• 제목/요약/키워드: Resonance Cross Section

검색결과 98건 처리시간 0.026초

Scattering characteristics of metal and dielectric optical nano-antennas

  • Ee, Ho-Seok;Lee, Eun-Khwang;Song, Jung-Hwan;Kim, Jinhyung;Seo, Min-Kyo
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.76.1-76.1
    • /
    • 2015
  • Optical resonances of metallic or dielectric nanoantennas enable to effectively convert free-propagating electromagnetic waves to localized electromagnetic fields and vice versa. Plasmonic resonances of metal nanoantennas extremely modify the local density of optical states beyond the optical diffraction limit and thus facilitate highly-efficient light-emitting, nonlinear signal conversion, photovoltaics, and optical trapping. The leaky-mode resonances, or termed Mie resonances, allow dielectric nanoantennas to have a compact size even less than the wavelength scale. The dielectric nanoantennas exhibiting low optical losses and supporting both electric and magnetic resonances provide an alternative to their metallic counterparts. To extend the utility of metal and dielectric nanoantennas in further applications, e.g. metasurfaces and metamaterials, it is required to understand and engineer their scattering characteristics. At first, we characterize resonant plasmonic antenna radiations of a single-crystalline Ag nanowire over a wide spectral range from visible to near infrared regions. Dark-field optical microscope and direct far-field scanning measurements successfully identify the FP resonances and mode matching conditions of the antenna radiation, and reveal the mutual relation between the SPP dispersion and the far-field antenna radiation. Secondly, we perform a systematical study on resonant scattering properties of high-refractive-index dielectric nanoantennas. In this research, we examined Si nanoblock and electron-beam induced deposition (EBID) carbonaceous nanorod structures. Scattering spectra of the transverse-electric (TE) and transverse-magnetic (TM) leaky-mode resonances are measured by dark-field microscope spectroscopy. The leaky-mode resonances result a large scattering cross section approaching the theoretical single-channel scattering limit, and their wide tuning ranges enable vivid structural color generation over the full visible spectrum range from blue to green, yellow, and red. In particular, the lowest-order TM01 mode overcomes the diffraction limit. The finite-difference time-domain method and modal dispersion model successfully reproduce the experimental results.

  • PDF

H-형태 소형 개구를 가진 직사각형 도파관 탐침의 공진 투과 (Resonant Transmission of a Rectangular Waveguide Probe with H-type Small Aperture)

  • 고지환;조영기
    • 한국전자파학회논문지
    • /
    • 제24권12호
    • /
    • pp.1198-1204
    • /
    • 2013
  • 근접장 마이크로파 현미경에 사용되는 도파관 탐침 구조에 대해 기존의 폭이 좁은 사각형 개구를 대신하여 H-형태 개구 구조를 제안하였고, 두 구조의 성능 평가지표로서 투과 효율과 스팟 크기를 비교 분석하였다. 비교결과로 투과 효율은 비슷하였지만, 스팟 크기 면에서는 H-형태 개구 구조가 훨씬 작아서 해상도 측면에서 개선된 형태의 탐침 구조로 사용될 수 있음을 확인하였다. 이런 H-형태 개구의 이점을 이용하면 광 정보 저장, 나노리소그래픽, 나노 현미경과 같은 근접장 광학 장치가 상당히 성능 개선될 것이다. 또한, 도파관 탐침에 공진기가 부착된 구조에서 투과 효율이 향상됨을 확인하였다.

Design and Fabrication of Stratified Microwave Absorbing Structure Consisted of Glass/Epoxy - Resistive Sheet - Foam

  • Choi, Won-Ho;Shin, Jae-Hwan;Song, Tae-Hoon;Lee, Won-Jun;Kim, Chun-Gon
    • Composites Research
    • /
    • 제27권6호
    • /
    • pp.225-230
    • /
    • 2014
  • In this study, a novel microwave absorber which consists of a structural part, a resistive sheet, and a low dielectric layer is proposed. Unlike the conventional Salisbury screen, a newly proposed absorber is capable of a range of absorbing performance, from narrowband to broadband. In the case of the narrowband absorber, the fabricated absorber with optimized design parameters has a strong resonance at 9.25 GHz and reflection loss of -44 dB with satisfying the -10 dB absorption in whole X-band (8.2 GHz~12.4 GHz). For the broadband absorber design, the reflectivity was minimized in the considered frequency ranges. The designed absorber showed two weak resonances near 6.5 GHz and 16.5 GHz and satisfied the -10 dB absorption from C-band to Ku-band (4 GHz~18 GHz). The measured reflection loss of fabricated absorber was well matched with simulation results, though the measurement was only performed on X-band. For the Salisbury screen to be capable of broadband absorption, it should be stacked multiply in a structure known as the Jaumann absorber. However, for the microwave absorber presented here, broadband as well as narrowband capabilities can be implemented without a change of the structure.

Experimental Investigations on Upper Part Load Vortex Rope Pressure Fluctuations in Francis Turbine Draft Tube

  • Nicolet, Christophe;Zobeiri, Amirreza;Maruzewski, Pierre;Avellan, Francois
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권1호
    • /
    • pp.179-190
    • /
    • 2011
  • The swirling flow developing in Francis turbine draft tube under part load operation leads to pressure fluctuations usually in the range of 0.2 to 0.4 times the runner rotational frequency resulting from the so-called vortex breakdown. For low cavitation number, the flow features a cavitation vortex rope animated with precession motion. Under given conditions, these pressure fluctuations may lead to undesirable pressure fluctuations in the entire hydraulic system and also produce active power oscillations. For the upper part load range, between 0.7 and 0.85 times the best efficiency discharge, pressure fluctuations may appear in a higher frequency range of 2 to 4 times the runner rotational speed and feature modulations with vortex rope precession. It has been pointed out that for this particular operating point, the vortex rope features elliptical cross section and is animated of a self-rotation. This paper presents an experimental investigation focusing on this peculiar phenomenon, defined as the upper part load vortex rope. The experimental investigation is carried out on a high specific speed Francis turbine scale model installed on a test rig of the EPFL Laboratory for Hydraulic Machines. The selected operating point corresponds to a discharge of 0.83 times the best efficiency discharge. Observations of the cavitation vortex carried out with high speed camera have been recorded and synchronized with pressure fluctuations measurements at the draft tube cone. First, the vortex rope self rotation frequency is evidenced and the related frequency is deduced. Then, the influence of the sigma cavitation number on vortex rope shape and pressure fluctuations is presented. The waterfall diagram of the pressure fluctuations evidences resonance effects with the hydraulic circuit. The influence of outlet bubble cavitation and air injection is also investigated for low cavitation number. The time evolution of the vortex rope volume is compared with pressure fluctuations time evolution using image processing. Finally, the influence of the Froude number on the vortex rope shape and the associated pressure fluctuations is analyzed by varying the rotational speed.

호흡멈춤상태에서 K-space분할 CINE 자기공명 영상기법을 이용한 관상동맥우회로의 혈류개방성의 검사 (Assessment of Patency of Coronary Artery Bypass Grafts Using Segmented K-space Breath-hold Cine Cardiovascular Magnetic Resonance Imaging: A Clinical Feasibility Study)

  • Oh-Choon Kwon;Sub Lee;Jong-Ki Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • 제7권1호
    • /
    • pp.22-30
    • /
    • 2003
  • 목적 : 본 연구에서는 호흡멈춤 K-space 분할 2D-FASTCARD 자기공명영상 기법에 의한 관상동맥우회로내의 혈류개방성 검사의 임상 적 유용성을 조사하였다. 대상 및 방법: 관상동맥우회로 시술을 한 38명의 환자에서 내유동맥의 수는 36개이었고 대복제정맥편은 56개였다. 2차원 FASTCARD 기법을 이용하여 sagittal과 transverse평면에서 13-18초 동안 호흡을 멈추고 영상을 심장박동주기에 맞추어 획득하였다. 신호크기-영상의 hard copy를 이용하여 관상동맥우회로가 예상되는 지점에서 혈류에 의한 작은 원형부분이 밝게 보이면 해당 graft가 개방되었다고 판독하였다. 결과: 시술 환자의 다양한 관상동맥우회술의 양상에 따라 분류하여 Sagittal평면과 transverse 평면에서 내유동맥편과 대복제정맥편의 개방성을 검사하였다 좌회선지관상동맥의 분지로 연결되는 대복제정맥편은 Sagittal평면에서, 좌전하행지 관상동맥 혹은 그의 분지나 우관상동맥으로 연결되는 내유동맥편 혹은 대복제정맥편은 transverse평면에서 최대 감도의 개방성 영상을 보였다. 전체 38명의 환자 중에 23명의 영상획득 가능환자에서 45개의 관상동맥우회로가 보였으며 9개가 보이지 않았다. 증상이 있던 두 명의 환자중 2개의 관상 동맥우회로가 보이지 않았다. 결론: 호흡멈춤 K-space 분할 2D-FASTCARD 자기공명영상 기법으로 관상동맥우회로의 혈류 개방성의 비침습적 평가가 가능하다. 그러나 이 방법으로 보이지 않는 관상동맥 우회로는 조영제를 사용한 자기공명 혈관조영술이나 일반 혈관조영술등의 방법으로 그 진위를 재검사하여 확진하는 것이 필요하다.

  • PDF

원통형 임피던스 튜브 내 다중 미세천공 판의 음향투과 (Sound transmission of multi-layered micro-perforated plates in a cylindrical impedance tube)

  • 김현실;마평식;김봉기;이성현;서윤호
    • 한국음향학회지
    • /
    • 제39권4호
    • /
    • pp.270-278
    • /
    • 2020
  • 본 논문은 원통형 임피던스 튜브내에 설치된 다중 미세천공판(Micro-Perforated Plate, MPP)의 음향투과를 해석적으로 구하는 방법을 다루었다. 판의 진동을 무한 급수의 합으로 전개하였는데 반경방향으로는 Bessel 함수를 포함한다. 평면파 가정하에서 저주파수 대역의 근사식을 유도하였으며 전달함수법을 이용하여 다중 MPP에 대한 음향투과율 공식을 제시하였다. 단일과 이중 MPP의 음향투과손실(Sound Transmission Loss, STL)을 본 논문에서 제안한 공식을 이용하여 계산하였으며 유한요소법(Finite Element Method, FEM)을 사용한 결과와 잘 일치 하였다. 천공율이 증가할수록 STL은 감소하는데 이는 판의 진동보다는 천공율이 더 큰 영향을 주기 때문이다. STL은 판의 공진주파수에서 골(dip)을 보이며 이중 MPP의 STL은 질량-스프링-질량 진동에 해당하는 공진주파수에서 골을 보인다. 본 연구에서 제안한 STL 예측 모델은 임의의 개수의 다중 MPP에 적용이 가능하며 각각의 판은 미세천공을 포함하거나 포함하지 않는 두 가지 경우가 모두 가능하다.

복합 플라즈몬 구조에서의 개별 모드 동작을 이용한 플라즈모닉 컬러 필터 최적의 설계 방법 (Optimal Design Method for a Plasmonic Color Filter by Using Individual Phenomenon in a Plasmonic Hybrid Structure)

  • 이용호;도윤선
    • 한국광학회지
    • /
    • 제29권6호
    • /
    • pp.275-284
    • /
    • 2018
  • 본 연구에서는 나노 홀 배열과 나노 디스크 배열이 AZ 1500 나노 기둥에 의해 분리된 하이브리드 구조의 컬러 필터 설계방법을 제시한다. 우리는 각 설계 변수에 따른 투과광 특성 변화의 경향성을 이용하여 RGB 컬러 필터 설계 방법을 제시한다. 특히, 단면에서의 전기장의 세기 분포를 분석하여 두 배열에서 각각 발생하는 국소 표면 플라즈몬 공명이 서로에게 영향을 주지 않도록 AZ 1500 나노 기둥의 높이를 설정하였다. 최적화된 컬러 필터의 투과광 특성은 다음과 같다. Red 컬러 필터의 투과광 특성은 가시광 대역에서 Red를 표현하는 파장대역이 차지하는 비율이 55.01%, 투과도 최댓값이 41.53%이다. 그리고 Green컬러 필터의 경우, Green을 표현하는 파장대역의 비율이 40.20%, 투과도 최댓값은 42.41%이다. Blue 컬러 필터의 경우, Blue를 표현하는 파장 대역의 비율이 32.78%, 투과도 최댓값은 30.27%이다. 본 연구를 통해 산업용 장치에 집적되는 컬러 필터의 특성 향상을 이끌어 낼 수 있을 것으로 예상한다.

High-Resolution Intracranial Vessel Wall MRI Findings Among Different Middle Cerebral Artery Territory Infarction Types

  • So Yeon Won;Jihoon Cha;Hyun Seok Choi;Young Dae Kim;Hyo Suk Nam;Ji Hoe Heo;Seung-Koo Lee
    • Korean Journal of Radiology
    • /
    • 제23권3호
    • /
    • pp.333-342
    • /
    • 2022
  • Objective: Intracranial atherosclerotic stroke occurs through various mechanisms, mainly by artery-to-artery embolism (AA) or branch occlusive disease (BOD). This study evaluated the spatial relationship between middle cerebral artery (MCA) plaques and perforating arteries among different MCA territory infarction types using vessel wall magnetic resonance imaging (VW-MRI). Materials and Methods: We retrospectively enrolled patients with acute MCA infarction who underwent VW-MRI. Thirty-four patients were divided into three groups according to infarction pattern: 1) BOD, 2) both BOD and AA (BOD-AA), and 3) AA. To determine the factors related to BOD, the BOD and BOD-AA groups were combined into one group (with striatocapsular infarction [BOD+]) and compared with the AA group. To determine the factors related to AA, the BOD-AA and AA groups were combined into another group (with cortical infarction [AA+]) and compared with the BOD group. Plaque morphology and the spatial relationship between the perforating artery orifice and plaque were evaluated both quantitatively and qualitatively. Results: The plaque margin in the BOD+ group was closer to the perforating artery orifice than that in the AA group (p = 0.011), with less enhancing plaque (p = 0.030). In the BOD group, plaques were mainly located on the dorsal (41.2%) and superior (41.2%) sides where the perforating arteries mainly arose. No patient in the AA group had overlapping plaques with perforating arteries at the cross-section where the perforator arose. Perforating arteries associated with culprit plaques were most frequently located in the middle two-thirds of the M1 segment (41.4%). The AA+ group had more stenosis (%) than the BOD group (39.73 ± 24.52 vs. 14.42 ± 20.96; p = 0.003). Conclusion: The spatial relationship between the perforating artery orifice and plaque varied among different types of MCA territory infarctions. In patients with BOD, the plaque margin was closer and blocked the perforating artery orifice, and stenosis degree and enhancement were less than those in patients with AA.