• Title/Summary/Keyword: Resonance Circuit

Search Result 495, Processing Time 0.022 seconds

The Power Supply for High Frequency Induction Heating by using the Current Resonance (전류공진을 이용한 고주파 유도가열용 전원장치)

  • Ra, B.H.;Lee, E.Y.;Song, D.H.;Suh, K.Y.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.263-266
    • /
    • 2002
  • In this paper, It is indicating that an issues of the conventional boost converter for high frequency induction heating. To improve those issues, it is proposed, simulated and analyzed that the current resonant circuit, simulated. As the result, we knew that the proposed circuit has a good point to improve the waveform of input current and to make high efficiency. On the other side, in the inverter for the high current power supply, it is proposed that the high frequency inverter of the half bridge topology, be done the circuit analysis to extract the optimal circuit parameter. It is making sure of the soft switching operating by the inductor to reverse parallel connected on the inverter main switch, decreasing the surge voltage when the switch is turn-off by compulsion, and repressing the switch current and bringing the high current amplitude operation by the multi resonance.

  • PDF

The Design of Acoustic Resonance Free and Dimmable Electronic Ballast for 1kW MHL (음향 공명 제거 및 조광 제어가 가능한 1kW 메탈 핼라이드 램프용 전자식 안정기 설계)

  • Lee, Bong-Jin;Park, Chong-Yun;Kim, Ki-Nam
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1782-1789
    • /
    • 2008
  • This paper presents the design of acoustic resonance(AR) free and dimmable electronic ballast for 1kW Metal-Halide Lamp(MHL). The proposed Ballast consists of a Full-Bridge(FB) rectifier, a passive power factor correction(PFC) circuit, a full-bridge inverter, an ignitor using LC resonance and a control circuit for frequency modulation and dimming control. Whereas a passive PFC provides advantages in terms of high reliability and low cost for constructing the circuit, it is difficult to supply a stable voltage because of the output voltage ripple that occurs with a period of 120Hz. Although the ballast can be designed with a small size and a light weight if it is driven at a switching frequency between 1 and 100 kHz, AR will occur if the eigenvalue frequency of the lamp coincides with the inverter's operation frequency. The operation frequency was modulated in real time according to the output voltage ripple to compensate for the variation in power supplied to the lamp and eliminate AR. For dimming, the method, which modulated drive frequency of FB inverter using the control of DC level by microprocessor, was used. The Dimming ranged at least from 600W to 1kw as rated power of the lamp with 4 stages. Performance of the proposed technique was validated through numerical analysis, computer simulation using Pspice and by applying it to an electronic ballast for a prototype 1kW MHL.

Application Method and EMTP-RV Simulation of Series Resonance Type Fault Current Limiter for Smart Grid based Electrical Power Distribution System (스마트 그리드 배전계통을 위한 직렬 공진형 한류기 적용 방법 및 EMTP-RV 시뮬레이션 연구)

  • Yun-Seok Ko;Woo-Cheol Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.19 no.2
    • /
    • pp.361-370
    • /
    • 2024
  • In this paper, a method was studied for applying a series resonant type fault current limiter that can be manufactured at low cost to the smart grid distribution system. First, the impact of the harmonic components of the short-circuit fault current injected into the series resonance circuit of the fault current limiter on the peak value of the transient response was analyzed, and a methodology for determining the steady-state response was studied using percent impedance-based fault current computation method. Next, the effectiveness of the method was verified by applying it to a test distribution line. The test distribution system using the designed current limiter was modeled using EMTP_RV, and a three-phase short-circuit fault was simulated. In the fault simulation results, it was confirmed that the steady-state response of the fault current accurately followed the design target value after applying the fault current limiter. In addition, by comparing the fault current waveform before and after applying the fault current limiter, it was confirmed that the fault current was greatly suppressed, confirming the effect of applying the series resonance type current limiter to the distribution system.

Resonance Characteristics Analysis of Grid-connected Inverter Systems based on Sensitivity Theory

  • Wu, Jian;Han, Wanqin;Chen, Tao;Zhao, Jiaqi;Li, Binbin;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.746-756
    • /
    • 2018
  • Harmonic resonance exists in grid-connected inverter systems. In order to determine the network components that contribute to harmonic resonance and the composition of the resonant circuit, sensitivity theory is applied to the resonance characteristic analysis. Based on the modal analysis, the theory of sensitivity is applied to derive a formula for determining the sensitivities of each network component parameter under a resonance circumstance that reflects the participation of the network component. The solving formula is derived for both parallel harmonic resonance and series harmonic resonance. This formula is adopted to a 4-node grid-connected test system. The analysis results reveal that for a certain frequency, the participation of parallel resonance and series resonance are not the same. Finally, experimental results demonstrate that the solving formula for sensitivity is feasible for grid-connected systems.

The study on the wave-resonance for the bio-KI (생체(生體) 기(氣)의 파동(波動) 공명적(共鳴的)인 연구(硏究) 현황(現況))

  • Kim Gyeong-Cheul;Hong Mi-Suk
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.4 no.1
    • /
    • pp.152-162
    • /
    • 2000
  • The present condition of study on the wave-resonance for the bio-KI is observed. The results are as follows: 1. Tn the wave-resonant stand point, the tendency of studying on KI is showed in the several field all over the world. 2. Because it is originated radionics, the wave-resonant tools of MRA insistenting minute-magnetism-resonance-apparatus need the more severe data in the side of electric circuit. 3. The wave resonance apparatus according to the frequency occurance transmits low-frequency's vibration ratio to the electric stimulating aspect. 4. The wave-water is considered on the application of wave-resonance transcription on the water, and needs the comprehension of torsion-field level.

  • PDF

Study on the quench protective circuit for superconducting MR (MRI용 초전도 마그네트의 퀜치보호회로에 대한 연구)

  • 고락길;배준한;심기덕;권영길;류강식
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.80-83
    • /
    • 2001
  • We studied on effective quench protection method to prevent damage from unexpected quench of superconducting magnet for magnetic resonance imaging. And we suggested quench protection circuit that is combined with several protection techniques. This circuit has the capacity to maintain the symmetric nature of the magnetic field and the active shielding effect and to protect shim coils during a quench.

  • PDF

A Study on the location of Compensation Capacitor and Capacitance in the Concrete Slab Track (콘크리트 슬래브궤도에서 보상 커패시터의 위치 및 전기용량에 대한 연구)

  • Kim, Min-Seok;Lee, Sang-Hyeok;Ko, Jun-Seog;Lee, Jong-Woo;Jo, Su-Ik;Yu, Jin-Young
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.879-891
    • /
    • 2009
  • Impedance of rails is increased by the magnetic coupling between rails and reinforcing bars in the concrete slab track. Currently, the current of track circuit has been compensated by installing the compensation capacitors on track circuit because of increasing the impedance of rails. In case of a rapid transit railway, the compensation capacitors are installed every 20[m] to compensate the current of track circuit in the concrete slab track. Because the interval of one block for a rapid transit railway is as long as 1500[m], the compensation capacitors are installed about the number of 70$\sim$75 on track circuit. However, in case the compensation capacitors are broken over the number of three, it is a problem that the amplitude of current is under standard amplitude of current which is 0.8[A]. In this paper, it was suggested installing a compensation capacitor by using resonance phenomenon on the concrete slab track. We represent the electrical model of track circuit and the four terminal network, calculate the parameters demanded for the electrical model in the concrete slab track. Also, we computed the position and capacitance of the compensation capacitor about 2040[Hz], 2400[Hz], 2760[Hz], 3120[Hz] which currently is the track circuit frequency in the Gyeongbu rapid transit railway and demonstrated the validity of it, using the Matlab and PSpice program.

  • PDF

A study on Source Stability Design Method by Power Integrity Analysis (전원무결성 해석에 의한 PCB 전원안정화 설계기법 연구)

  • Chung, Ki-Hyun;Jang, Young-Jin;Jung, Chang-Won;Kim, Seong-Kweon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.7
    • /
    • pp.753-759
    • /
    • 2014
  • This paper introduces the reduction design technique of the resonance phenomenon of the inner PCB based on power integrity from the analysis about the inner power supply line generating RLC resonance. With the technique, the resonant frequency resulted from the structural characteristics of the PCB can be analyzed and allows to predict and the capacitor for resonance phenomenon reduction can be decided as a decoupling capacitor. From the simulation result, it was confirmed that the PCB's resonance phenomenon reduction design technique should have the reduction effect in the inner motherboard of the industrial controller. This research will be contributed to the improvement of the safety of a PDN (Power Delivery Network) structure in the layout design technique of the PCB.

Design of the self-oscillation UV flash lamp power supply and the characteristic of its operation using self-resonance of the transformer (트랜스포머의 자가 공진(Self-Resonance)특성을 이용한 자가 발진(Self-Oscillation) UV(Ultra Violet) 발생 플래시램프 전원장치설계 및 그 동작 특성)

  • Kim, Shin-Hyo;Cho, Dae-Kweon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.48-55
    • /
    • 2014
  • These Xenon flashlamp power supply for Ultra Violet has converter with high voltage conversion ratio. General model is composed of transformer with high voltage conversion ratio and voltage doubler rectifier circuit. Purpose of power supply leads dielectric breakdown of Xenon flashlamp and passes current rapidly. When passing current, it has to limit current to avoid over-heat, damage of electrode and acceleration of gas oxidation which are cause of performance degradation of lamps. Generally, inductors and resistors, which are called as "Ballast," are used to limit currents. Generally, Transformer has high turn ratio to make high voltages. But we can get high voltages using the transformer with low turn ratio which is driven with self resonance. Also, an advantage of self resonance is to make a circuit simply through impedance of transformer in resonance frequency which filters output voltage. As using an unique impedance of transformer, the circuit does not need other impedance elements like the ballast. So the power supply assures high efficiency of the arc discharge.

An Effective Power/Ground Network Design of VLSI Circuits to Suppress RLC Resonance Effects (공진현상을 감소시키기 위한 효율적인 파워/그라운드 네트워크 디자인)

  • Ryu, Soon-Keol;Eo, Yung-Seon;Shim, Jong-In
    • Proceedings of the IEEK Conference
    • /
    • 2004.06b
    • /
    • pp.435-438
    • /
    • 2004
  • This paper presents a new analytical model to suppress RLC resonance effects in power/ground lines due to a decoupling capacitor. First, the resonance frequency of an RLC circuit which is composed of package inductance. decoupling capacitor, and output drivers is accurately estimated. Next, using the estimated resonance frequency, a suitable decoupling capacitor sire is determined. Then, a novel design methodology to suppress the resonance effects is developed. Finally, its validity is shown by using $0.18 {\mu}m$ process-based-HSPICE simulation.

  • PDF