• 제목/요약/키워드: Resistance Factor

검색결과 2,207건 처리시간 0.035초

고속카메라를 이용한 저항 점 용접의 너겟 형성 메커니즘 관찰 (Observation of Nugget Formation Mechanism by using High Speed Camera)

  • 조용준;이세헌
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2000년도 특별강연 및 추계학술발표대회 개요집
    • /
    • pp.43-45
    • /
    • 2000
  • Resistance Spot Welding has been one of the important process in the sheet metal fabrication of auto-body industry It is well known that the nugget formation of RSW is the major factor for the strength of the body. A high speed camera was used to consider initial melting and growth of the weld nugget in order to find out the nugget formation mechanism. It was observed that such mechanism had an effect on the dynamic resistance, which was a process parameter of resistance spot welding. Also, the relationship between the mechanism and process parameter was considered for the industrial application.

  • PDF

고장저항의 영향을 최소화한 순환형 거리계전 알고리즘 (A Recursive Distance Relaying Algorithm Immune to Fault Resistance)

  • 안용진;강상희;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.259-261
    • /
    • 2001
  • An accurate digital distance relaying algorithm which is immune to the combined reactance effect of the fault resistance and the load current is proposed. The algorithm can estimate adaptively the impedance to a fault point independent of the fault resistance. To compensate the apparent impedance, this algorithm uses iteratively the angle of an impedance deviation vector improved step by step. The impedance correction algorithm for ground faults uses a current distribution factor to compensate mutual coupling effect.

  • PDF

말뚝기초의 국제적 설계기준에 관한 고찰 (Study on International Code of Practice for Pile Foundation)

  • 윤길림;권오순;차재선
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 말뚝기초위원회 워크샵
    • /
    • pp.35-52
    • /
    • 1999
  • This paper addresses on new codes of practice, limit state design; load resistance factored design and Eurocode 7, which have recently been adopted by foundation engineers in North America and European Communities. A brief description of the limit state design concepts and some introductions to Australia and Sweden national code for pile foundation are made on behalf of pile capacity determination. Also, simple closed form solution for rational resistance factor when resistance is log-normally distributed, has been derived for pile foundation.

  • PDF

PBD의 배수특성과 대심도 지반개량 (Discharge Capacity of PBD and Deep Soft Soil Improvement)

  • 구본효
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.585-592
    • /
    • 2002
  • Discharge capacity of PBD is the most important factor of specification items to control any product of PBD. There is no standard specification for the PBD. Because the degree of discharge capacity is related to well resistance, install depth, maximum strain etc in the field. Discharge capacity test of PBD, permeability test of filter are conducted using PBD materials used in Korea. This paper proposes the critical discharge capacity for deep PBD under condition of non well resistance based upon their test and theoretical calculation. It was found that discharge capacity more than about 10 ㎤/sec is enough to undergo designing of deep PBD without well resistance.

  • PDF

Biochemical Characterization of Adriamycin-Resistance in PC-14 Human Lung Adenocarcinoma Cell Line

  • Yi, Jae-Youn;Hong, Weon-Seon;Son, Young-Sook
    • BMB Reports
    • /
    • 제34권1호
    • /
    • pp.66-72
    • /
    • 2001
  • To investigate the mechanism of adriamycin (ADM) resistance in the ADM resistant subline PC-14/ADM, we examined the expressions of p-glycoprotein (P-gp), topoisomerase I (Topo I) and II (Topo II), glutathione-S-transferases (GSTs), tissue transglutaminase (t-TG), epidermal growth factor receptor (EGFR), and E-cadherin and the activity of superoxide dismutase (SOD) in PC-14 and PC-14/ADM cells. There was no change in the cellular levels of P-gp, Topo I, Topo II, and the two isoforms of GSTs. However, SOD activity in PC-14/ADM cells was 2.38 fold higher than that in PC-14 cells. A marked induction of the t-TG expression was also observed in PC-14/ADM cells. In addition to those changes, expressions of EGFR and E-cadherin were down regulated in PC-14/ADM cells. Therefore, molecular modifications such as an increase in SOD activity, induction of the t-TG expression, and down regulation of EGFR and E-cadherin expressions may play important roles in PC-14/ADM cells during the development of ADM resistance.

  • PDF

Enhanced bacterial resistance in transgenic tobacco expressing a BrRZFP1 encoding a C3HC4-type RING zinc finger protein from Brassica rapa

  • Jung, Yu Jin;Nou, Ill Sup;Hong, Sung Kee;Lee, Young Kee;Cho, Yong Gu;Kang, Kwon Kyoo
    • Journal of Plant Biotechnology
    • /
    • 제40권1호
    • /
    • pp.49-54
    • /
    • 2013
  • C3HC4-type RING zinc finger proteins essential in the regulation of plant processes, including responses to abiotic stresses. We previously isolated and examined the C3HC4-type RING zinc finger protein (BrRZFP1) from Brassica rapa under abiotic stresses. To elucidate the role of the BrRZFP1 transcription factor in gene regulation, we transformed tobacco plants with the BrRZFP1 gene. Plants were regenerated from 82 independently transformed callus lines of tobacco and analysed for transgene expression. Transgene integration and expression was confirmed by Southern and RT-PCR analyses, respectively. T2 plants displayed more tolerance to the bacterial pathogens Pectobacterium carotovorum and Ralstonia solanacearum, and the tolerance levels were correlated with BrRZFP1 expression levels. These results suggest that the transcription factor BrRZFP1 is an important determinant of stress response in plants and its overexpression in plants could increase biotic stress resistance.

다공성 건축자재의 투습 및 통기성 분석에 대한 연구 (Analysis of Water-Vapor Permeance and Ventilation Property of the Porous Construction Materials)

  • 김종원;안영철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.754-757
    • /
    • 2008
  • To maintain the indoor air quality, many ventilation systems and technologies have been developed in the highly insulated and air tight buildings. In this study, a porous construction material, which is applicable to passive ventilation system, is developed and measured the performances of the permeability and the resistance of water vapor, and the dust collection efficiency. The average coefficient of water vapor permeability shows $3.6\;g/m^2{\cdot}h{\cdot}mmHg$, which is slightly higher than Hanji ($2.4{\sim}3.2\;g/m^2{\cdot}h{\cdot}mmHg$) and the average water vapor resistance factor shows $0.303\;g/m^2{\cdot}h{\cdot}mmHg/g$, which is slightly smaller than Hanji($0.309{\sim}0.315\;g/m^2{\cdot}h{\cdot}mmHg/g$). The pressure drop of the porous construction material is smaller than the HEPA filter and the minimum dust collection efficiency shows 82.8% in the range of $2{\sim}9\;cm/s$.

  • PDF

재료저항계수와 부재저항계수를 적용한 콘크리트 성능설계의 신뢰도기반 계수보정 (Reliability-based calibration for performance-based design of concrete structures with material and member resistance factors)

  • 백인열;신수봉;방대재
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.145-148
    • /
    • 2008
  • 현재 국제적인 콘크리트설계기준의 동향은 한계상태의 개념을 기본으로 하여 구조물에 요구되는 성능을 중심으로 새로이 한계상태를 정의하려는 노력이 진행되고 있다. 이를 위해서는 구조물의 요구성능을 정의하고 성능수준에 대한 만족도를 측정하는 등의 과제를 해결해야 하는 문제가 놓여있다. 성능을 만족하는 정도를 나타낼 수 있는 지수로는 현재 신뢰도지수가 가장 주목받고 있다. 이 논문에서는 PSC beam을 대상으로 단면력저항계수 및 재료저항계수 체계로 설계를 시행한 후, 여러가지의 서로 다른 저항계수 세트에 대한 신뢰도지수를 각각 구하여 값을 비교하였다. 향후 주어진 목표신뢰도 수준에 부합하는 저항계수 조합을 산정하는 기초 자료로 사용할 수 있다.

  • PDF

국내 모듈러 건축의 내화구조 제도 현황 및 활성화 방안 (Fire Resistant Regulation Status and Activation Plan of Domestic Modular Construction)

  • 최윤정;안재홍
    • 한국건축시공학회지
    • /
    • 제22권6호
    • /
    • pp.673-680
    • /
    • 2022
  • 모듈러 건축은 시공 기간의 단축, 건축비용 절감 등의 여러 가지 장점에도 불구하고 국내 건설시장에서 좀처럼 탄력을 받지 못하고 있다. 이러한 원인에는 모듈러 내화 기술 적용의 한계도 있으나 무엇보다 내화구조 제도에 대한 접근성이 쉽지 않은 것이 주요 요인으로 간주되고 있다. 따라서 모듈러 건축 활성화를 위해 주요 저해요인인 내화구조 제도 현황과 문제점에 대해 고찰하였으며, 내화구조 제도적 개선 및 연구개발 방향에 대해 제시하고자 한다.

상악 견치의 저항 중심에 관한 Laser speckle interferometry와 holographic interferometry볼 이용한 실험적 연구 (EXPERIMENTAL STUDY OF THE CENTER OF RESISTANCE OF A MAXILLARY CANINE USING LASER SPECKLE INTERFEROMETRY AND HOLOGRAPHIC INTERFEROMETRY)

  • 이수룡
    • 대한치과교정학회지
    • /
    • 제18권2호
    • /
    • pp.289-308
    • /
    • 1988
  • The center of resistance is a important determining factor of tooth movement pattern. Laser speckle interferometry, recently developed for noninvasive measurement of small displacements (microns), was used to detect the center of resistance of a maxillary canine which has normal tooth axis and distal curved root in dry human skull. Laser holographic interferometry was used to verify the results of laser speckle interferometry The following result were obtained; 1. In measurement of the degree of rotation, center of resistance was localized when the traction line passed 4.4/18.0 level from alveola crest to root apex. 2. In measurement of the degree of tipping, center of resistance was localized when the traction line passed 4.6/18.0 level from alveola crest to root apex. 3. In holographic determination, the center of resistance was observed when the traction line passed between 3mm to 6mm level from alveola crest to root apex, therefore the results using laser speckle interferometry was coincided with holographic results.

  • PDF