012
  • According to electrical output up rating of a permanent magnet motor and request to operate for a large variable speed range, resonance between structural natural vibration and electromagnetic force inside the motor can take place and make noise. This paper describes the mechanism of a resonance between them and noise lowering procedure by frequency shift when they are applied to the reluctance torque largely employed new motor named Permanent magnet Reluctance Motor (PRM).

TFT-LCD 구동회로에서의 EMI 개선을 위한 Power/Ground Plane 모델링 및 실험적 검증 (Power/Ground Plane Modeling and Experimental Characterization for EMI Improvement in TFT-LCD Driving Circuit)

  • 조강연;나완수;이재훈;이성규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.44-47
    • /
    • 2005
  • This paper presents the efficient plan for the EMI improvement from of TFT-LCD Module. It investigates the frequency characteristics of Power/Ground Plane of TFT-LCD drive circuit PCB concretely. After the frequency characteristics is reviewed, EMI improvement is tried to insert to RC termination between Power/Ground Plane and to shift resonance frequency. It is confirmed by a simulation result and RC Termination which is inserted the point where the resonance characteristics change is necessary. It applied in 19 "SXGA TFT-LCD drive circuits and the EMI improvement verification is described.

  • PDF

시간 평균 ESPI를 이용한 진동 물체의 공진 주파수 검출 신뢰도 검증에 대한 연구 (A Study on Reliability Verification of Resonance Frequency Detection of Vibration Object using Time-average ESPI)

  • 홍경민;유원재;강영준;이동환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.930-933
    • /
    • 2005
  • Non-destructive inspection techniques using laser have been breading their application areas as well as growing their measurement skills together with the rapid development of circumferential technology like fiber optics. computer and image processing The ESPI technique is already on the stage of on-line testing with commercial products in developed country nations. Especially, this technique is expected to be applied to the nuclear industry, automobile and aerospace because it is proper for the vibration measurement and it can be applied to objects of a high temperature. This paper describes the use of the ESPI system for measuring vibration patterns on the reflecting objects. Using this system, high-quality Jo fringes for identifying mode shapes are displayed. A bias vibration is introduced into the reference beam to shift the Jo fringes so that fringe shift algorithms can be used to determine vibration amplitude. Using this method. amplitude fields for vibrating objects were obtained directly from the time-average interferometer recorded by the ESPI system.

  • PDF