• Title/Summary/Keyword: Resolution-V

Search Result 928, Processing Time 0.026 seconds

Evaluation of the Degree of the Orthogonality of 2-level Resolution-V Designs Constructed by Balanced Arrays (균형배열에 의해 설계되는 2-수준 Resolution-V 실험법의 직교성 평가측도)

  • Kim, Sang-Ik
    • Communications for Statistical Applications and Methods
    • /
    • v.15 no.2
    • /
    • pp.235-244
    • /
    • 2008
  • Balanced arrays which are generalized orthogonal arrays, introduced by Chakravarti (1956) can be used to construct the fractional factorial designs. Especially for 2-level factorials, balanced arrays with strength 4 are identical to the resolution-V fractional designs. In this paper criteria for evaluation the degree of the orthogonality of balanced arrays of 2-levels with strength 4 are developed and some application methods of the suggested criteria are discussed. As a result, in this paper, we introduce the constructing methods of near orthogonal saturated balanced resolution-V fractional 2-level factorial designs.

Study on the Optimality of 2-level Resolution V Minimal Fractional Factorial Designs (2-수준계 Resolution V 최소 부분실험법의 최적성에 관한 연구)

  • Kim Sang Ik
    • Journal of Korean Society for Quality Management
    • /
    • v.32 no.3
    • /
    • pp.234-243
    • /
    • 2004
  • In this paper, we study the optimality of 2-level resolution V minimal fractional factorial designs which can be constructed by using a partially balanced array. Moreover the relative efficiencies of such designs are compared in the sense of three optimality criteria such as determinant(D)-optimality, trace(A)-optimality, and eigenvalue(E) -optimality criterion.

Development of hand-held coded-aperture gamma ray imaging system based on GAGG(Ce) scintillator coupled with SiPM array

  • Jeong, Manhee;Hammig, Mark
    • Nuclear Engineering and Technology
    • /
    • v.52 no.11
    • /
    • pp.2572-2580
    • /
    • 2020
  • Emerging gamma ray detection applications that utilize neutron-based interrogation result in the prompt emission of high-energy (>2 MeV) gamma-rays. Rapid imaging is enabled by scintillators that possess high density, high atomic number, and excellent energy resolution. In this paper, we evaluate the bright (50,000 photons/MeV) oxide scintillator, cerium-doped Gd2Al2Ga3O12 (GAGG(Ce)). A silicon photomultiplier (SiPM) array is coupled to a GAGG(Ce) scintillator array (12 × 12 pixels) and integrated into a coded-aperture based gamma-ray imaging system. A resistor-based symmetric charge division circuit was used reduce the multiplicity of the analog outputs from 144 to 4. The developed system exhibits 9.1%, 8.3%, and 8.0% FWHM energy resolutions at 511 keV, 662 keV, and 1173.2 keV, respectively. In addition, a pixel-identification resolution of 602 ㎛ FWHM was obtained from the GAGG(Ce) scintillator array.

Optimization of airborne alpha beta detection system modeling using MCNP simulation

  • Sung, Si Hyeong;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.841-845
    • /
    • 2020
  • An airborne alpha beta detection system using passivated implanted planar silicon (PIPS) detector was modeled with the MCNP6 code and its resolution and detection efficiency were analyzed. Simulation of the resolution performed using the Gaussian energy broadening (GEB) function showed that the full width at half maximum (FWHM) of 35.214 keV for alpha particles was within 34-38 KeV, which is the FWHM range of the actual detector, and the FWHM of 15.1 keV for beta particles was constructed with a similar model to 17 keV, which is the FWHM range of an actual detector. In addition, the detection efficiency and the resolution were simulated according to the distance between the detector and the air filter. When the distance was decreased to 0.2 cm from 0.8 cm, the efficiency of the alpha and beta particles detection decreased from 5.33% to 4.89% and from 5.64% to 4.27%, respectively, and the FWHM of the alpha and beta particles improved from 40.9 KeV to 29.84 keV and 25.76 keV-13.27 keV, respectively.

Performance Evaluation of Component Detectors of Double-scattering Compton Camera (이중 산란형 컴프턴 카메라 구성 검출기 성능 평가)

  • Seo, Hee;Park, Jin-Hyung;Kim, Chan-Hyeong;Lee, Ju-Hahn;Lee, Chun-Sik;Lee, Jae-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.2
    • /
    • pp.69-76
    • /
    • 2010
  • Prototype double-scattering Compton camera, which consists of three gamma-ray detectors, that is, two double-sided silicon strip detectors (DSSDs) as scatterer detectors and a NaI(Tl) scintillation detector as an absorber detector, could provide high imaging resolution with a compact system. In the present study, the energy resolution and the timing resolution of component detectors were measured, and the parameters affecting the energy resolution of the DSSD were examined in terms of equivalent noise charge (ENC). The energy resolutions of the DSSD-1 and DSSD-2 were, in average, $25.2keV{\pm}0.8keV$ FWHM and $31.8keV{\pm}4.6keV$ FWHM at the 59.5 keV peak of $^{241}Am$, respectively. The timing resolutions of the DSSD and NaI(Tl) scintillation detector were 57.25 ns FWHM and 7.98 ns FWHM, respectively. In addition, the Compton image was obtained for a point-like $^{137}Cs$ gamma source with double-scattering Compton camera. From the present experiment, the imaging resolution of 8.4 mm FWHM (angular resolution of $8.1^{\circ}$ FWHM), and the imaging sensitivity of $1.5{\times}10^{-7}$ (intrinsic efficiency of $1.9{\times}10^{-6}$) were obtained.

A Study on the Determination of Experimental Size of Near-orthogonal Two-level Balanced Trace Optimal Resolution-V Fractional Factorial Designs (직교성에 가까운 트레이스 최적 2-수준 Resolution-V 균형 일부실험법의 실험크기 결정에 관한 연구)

  • Kim, Sang Ik
    • Journal of Korean Society for Quality Management
    • /
    • v.45 no.4
    • /
    • pp.889-902
    • /
    • 2017
  • Purpose: The orthogonality and trace optimal properties are desirable for constructing designs of experiments. This article focuses on the determination of the sizes of experiments for the balanced trace optimal resolution-V fractional factorial designs for 2-level factorial designs, which have near-orthogonal properties. Methods: In this paper, first we introduce the trace optimal $2^t$ fractional factorial designs for $4{\leq}t{\leq}7$, by exploiting the partially balanced array for various cases of experimental sizes. Moreover some orthogonality criteria are also suggested with which the degree of the orthogonality of the designs can be evaluated. And we appraise the orthogonal properties of the introduced designs from various aspects. Results: We evaluate the orthogonal properties for the various experimental sizes of the balanced trace optimal resolution-V fractional factorial designs of the 2-level factorials in which each factor has two levels. And the near-orthogonal 2-level balanced trace optimal resolution-V fractional factorial designs are suggested, which have adequate sizes of experiments. Conclusion: We can construct the trace optimal $2^t$ fractional factorial designs for $4{\leq}t{\leq}7$ by exploiting the results suggested in this paper, which have near-orthogonal property and appropriate experimental sizes. The suggested designs can be employed usefully especially when we intend to analyze both the main effects and two factor interactions of the 2-level factorial experiments.

An Improved Proton Recoil Telescope Detector for Fast Neutron Spectroscopy

  • Chung, Moon-Kyu;Kang, Hee-Dong;Park, Tong-Soo
    • Nuclear Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.191-201
    • /
    • 1973
  • For fast neutron spectroscopy in MeV region, a recoil proton telescope detector was designed and constructed so as to increase in detection efficiency without appreciable deterioration in energy resolution by adopting a special type of recoil proton radiator which is a combination of a ring-shaped vertical radiator and a cone-shaped horizontal radiator at a certain geometry. A neutron stopper was built in the detector system to minimize the background due to direct exposure of the Si(Li) detectors to primary incident neutrons. The detection efficiency and the energy resolution calculated at various neutron energies and geometries are given and these characteristics of the detector system were tested by 14.1 MeV neutrons. As the calculation predicted, the relative detection efficiency in case of the combined radiator system is almost 2.2 times of that for a single, ring-shaped vertical radiator system. The calculated energy resolution is 3.7% FWHM, whereas the measured resolution was 3.9% which means resolution broadening of approximately. 30% was resulted by introducing a combined radiator system into the telescope. Increase in background less than 40% was also observed.

  • PDF

Evaluating the Comfort Experience of a Head-Mounted Display with the Delphi Methodology

  • Lee, Doyeon;Chang, Byeng-hee;Park, Jiseob
    • Journal of Internet Computing and Services
    • /
    • v.21 no.6
    • /
    • pp.81-94
    • /
    • 2020
  • This study developed evaluation indicators for the comfort experience of virtual reality (VR) headsets by classifying, defining, and weighting cybersickness-causing factors using the Delphi research method and analytic hierarchical process (AHP) approach. Four surveys were conducted with 20 experts on VR motion sickness. The expert surveys involved the 1) classification and definition of cybersickness-causing dimensions, classification of sub-factors for each dimension, and selection of evaluation indicators, 2) self-reassessment of the results of each step, 3) validity revaluation, and 4) final weighting calculation. Based on the surveys, the evaluation indicators for the comfort experience of VR headsets were classified into eight sub-factors: field of view (FoV)-device FoV, latency-device latency, framerate-device framerate, V-sync-device V-sync, rig-camera angle view, rig-no-parallax point, resolution-device resolution, and resolution-pixels per inch (PPI). A total of six dimensions and eight sub-factors were identified; sub-factor-based evaluation indicators were also developed.

OPTICAL INVESTIGATION OF THE CRAB PULSAR: SIMULTANEOUS UBVR LIGHT CURVES WITH TIME RESOLUTION OF 3.3 ${\mu}s$ AND SPECTROSCOPY

  • KOMAROVA V. N.;BESKIN G. M.;NEUSTROEV V. V.;PLOKHOTNICHENKO V. L.
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.217-218
    • /
    • 1996
  • The results of the Crab pulsar observations with the photometrical MANIA (Multichannel Analysis of Nanosecond Intensity Alterations) complex at the 6-m telescope are presented. More than 12 millions photons in UBVR-bands simultaneously with time resolution of $10^{-7}s$ were detected. Using the original software for search for optical pulsar period, we obtained the light curves of the object with time resolution of about 3.3 ${\mu}s$. Their detailed analysis gives the spectral change during pulse and subpulse, the shape of the pulse peaks, which are plateaus (with the duration of about 50${\mu}s$ for the main pulse), limits for an amplitude of fine temporal (stochastic and regular) structure of pulse and sub pulse and the interpulse space intensity. The results of CCD-spectroscopy of the Crab pulsar show that its summarized spectrum is flat. There are no lines, neither emission nor absorbtion ones. Upper limit for line intensity or depth is $3.5\%$ with the confidence probability of $95\%$.

  • PDF

Partially Balanced Resolution IV' Designs in a 2^m-Factorial

  • Paik, U.B.
    • Journal of the Korean Statistical Society
    • /
    • v.11 no.1
    • /
    • pp.1-11
    • /
    • 1982
  • Srivastava and Anderson(1970) illustrate a method of obtaining Balanced (but not orthogonal) Resolution $IV^*$ designs starting with a BIB design. The incidence matrix of a BIB design with parameters (v, b, r, k, and $\lambda$) is utilized to obtain Balanced Resolution $IV^*$ designs with m factors and n=2b runs, where $m \leq v$. In this paper, the same idea is extended to the case of PBIB designs to obtain Partially Balanced Resolution $IV^*$ designs. In the designs obtained here the variances are balanced and the covariances are partially balanced with respect to the main effects. A proof of this property of Partially Balanced Resoultion $IV^*$ designs is given. The efficiency of Partially Balanced Resolution $IV^*$ designs is also considered and examples of Partially Balanced Resoultion $IV^*$ designs are included.

  • PDF