• Title/Summary/Keyword: Resistive Load

Search Result 108, Processing Time 0.026 seconds

Gate Driver for Power Cell Driving of Bipolar Pulsed Power Modulator (양극성 펄스 파워 모듈레이터의 파워셀 구동을 위한 게이트 드라이버)

  • Song, Seung-Ho;Lee, Seung-Hee;Ryoo, Hong-Je
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.2
    • /
    • pp.87-93
    • /
    • 2020
  • This study proposes a gate driver that operates semiconductor switches in the bipolar pulsed power modulator. The proposed gate driver was designed to receive isolated power and synchronized signals through the gate transformer. The gate circuit has a separate delay in the on-and-off operation to prevent a short circuit between the top and bottom switches of each leg. On the basis of the proposed gate circuit, a bipolar pulsed power modulator prototype with a 2.5 kV/100 A rating was developed. Finally, the bipolar pulsed power modulator was tested under resistive load and plasma reactor load conditions. It is verified that the proposed gate driver can be applied to a bipolar pulsed power modulator.

Analysis of Operating Characteristic of Self Excited Induction Generator with Steinmetz Connection (스타인메츠결선 자기여자 유도발전기의 운전특성 분석)

  • Kang, Sang-Su;Jwa, Chong-Keun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.383-387
    • /
    • 2008
  • This paper analyzes the operation characteristics of a self excited induction generator with Steinmetz connection. For this analysis, the symmetrical components analysis is used to obtain the related expressions and the excitation capacitance and the magnetizing reactance are determined in turn by the condition of self excitation which includes the input impedance of the generator as viewed across load terminals. Two simultaneous equations of the condition of self excitation itself are solved by using the real and imaginary function in an application software. This method is applied to simulate the operation characteristics when the generator is driven at rated speed and the specified excitation capacitor is connected across the lagging phase. The results show that better operation characteristics except generated frequency are obtained by using relatively large excitation capacitance and resistive load.

Power Flow Control at the Subnetwork-Level in Microgrids

  • Liu, Kun;Khan, Muhammad Mansoor;Rana, Ahmad;Fei, Dong
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.588-603
    • /
    • 2018
  • This paper presents the idea of a smart load that can adjust the input power flow based on the intermittent power available from RESs (Renewable Energy Resources) to regulate the line voltage, and draw a constant power from the grid. To this effect, an innovative power flow controller is presented based on a Resistive ES (Electric Spring) in combination with a PEAT (Power Electronics based Adjustable Transformer), which can effectively shape the load power flow at the subnetwork level. With a PEAT incorporated in the step down transformer at the grid side, the proposed controller can supply non-critical loads through local RESs, and the critical loads can draw a relatively constant power from the grid. If there is an abundance of power produced by the RESs, the controller can supply both non-critical loads and critical loads through the RES, which significantly reduces the power demand from the grid. The principle, practicality, stability analysis, and controller design are presented. In addition, simulation results show that the power flow controller performs well in shaping the load power flow at the subnetwork level, which decreases the power demand on the grid. Experimental results are also provided to show that the controller can be realized.

Voltage Amplitude Control of Square-Wave VSIs with an R-L Load (R-L부하를 가진 구형파 VSI의 전압크기 제어)

  • Kim Kyung-Won;Hong Soon-Chan;Yoo Jong-Gul;Kim Sang-Kyun;Park Chae-Woon
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.479-482
    • /
    • 2001
  • This paper proposes a modified $\alpha$ conduction mode for controlling the output voltage magnitude of three-phase square-wave VSIs with an R-L load. From the viewpoint of both power capacity and switching losses, three-phase square-wave inverters are now used in most high power systems. When the square-wave VSI is driven with $\alpha$ conduction mode to control the magnitude of output voltages, interval over than half period is operated with $180^{\circ}$ conduction mode and the other interval with $120^{\circ}$ conduction mode. In $120^{\circ}$ conduction mode operation, two output terminals are connected to DC supply and the third one remains open. The potential of this open terminal will depend on the load characteristics and is unpredictable except the case of pure resistive loads. To cope this problem, we propose the modified α conduction mode.

  • PDF

Power Cell-based Pulsed Power Modulator with Fast Rise Times (빠른 상승 시간을 갖는 파워 셀 기반 펄스 파워 모듈레이터)

  • Lee, Seung-Hee;Song, Seung-Ho;Ryoo, Hong-Je
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.1
    • /
    • pp.25-31
    • /
    • 2021
  • This paper describes the design of a power cell-based pulsed power modulator with fast rise times. The pulse-generating section of the pulse power modulator is a series stack of power cells. Each power cell is composed of a storage capacitor, a pulse switch, and a bypass diode. When the pulse switches are turned on, the capacitors are connected in series and the sum of voltages is applied to the load. For output pulses with fast rise times, an IGBT with fast turn-on characteristics is adopted as a pulse switch and the optimized gate driving method is used. Pspice simulation is performed to account for the gate driving method. A 10 kV, 12-power cell-based pulsed power modulator is tested under resistive load and plasma reactor load. The rise times of output pulses less than 20 ns are confirmed, showing that the pulsed power modulator can be effectively applied to pulsed power applications with fast rise times.

PERFORMANCE AND DESIGN OF A SINGLE-PHASE LINEAR SYNCHRONOUS GENERATOR USING FINITE ELEMENT METHOD

  • Eid, Ahmad M.;Kim, Sung-Jun;Kang, Ju-Sung;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.95-99
    • /
    • 2005
  • This paper presents a general proposal to design and calculate the performance of a tubular permanent magnet linear generator treated here on the basis of the Finite Element Method. Optimizing the linear generator dimensions reduces the cogging force, which occurs due to the interaction between stator teeth and the permanent magnets. The generated AC voltage is analyzed and evaluated for both no load and load cases to take the armature reaction effects on the air gap flux density. A repetitive routine is followed to calculate the output AC voltage from the change of flux and the speed of the single-phase linear generator. The AC output voltage is calculated for different resistive loads, and hence, the linear generator load characteristic is obtained. The designed linear generator is capable to generate an output power of 5.3kW with AC output voltage of 222V with an efficiency of 96.8% at full load of 23.8A. The full load current is chosen based on the thermal properties of the coil wire insulations.

  • PDF

Design and Performance Analysis of Axial-Flux Permanent-Magnet Generator for Wind Energy System Applications (횡자속형 영구자석 풍력발전기 설계 및 특성해석)

  • Hwang, Don-Ha;Kang, Do-Hyun;Kim, Yong-Joo;Bae, Sung-Woo;Choi, Kyeong-Ho;Kim, Dong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.949-951
    • /
    • 2002
  • Permanent-magnet (PM) synchronous generator is feasible for use with a wind turbine, because the generator for wind power requires variable-speed generation, light weight, and high torque. In this paper, basic design and construction of an axial-flux permanentmagnet generator with power output at 60 [Hz], 300 [r/min] for wind energy system is introduced. Finite-element method (FEM) is applied to analyze generator performance. In order to save time, equivalent analysis model is developed. The performance of the proposed generator at no-load and resistive load are compared, and power output and voltage at various speed and loads are compared as well. The results of FE analysis show that this PM generator is a useful solution for small-scale wind-turbine applications.

  • PDF

Current Limiting and Voltage Sag Suppressing Characteristics of Flux-lock Type SFCL According to Variations of Turn Number's Ratio (자속구속형 초전도전류제한기의 권선비 변화에 따른 전류제한 및 전압강하 보상 특성)

  • Han, Tae-Hee;Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.5
    • /
    • pp.410-415
    • /
    • 2011
  • In this paper, we investigated the fault current limiting and the load voltage sag suppressing characteristics of the flux-lock type SFCL, designed with the additive polarity winding, according to the variations of turn number's ratio and the comparative analysis between the resistive type and the flux-lock type SFCLs were performed as well. From the analysis for the short-circuit tests, the flux-lock type SFCL designed with the larger turn number's ratio was shown to perform more effective fault current limiting and load voltage sag suppressing operations compared to the flux-lock type SFCL designed with the lower turn number's ratio through the fast quench occurrence of the high-$T_C$ superconducting (HTSC) element comprising the flux-lock type SFCL. In addition, the recovery time of the flux-lock type SFCL after the fault removed could be confirmed to be shorter in case of the flux-lock type SFCL designed with the lower turn number ratio.

A Study on a Radar Absorbing Structure for Aircraft Leading Edge Application

  • Baek, Sang Min;Lee, Won Jun;Joo, Young Sik
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.2
    • /
    • pp.215-221
    • /
    • 2017
  • An electromagnetic (EM) wave absorber reduces the possibility of radar detection by minimizing the radar cross section (RCS) of structures. In this study, a radar absorbing structure (RAS) was applied to the leading edge of a blended wing body aircraft to reduce RCS in X-band (8.2~12.4GHz) radar. The RAS was composed of a periodic pattern resistive sheet with conductive lossy material and glass-fiber/epoxy composite as a spacer. The applied RAS is a multifunctional composite structure which has both electromagnetic (EM) wave absorbing ability and load-bearing ability. A two dimensional unit absorber was designed first in a flat-plate shape, and then the fabricated leading edge structure incorporating the above RAS was investigated, using simulated and free-space measured reflection loss data from the flat-plate absorber. The leading edge was implemented on the aircraft, and its RCS was measured with respect to various azimuth angles in both polarizations (VV and HH). The RCS reduction effect of the RAS was evaluated in comparison with a leading edge of carbon fabric reinforced plastics (CFRP). The designed leading edge structure was examined through static structural analysis for various aircraft load cases to check structural integrity in terms of margin of safety. The mechanical and structural characteristics of CFRP, RAS and CFRP with RAM structures were also discussed in terms of their weight.

A Study on Solar Cell Output Voltage Control for 3-Phase Utility Interactive Photovoltaic System (3상 계통연계형 태양광발전시스템의 태양전지 출력단 전압제어에 관한 연구)

  • Nam J. H.;Kang B. H.;Gho J. S.;Choe G. H.;Shin W. S.
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.571-575
    • /
    • 2002
  • Generation of electrical energy faces many problems today. Solar power converters were used to convert the electrical energy from the solar arrays to a stable and reliable power source. The object of this paper is to analyze and design DC-DC converters in a solar energy system to investigate the performance of the converters. A DC-DC converter can be commonly used to control the power flow from solar cell to load and to achieve maximum power point tracking(MPPT), DC-AC converter can also be used to modulate the DC power to AC power being applied on common utility load. A DC-DC converter is used to boost the solar cell voltage to constant 360(V) DC link and to ensure operation at the maximum power point tracking, If a wide input voltage range has to be covered a boost converter is required. In this paper, author described that simulation and experimental results of PV system contain solar modules, a DC-DC converter(boost type chopper), a DC-AC converter (3-phase inverter) and resistive loads.

  • PDF