• 제목/요약/키워드: Resistance decrease

검색결과 1,701건 처리시간 0.027초

고령자 건강증진을 위한 저항성 운동처방 시스템 구축에 관한 연구 (A Study on the Development of Resistance Exercise Prescription System for the Health Improvement of the Older Adults)

  • 왕종수;손락성
    • 디지털산업정보학회논문지
    • /
    • 제6권1호
    • /
    • pp.69-81
    • /
    • 2010
  • Physical manifestations of aging due to the lack of exercise include the slowing down of motor learning, cardiopulmonary degradation, and the increasing difficulty to adapt to the environment. Aging is manifested with the lack of aerobic exercise work, decrease in muscular endurance, decline in skeletal and muscular strength, flexibility and agility, and the decrease in reaction speed and balance. Added to those are aging-related physiological changes, including the reduction of muscle bulk, increased body fat, decrease in total body water and basic metabolic rate as activities are reduced, and a decrease in cell and Lean Body Mass (LBM). These changes are known to cause problems. Interest and participation in appropriate physical activities among the elderly is needed to help them increase stamina, avoid diseases, maintain a clear intellect, and basically enable the elderly to live their daily lives as easy as possible. Therefore, physical activities are necessary for the elderly to enhance health-related factors. Special exercises should be performed for the enhancement of muscle function, muscle endurance, flexibility, agility, and balance. An accurate measurement of cardio-respiratory endurance and stamina through basic physical and cognitive characteristics of older adults is also required to ensure safety. Also, the development of a more scientific resistance exercise prescription system for the elderly is desperately needed.

부스바 접점 가동시 접촉면에서 압점력 해석 (Analysis for Force Distribution on Surface Between Busbar Contacts)

  • 오연호;송기동;김귀식;김진기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.82-84
    • /
    • 2003
  • In case contact between point of contacts is not achieved well, contact resistance is grown, and by current concentration at current conducting contacts can weld. In order to decrease contact resistance between contacts in case of busbar, installing spring between fixed contact and moving contact. and then force on faying surface of contacts increase and contact resistance decrease. But, in case increase force of spring to widen contact area, operating force moving contact can grow, on the contrary force of spring is small, contact resistance becomes low. Therefore, need to optimize force and number of spring. position, and also need to examine force change on contact surface at point of contact moving. In this paper, dynamic kinetics analysis for force on faying surface of contacts is performed at unsteady state. It is showed to not uniform force on surface between contacts, and we can got more uniform force by means of change spring position.

  • PDF

쾌속여객선의 POD 형상에 따른 압력과 속도 분포에 관한 연구 (A Study on the Pressure and Velocity Distributions by POD Shape of Hydrofoil Vessel)

  • 이춘기;임태우;문성배
    • 수산해양교육연구
    • /
    • 제26권4호
    • /
    • pp.831-837
    • /
    • 2014
  • This paper focuses on the effects of the changes in the resistance characteristics caused by the changes of the POD shape installed in the Hydrofoil vessel, using the CFD(Computational Fluid Dynamics). We input the POD sections' basic shape as the origin of the x and y axis. Then as we cut the x-axis 0 to 2 cm, and the more we cut it, the total resistance value had increased. However, we have recognized the fact that as we cut the POD section, 3 to 5 cm, the resistance value had rather decreased. Furthermore we found out the result that as the cut partition was larger; the POD cross-section would decrease, resulting in the linear decrease of the viscous force.

접촉저항 및 전기전도도가 연료전지 성능에 미치는 영향 (The Effect of Contact Resistance and Electric Conductivity on PEMFC Performance)

  • 김기정;윤용식;전유택
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.133-136
    • /
    • 2007
  • In this work, 3-dimensional, non-isothermal numerical simulation was performed to analyse the effects of contact resistance and electric conductivity of GDL on the fuel cell performance. For numerical simulation contact resistance of Carbon and Stainless steel was measured. The simulation results reveal that 10 times change of electric conductivity leads only 6.5% decrease of PEMFC performance. But stainless steel which has high contact resistance decrease fuel cell performance over 25% at a high current density region than carbon. This results show that suitable Surface treatment technology is needed for metal bipolar plate, especially stainless steel.

  • PDF

Ar 플라즈마 처리에 따른 Al-doped ZnO 박막특성변화 (The effect of Ar plasma treatment on Al-doped ZnO)

  • 진선문;안철우;조남인;남형진
    • 반도체디스플레이기술학회지
    • /
    • 제10권4호
    • /
    • pp.43-46
    • /
    • 2011
  • In this study, we investigated the effects of the post Ar plasma treatment at different RF powers for various durations on electrical, structural, and optical properties of relatively thin Al-doped zinc oxide films. The sheet resistance was observed to decrease rapidly for the first 5min, beyond which the resistance apparently saturated. As the RF power increased, the grain size and the interplanar distance of (002) planes also increased. The observed decrease in sheet resistance was stated to be a consequence of Al and/or Zn interstitials as well as grain growth. It was also found that Ar plasma treatment increased the transmittance of Al-doped zinc oxide films in most of the visible light range below the blue light.

접촉저항 및 전기전도도가 연료전지 성능에 미치는 영향 (The Effect of Contact Resistance and Electric Conductivity on PEMFC Performance)

  • 김기정;윤용식;전유택
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2012년도 춘계학술발표회 논문집
    • /
    • pp.184-186
    • /
    • 2012
  • In this work, 3-dimensional, non-isothermal numerical simulation was performed to analyse the effects of contact resistance and electric conductivity of GDL on the fuel cell performance. For numerical simulation contact resistance of Carbon and Stainless steel was measured. The simulation results reveal that 10 times change of electric conductivity leads only 6.5% decrease of PEMFC performance. But stainless steel which has high contact resistance decrease fuel cell performance over 25% at a high current density region than carbon. This results show that suitable Surface treatment technology is needed for metal bipolar plate, especially stainless steel.

  • PDF

Fontan 시술 이후 환자의 혈류역학적 상태에 대한 수치적 연구 (Computational study of the hemodynamics of the patients after the Fontan procedure)

  • 심은보;고형종;김경훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.371-376
    • /
    • 2000
  • In this study, the computational method is presented to simulate the hemodynamics of the patients after the Fontan procedure. The short-term feedback control models are implemented to assess the hemodynamic responses of the patients exposed to the stresses such as gravitational effect or hemorrhage. To construct the base line of the Fontan model, we assume an increase in venous tone, in heart rates, and in systemic resistance that are based on the clinical observations. For the verification of the present method we simulate the LBNP (lower body negative pressure) test for the normal and the Fontan model and we compare these with experimental data. Computational results show that the diastolic ABP(arterial blood pressure) increases but the systolic ABP decreases during LBNP. The increase in heart rate is due to the control system activated by the decreased mean ABP and CVP(central venous pressure). In case of the Fontan model, the increased venous tone is the reason of the diminished CVP change during LBNP. We also simulate 20% hemorrhage stress to the patient after the Fontan procedure and these results are compared with the experimental and the existing computational one. Computational results on the hemodynamics of patients after the Fontan procedure show that the mean ABP and cardiac output decrease. Heart rate and systemic resistance increase to compensate for the decrease in ABP. The sensitivity analysis according to the conduit resistance is also presented to delineate the effects of the local blood flow resistance. The cardiac output decreases according to the increase of the conduit resistance. The 50% increase in the conduit resistance causes about 3% decrease of cardiac output.

  • PDF

(Ga,Al)이 도핑된 ZnO를 투명전극으로 가진 Cu(In,Ga)Se2 태양전지에 수분이 미치는 영향 (Effect of Moisture on Cu(In,Ga)Se2 Solar Cell with (Ga,Al) Co-doped ZnO as Window Layer)

  • 양소현;배진아;송유진;전찬욱
    • Current Photovoltaic Research
    • /
    • 제5권4호
    • /
    • pp.135-139
    • /
    • 2017
  • We fabricated two different transparent conducting oxide thin films of ZnO doped with Ga ($Ga_2O_3$ 0.9 wt%) as well as Al ($Al_2O_3$ 2.1 wt%) (GAZO) and ZnO doped only with Al ($Al_2O_3$ 3 wt%) (AZO). It was investigated how it affects the moisture resistance of the transparent electrode. In addition, $Cu(In,Ga)Se_2$ thin film solar cells with two transparent oxides as front electrodes were fabricated, and the correlation between humidity resistance of transparent electrodes and device performance of solar cells was examined. When both transparent electrodes were exposed to high temperature distilled water, they showed a rapid increase in sheet resistance and a decrease in the fill factor of the solar cell. However, AZO showed a drastic decrease in efficiency at the beginning of exposure, while GAZO showed that the deterioration of efficiency occurred over a long period of time and that the long term moisture resistance of GAZO was better.

$FeS_2$ 양극에 미치는 전도성 첨가제의 영향 (Effect of Conductive Additives on $FeS_2$ Cathode)

  • 최유송;정해원;김기열;조성백
    • 한국군사과학기술학회지
    • /
    • 제15권2호
    • /
    • pp.224-230
    • /
    • 2012
  • Thermal batteries have excellent mechanical robustness, reliability, and long shelf life. Due to these characteristics as well as their unique activation mechanism, thermal batteries are widely adopted as military power sources. Li(Si)/$FeS_2$ thermal batteries, which are used mostly in these days, use LiCl-KCl and LiBr-LiCl-LiF as molten salt electrolyte. However, it is known that Li(Si)/$FeS_2$ thermal batteries have high internal resistance. Especially, $FeS_2$ cathode accounts for the greater part of internal resistance in unit cell. Many efforts have been put into to decrease the internal resistance of thermal batteries, which result in the development of new electrode material and new electrode manufacturing processes. But the applications of these new materials and processes are in some cases very expensive and need complicated additional processes. In this study, internal resistance study was conducted by adding carbon black and carbon nano-tube, which has high electron conductivity, into the $FeS_2$ cathode. As a results, it was found that the decrease of internal resistance of $FeS_2$ cathode by the addition of carbon black and carbon nano-tube.

전기콘센트의 사용환경과 전류값에 따른 열적특성 및 절연저항 분석 (Analysis of Thermal Characteristics and Insulation Resistance based on Usage Environment and Current Value of Electrical Socket Outlet)

  • 김경천;김두현;김성철
    • 한국안전학회지
    • /
    • 제34권5호
    • /
    • pp.22-30
    • /
    • 2019
  • In 2018, overload, overcurrent, insulation aging, and a contact failure caused 659 electric fires. There is almost no failure of electrical socket outlets during their manufacturing or installation period. After several months or several years, overload or overcurrent of electrical socket outlets leads to a contact failure or short circuit which causes an electric fire. Therefore, this paper analyzed for thermal characteristics based on a current value and the change in insulation resistance along with a temperature rise caused by electrical socket outlets and the state of laboratory use in workplaces. As a results, regarding the thermal characteristics based on the current value of each installation year, a temperature increase was related to a current value, an installation year, and whether the contact unit is corroded. Insulation resistance began to decrease when a temperature increased to a certain level. With a lapse of installation year, the temperature at which insulation resistance began to decrease was lowered. This paper can be applicable for the survey data about electrical socket outlet induced fire accidents and management guidelines.