• Title/Summary/Keyword: Resin concrete

Search Result 304, Processing Time 0.036 seconds

A Foundamental Study on Evaluation of Adhesive Strength in Reinforced Position Concrete Structure Used Fiber Sheet (섬유쉬트 보강부위의 부착성능 평가에 관한 기초연구)

  • 안상철;곽규성;이성혁;오상근;박국배;안상덕
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04b
    • /
    • pp.613-617
    • /
    • 1998
  • This study deals with the effect on adhesive strength properties of fiber sheet layer and maintenance position of coccrete structure reinforced using epoxy resin carbon and aramit fiber sheet. Properties of epoxy resin adhesive strength of the concrete bridge slab, tunnel and wall etc. reinforced using fiber sheet under many different environment change according to condition of concrete substrate, temperature, moisture, curing, cleaning, and chemical effects and so on. The purpose of this study is that it makes the estimation value of adhesive strength of concrete substrate and fiber sheet reinforcing layer penetrated epoxy resin under high temperature(9$0^{\circ}C$), chemical attack and condition of curing.

  • PDF

A Study on the Applicability of Multipurpose Functional Synthetic Resin Formworks (다목적 기능 합성수지 거푸집 현장 적용성에 관한 연구)

  • Kim, Tae-Hui;Ahn, Sung-Jin;Lee, Young-Do;Choi, Suk;Nam, Kyung-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.143-144
    • /
    • 2018
  • This study the workability of synthetic resin form was examined through field application. results there was no warping or bulging of the mold during concrete placement in the field application. Also, the concrete surface finish of synthetic resin form was better than that of euro-form.

  • PDF

A study on the Shrinkage Reduction and Strengths of Unsaturated Polyester Mortar (불포화 폴리에스테르 레진 모르타르의 수축저감 및 강도특성에 관한 연구)

  • 최낙운;최길섭;김완기;조영국;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.343-348
    • /
    • 1999
  • The purpose of this study is to evaluated the effects of added expanded polystyrene on the basic properties of UP mortar. Polyester resin mortars are prepared with expanded polystyrene ratio in styrene monomer (EPS/PS), and the ratio of total polystyrene resin to UP resin (PS/UP). And it is tested for viscosity of UP resin added PS resin, slump-flow test, working life, flexural and compressive strengths, and curing shrinkage test. From the test result, Viscosity of resin for polymer mortar increases with increasing PS content. Curing shrinkage of UP mortar is considerably smaller than that of plain UP mortar, nevertheless, reduction in the strengths is not recognized according to adding PS resin. In this study, we can obtain the optimum mix proportions of polymer mortar using PS resin.

  • PDF

Effects of Different Paints on Steel Rods Anticorrosion of Reinforced Concrete in Salt Water (해수에서 철근콘크리트의 철근 방식에 대한 도료의 효과)

  • 이신호;고재군
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.25 no.2
    • /
    • pp.67-75
    • /
    • 1983
  • The objectives of this paper were to measure the bond strengths of reinforced concrete in which the steel rods were coated with five different kinds of anticorrosion paints, and to compare their prevention effects in salt water. The paints used in the study were epoxy resin I . II . III, Z.R. P., and silicone resin, which were applied at rates recommended by the manufacturers. The bond strengths were measured on the 7-, 14-, and 28-th days after molding. Corrosion conditions of coated steel plate under fresh water, seawater, 10 % salt water, and 20% salt water, were inspected every month during four months test peoriods, respectively. The results obtained from tests are summarized as follows: 1. Paint-coating may reduce the bond strengths of reinforced concrete. Silicone resin paint showed some 20% reduction in the strength compared to those without the paint. However, the other paints seemed not to significantly affect the strength. 2. Picture analyses showed that epoxy resin I and II significantly prevented corrosion steel plates in seawater. Epoxy resin I and silicone resin coating did not do a good job in corrosion prevention. Z.R. P. paint was found to be moderate as preventive coating paint. 3. Varying soluble salt contents had little effects on the corrosion prevention of tested paints. 4. Epoxy resin I and II were found to be appropriate as a coating material to prevent the corrosion of steel rods in seawater. Z.R.P. may also be used for the purpose.

  • PDF

Adhesion Properties of Polymer Composite Materials for Concrete Repair (콘크리트 보수용 폴리머 복합재료의 접착강도 특성)

  • 지경용;연규석;이윤수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10a
    • /
    • pp.330-335
    • /
    • 1998
  • This research was conducted to evaluate the adhesion in tension of the polymer mortars for cement concrete repair. Various polymer types, binder ratios, and wet/dry conditions of the surface were considered in this study. Styrene-butadiene rubber (SBR) and ethylen vinyl acetate (EVA) used for polymer cement mortars. Epoxy resin (EP), and unsaturated polyester resin (UP) were used for polymer mertars. Adhesion in tension for the dry condition of the substrate surface was higher than that for the wet condition of the substrate surface under the same binder ratio. Therefore, in repairing concrete, the dry surface condition was effective on adhesion.

  • PDF

Experimental Studies on the Properties of Epoxy Resin Mortars (에폭시 수지 모르터의 특성에 관한 실험적 연구)

  • 연규석;강신업
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.26 no.1
    • /
    • pp.52-72
    • /
    • 1984
  • This study was performed to obtain the basic data which can be applied to the use of epoxy resin mortars. The data was based on the properties of epoxy resin mortars depending upon various mixing ratios to compare those of cement mortar. The resin which was used at this experiment was Epi-Bis type epoxy resin which is extensively being used as concrete structures. In the case of epoxy resin mortar, mixing ratios of resin to fine aggregate were 1: 2, 1: 4, 1: 6, 1: 8, 1:10, 1 :12 and 1:14, but the ratio of cement to fine aggregate in cement mortar was 1 : 2.5. The results obtained are summarized as follows; 1.When the mixing ratio was 1: 6, the highest density was 2.01 g/cm$^3$, being lower than 2.13 g/cm$^3$ of that of cement mortar. 2.According to the water absorption and water permeability test, the watertightness was shown very high at the mixing ratios of 1: 2, 1: 4 and 1: 6. But then the mixing ratio was less than 1 : 6, the watertightness considerably decreased. By this result, it was regarded that optimum mixing ratio of epoxy resin mortar for watertight structures should be richer mixing ratio than 1: 6. 3.The hardening shrinkage was large as the mixing ratio became leaner, but the values were remarkably small as compared with cement mortar. And the influence of dryness and moisture was exerted little at richer mixing ratio than 1: 6, but its effect was obvious at the lean mixing ratio, 1: 8, 1:10,1:12 and 1:14. It was confirmed that the optimum mixing ratio for concrete structures which would be influenced by the repeated dryness and moisture should be rich mixing ratio higher than 1: 6. 4.The compressive, bending and splitting tensile strenghs were observed very high, even the value at the mixing ratio of 1:14 was higher than that of cement mortar. It showed that epoxy resin mortar especially was to have high strength in bending and splitting tensile strength. Also, the initial strength within 24 hours gave rise to high value. Thus it was clear that epoxy resin was rapid hardening material. The multiple regression equations of strength were computed depending on a function of mixing ratios and curing times. 5.The elastic moduli derived from the compressive stress-strain curve were slightly smaller than the value of cement mortar, and the toughness of epoxy resin mortar was larger than that of cement mortar. 6.The impact resistance was strong compared with cement mortar at all mixing ratios. Especially, bending impact strength by the square pillar specimens was higher than the impact resistance of flat specimens or cylinderic specimens. 7.The Brinell hardness was relatively larger than that of cement mortar, but it gradually decreased with the decline of mixing ratio, and Brinell hardness at mixing ratio of 1 :14 was much the same as cement mortar. 8.The abrasion rate of epoxy resin mortar at all mixing ratio, when Losangeles abation testing machine revolved 500 times, was very low. Even mixing ratio of 1 :14 was no more than 31.41%, which was less than critical abrasion rate 40% of coarse aggregate for cement concrete. Consequently, the abrasion rate of epoxy resin mortar was superior to cement mortar, and the relation between abrasion rate and Brinell hardness was highly significant as exponential curve. 9.The highest bond strength of epoxy resin mortar was 12.9 kg/cm$^2$ at the mixing ratio of 1:2. The failure of bonded flat steel specimens occurred on the part of epoxy resin mortar at the mixing ratio of 1: 2 and 1: 4, and that of bonded cement concrete specimens was fond on the part of combained concrete at the mixing ratio of 1 : 2 ,1: 4 and 1: 6. It was confirmed that the optimum mixing ratio for bonding of steel plate, and of cement concrete should be rich mixing ratio above 1 : 4 and 1 : 6 respectively. 10.The variations of color tone by heating began to take place at about 60˚C, and the ultimate change occurred at 120˚C. The compressive, bending and splitting tensile strengths increased with rising temperature up to 80˚ C, but these rapidly decreased when temperature was above 800 C. Accordingly, it was evident that the resistance temperature of epoxy resin mortar was about 80˚C which was generally considered lower than that of the other concrete materials. But it is likely that there is no problem in epoxy resin mortar when used for unnecessary materials of high temperature resistance. The multiple regression equations of strength were computed depending on a function of mixing ratios and heating temperatures. 11.The susceptibility to chemical attack of cement mortar was easily affected by inorganic and organic acid. and that of epoxy resin mortar with mixing ratio of 1: 4 was of great resistance. On the other hand, when mixing ratio was lower than 1 : 8 epoxy resin mortar had very poor resistance, especially being poor resistant to organicacid. Therefore, for the structures requiring chemical resistance optimum mixing of epoxy resin mortar should be rich mixing ratio higher than 1: 4.

  • PDF

A Study on the Properties of Polymer Mortar Using Waste Expanded Polystyrene as a Shrinkage-Reducing Agent (수축저감제로서 발포 폴리스티렌 폐기물을 이용한 폴리머 모르터의 기초적 성질에 관한 연구)

  • 최낙운;김완기;조영국;소승영;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10a
    • /
    • pp.362-367
    • /
    • 1998
  • The purpose of this study is to examine the influences of polystyrene content and St/UP on the setting shrinkage and strengths of polymer mortar with waste expanded polystyrene resin as a shrinkage-reducing agent, and to recommend the optimum binder formulations for product of low-shrinkage polymer mortar. In this paper, polymer mortar is prepared with waste expanded polystyrene content and St/UP, and tested for setting shrinkage, flexural and compressive strengths. From the test results, irrespective of increasing of waste expanded polystyrene resin, the strengths reduction of polymer mortar with waste expanded polystyrene(EPS) resin is not recognized. And the setting shrinkage is reduced with EPS resin content. The waste expanded polystyrene resin as a shrinkage-reducing agent can be used in the same manner as commercial polystyrene resin. In this study, we can obtain the optimum mix proportions of polymer mortar using EPS resin.

  • PDF

INFLUENCE OF ROLLING LOADS BY CASTERS ON SEPARATION RESISTANCE OF SUBSTRATE CONCRETE AND SYNTHETIC RESIN FLOOR COATINGS (下地コンクリ-トと合成樹脂塗り床材の耐剝離性に及ぼす キャスタ一の走行荷重の影響)

  • Takamasa, Mikami;Choi, Soo-Kyung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.4
    • /
    • pp.73-78
    • /
    • 2003
  • In this Study, we examined the influence of characteristics of rolling loads by casters on separation resistance of substrate concrete and synthetic resin floor coating. In the experiment, we first prepared floor samples having substrate concrete of various compressive strength, surface hardness and surface configurations, then put the coated samples to the test of separation resistance with Rolling Caster Loading Machine. Three loading conditions consisted of different kinds of casters, rolling conditions, and coating materials. Consequently, we clarified that the grade of separation resistance varied widely according to the characteristics of substrate concrete and rolling loads.

A Study on the Freeze-Thaw Resistance of Porous Concrete Using Polymer (폴리머를 이용한 포러스 콘크리트의 동결융해저항성에 관한 연구)

  • Lee, Sang Tae
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.3
    • /
    • pp.17-25
    • /
    • 2006
  • To increase freeze-thaw resistance of porous concrete, this study examined physical properties of polymer by replacing paste used as a binding material with polymer, using unsaturated polyester and epoxy resin, and changing the mixing ratio of polymer. According to the result of this study, when the mixing ratio of resin paste to aggregates was 11 to 16%, voids volume was 33 to 37% and unit weight was about 1620 to 1720kg/$m^3$. In comparison with previous studies using cement paste, voids volume increased by about 7 to 16%, while unit weight decreased by about 100 to 300kg/$m^3$. Compressive strength was 90 to 155kg/$cm^2$ at the age of 7 days, which was 5-40kg/$cm^2$ bigger than porous concrete using cement paste. From a viewpoint of freeze-thaw resistance, it was identified that pluse velocity fell by 0.23km/sec, about 7% of the original velocity, when the cycle of freeze-thaw was repeated 300 times. In spite of 300 repetitions of the cycle, relative dynamic modulus of elasticity was more than 60%, which suggested that its freeze-thaw resistance was more excellent compared with the result that relative dynamic modulus of elasticity of porous concrete using cement paste was 60 % or less under the condition of 80 repetitions of freeze-thaw cycle.

Properties of Strength and Stress-Strain of Recycled-Plastic Polymer Concrete (폐플라스틱 재활용 폴리머콘크리트의 강도와 응력-변형률 특성)

  • Jo Byung-Wan;Koo Jakap;Park Seung-Kook
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.3 s.87
    • /
    • pp.329-334
    • /
    • 2005
  • The use of Polymer Concrete (PC) is growing very rapidly in many structural and construction applications such as box culverts, hazardous waste containers, trench lines, floor drains and the repair and overlay of damaged cement concrete surfaces in pavements, bridges, etc. However, PC has a defect economically because resin which be used for binder is expensive. Therefore the latest research is being progressed to replace existing resin with new resin which can reduce the high cost. Here, Polymer concrete using the recycled PET(polyethylene terephthalate) has some merits such as decrease of environmental destruction, decrease of environmental pollution and development of new construction materials. The variables of this study are amount of resin, curing condition and maximum size of coarse aggregate to find out mechanic properties of this. Stress-strain curve was obtained using MTS equipment by strain control. The results indicated that modulus of elasticity was increased gradually in an ascending branch of curve, as an increase of resin content. Compressive strength was the highest for resin content of $13\%$. And Compressive strength was increased as maximum size of coarse aggregate increases. The strain at maximum stress increases with an increase of resin content and size of coarse aggregate. For the descending branch of stress-strain curve the brittle fracture was decreased when it was cured at the room temperature compared to high temperature.