• Title/Summary/Keyword: Resin types

Search Result 596, Processing Time 0.04 seconds

Solid-Phase Refolding Technology in Recombinant Proteins Recovery: Application Examples to Various Biopharmaceutical Proteins (유전자재조합 단백질 회수 공정에서의 고체상 재접힘 기술: 여러 바이오의약 단백질에의 적용 사례)

  • Kim, Min Young;Suh, Chang Woo;Kim, Chang Sung;Jo, Tae Hoon;Park, Sang Joong;Choi, Won Chan;Lee, Eun Kyu
    • Korean Chemical Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.187-201
    • /
    • 2005
  • Bioprocessing technologies utilizing 'biorecognition' between a solid matrix and a protein is being widely experimented as a means to replacing the conventional, solution-based technology. Frequently the matrices are chromatographic resins with specific functional groups exposed outside. Since the reactions of and interactions with the proteins occur as they are attached to the solid matrix, this 'solid-phase' processing has distinct advantages over the solution-phase technology. Solid-phase refolding of inclusion body proteins uses ion exchange resins to adsorb denaturant-dissolved inclusion body. As the denaturant is slowly removed from the micromoiety around the protein, it is refolded into a native, three-dimensional structure. Once the refolding is complete, the folded protein can be eluted by a conventional elution technique such as the salt-gradient. This concept was successfully extended to 'EBA (expanded bed adsorption)-mediated refolding,' in which the denaturant-dissolved inclusion body in whole cell homogenate is adsorbed to a Streamline resin while cell debris and other impurity proteins are removed by the EBA action. The adsorbed protein follows the same refolding steps. This solid-phase refolding process shows the potential to improve the refolding yield, reduce the number of processing steps and the processing volume and time, and thus improve the overall process economics significantly. In this paper, the experimental results of the solid-phase refolding technology applied to several biopharmaceutical proteins of various types are presented.

Maxillofacial rehabilitation of hemi-maxillectomy patient using a closed hollow bulb obturator fabricated by one-step polymerization technique: a clinical report (상악골 부분절제술 시행 환자에서 one-step 중합 기술로 만든 hollow bulb 폐색장치를 이용한 악안면 수복 증례)

  • Sim, Jae-Hyuk;Kim, Min-Kyoo;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun;Yeo, In-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.1
    • /
    • pp.35-40
    • /
    • 2016
  • The maxillary defects lead to anatomical and functional deformity of the maxillofacial region. As far as functions are concerned, such defects can produce difficulty in speech, mastication, and deglutition. Obturator prostheses play a very important role in functional recovery for post-maxillectomy patients. To achieve rigidity of the obturator, appropriate retention should be given, and the weight of the prosthesis be reduced. There are two types of hollow bulb obturator: open and closed. A closed type has many advantages. Nevertheless, some problems, including complexity of fabrication and water leakage into the bulb, have the closed hollow obturator not be widely used. The one-step polymerization technique described in this case overcomes the shortcomings by easily constructing a small hollow bulb with two thermoplastic resin sheets.

EFFECT OF MICROLEAKAGE OF A SELF-ETCHING PRIMER ADHESIVE ACCORDING TO TYPES OF CUTTING INSTRUMENTS (삭제기구가 자가 산부식 접착제의 미세누출에 미치는 영향)

  • Kim, Yong-Hee;Park, Jae-Gu;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.327-334
    • /
    • 2007
  • The purpose of this study was to evaluate the effect of burs on microleakage of Class V resin restorations when a self-etching primer adhesive was used. Forty Class V cavities were prepared with four different cutting burs on extracted third molars, and divided into one of four equal groups (n = 10); Group 1-plain cut carbide bur (no. 245), Group 2-cross cut carbide bur (no. 557), Group 3-fine diamond bur (TF-21F), Group 4-standard diamond bur (EX-41). The occlusal and gingival margin of cavities was located in enamel and dentin, respectively. Cavities were treated with Clearfil SE Bond and restored with Clearfil AP-X. Specimens were thermocycled, immersed in a 2% methylene blue solution for 24 hours, and bisected longitudinally. They were observed leakages at enamel and dentinal margins. Data were analyzed using Mann-Whitney and Wilcoxon signed ranked test. The results of this study were as follows; 1. At enamel margin, microleakage of group 4 was statistically higher than those of group 1, 2 and 3 (p < 0.01). 2. At dentinal margin, microleakage of group 4 was statistically higher than group 3 (p < 0.01), but group 1 and 2 were not statistically different with group 3 and 4. 3. Enamel microleakage was statistically higher than dentinal microleakage in group 1, 2 and 3 (p < 0.05), but statistical difference between the microleakage of enamel and dentinal margin was not in Group 4. In conclusion, the use of coarse diamond bur showed high microleakage at both enamel and dentinal margin when Clearfil SE Bond was used in class V cavity.

Studies on the Determination Method of Hydrogen Peroxide in Foods (식품 중 과산화수소의 분석법에 관한 연구)

  • Lee, Tal-Soo;Lee, Young-Ja;Park, Jae-Seok;Kwon, Yong-Kwan;Hwang, Jung-Yeon;Lee, Ju-Yeun;Lee, Chul-Won
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.6
    • /
    • pp.998-1001
    • /
    • 2002
  • Micro-LC method for the quantitative determination of hydrogen peroxide in foods has been established. This method was carried out on cation-exchange resin gel column using distilled water as mobile phase with 50 mM sodium sulfate as electrolyte. The detection was performed with an electrochemical detector (ECD) at 0.6 voltage. Under this analytical condition, the recovery rates of hydrogen peroxide in tomato and lemon were 98.3 and 97.4%, respectively. Among 28 food types, hydrogen peroxide concentrations were 0.6, 0.5, 1.9, 0.9, 0.5, 0.6, 0.9, 0.8, and 0.4 ppm in banana, peach, orange, strawberry, pepper, onion, cucumber, burdock, and egg plant, respectively, Whereas none was detected in remaing 19 samples.

Fabrication of additive manufacturing interim denture and comparison with conventional interim denture: A case report (적층가공을 이용한 임시의치 제작 및 기존방식의 임시의치와의 비교 증례)

  • Kim, Hyun-Ah;Lim, Hyun-Pil;Kang, Hyeon;Yang, Hongso;Park, Sang-Won;Yun, Kwi-Dug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.483-489
    • /
    • 2019
  • With development of digital dentistry, the 3-dimensional (3D) manufacturing industry using computer-aided design and computer-aided manufacturing (CAD/CAM) has grown dramatically in recent years. Denture fabrication using digital method is also increasing due to the recent development of digital technology in dentistry. The 3D manufacturing process can be categorized into 2 types: subtractive manufacturing (SM) and additive manufacturing (AM). SM, such as milling is based on cutting away from a solid block of materal. AM, such as 3D printing, is based on adding the material layer by layer. AM enables the fabrication of complex structures that are difficult to mill. In this case, additive manufacturing method was applied to the fabrication of the resin-based complete denture to a 80 year-old patient. During the follow-up periods, the denture using digital method has provided satisfactory results esthetically and functionally.

Study on the Demand Characteristics of Epoxy Resins Applied to the Restoration of Ceramics (도자기 복원에 사용되는 에폭시계 고분자수지의 요구 특성 연구)

  • Nam, Byeongjik;Jeong, Seri;Jang, Sungyoon
    • Journal of Adhesion and Interface
    • /
    • v.13 no.4
    • /
    • pp.171-181
    • /
    • 2012
  • The demand characteristics of the conventional 12 kinds of epoxy resins which have been used for restoration of the ceramic relics were investigated to provide standards of the effective materials in this study. The result of durability analysis showed that a liquid type is more effective in ceramic relics (low damage, high strength), and a paste type is more effective in earthenware relics (high damage, low strength). The result of workability analysis appears that the liquid type is higher than the paste type, and a slow curing type is higher than a fast curing type in surface hardness. Therefore, in the case of the liquid type which is hard to reprocess due to high surface hardness, it is necessary to conduct a study on improving physical properties by adding filler. The result of the gloss analysis on epoxy resins showed that the liquid type (colorless) has higher gloss than the paste type, and the slow curing type has higher gloss than the fast curing type in liquid types. CDK-520A/520B and Araldite SV 427-2/HV 427-1 showed the most similar gloss to $700^{\circ}C$ earthenware, Devcon 5 minute, EPO-TEK 301-2, and Quik Wood showed the most similar gloss to celadon and whiteware, Quik Wood, EPO-TEK 301-2, and Devcon 5 minute showed the most similar gloss to buncheongware. It is necessary for conservator to decide the range of the restoration surface by predicting the increase and decrease of the restoration surface because most of the epoxy resins caused the volume change in curing process.

A Study on the Retouching Materials for Oil Paintings - Using Restoration Colors and Acrylic Gouache - (유화 작품 색맞춤용 재료 특성 연구 - 복원용 물감과 아크릴과슈를 중심으로 -)

  • Choi, Hee Jin;Kang, Dai Ill
    • Journal of Conservation Science
    • /
    • v.37 no.5
    • /
    • pp.426-439
    • /
    • 2021
  • In this study, we compare the properties and estimate the durability of five oil colors that are the most popularly used colors in the conservation of oil paintings. A set of these colors was obtained form four manufacturers each, and their properties were analyzed by conducting deterioration experiments. Subsequently, we observed the colors and performed X-ray fluorescence analysis. As a result of colour observation and XRF analysis, it was confirmed that there are the differences according to the pigment types, mixing rations and the manufacturers even for colors having the same product name. The deterioration test indicated differences in the appearance of the colors ; for instance, the color difference was above 12.0 in most of the samples, including restoration color and acrylic gouache. In the case of Lemon Yellow a lot of discoloration and cracking occurred, and difference in gloss was ob served in Viridian of manufacturer C. Most cracks were ob served in the restoration color obtained from manufacturer B and were assumed to be because of the resin used by the manufacturer. Nevertheless, additional research will have to be conducted by controlling variables in order to find out the cause. Through this study, we demonstrated that retouching materials for conservation of oil painting differed in their physical properties according to the color and manufacturer. Therefore a conservator should be mindful during the selection and use of materials for retouching oil paintings.

Dental Hygienist's Harmful Factor Exposure and Recognition of Material Safety Data Sheets of Workplace Type (치과위생사의 근무기관 유형별 유해인자 노출과 물질안전보건자료 인식 연구)

  • Kim, Hae-Kyeong;Kim, Ji-Young;Oh, Na-Rae
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.11
    • /
    • pp.540-549
    • /
    • 2018
  • This study was conducted on 238 dental hygienists working in Daegu and Gyeongbuk area. In order to understand the status of harmful transmission of dental materials by type of work, we compared the differences in exposure time and work environment characteristics of hospital types and investigated the difference in the degree of recognition of material safety data. The results of the study were as follows: In case of hospitals, the exposure time of dust generated from chemicals was the longest. Resin filling, contact with disinfectant. 37 workers (29.4%) and 14 workers (12.5%) answered that they perceive the question about whether they are aware of the material safety data sheet (MSDS) for dental materials. There were 18 hospital workers and 6 clinic workers who had experience reading MSDS before using dental materials. The respondents who answered that they provided the material safety data of the dental materials used had a 2.39 times MSDS in hospital workers. Therefore, by recognizing the health hazards of chemical substances in accordance with the characteristics of each type of hospital and continuing to conduct health and safety education, the work environment should be improved by establishing proper recognition of MSDS information. It suggests the necessity of a system that can strengthen the management of chemical information provision and guarantee the strategic approach and workers' right to know.

DENTAL MANAGEMENT OF A PATIENT WITH MUSCULAR DYSTROPHY UNDER GENERAL ANESTHESIA: CASE REPORT (근이영양증(muscular dystrophy) 환자의 전신마취 하 치과치료 : 증례보고)

  • Chae, Jong Kyun;Song, Ji-Soo;Shin, Teo Jeon;Hyun, Hong-Keun;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Young-Jae
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.15 no.1
    • /
    • pp.50-54
    • /
    • 2019
  • Muscular dystrophy (MD) is a heterogeneous group of inherited neuromuscular disorders, characterized by progressive muscle weakness. Severity of the disease ranges from mild to severe, and the disease is mostly caused by mutations in a number of genes. These genetic mutations cause lack of proteins which are essential for muscle cell stability. Muscle fibers are gradually replaced by fat and fibrous tissue. The muscles of the head and neck are affected in several types of MD that manifest as altered craniofacial morphology and dental malocclusion. A 3-year-10-month old, 15.0 kg boy with MD presented to Seoul National University Dental Hospital, Seoul, South Korea because of extensive carious teeth. A number of dental caries in primary dentition were identified during clinical oral examination. Due to dental anxiety and underlying systemic disease, general anesthesia was considered. General anesthesia was induced and maintained with intravenous anesthetics, propofol and remifentanil. Caries treatments - resin restoration, pulpectomy, zirconia crown restoration, stainless steel crown restoration - were performed. Under general anesthesia, successful dental procedure was done. Total intravenous anesthesia (TIVA) was performed instead of inhalation anesthesia in order to avoid risk of complications such as malignant hyperthermia and life-threatening rhabdomyolysis. With decreasing muscle function, plaque control becomes more difficult and leads to gingivitis. Especially, the open-mouth posture worsens gingivitis and can leads to malocclusions and problems in swallowing. Regular and periodic dental care is essential for maintaining oral health for patients with MD.

Review on additive manufacturing of dental materials (치과용 재료의 적층가공에 대한 문헌고찰)

  • Won, Sun;Kang, Hyeon-Goo;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.1
    • /
    • pp.1-15
    • /
    • 2021
  • Additive manufacturing (AM) for dental materials can produce more complex forms than conventional manufacturing methods. Compared to milling processing, AM consumes less equipment and materials, making sustainability an advantage. AM can be categorized into 7 types. Polymers made by vat polymerization are the most suitable material for AM due to superior mechanical properties and internal fit compared to conventional self-polymerizing methods. However, polymers are mainly used as provisional restoration due to their relatively low mechanical strength. Metal AM uses powder bed fusion methods and has higher fracture toughness and density than castings, but has higher residual stress, which requires research on post-processing methods to remove them. AM for ceramic use vat polymerization of materials mixed with ceramic powder and resin polymer. The ceramic materials for AM needs complex post-processing such as debinding of polymer and sintering. The low mechanical strength and volumetric accuracy of the products made by AM must be improved to be commercialized. AM requires more research to find the most suitable fabrication process conditions, as the mechanical properties and surface of any material will vary depending on the processing condition.