• Title/Summary/Keyword: Resin crown

Search Result 315, Processing Time 0.026 seconds

THE EFFECT OF THICKNESS OF THE PROVISIONAL CROWN AND FIXED PARTIAL DENTURE MATERIALS ON THE TRANSLUCENCY AND MASKING EFFECT

  • Jae, Hyun-Jee;Kim, Sung-Hun;Lee, Seok-Hyung;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.724-734
    • /
    • 2007
  • Statement of problem. Translucency and masking effect of provisional crown and fixed partial denture materials is an important esthetic consideration. But, provisional resin materials differ substantially in their ability to mask underlying colors. Purpose. The purpose of this study was to evaluate the translucency differences of provisional resin materials at various thicknesses and the correlation between the translucency and the masking efficiency. Material and methods. Two polymethyl methacrylate resins (Jet Tooth Shade, Alike) and three resin composites (Protemp 3 Garant, Luxatemp and Revotek LC) were used. Specimens (n=6) were fabricated from each material in 0.3, 0.5, 0.8, 1.0, 1.5, 2.0 and 3.0 mm thickness. The CIELAB parameters of each specimens were measured using a spectrophotometer. The translucency parameter (TP) values and the masking effect $({\Delta}ME^*{_{ab}})$ values were computed and all data were statistically analyzed by one-way ANOVA and the multiple comparisons Scheffe test. The correlation between the thickness and the TP values and the correlation between the thickness and the ${\Delta}ME^*{_{ab}}$ values were also evaluated by correlation analysis and regression analysis. Results. The TP values and the ${\Delta}ME^*{_{ab}}$ values were significantly related to the thickness in all specimens. The TP values were more sensitive to the change of thickness than the ${\Delta}ME^*{_{ab}}$ values. The order of the translucency by brand was different from the order of the masking effect by brand in all thickness groups. Conclusion. Within the limitations of this study, the translucency and masking effect of the provisional resin materials investigated were significantly related to their thickness. The masking effect of provisional resin was correlated with the translucency parameter, but the order of the masking effect by brand was different from the order of the translucency parameter.

Adsorption of Metal Ions on Cryptand Synthetic Resin (Cryptand 합성수지에 위한 금속 이온들의 흡착)

  • Lee Chi-Young;Kim Joon-Tae
    • Journal of environmental and Sanitary engineering
    • /
    • v.20 no.4 s.58
    • /
    • pp.38-44
    • /
    • 2005
  • Cryptand resins were synthesized with 1-aza-15-crown-5 macrocyclic ligand attached to styrene divinylbenzene (DVB) copolymer with crosslink of $1\%,\;2\%,\;5\%\;and\;10\%$ by substitution reaction. The synthesis of these resins was confirmed by content of chlorine, element analysis, and IR-spectrum. The effects of pH, time, dielectric constant of solvent and crosslink on adsorption of uranium$(UO_2^{2+})$ ion were investigated. The uranium ion was showed fast adsorption on the resins above pH 3. The optimum equilibrium time for adsorption of metallic ions was about two hours. The adsorption selectivity determined in ethanol was in increasing order uranium$(UO_2^{2+})$ > zinc$(Zn^{2+})$ > samarium$(Sm^{3+})$ ion. The adsorption was in order of $1\%>2\%>5\%>10\%$ crosslink resin and adsorption of resin decreased in proportion to order of dielectric constant of solvents.

Adsorption Characteristic of Mg(II), Al(III), Pb(II) Metal Ions on Cryptand Ion Exchange Resin from Water Fire Extinguishing Agent (물 소화약제로부터 Cryptand 이온교환수지의 Mg(II), Al(III) 및 Pb(II) 흡착특성)

  • Kim, Joon-Tae;Kim, Kwan-Chun
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.1
    • /
    • pp.57-65
    • /
    • 2008
  • Resins were synthesized with 1-aza-15-crown-5 macrocyclic ligand attached to styrene(dangerous matter) divinylbenzene(DVB) copolymer with crosslink of 1, 2, 6 and 15% by substitution reaction. The synthesis of these resins was confirmed by content of chlorine, element analysis, and IR-spectrum. The effects of pH, time and crosslink on adsorption of metal ion from water fire extinguishing agent by the synthetic resin adsorbent were investigated. The metal ion was showed fast adsorption on the resins above pH 3. The optimum equilibrium time for adsorption of metallic ions was about two hours. The adsorption selectivity determined in water was in increasing order of $Mg^{2+}>Al^{3+}>Pb^{2+}$. The adsorption was in the order of 1, 2, 6, and 15% crosslink resin.

Comparison of fracture strength, surface hardness, and color stain of conventionally fabricated, 3D printed, and CAD-CAM milled interim prosthodontic materials after thermocycling

  • Mesut Yildirim;Filiz Aykent;Mahmut Sertac Ozdogan
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.2
    • /
    • pp.115-125
    • /
    • 2024
  • PURPOSE. The purpose of this in vitro study was to investigate the fracture resistance, surface hardness, and color stain of 3D printed, CAD-CAM milled, and conventional interim materials. MATERIALS AND METHODS. A total of 80 specimens were fabricated from auto polymerizing polymethyl methacrylate (PMMA), bis-acryl composite resin, CAD-CAM polymethyl methacrylate resin (milled), and 3D printed composite resin (printed) (n = 20). Forty of them were crown-shaped, on which fracture strength test was performed (n = 10). The others were disc-shaped specimens (10 mm × 2 mm) and divided into two groups for surface hardness and color stainability tests before and after thermal cycling in coffee solution (n = 10). Color parameters were measured with a spectrophotometer before and after each storage period, and color differences (CIEDE2000 [DE00]) were calculated. The distribution of variables was measured with the Kolmogorov Smirnov test, and one-way analysis of variance (ANOVA), Tukey HSD, Kruskal-Wallis, Mann-Whitney U tests were used in the analysis of quantitative independent data. Paired sample t-test was used in the analysis of dependent quantitative data (P < .05). RESULTS. The highest crown fracture resistance values were determined for the 3D printed composite resin (P < .05), and the lowest were observed in the bis-acryl composite resin (P < .05). Before and after thermal cycling, increase in mean hardness values were observed only in 3D printed composite resin (P < .05) and the highest ΔE00 value were observed in PMMA resin for all materials (P < .05). CONCLUSION. 3D printing and CAD-CAM milled interim materials showed better fracture strength. After the coffee thermal cycle, the highest surface hardness value was again found in 3D printing and CAD-CAM milled interim samples and the color change of the bis-acryl resin-based samples and the additive production technique was higher than the PMMA resin and CAD-CAM milled resin samples.

FRACTURE RESISTANCE OF CROWN-ROOT FRACTURED TEETH REPAIRED WITH DUAL-CURED COMPOSITE RESIN AND HORIZONTAL POSTS (수평 포스트와 이중중합 복합레진으로 수복된 치관-치근 복합파절 치아의 파절 저항성에 관한 연구)

  • Chang, Seok-Woo;Lee, Yong-Keun;Kyung, Seung-Hyun;Yoo, Hyun-Mi;Oh, Tae-Seok;Park, Dong-Sung
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.5
    • /
    • pp.383-389
    • /
    • 2009
  • The purpose of this study was to investigate the fracture resistance of crown-root fractured teeth repaired with dual-cured composite resin and horizontal posts. 48 extracted human premolars were assigned to control group and three experimental groups. Complete crown-root fractures were experimentally induced in all control and experimental teeth. In the control group. the teeth (n=12) were bonded with resin cement and endodontically treated. Thereafter, the access cavities were sealed with dual-cured composite resin. In composite resin core-post group (n=12), the teeth were endodontically treated and access cavities were sealed with dual-cured composite resin. In addition, the fractured segments in this group were fixed using horizontal posts. In composite resin core group (n=12), the teeth were endodontically treated and the access cavities were filled with dual-cured composite resin without horizontal posts. In bonded amalgam group (n = 12), the teeth were endodontically treated and the access cavities were sealed with bonded amalgam. Experimental complete crown-root fractures were induced again on repaired control and experimental teeth. The ratio of fracture resistance to original fracture resistance was analyzed with Kruskal-Wallis test. The results showed that teeth in control and composite resin core-post group showed significantly higher resistance to re-fracture than those in amalgam core group (p < 0.05). The resistance to refracture was high in the order of composite resin - post group, control group, composite resin group and bonded amalgam group. Within the scope of this study, the use of horizontal post could be beneficial in increasing the fracture resistance of previously fractured teeth.

Effect of resin cement color on the color of commercially available zirconia crown (레진시멘트 색상이 상용 지르코니아 크라운의 색상에 미치는 영향)

  • Ha, Hyeon-Seung;Lim, Bum-Soon;Rhee, Sang-Hoon
    • Korean Journal of Dental Materials
    • /
    • v.45 no.4
    • /
    • pp.233-242
    • /
    • 2018
  • The purpose of this study is to evaluate the effect of resin cement color on the color of commercially available zirconia crown. The zirconia and resin cements used for the experiment were $NuSmile^{(R)}$ ZR Zirconia LT Shade (LT), $RelyX^{TM}$ U200 TR, A2, and A3O (TR, A2, A3O). The disks of zirconia and resin cements with diameters of 5 mm and thicknesses of 1 mm were prepared. Five disks were made for each specimen. The CIE $L^*a^*b^*$ values of zirconia, resin cements and the combinations thereof were measured on black and white backgrounds, respectively, using a spectrophotometer. The color effect of resin cement on the color of the zirconia crown was evaluated by calculating translucency parameter (TP), contrast ratio (CR), and color differences (${\Delta}E{^*}_{ab}$) based on the measured CIE $L^*a^*b^*$ values. The statistical significances were verified by one-way ANOVA and the Tukey-multiple comparisons tests. As a result, the TP and CR values were decreased (p<0.05) and increased, respectively, in the combination of zirconia and resin cement disks compared to zirconia disk per se. When using the black background, the ${\Delta}E{^*}_{ab}$ values between zirconia and the combination of the zirconia and three resin cement disks were imperceptible level. The A3O showed the lowest ${\Delta}E{^*}_{ab}$ value among three resin cements. When using the white background, the ${\Delta}E{^*}_{ab}$ values between zirconia and the combination of zirconia and TR resin cement (LT/TR) disks showed acceptable level. However, the ${\Delta}E{^*}_{ab}$ values between zirconia and the combination of zirconia and A2 resin cement (LT/A2) disks showed unacceptable level. Meanwhile, the ${\Delta}E{^*}_{ab}$ values between zirconia and the combination of zirconia and A3O resin cement (LT/A3O) disks showed perceptible but acceptable level. Within the limits of this study, the colors of resin cements did not cause unacceptable color changes of zirconia except the combination of LT/A2 on the white background. The resin cement that gave the least color changes to zirconia was A3O. This means that the resin cement A3O is recommended to use for minimizing color changes when cementing commercially available zirconia crown to tooth.

The effect of ultrasonic vibration on bond strength of cemented crown according to margin types and cements (초음파 진동이 주조금관의 변연형태와 시멘트의 결합강도에 미치는 영향)

  • Lee, Yun-Kyung;Bang, Mong-Sook;Park, Ha-Ok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.3
    • /
    • pp.225-233
    • /
    • 2002
  • This study was aimed to evaluate the effects of ultrasonic vibration on margin types and cements by comparing bond strength of cemented crown. In this study, margins of each metal die, which were chamfer, shoulder and shoulder with bevel, were prepared using computer milling machine. Specimens were cemented with zinc phosphate cement or resin cement. The specimens were divided by the finish line and cement used, ultrasonic vibration. I made total 84 specimens. All specimens were divided into two groups. One group was not vibrated, the other group was subjected to ultrasonic vibration for 12 minutes. Tensile bond strength was measured using Universial testing machine. The changes of bond strength in groups were statistically analyzed by t-test or One-way ANOVA. The results were as follows : 1. Ultrasonic instrumentation diminished the bond strength of crown cemented with zinc phosphate cement and resin cement after 12 minutes application. 2. In case of zinc phosphate cement, the bond strength of a vibrated group was showed significantly decreased(p<0.05). In vibrated groups with zinc phosphate cement, shoulder with bevel exhibit a significant difference to chamfer and shoulder(p<0.05) 3. Resin cement was more resistant to ultrasonic vibration than zinc phosphate cement and showed no significant differences according to ultrasonic vibration and margin type. In conclusion, These results revealed that zinc phosphate cement was most affected and resin cement was the least affected by ultrasonic vibration. Especially shoulder with bevel design was most affected in zinc phosphate cement groups. we should consider these results and be taken in the application of ultrasonic vibration to any teeth restored with crowns.