• Title/Summary/Keyword: Resistance coupling

Search Result 250, Processing Time 0.027 seconds

Transistor Wide-Band Feedback Amplifiers (트랜지스터 광대역궤환증폭기)

  • 이병선;이상배
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.5 no.1
    • /
    • pp.13-25
    • /
    • 1968
  • A detailed analysis of the transistor wide-band feedback amplifiers using the hybrid-$\pi$ equivalent circuit has been made. It is considered both for the low freqnency and for the high frequency. The expressions of the gain, bandwidth. input impedance and output impedance have been presented. It is shown that a series feedback amplifier should be driven from the voltage source and should drive into the low resistance load, and a shunt feedback amplifier should be driven from the current source and should drive into the high resistance load. It is also shown that these stages can be coupled without use of the buffer stage or coupling transformer.

  • PDF

New Modeling Method for an Electrodeless Fluorescent Lamp Using the Relation of Lamp Output Power and the Modeling Coefficients of the Lamp (무전극램프의 출력전력 변화에 따른 새로운 모델링 기법)

  • Lim, Byoung-Noh;Jang, Mog-Soon;Sin, Dong-Seok;Park, Chong-Yeun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1626-1631
    • /
    • 2007
  • This paper presents a new modeling method using lamp output power and the modeling coefficients of the lamp. The proposed method utilizes the lamp modeling coefficients such as equivalent impedance Z(p), coupling coefficient of the transformer k(p), turns ratio of the transformer n(p), and plasma resistance Rp(p) as a function of lamp output power. The equivalent impedance Z(p) was developed from the equivalent resistance Req(p) and equivalent inductance Leq(p) of the lamp. Simulation and experimental results of the proposed model are presented in order to validate the proposed method. The modeling method can use to design an impedance matching circuit for a Class-D inverter.

Polymeric Humidity Sensor Using Polyelectrolyte Derived from Poly(amide-sulfone)s

  • Jeon, Young-Min;Gong, Myoung-Seon
    • Macromolecular Research
    • /
    • v.17 no.4
    • /
    • pp.227-231
    • /
    • 2009
  • New polyelectrolytes derived from poly(amide-sulfone)s and 1,5-dibromopentane were simultaneously fabricated on the electrode by the crosslinking reaction. The substrate was pretreated with a bromoalkyl-containing, silane-coupling agent to anchor the humidity-sensitive membrane to the substrate through the covalent bond. When the resistance dependence on the relative humidity of the crosslinked poly(amide-sulfone)s was measured, the resistance varied by three orders of magnitude between 20%RH and 90%RH, which was the required RH range for a humidity sensor operating at ambient humidity. Their water durability, long-term stabilities under various environments, hysteresis and response and recovery times were measured and evaluated as a humidity-sensing membrane.

The Effect of Piezoelectric Properties on the Output Properties of Step-down Multilayer Piezoelectric Transformer (압전특성이 강압용 적층 압전변압기의 출력특성에 미치는 영향)

  • Kim, Kook-Jin;Yoo, Ju-Hyun;Paik, Dong-Soo;Yoon, Hyun-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.225-227
    • /
    • 2006
  • Multilayer step down piezoelectric transformers were manufactured using PZN-PMN-PZT and PMN-PNN-PZT ceramics respectively. Sintering temperature of the ceramics was $940^{\circ}C$. And then. their electrical properties were investigated according to the variations of frequency and load resistance. The voltage step-up ratio of multilayer piezoelectric transformer showed the maximum values in the vicinity of 69 and 71kHz, respectively. At the load resistance of $100{\Omega}$, the piezoelectric transformers showed the temperature rises of about 21 and $18^{\circ}C$ at the output power of 15W and 18W, respectively. At the transformer with high effective electromechanical coupling factor($k_{eff}$), lower temperature increase was appeared.

  • PDF

Analysis of the Earth Resistance for the Tower Footing of T/L (송전선로 철탑기초의 접지저항 해석)

  • Lee, H.G.;Ha, T.H.;Bae, J.H.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.344-346
    • /
    • 2001
  • The sharing of common corridors by electric power transmission lines and pipelines is becoming more common place. However, such corridor sharing can result in undesired coupling of electromagnetic energy from the power lines to the near facilities. During a fault on any of the transmission lines, energization of the earth by supporting structures near the fault can result in large voltages appearing locally between the earth and the steel wall of any nearby pipeline. This paper presents the outline of the tower footings for the transmission lines having been used in KEPCO and analyzes the earth resistance for operation method of the tower footing, that is contact presence for the anchor and reinforcing rob of the tower and foundation presence of the underground wiring.

  • PDF

Equivalent Circuit Model For Switching Performance of Bipolar Spin Transistor

  • Yong Tae, Kim;Gap Yong, Lee
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2003.12a
    • /
    • pp.182-185
    • /
    • 2003
  • We have suggested an equivalent circuit model for switching performance of bipolar spin transistor composed of a nonmagnetic metal film (N) sandwiched between two ferromagnetic metal films (F1 and F2). The 'ON' or 'OFF' operation of this equivalent circuit model is simulated by depending on the orientation of the magnetization of F1 and F2 rather than the strength of the external magnetic filed. Changing the coupling coefficient, turn number of two inductances, (L1:L2) like a transformer, and parallel variable resistance R4 connected to L2 at the collector region, we can explain the magnetic characteristics and the dependence of magneto resistance ratio on the orientation of spin-polarized electrons.

  • PDF

Study on Property Modification with Fire Retardant Content in the Manufacture of Compounds for Cable Sheath (전선피복용 컴파운드의 제조에서 난연제의 첨가량에 따른 물성 변화 연구)

  • Li, Xiangxu;Lee, Sang Bong;Cho, Ur Ryong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.3
    • /
    • pp.47-51
    • /
    • 2019
  • The three different polymer compounds were manufactured with the three different fire retardant (silane coated magnesium dihydroxide) contents, 180, 200, 220 phr, for making cable sheath for ship industry. In the research, ethylene-vinylacetate, polyethylene as matrix polymers and ethylene-vinylacetate grafted maleic anhydride as coupling agent were selected for compounding with fire retardant, closslinking agent, plasticizer, and other additives. In the evaluation. ΔT, Mooney viscosity, and tensile strength increased with the content of fire retardant. But it was found that too much fire retardant damaged aging resistance and cold resistance of the polymer compound.

Electrical Characteristics of Helicon Wave plasmas (헬리콘 플라즈마의 전기적 특성)

  • 윤석민;김정형;서상훈;장흥영
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.1
    • /
    • pp.85-92
    • /
    • 1996
  • The external electricla characteristics of helicon wave plasmas were measured over a wide range of RF power and magnetic filed. External parameters. such as antenna voltage , current, phase shift, and interanl parameter, electron density were measured at 7MHz, 1mTorr Ar discharge . The equivalent discharge resistance and reactance, and the power transfer efficiency were calculated through these measurements. There are a helicon mode which produces high density plasma by helicon wave and a lowmode which produces low density plasma by capaictive electric field. In case of the helicon mode, the anternna voltage and current were lower than those of the low-mode. The phase difference between voltage and current decreased suddenly at the transition point from the low-mode to the helicon mode. Equivalent resistance and power efficiency increased and reactance decreased suddenly at the transition point. These results mean that the power transperred to plasma and the nutual coupling between the antenna and plasma increase as the mode changes from the low-mode to the helicon mode.

  • PDF

Evaluation of Measurement Accuracy of Ground Impedances in Counterpoise according to Location of Auxiliary Electrodes (보조전극의 위치에 따른 매설지선의 접지임피던스 측정정확도의 평가)

  • Lee, Bok-Hee;Choi, Young-Chul;Choi, Jong-Hyuk;Kim, Dong-Kyu;Lee, Gyu-Sun;Yang, Soon-Man;Kim, Tae-Gi
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.352-355
    • /
    • 2009
  • The ground resistance has been used as a method of estimating the capability of counterpoise. When transient currents blow through a ground electrode, it is reasonable to evaluate the performance of ground electrode system as a ground impedance instead of ground resistance. However, the measurement method of ground impedance for counterpoise is not clearly presented. This paper describes the measurement method of ground impedance considering the earth mutual resistances and AC mutual coupling. When we measure the ground impedance, the error due to earth mutual resistances depends on the distance between the auxiliary electrodes and the electrode under test. The measurement accuracy of high frequency ground impedance is mainly influenced by the location of the current electrode and the potential electrode.

  • PDF

A Study on the Investigation of Users Guide of One-Way Coupled Analysis for Performance-Based Structural Fire Resistance Design (성능기반 구조내화설계를 위한 단방향 연성해석 사용자가이드 조사에 관한 연구)

  • Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.96-97
    • /
    • 2021
  • In the Building Act, performance-based fire safety design is being promoted for institutionalization. The behavior of the structure against fire conditions can be predicted by using the advanced numerical analysis method based on the FEM (Finite Element Method) to predict the entire structural behavior including the behavior of the structure, but there is a limit to expressing the fire properties of the space and predicting the fire properties It is difficult to determine the variables to be transmitted to the FEM (Finite Element Method) model from the fire simulation results using FDS (Fire Dynamics Simulator). Accordingly, the purpose of this study is to introduce the code user's manual for FDS and FEM unidirectional coupling analysis.

  • PDF