• 제목/요약/키워드: Resin cement shade

검색결과 17건 처리시간 0.018초

Curing efficiency of various resin-based materials polymerized through different ceramic thicknesses and curing time

  • Lee, Jung-Won;Cha, Hyun-Suk;Lee, Joo-Hee
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권3호
    • /
    • pp.126-131
    • /
    • 2011
  • PURPOSE. The aim of this in vitro study was to examine the curing efficiency of various resin-based materials polymerized through ceramic restorations with 3 different thicknesses. Curing efficiency was evaluated by determining the surface microhardness (VHN) of the resin specimens. MATERIALS AND METHODS. Four kinds of resin materials were used. Z350 (3M ESPE $Filtek^{TM}$ Z350: A2 Shade), Z250 (3M ESPE $Filtek^{TM}$ Z250: A2 Shade) and $Variolink^{(R)}$ II (VL: Ivoclar vivadent, base: transparent) either with or without a self-curing catalyst (VLC: Ivoclar vivadent, catalyst: low viscosity/transparent) were filled into the silicone mold (10 mm diameter, 1 mm thick). They were cured through ceramic discs (IPS e.max Press MO-0 ingot ivoclar vivadent, 10 mm diameter, 0.5, 1 and 2 mm thicknesses) by LED light-curing units for 20 and 40 seconds. Vicker's microhardness numbers (VHNs) were measured on the bottom surfaces by a microhardness tester. Data were analyzed using a 3-way analysis of variance (ANOVA) at a significance level of 0.05. RESULTS. The thickness of ceramic disc increased, the VHNs of all four resin types were decreased (P<.05). The mean VHN values of the resins light cured for 40 seconds were significantly higher than that of LED for 20 seconds in all four resin materials (P<.05). VLC showed significantly higher VHN values than VL regardless of other conditions (P<.05). Z350 and Z250 showed higher values than VL or VLC (P<.01). CONCLUSION. Thinner ceramic disc with increased curing time resulted higher VHN values of all resin materials. The use of a catalyst produced a greater hardness with all polymerization methods. Restorative resin materials (Z350, Z250) showed higher VHN values than resin cement materials (VL, VLC).

Effect of Accelerated Aging on the Color Stability of Dual-Cured Self-Adhesive Resin Cements

  • Kim, Ah-Rang;Jeon, Yong-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • Journal of Korean Dental Science
    • /
    • 제8권2호
    • /
    • pp.49-56
    • /
    • 2015
  • Purpose: The effect of accelerated aging on color stability of various dual-cured self-adhesive resin cements were evaluated in this study. Materials and Methods: Color stability was examined using three different brands of dual-cured self-adhesive resin cements: G-CEM LinkAce (GC America), MaxCem Elite (Kerr), and PermaCem 2.0 (DMG) with the equivalent color shade. Each resin cement was filled with Teflon mold which has 6 mm diameter and 2 mm thickness. Each specimen was light cured for 20 seconds using light emitting diode (LED) light curing unit. In order to evaluate the effect of accelerated aging on color stability, color parameters (Commission Internationale de l'Eclairage, CIE $L^*$, $a^*$, $b^*$) and color differences (${\Delta}E^*$) were measured at three times: immediately, after 24 hours, and after thermocycling. The $L^*$, $a^*$, $b^*$ values were analyzed using Friedman test and ${\Delta}E^*$ values on the effect of 24 hours and accelerated aging were analyzed using t-test. These values were compared with the limit value of color difference (${\Delta}E^*=3.7$) for dental restoration. One-way ANOVA and Scheff's test (P<0.05) were performed to analyze each ${\Delta}E^*$ values between cements at each test period. Result: There was statistically significant difference in comparison of color specification ($L^*$, $a^*$, $b^*$) values after accelerated aging except $L^*$ value of G-CEM LinkAce (P<0.05). After 24 hours, color difference (${\Delta}E^*$) values were ranged from 2.47 to 3.48 and $L^*$ values decreased and $b^*$ values increased in all types of cement and MaxCem Elite had high color stability (P<0.05). After thermocycling, color change's tendency of cement was varied and color difference (${\Delta}E^*$) values were ranged from 0.82 to 2.87 and G-CEM LinkAce had high color stability (P<0.05). Conclusion: Color stability of dual-cured self-adhesive resin cements after accelerated aging was evaluated and statistically significant color changes occurred within clinically acceptable range.

금속 다우엘코어에 사용된 수종의 전부도재관의 색조변화에 관한 연구 (A STUDY THE SHADE CHANCE OF SEVERAL KINDS OF ALL CERAMIC CROWNS USED FOR METAL DOWEL CORE)

  • 허성일;임헌송;임주환;조인호
    • 대한치과보철학회지
    • /
    • 제39권5호
    • /
    • pp.477-491
    • /
    • 2001
  • The purpose of this study is to compare and analyze the shade changes(${\Delta}E^*$) about $In-Ceram^{(R)}$, $IPS-Empress^{(R)}$, $OPC^{(R)}$ by using of the spectrophotometer arising from inital status and before and after cementation of the resin cement mounted on the metal core. We used a couple of statistics such as 'One- Way ANOVA' and 'Multiple Range Test.' We could be able to verify significantly what is being discussed here up to 95%. The results drawn from our research are as follows : 1. At the time of our experiments regarding the initial shapes of all-ceramic and mounting status of all-ceramic on the metal crown(${\Delta}E^*1$), and a comparison of mounting of all ceramic on the metal crown with all-ceramic cemented on the metal core(${\Delta}E^*2$), at the time of shade change of initial shapes and after we cemented on the metal core. (1) no significant difference among all-ceramics was found. (2) no particular difference was found regarding the $In-Ceram^{(R)}$. (3) a significant difference between the ${\Delta}E^*1$ and ${\Delta}E^*2$ regarding the $IPS-Empress^{(R)}$ was found(P<0.05). (4) a significant difference between the ${\Delta}E^*1$ and ${\Delta}E^*2$ regarding the $OPC^{(R)}$ was found(P<0.05). 2. When we compared the shade changes(${\Delta}E^*$) resulted from before and after the cementation on each of the parts involved of some all-ceramic, we could be able to find shade change increase form incisal third, middle third. and cervical third in that order in $In-Ceram^{(R)}$(spinell), IPS $Empress^{(R)}$, and $OPC^{(R)}$ all. In addition. we could be able to find a significant difference between cervical third and incisal third, middle third. (P<0.05) From what we have just seen, we might conclude that there is a significant shade change difference before and after the cementation with respect to $IPS-Empress^{(R)}$ and $OPC^{(R)}$. In addition, we could also be able to find more shade change difference at the cervical third rather than incisal third and middle third depending on the parts involved.

  • PDF

Effect of cement type, luting protocol, and ceramic abutment material on the shade of cemented titanium-based lithium disilicate crowns and surrounding peri-implant soft tissue: a spectrophotometric analysis

  • Peter Gehrke;Maria Julia Pietruska;Johannes Ladewig;Carsten Fischer;Robert Sader;Paul Weigl
    • The Journal of Advanced Prosthodontics
    • /
    • 제16권4호
    • /
    • pp.231-243
    • /
    • 2024
  • PURPOSE. The objective of the study was to analyze the impact of cement, bonding pretreatment, and ceramic abutment material on the overall color results of CAD-CAM ceramic crowns bonded to titanium-based hybrid abutments. MATERIALS AND METHODS. For single implant restoration of a maxillary lateral incisor a total of 51 CAD-CAM-fabricated monolithic lithium disilicate crowns were fabricated and subsequently bonded onto 24 lithium disilicate Ti-base abutments, 24 zirconia Ti-base abutments and 3 resin abutment replicas as a control group. The 48 copings were cemented with three definitive and one provisional cement on both grit-blasted and non-blasted Ti-bases. The color of each restoration and surrounding artificial gingiva was measured spectrophotometrically at predefined measuring points and the CIELAB (ΔEab) color scale values were recorded. RESULTS. The color outcome of ceramic crowns bonded to hybrid abutments and soft tissues was affected differently by cements of different brands. Grit-blasting of Ti-bases prior to cementing CAD-CAM copings affected the color results of allceramic crowns. There was a significant difference (P = .038) for the median ΔE value between blasted and non-blasted reconstructions at the cervical aspect of the crown. Full-ceramic crowns on zirconia Ti-base abutments exhibited significantly lower ΔE values below the threshold of visibility (ΔE 1.8). In all subcategories tested, the use of a highly opaque temporary cement demonstrated the lowest median ΔE for both the crown and the artificial gingiva. CONCLUSION. Various cements, core ceramic materials and airborne particle abrasion prior to bonding can adversely affect the color of Ti-base supported ceramic crowns and peri-implant soft tissue. However, zirconia CAD-CAM copings and an opaque cement can effectively mask this darkening.

How will surface treatments affect the translucency of porcelain laminate veneers?

  • Turgut, Sedanur;Bagis, Bora;Ayaz, Elif Aydogan;Korkmaz, Fatih Mehmet;Ulusoy, Kivanc Utku;Bagis, Yildirim Hakan
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권1호
    • /
    • pp.8-13
    • /
    • 2014
  • PURPOSE. The purpose of this study was to evaluate whether surface treatments affect the translucency of laminate veneers with different shades and thicknesses. MATERIALS AND METHODS. A total of 224 disc-shaped ceramic veneers were prepared from A1, A3, HT (High Translucent) and HO (High Opaque) shades of IPS e.max Press (Ivoclar Vivadent) with 0.5 mm and 1.0 mm thicknesses. The ceramics were divided into four groups for surface treatments. Group C: no surface treatments; Group HF: etched with hydrofluoric acid; Group SB: sandblasted with 50-${\mu}m$ $Al_2O_3$; and Group L; irradiated with an Er;YAG laser. A translucent shade of resin cement (Rely X Veneer, 3M ESPE) was chosen for cementation. The color values of the veneers were measured with a colorimeter and translucency parameter (TP) values were calculated. A three-way ANOVA with interactions for TP values was performed and Bonferroni tests were used when appropriate (${\alpha}=0.05$). RESULTS. There were significant interactions between the surface treatments, ceramic shades and thicknesses (P=.001). For the 0.5-mm-thick specimens there were significant differences after the SB and L treatments. There was no significant difference between the HF and C treatments for any shades or thicknesses (P>.05). For the 1-mm-thick ceramics, there was only a significant difference between the L and C treatments for the HT shade ceramics (P=.01). There were also significant differences between the SB and C treatments except not for the HO shades (P=.768). CONCLUSION. The SB and L treatments caused laminate veneers to become more opaque; however, HF treatment did not affect the TP values. When the laminate veneers were thinner, both the shade of the ceramic and the SB and laser treatments had a greater effect on the TP values.

초기 방습이 글래스아이오노머 시멘트의 색안정성 및 투명도 변화에 미치는 영향 (Effect of Early Waterproof on Color Stability and Translucency Change of Glass-ionomer Cement)

  • 정선와;김선헌;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제19권1호
    • /
    • pp.124-134
    • /
    • 1994
  • The shade of restorative materials is very important for successful restoration esthetically harmonized with the natural tooth. The purpose of this study was to evaluate the color stability and the opacity change of conventional chemical setting and visible light curing glass-ionomer cements for restorative esthetic filling. Specimens of each brand (GC Fuji II and Fuji II LC) were uniformly prepared and divided into three groups: In group l(control group), the specimens received no surface treatment; in group 2, the specimens were coated with varnish and the excess gently blown off; and in group 3. the specimens were coated with light-cured bonding resin and irradiated by a visible light curing unit for 20 seconds on both sides. All specimens were stored in distilled water at $37^{\circ}C$ and checked after for 24 hours. 2 months. 4 months, 6 months. and 8 months. The color characteristics($L^*,\;a^*,\;b^*$) and the opacity(Y%) of all the samples were measured by a spectrocolorimeter and the total color differences(${\Delta}E^*$) and opacity changes(${\Delta}Y%$) were computed. The following results were obtained : 1. The total tolor differences in all groups increased with time. 2. The total color differences of the LC groups after immersion for 8 months in distilled water at $37^{\circ}C$ were lower than those of GC groups(p<0.01), and the total color differences of the varnish or the light-cured bonding resin coated groups were lower than those of the control group with glass-ionomer cements which had no surface treatment(p<0.01). 3. In all groups the translucency decreased with time. 4. In the control group and the varnish coating group. the opacity changes of the GC groups were lower than those of the LC groups(p<0.01) and in the light-cured bonding resin coated group, there was no significant difference between the GC group and the LC group. 5. The opacity changes of the varnish or the light-cured bonding resin coated groups were lower than those of the control group(p<0.01). These results suggest that color change and opacity of conventional chemical setting and light cured glass-ionomer cement were increased with time, and the color changes and the opacity changes of a control group after immersion for 8 months in distilled water at $37^{\circ}C$ were greater than those of the varnish or the light-cured bonding resin coated groups.

  • PDF

수종의 접착제를 이용한 Targis와 상아질간의 전단결합강도 (SHEAR BOND STRENGTH BETWEEN TARGIS AND HUMAN DENTIN BY USING VARIOUS LUTING CEMEMTS)

  • 이정;유미경;조영곤;이강원
    • Restorative Dentistry and Endodontics
    • /
    • 제24권3호
    • /
    • pp.519-527
    • /
    • 1999
  • The purpose of this study was to estimate shear bond strength according to difference in luting cements and Targis surface treatment. 70 non-carious extracted human molars and Targis shade D210(Ivoclar, Liechtenstein) were used in the present study and they were randomly assigned into 7 experimental groups ; Group 1 : specimens were bonded with using vitremer(3M, U.S.A). Group 2, 4, 6 : specimens were not-treated with silane and bonded with Panavia 21(Kuraray Japan), Choice(Bisco, U.S.A.) and Variolink II(Vivadent, Liechtenstein) respectively Group 3, 5, 7 : specimens were treated with silane and bonded with Panavia 21, Choice and Variolink II respectively. After the surface treatment, the luting cement was mixed by manufacturer's recommendation and then applied between dentin and Targis and excess cement was removed by brush. All specimens were stored for 24 hrs in distiled water at $37^{\circ}C$. Shear bond strength for each group was then measured. To examine the failure patterns of targis to dentin, specimens were fabricated and observed under the SEM. The results were as follows ; 1. The mean shear bond strength of the groups using resin cements was significantly higher than that using resin-modified GI cements (P<0.05). 2. There is no significant difference in shear bond strength between Panavia 21 and Choice whether silane was used or not(P>0.05). However, bond strength for the groups using Variolink II was higher in the specimens not-treated with silane than the treated specimens (P<0.05). 3. There is no significant difference in bond strength among the groups using silane surface treatment and resin cement (group 3, 5, 7) (P<0.05). 4. The proportions of the specimens showing the mixed fracture failure were 20% in groups using Panavia 21 and Variolink II and 15% in group using Choice.

  • PDF