• Title/Summary/Keyword: Resolution rate

Search Result 1,150, Processing Time 0.028 seconds

The Clinical Characteristics of Infantile Primary Vesicoureteral Reflux and Its Spontaneous Resolution Rate (영아기 일차성 방광요관역류의 임상적 특성과 자연 소실율)

  • Choi, Youn-Sung;Kim, Ji-Hye;Shim, Yoon-Hee;Lee, Seung-Joo
    • Childhood Kidney Diseases
    • /
    • v.11 no.1
    • /
    • pp.83-91
    • /
    • 2007
  • Purpose : Childhood primary VUR is generally diagnosed after urinary tract infection, is more prevalent among girls and has a low spontaneous resolution rate in cases of severe VUR. The aim of the present study is to examine the age and gender-related characteristics and the spontaneous resolution rate of infantile primary VUR. Methods : The medical records of 96 infants with primary VUR, diagnosed after their first UTI, were retrospectively reviewed(1995-2004). The clinical characteristics including gender, the degree of VUR and presence of renal scars were evaluated. The spontaneous resolution rate and contributing factors were also analyzed Results : Infantile primary VUR was more prevalent in males than females. The percentage of atrophic scarred kidney was significantly higher in males than females(17.2% vs 3.4%) (P<0.05). The cumulative spontaneous resolution rate in 3 years was very high(89.1%), and was not significantly different between gender and among VUR grades. But in the first year, the spontaneous resolution rate of severe refluxing ureters was significantly higher in males than in females(46.2% vs 7.1%)(P<0.05) and the spontaneous resolution rate of refluxing ureters with no scarred kidneys was significantly higher than those associated with atrophic scarred kidneys(76.6% vs 20%)(P<0.05). Conclusion : Infantile Primary VUR was more prevalent among males and tends to be associated with atrophic scarred kidneys In male infants. The cumulative spontaneous resolution rate in 3 years was very high, even in high-grade VUR and associated atrophic scarred kidneys. In infantile primary VUR, surgery should be withheld even in infants with high-grade VUR with atrophic scarred kidneys.

  • PDF

Development of Solenoid RF coil for 4.7 T Magnetic Resonance Velocimeter to Improve Resolution (해상도 향상을 위한 4.7 T 자기공명유속계 용 솔레노이드 RF 코일 개발)

  • Yang, Byungkuen;Cho, Jee-Hyun;Song, Simon
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.2
    • /
    • pp.40-45
    • /
    • 2016
  • Magnetic resonance velocimeter (MRV) is a powerful tool to non-invasively measure the velocity of a fluid flow in various fields ranging from medicine to engineering. However, since the demands for accurate measurement in the solid/liquid interface for cardiovascular diseases and porous media increase, the improvement of spatial resolution is required. In this study, a solenoid RF coil is developed for high spatial resolution measurement. The signal-to-noise ratio in solenoid RF coil is increased seventeen times better than that in commercial coil. Moreover, the velocity distribution of Hagen-Poiseuille flow is measured with in-plane resolution of $36{\mu}m$ by $36{\mu}m$ and the accuracy of the measured velocity is compared with theoretical distribution of the laminar flow. Flow rate calculated by MRV is estimated with the flow rate injected by syringe pump.

Measurement of Sub-micrometer Features Based on The Topographic Contrast Using Reflection Confocal Microscopy

  • Lee SeungWoo;Kang DongKyun;Yoo HongKi;Kim TaeJoong;Gweon Dae-Gab;Lee Suk-Won;Kim Kwang-Soo
    • Journal of the Optical Society of Korea
    • /
    • v.9 no.1
    • /
    • pp.26-31
    • /
    • 2005
  • We describe the design and the implementation of video-rate reflection confocal scanning microscopy (CSM) using an acousto-optical deflector (AOD) for the fast horizontal scan and a galvanometer mirror (GM) for the slow vertical scan. Design parameters of the optical system are determined for optimal resolution and contrast. The OSLO simulations show that the performances of CSM are not changed with deflection angle and the wavefront errors of the system are less than 0.012λ. To evaluate the performances of designed CSM, we do a series of tests, measuring lateral and axial resolution, real time image acquisition. Due to a higher axial resolution compared with conventional microscopy, CSM can detect the surface of sub-micrometer features. We detect 138㎚ line shape pattern with a video-rate (30 frm/sec). And 10㎚ axial resolution is archived. The lateral resolution of the topographic images will be further enhanced by differential confocal microscopy (DCM) method and computational algorithms.

Adaptive Control for the Conventional Mode of Operation of MEMS Gyroscopes

  • Park, Sungsu;Roberto Horowitz
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.39.2-39
    • /
    • 2002
  • This paper presents adaptive add-on control algorithms for theconventional mode of operation of MEMS z-axis gyroscopes. This scheme is realized by adding an outer loop to a conventional force-balancing scheme that includes a parameter estimation algorithm. The parameter adaptation algorithm estimates the angular rate, identifies and compensates the quadrature error, and may permit on-line automatic mode tuning. The convergence and resolution analysis show that the proposed adaptive add-on control scheme prevents the angular rate estimate from being contaminated by the quadrature error, while keeping ideal resolution performance of a conventional force-balancing scheme.

  • PDF

Iris Recognition using Multi-Resolution Frequency Analysis and Levenberg-Marquardt Back-Propagation

  • Jeong Yu-Jeong;Choi Gwang-Mi
    • Journal of information and communication convergence engineering
    • /
    • v.2 no.3
    • /
    • pp.177-181
    • /
    • 2004
  • In this paper, we suggest an Iris recognition system with an excellent recognition rate and confidence as an alternative biometric recognition technique that solves the limit in an existing individual discrimination. For its implementation, we extracted coefficients feature values with the wavelet transformation mainly used in the signal processing, and we used neural network to see a recognition rate. However, Scale Conjugate Gradient of nonlinear optimum method mainly used in neural network is not suitable to solve the optimum problem for its slow velocity of convergence. So we intended to enhance the recognition rate by using Levenberg-Marquardt Back-propagation which supplements existing Scale Conjugate Gradient for an implementation of the iris recognition system. We improved convergence velocity, efficiency, and stability by changing properly the size according to both convergence rate of solution and variation rate of variable vector with the implementation of an applied algorithm.

A Study on High Resolution Reconstruction Algorithms for improving Resolution (해상도 향상을 위한 고해상도 복원 알고리즘 연구)

  • Baek, Young-Hyun;Moon, Sung-Ryong
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.1
    • /
    • pp.72-79
    • /
    • 2007
  • In this paper, It propose a new restoration algorithm of high resolution, which is reconstructed to high resolution image using low resolution image informations. The proposed algorithm is constructed based on super resolution theory, it is consisted of progressive steps of the integration and construction. It reduced a lot of data-processing capacity and noise with integration through sub-pixel movement and wavelet basis through a higher resolution. As a result, it is shown that the main information is maintained and the error rate is improved. Using expansion fuzzy wavelet B-spline interpolation in stage of construction, it is confirmed that we can achieve smoothing image and good resolution without blur and block.

The Image Resolution Compare to Having Lead Plate or Not Lumbar Lateral Projection

  • Kim, Hyun-Soo;Min, Jung-Whan;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.4
    • /
    • pp.145-151
    • /
    • 2011
  • The purpose of this study is to know some changes of resolution and image if we remove scattered ray using lead plate when doing lumbar lateral projection. Using 3 DR system(2 FD types, 1 CCD type) equipments and 2 film system equipments, we gain the image whether the phantom of abdomen equivalent sticking resolution chart has lead plate or not, whether we do collimation or not. Also, we use ion chamber, measure radiation exposure rate and change to entrance surface dose from it. we gain that images in the greatest condition of taking in clinic. 5 people in this group decoded resolution with our eyes, measured thickness of images and compared them from each equiments. Resolution has difference to size of collimation in DR FD type. Also there is no difference the original image with the new image which we abbreviated mAs. In DR CCD type, resolution didn't have difference whether lead plate is or not and whether we do collimation or not. In film type, existing or nonexisting of lead plate didn't influence on resolution. Lead plate makes the quality of image higher due to reducing scattered ray, it doesn't influence on resolution.

  • PDF

A Video Encoding Scheme using Adaptive Spatial Resolution Control for Mobile Video Applications (모바일 비디오 응용을 위한 적응적 공간 해상도 제어 인코딩 기법)

  • Lee, Hee-Jung;Lee, Yong-Hee;Lee, Jong-Hun;Shin, Heon-Shik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.7C
    • /
    • pp.654-662
    • /
    • 2009
  • Video streams for mobile video streaming can be encoded to fit the available network bandwidth by controlling three factors: temporal resolution, spatial resolution, and picture quality. The controlling of picture quality by modifying the quantization parameter (QP) is most widely used. In this paper, we demonstrate that reducing the spatial resolution adaptively can be more efficient in terms of picture quality and energy consumption in low bit-rate environment, and present a model to find the optimal spatial resolution for the available bandwidth. Adaptive spatial resolution control scheme is especially effective when the bandwidth between the video server and the mobile device varies considerably with time, and when the mobile device is sensitive to energy consumption. Our scheme can improve the picture quality by approximately O.5dB and reduce energy consumption by more than 50% compared to the conventional video coding in low bit-rate environment.

Fractal Image Compression Based on Wavelet Transform Domain Using Significant Coefficient Tree (웨이브렛 변환 영역에서의 유효계수 트리를 이용한 프랙탈 영상 압축 방법)

  • 배성호;박길흠
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.11
    • /
    • pp.62-71
    • /
    • 1996
  • In this paper we propose a method that improves PSNR at low bit rate and reduces computational complexity in fractal image coding based on discrete wavelet transform. The proposed method, which uses significant coefficient tree, improves PSNR of the reconstructed image and reduces computational comlexity of mapping domain block onto range block by matching only the significant coefficients of range block to coefficients of domain block. Also, the proposed method reduces error propagation form lower resolution subbands to higher resolution subbands by correcting error of lower resolution subbands. Some experimental results confirm that the proposed method reduces encoding and decoding time significantly and has fine reconstructed images having no blocking effect and clear edges at low bit rate.

  • PDF

High Speed, High Resolution CMOS Sample and Hold Circuit (고속, 고해상도 CMOS 샘플 앤 홀드 회로)

  • Kim Won-Youn;Park Kong-Soon;Park Sang-Wook;Yoon Kwang-Sub
    • Proceedings of the IEEK Conference
    • /
    • 2004.06b
    • /
    • pp.545-548
    • /
    • 2004
  • The paper describes the design of high-speed, high-resolution Sample-and-Hold circuit which shows the conversion rate 80MHz and the power supply of 3.3v with 0.35um CMOS 2-poly 4-metal process for high-speed, high resolution Analog-to-Digital Converter. For improving Dynamic performance of Sample-and-Hold, Two Double bootstrap switch and high performance operational amplifier with gain booster, which are used. and For physical stability of Sample and Hold circuit, reduces excess voltage of gate in bootstrap switch. Simulation results using HSPICE shows the SFDR of 71dB, 75dB in conversion rate of 80MHz result for two inputs(0.5Vpp, 10MHz and 1Vpp, 10MHz) and the power dissipation of 48mW at single 3.3V supply voltage.

  • PDF