• 제목/요약/키워드: Resistivity

검색결과 4,027건 처리시간 0.028초

Response of coal rock apparent resistivity to hydraulic fracturing process

  • Song, Dazhao;Wang, Enyuan;Qiu, Liming;Jia, Haishan;Chen, Peng;Wei, Menghan
    • Geomechanics and Engineering
    • /
    • 제14권6호
    • /
    • pp.581-588
    • /
    • 2018
  • In order to explore the comprehensive evaluation means of the extent of hydraulic fracturing region in coal seams, we analyzed the feasibility of detecting the response of coal rock direct current (DC) apparent resistivity to hydraulic-fracturing using Archie's theory, and conducted experimental researches on the response of DC resistivity in the hydraulic fracturing process using small-scale coal rock samples. The results show that porosity and water saturation are the two factors affecting the apparent resistivity of coal rock while hydraulic fracturing. Water has a dominant effect on the apparent resistivity of coal rock samples. The apparent resistivity in the area where water flows through is reduced more than 50%, which can be considered as a core affect region of hydraulic fracturing. Stress indirectly impacts the apparent resistivity by changing porosity. Before hydraulic fracturing, the greater axial load applied, the more serious the rupture in the samples, resulting in the greater apparent resistivity. Apparent resistivity testing is a potential regional method to evaluate the influence range of hydraulic fracturing in coal seams.

2층 대지모델에서 대지저항률의 비율에 따른 접촉전류에 의한 감전의 위험성 분석 (Analysis of Electric Shock Hazards due to Touch Current According to Soil Resistivity Ratio in Two-layer Earth Model)

  • 이복희;김태기;조용승;최종혁
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.68-74
    • /
    • 2011
  • The touch or step voltages which exist in the vicinity of a grounding electrode are closely related to the earth structure and resistivity and the ground current. The grounding design approach is required to determine the grounding electrode location where the hazardous voltages are minimized. In this paper, in order to propose a method of mitigating the electric shock hazards caused by the ground surface potential rise in the vicinity of a counterpoise, the hazards relevant to touch voltage were evaluated as a function of the soil resistivity ratio $\rho_2/\rho_1$ for several practical values of two-layer earth structures. The touch voltage and current on the ground surface just above the test electrode are calculated with CDEGS program. As a consequence, it was found that burying a grounding electrode in the soil with low resistivity is effective to reduce the electric shock hazards. In the case that the bottom layer soil where a counterpoise is buried has lower resistivity than the upper layer soil, when the upper layer soil resistivity is increased, the surface potential is slightly raised, but the current through the human body is reduced with increasing the upper layer soil resistivity because of the greater contact resistance between the earth surface and the feet. The electric shock hazard in the vicinity of grounding electrodes is closely related to soil structure and resistivity and are reduced with increasing the ration of the upper layer resistivity to the bottom layer resistivity in two-layer soil.

코어비저항 측정에 미치는 영향요소에 대한 실험적 고찰(Ⅱ) - 시계열자료의 특성과 대표비저항 값의 결정 (Experimental Verification on Factors Affecting Core Resistivity Measurements (II)-Characteristics of Time Series Data and Determination Method of Resistivity)

  • 김영화;최예권
    • 지구물리
    • /
    • 제2권4호
    • /
    • pp.269-276
    • /
    • 1999
  • 암석의 코어비저항 값을 올바르게 결정하기 위한 노력의 일환으로 비저항 측정에 있어서 샘플홀더의 영향을 분석하고 시계열자료로부터 암석의 비저항을 대표할 수 있는 비저항 값을 효과적으로 구하는 방안에 관하여 연구하였다. 샘플홀더에 대한 연구로는 기존의 GS식과 2전극식 방법과 함께 코어시료 표면을 전도성 접착제로 처리한 변형 GS식 및 변형 2전극식을 고안하여 각 특성을 비교하였으며 그 중에서 변형 2전극식이 측정자료의 안정성과 측정의 편이성 측면에서 장점이 있는 것으로 확인되었다. 샘플홀더 및 사용 소스 주파수의 차이에 따라 달리 나타나는 시계열자료의 분포특성에 관한 분석 결과는 최대곡률점을 이용하여 암석의 대표비저항을 결정하는 방법이 효과적임을 보이고 있다.

  • PDF

새로운 트랜치 방법을 이용한 저저항 실리콘 기판에서의 High Q 인덕터의 구현 (Realization of High Q Inductor on Low Resistivity Silicon Wafer using a New and simple Trench Technique)

  • 이홍수;이진효유현규김대용
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.629-632
    • /
    • 1998
  • This paper presents a new and simple technique to realize high Q inductor on low resistivity silicon wafer with 6 $\Omega$.cm. This technique is very compatible with bipolar and CMOS standard silicon process. By forming the deep and narrow trenches on the low resistivity wafer substrate under inductor pattern, oxidizing and filling with undoped polysilicon, the low resistivity silicon wafer acts as high resistivity wafer being suitable for the fabrication of high Q inductor. By using this technique the quality factor (Q) for 8-turn spiral inductor was improved up to max. 10.3 at 2 ㎓ with 3.0 $\mu\textrm{m}$ of metal thickness. The experiment results show that Q on low resistivity silicon wafer with the trench technique have been improved more than 2 times compared to the conventional low resistivity silicon wafer without trenches.

  • PDF

오염토양의 전기 비저항치 변화 연구 (Electrical Resistivity Variations of Contaminated Soils)

  • 윤길림;이용길
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2000년도 창립총회 및 춘계학술발표회
    • /
    • pp.84-89
    • /
    • 2000
  • Parametric studies based on laboratory pilot tests were performed to investigate the relationships between electrical resistivity and contaminated soil properties. Three kinds of sandy soils sampled and leachates from a industrial waste landfill were mixed to model the contaminated soils. Electrical resistivity of soils were measured by using a simulated resistivity cone penetrometer probe. In the experiments, the electrical resistivity were observed with changing the water content, void ratio, unit weight, degree of saturation, and concentration of the leachate. The test results show that the electrical resistivity of soils depends largely on the water content and the electrical property of pore water rather than unit weight and types of soils.

  • PDF

PE 및 PP혼합 재료의 표면저항에 미치는 습도효과 (Humidity effects on surface resistivities in PE and PP mixtures)

  • 강전홍;유황민;김한준;한상옥;김종석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.424-426
    • /
    • 2002
  • The surface and volume resistivity in the polymers, PE(polyethylene) and PP(polypropylene) mixtures are tested and measured by the ASTM D257(KS M3015) standard. Humidity effects on surface and volume resistivity in two polymers have been studied qualitatively at room temperature. The results of resistivity in these polymers show that the values of surface resistivity (and volume resistivity) at the humidity of 90% are remarkably small compared with those at the humidity of 50%, independing on applied voltage. When we varied the humidity in two polymers, it was found to takes many hours to recover into original surface resistivity (and volume resistivity) of these polymers.

  • PDF

Application of resistivity monitoring to examine the grouting effect

  • Farooq, Muhammad;Park, Sam-Gyu;Kim, Jung-Ho;Song, Young-Soo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2006년도 공동학술대회 논문집
    • /
    • pp.79-82
    • /
    • 2006
  • This paper presents to examine the ability of an electrical resistivity method to monitor the grouting effect at subsidence area. To monitor the changes in ground resistivity before and during the grout, series of electrical resistivity monitoring surveys have been conducted. Data has acquired in the form of grid making nine lines parallel to road and four lines traverse the road. Two kinds of electrode arrays modify pole-pole and dipole-dipole arrays were used during resistivity data acquisition. In this paper, the results show that electrical prospecting is an effective method to detect low resistivity imaging zone by grout during the ground reinforcement.

  • PDF

체적함수비 및 주파수에 따른 풍화토의 전기비저항 특성 (Characteristic of electrical resistivity against volumetric water content and frequency in weathered soil)

  • 손영환;봉태호;장병욱
    • 한국농공학회논문집
    • /
    • 제50권5호
    • /
    • pp.63-72
    • /
    • 2008
  • This study was conducted to define a characteristics of Electrical Resistivity of weathered soil against volumetric water content and frequency. It is essential to analyze and understand a characteristics of the Electrical Resistivity for evaluation of soil as subsurface contaminant detection. Before the test, an effect of pore water and ion were checked using four liquids(distilled water, tap water, potassium chloride 1.8mM, and 3.7mM). As a result, the correlation between the volumetric water content and the Electrical Resistivity was estimated. The Electrical Resistivity decreases with increasing frequency and water content. Also, Electrical Resistivity could be described by an exponential function of volumetric water content with the constants.

A Fast Calculation of Apparent Soil Resistivity Using Exponential Sampling Method

  • Kang, Min-Jae;Kim, Ho-Chan
    • International Journal of Advanced Culture Technology
    • /
    • 제7권4호
    • /
    • pp.268-273
    • /
    • 2019
  • The apparent soil resistivity is used for estimating multilayer soil parameters, such as, layer's depth and soil resistivity. The soil parameters are estimated by continuously revising those parameters until the error between the measured and calculated apparent soil resistivity reaches to allowable level. The equation for calculating the apparent soil resistivity is complicated and time consumed, because it is composed of an infinite integral which includes a zero order Bessel's function of the first kind. In this paper, a fast algorithm for calculating the apparent soil resistivity of horizontal multilayer earth structure is proposed using exponential sampling method.

전기비저항 측정에서 실험체 크기의 영향에 대한 실험적 연구 (Experimental Study on the Effect of Specimen Size on Electrical Resistivity Measurement)

  • 임영철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권6호
    • /
    • pp.164-169
    • /
    • 2018
  • 본 연구에서는 전기비저항에 대한 실험실 레벨의 측정에서 실험체 크기가 겉보기 비저항에 미치는 영향에 대해 검토하였다. 실험은 실험체의 측변과 높이가 다른 실험체를 제작하여 겉보기 비저항을 측정하였다. 실험결과, 실험체의 측변과 높이이 작을수록 겉보기 비저항이 크게 나타났다. 또한 전기비저항 측정에 미치는 실험체 크기의 영향은 선형적으로 나타나지 않음을 확인하였다.