• 제목/요약/키워드: Resistance error

검색결과 432건 처리시간 0.027초

The Vector Control of Induction Motor drives Speed Sensorless using a Fuzzy Algorithm

  • Seo, Young-Soo;Lee, Chun-Sang;Hwang, Lak-Hoon;Kim, Jong-Lae;Byong gon Jang;Kim, Joo-Lae;Cho, Moon-Tack;Park, Ki-Soo
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 ITC-CSCC -2
    • /
    • pp.1013-1016
    • /
    • 2000
  • In this study, the estimate speed of rotor in the induction motor with Model Reference Adaptive control System (MARC) principle and to study that vector control system feedbacks speed estimated to speed control system and its result is as follows; Considering with explanation an influence of speed estimation mechanism depend on error about the second resistance size established, it estimates the deviation of the second resistance establishment and exhibits a compensation method, what is more, it designs a reparation program using the fuzzy algorithm and testifies the result with the computer simulation. And besides, it composes the load torque estimation and estimates the load torque, as the result, feedback-compensating the result of estimation, it improves the efficiency. In consequence, it makes a good result for more powerful vector control system about the outside trouble.

  • PDF

부하변동에 강인한 DC/DC 승압 컨버터의 잔류 추정 (Robust Current Estimation of DC/DC Boost Converter against Load Variation)

  • 김인혁;정구종;손영익
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.2038-2040
    • /
    • 2009
  • This paper studies the state estimation problem for the current of DC/DC boost converters with parasitic inductor resistance. The parasitic resistance increases the system uncertainty when the output load variation occurs. In order to enhance the observation performance of the Luenberger observer this paper includes the integral of the estimation error signal to the estimation algorithm. By using the proposed PI observer the converter current signal is successfully reconstructed with the voltage measurement regardless of the load uncertainty. Computer simulation has been carried out by using Simulink/Sim Power System. Simulation results show the proposed method maintains robust estimation performance against the model uncertainty.

보조전극의 위치에 따른 매설지선의 접지임피던스 측정정확도의 평가 (Evaluation of Measurement Accuracy of Ground Impedances in Counterpoise according to Location of Auxiliary Electrodes)

  • 이복희;최영철;최종혁;김동규;이규선;양순만;김태기
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.352-355
    • /
    • 2009
  • The ground resistance has been used as a method of estimating the capability of counterpoise. When transient currents blow through a ground electrode, it is reasonable to evaluate the performance of ground electrode system as a ground impedance instead of ground resistance. However, the measurement method of ground impedance for counterpoise is not clearly presented. This paper describes the measurement method of ground impedance considering the earth mutual resistances and AC mutual coupling. When we measure the ground impedance, the error due to earth mutual resistances depends on the distance between the auxiliary electrodes and the electrode under test. The measurement accuracy of high frequency ground impedance is mainly influenced by the location of the current electrode and the potential electrode.

  • PDF

Application of Monte Carlo simulations to uncertainty assessment of ship powering prediction by the 1978 ITTC method

  • Seo, Jeonghwa;Park, Jongyeol;Go, Seok Cheon;Rhee, Shin Hyung;Yoo, Jaehoon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제13권1호
    • /
    • pp.292-305
    • /
    • 2021
  • The present study concerns uncertainty assessment of powering prediction from towing tank model tests, suggested by the International Towing Tank Conference (ITTC). The systematic uncertainty of towing tank tests was estimated by allowance of test setup and measurement accuracy of ITTC. The random uncertainty was varied from 0 to 8% of the measurement. Randomly generated inputs of test conditions and measurement data sets under systematic and random uncertainty are used to statistically analyze resistance and propulsive performance parameters at the full scale. The error propagation through an extrapolation procedure is investigated in terms of the sensitivity and coefficient of determination. By the uncertainty assessment, it is found that the uncertainty of resultant powering prediction was smaller than the test uncertainty.

FCP(Free-form Concrete Panel) 측면 거푸집의 측압 저항능력 실험 (Experimental Study on the Lateral Pressure Resistance of Free-form Concrete Panel (FCP) Side Form)

  • 윤종영;윤지영;이창우;이동훈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.8-9
    • /
    • 2021
  • FCP requires different curvatures and shapes according to the method of division, and it is necessary to manufacture a formwork accordingly. FCP production equipment consists of CNC equipment and side shape control equipment. This can be implemented in various shapes of upper, lower, and side surfaces. In the side shape control equipment, it is implemented as a variable side formwork. Among the required performance of the variable side formwork, there is stiffness against side pressure, which needs to be verified. Therefore, in this study, the FCP fabrication experiment is conducted with the developed variable side formwork. By analyzing the error in the shape of the fabricated FCP, the lateral pressure resistance capability of the side form is measured and verified.

  • PDF

Measurement of Crystal Formation in Supersaturated Solution

  • Kim, Byung-Chul;Kim, Young-Han
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1196-1200
    • /
    • 2003
  • The degree of supersaturation is an important measure for the operation of crystallization processes, because it is directly related to the control of crystal size distribution and shape. A conventional technique utilizing solution composition and temperature has a variety of problems caused from the measurement error and the handling of analyzing samples. A monitoring system of the supersaturation using a quartz crystal sensor is proposed here, and its performance is examined applying different manipulations of coolant temperature. The experimental outcome and photographic examination indicate that the measurements of resonant frequency and resistance of the sensor can be used for the prediction of the formation and growth of solid crystal from the crystallization process. The monitoring system eliminates the intrinsic error source of the conventional system to give the improved measurement and on-line application availability.

  • PDF

노이즈 성분을 고려한 SRM 센서리스 알고리즘의 강인성 (Robustness of a Sensorless Algorithm for Switched Reluctance Motor Considering Noise)

  • 최재동
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.717-720
    • /
    • 2000
  • The sensorless scheme for Switched Reluctance Motor(SRM) dives must have the robustness and reliability because the noise and error are sensitive. These elements make electrically noisy environments due to the proximity of high current power circuits with small signal electronic circuits when SRM drives. Also the leakage inductances and finite coupling capacitances these can cause the noise on any low voltage current and voltage measurement. the error can occur because the current and voltage including the noise are used as the input of sensorless algorithm In this paper the high robustness and resistance of input noise are described and the fuzzy logic based rotor estimation algorithm is used to reduce the tolerance of input data.

  • PDF

MRAS 방식을 이용한 PMSM 센서리스 제어 (Sensorless Control of PMSM by using MRAS Method)

  • 주경진;김종무;안호균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1011_1012
    • /
    • 2009
  • Low costed position sensor or sensorless control method is generally used in the motor control for home appliance because of the material cost and manufacture standard restriction. In conventional sensorless method, the stator resistance and back-EMF coefficient are varied by the motor speed and load torque variation. Therefore, position error occurred when the motor is operated by sensorless control method because of these variations. In this paper, the compensation method is proposed for sensorless position error using the MRAS method and compared with the other sensorless control method.

  • PDF

회전자 자속 오차를 이용한 센서리스 유도전동기 제어 시스템 (Speed-sensorless Induction Motor Control System using the Rotor Flux Error)

  • 정강률
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.123-126
    • /
    • 2003
  • This paper proposes a speed-sensorless induction motor control system using the rotor flux error. The rotor flux observer uses the reduced- dimensional state estimator technique instead of directly measuring the rotor flux. The estimated rotor speed is obtained directly from the electrical frequency, the slip frequency, and the rotor speed compensation with the estimated q-axis rotor flux. To precisely estimate the rotor flux, the actual value of the stator resistance, whose actual variation is reflected, is derived. For fast calculation and improved performance of the proposed algorithm, all control functions are implemented in software using a digital signal processor (DSP) with its environmental circuits. Also, it is shown through experimental results that the proposed system gives good performance for the speed-sensorless induction motor control.

  • PDF

웨이브렛을 이용한 혼합송전선로에서의 거리계전 알고리즘 개선 (Improvement of Digital Distance Relaying Algorithm Using Wavelet Transform in Combined Transmission Line)

  • 정채균;김경호;하체웅;이종범;윤양웅
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권10호
    • /
    • pp.593-601
    • /
    • 2003
  • Distance realy is tripped by the line impedance calculated at the relay point. Accordingly the accurate operation depends on the precise calculation of line impedance. Impedance can be accurately calculated in case of overhead line. However, in case of power cables or combined transmission lines, impedance can not be accurately calculated because cable systems have the sheath, grounding resistance, and sheath voltage limiters(SVLs). There are also several grounding systems in cable systems. Therefore, if there is a fault in cable systems, these terms will severely be caused much error to calculation of impedance. Accordingly the proper compensation should be developed for the correct operation of the distance relay. This paper presents the distance calculating algorithm in combined transmission line with power cable using wavelet transform. In order to achieve such purpose, judgement method to discriminate the fault section in both sections was proposed using D1 coefficient summation in db4. And also, error compensation value was proposed for correct calculation of impedance in power cables section.