• Title/Summary/Keyword: Residual Test

Search Result 1,816, Processing Time 0.03 seconds

Residual Characteristics of Some Pyrethroid Insecticides in Korean Cabbage (Pyrethroid계 살충제의 배추 중 잔류특성)

  • Kim, Dae-Kyu;Kim, Joo-Kwang;Lee, Eun-Young;Park, In-Young;Noh, Hyun-Ho;Park, Young-Soon;Kim, Tae-Hwa;Jin, Chung-Woo;Kim, Kwang-Ill;Yun, Sang-Soon;Oh, Sang-Kyun;Kyung, Kee-Sung
    • The Korean Journal of Pesticide Science
    • /
    • v.11 no.3
    • /
    • pp.154-163
    • /
    • 2007
  • In order to elucidate the residual characteristics of some pyrethroid insecticides commonly used for Korean cabbage, such as bifentbrin, lambda-cyhalothrin and deltametbrin, the test pesticides were sprayed onto the crop at recommended rate and doubled rate of the recommendation. Their detection limits were 0.004 mg $kg^{-1}$ and mean recoveries at the fortification levels of 0.04 and 0.2 mg $kg^{-1}$ were from 95.16 to 99.32 and from 86.81 to 103.73%, respectively. Half-lives were from 2.5 to 3.6 at the recommended rate and from 2.3 to 3.9 days at the doubled rate of the recommendation. Initial residue amounts of bifenthrin and lambda-cyhalothrin at the recommended rate and doubled rate of recommendation and of deltamethrin at the recommended rate were less than their MRL, whereas, in case of deltamethrin sprayed at doubled rate of the recommendation, the residue level exceeded its MRL. However, the residue levels of the pesticides in the crop sampled at harvest were less than their maximum residue levels and the ratios of the estimated daily intake (EDI) to acceptable daily intake (ADI) for the pesticides tested calculated from the residue data at harvest were less than 7%, suggesting that these pesticides would be safe for Korean cabbage from the residue concern.

The Effect of Carbon Dioxide Leaked from Geological Storage Site on Soil Fertility: A Study on Artificial Leakage (지중 저장지로부터 누출된 이산화탄소가 토양 비옥도에 미치는 영향: 인위 누출 연구)

  • Baek, Seung Han;Lee, Sang-Woo;Lee, Woo-Chun;Yun, Seong-Taek;Kim, Soon-Oh
    • Economic and Environmental Geology
    • /
    • v.54 no.4
    • /
    • pp.409-425
    • /
    • 2021
  • Carbon dioxide has been known to be a typical greenhouse gas causing global warming, and a number of efforts have been proposed to reduce its concentration in the atmosphere. Among them, carbon dioxide capture and storage (CCS) has been taken into great account to accomplish the target reduction of carbon dioxide. In order to commercialize the CCS, its safety should be secured. In particular, if the stored carbon dioxide is leaked in the arable land, serious problems could come up in terms of crop growth. This study was conducted to investigate the effect of carbon dioxide leaked from storage sites on soil fertility. The leakage of carbon dioxide was simulated using the facility of its artificial injection into soils in the laboratory. Several soil chemical properties, such as pH, cation exchange capacity, electrical conductivity, the concentrations of exchangeable cations, nitrogen (N) (total-N, nitrate-N, and ammonia-N), phosphorus (P) (total-P and available-P), sulfur (S) (total-S and available-S), available-boron (B), and the contents of soil organic matter, were monitored as indicators of soil fertility during the period of artificial injection of carbon dioxide. Two kinds of soils, such as non-cultivated and cultivated soils, were compared in the artificial injection tests, and the latter included maize- and soybean-cultivated soils. The non-cultivated soil (NCS) was sandy soil of 42.6% porosity, the maize-cultivated soil (MCS) and soybean-cultivated soil (SCS) were loamy sand having 46.8% and 48.0% of porosities, respectively. The artificial injection facility had six columns: one was for the control without carbon dioxide injection, and the other five columns were used for the injections tests. Total injection periods for NCS and MCS/SCS were 60 and 70 days, respectively, and artificial rainfall events were simulated using one pore volume after the 12-day injection for the NCS and the 14-day injection for the MCS/SCS. After each rainfall event, the soil fertility indicators were measured for soil and leachate solution, and they were compared before and after the injection of carbon dioxide. The results indicate that the residual concentrations of exchangeable cations, total-N, total-P, the content of soil organic matter, and electrical conductivity were not likely to be affected by the injection of carbon dioxide. However, the residual concentrations of nitrate-N, ammonia-N, available-P, available-S, and available-B tended to decrease after the carbon dioxide injection, indicating that soil fertility might be reduced. Meanwhile, soil pH did not seem to be influenced due to the buffering capacity of soils, but it is speculated that a long-term leakage of carbon dioxide might bring about soil acidification.

Monitoring of Residual Pesticides and Exposure Assessment of Olive Oil Products Sold on the Market (올리브유의 잔류농약 모니터링 및 노출량 조사)

  • Mi-Hui Son;Jae-Kwan Kim;You-Jin Lee;Ji-Eun Kim;Eun-Jin Baek;Byeong-Tae Kim;Seong-Nam Lee;Myoung-Ki Park;Yong-Bae Park
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.4
    • /
    • pp.211-216
    • /
    • 2023
  • A total of 100 commercially available olive oil products were analyzed for 179 pesticide residues using gas chromatography-tandem mass spectrometry (GC/MS/MS). The olive oil samples were mixed with organic solvents, centrifuged and frozen to remove fat, and pesticide residues were analyzed using the "quick, easy, cheap, effective, rugged, and safe" (QuEChERS) method. The determination coefficient (R2) of the analysis method used in this study was ≥0.998. The detection limit of the method ranged 0.004-0.006 mg/kg and its quantitative limit ranged 0.012-0.017 mg/kg. The recovery rate (n=5) measured at the level ranging 0.01-0.02, 0.1, and 0.5 mg/kg ranged 66.8-119.5%. The relative standard deviation (RSD) was determined to be ≤5.7%, confirming that this method was suitable for the "Guidelines for Standard Procedures for Preparing Food Test Methods". The results showed that a total of 151 pesticides (including difenoconazole, deltamethrin, oxyfluorfen, kresoxim-methyl, phosmet, pyrimethanil, tebuconazole, and trifloxystrobin) were detected in 64 of the 100 olive oil products. The detection range of these pesticide residues was 0.01-0.30 mg/kg. The percentage acceptable daily intake (%ADI) of the pesticides calculated using ADI and estimated daily intake (EDI) was 0.0001-0.1346, indicating that the detected pesticides were present at safe levels. This study provides basic data for securing the safety of olive oil products by monitoring pesticide residues in commercially available oilve oil products. Collectively, the analysis method used in this study can be used as a method to analyze residual pesticides in edible oils.

A Study on Replay Experiments and Thermal Analysis for Autoignition Phenomenon of Shredded Waste Tires (폐타이어 분쇄물의 자연발화현상에 대한 재연실험 및 열분석에 관한 연구)

  • Koh, Jae Sun;Jang, Man Joon
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.99-108
    • /
    • 2012
  • These days, spontaneous ignition phenomena by oxidizing heat frequently occur in the circumstances of processing and storing waste tires. Therefore, to examine the phenomena, in this work, this researcher conducted the tests of fires of fragmented waste tires (shredded tire), closely investigated components of the fire residual materials collected in the processing and storing place, and analyzed the temperature of the starting of the ignition, weight loss, and heat of reaction. For the study, this researcher conducted fire tests with fragmented waste tires in the range of 2.5 mm to 15 mm, whose heat could be easily accumulated, and performed heat analysis through DSC and TGA, DTA, DTG, and GC/MS to give scientific probability to the possibility of spontaneous ignition. According to the tests, at the 48-hour storage, rapid increase in temperature ($178^{\circ}C$), Graphite phenomenon, smoking were observed. And the result from the DTA and DTG analysis showed that at $166.15^{\circ}C$, the minimum weight loss occurred. And, the result from the test on the waste tire analysis material 1 (Unburnt) through DSC and TGA analysis revealed that at $180^{\circ}C$ or so, thermal decomposition started. As a result, the starting temperature of ignition was considered to be $160^{\circ}C$ to $180^{\circ}C$. And, at $305^{\circ}C$, 10 % of the initial weight of the material reduced, and at $416.12^{\circ}C$, 50 % of the intial weight of the material decreased. The result from the test on oxidation and self-reaction through GC/MS and DSC analysis presented that oxidized components like 1,3 cyclopentnadiene were detected a lot. But according to the result from the heat analysis test on standard materials and fragmented waste tires, their heat value was lower than the basis value so that self-reaction was not found. Therefore, to prevent spontaneous ignition by oxidizing heat of waste tires, it is necessary to convert the conventional process into Cryogenic Process that has no or few heat accumulation at the time of fragmentation. And the current storing method in which broken and fragmented materials are stored into large burlap bags (500 kg) should be changed to the method in which they are stored into small burlap bags in order to prevent heat accumulation.

Arthroscopic Double-Bundle Reconstruction of Anterior Cruciate Ligament (관절경을 이용한 전방 십자 인대의 이중 다발 재건술)

  • Jung, Young-Bok;Park, Se-Jin;Jung, Ho-Joong;Yoo, Jae-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.11 no.2
    • /
    • pp.92-98
    • /
    • 2007
  • Purposes: The purpose of this study was to report surgical technique of double bundle anterior cruciate ligament(ACL) reconstruction and to compare the short-term clinical results between arthroscopic single-bundle and double-bundle ACL reconstruction. Materials and Methods: From May 2005 to May 2006, ninety-eight patients were underwent ACL reconstruction. We designed prospective study with sixty-one patients who were revealed isolated ACL injury. We serially checked clinical and radiologic data preoperatively and postoperatively. We compared single-bundle with double-bundle ACL reconstruction patients with preoperative datas and postoperatively 1-year data. There were 30 single bundle reconstruction and 31 double bundle reconstruction. Stability was assessed objectively by anterior stress radiographs with the $Telos^{(R)}$ device and the maximal manual test with the KT-2000 arthrometer. The clinical results were assessed by IKDC(International Knee Documentation Committee) and OAK(Orthopadische Arbeitsgruppe Knie) scores. Also, we evaluated postoperative thigh circumference and range of motion. All of operations were done by only one surgeon. Results: At single-bundle reconstruction group, preoperative AP instability which was checked by $Telos^{(R)}$ device and the maximal manual test with the KT-2000 arthrometer was $7.9{\pm}3.3$ and $7.4{\pm}2.0$, respectively. At double-bundle reconstruction group, it was $8.3{\pm}3.5$ and $7.9{\pm}3.2$, respectively. Residual AP laxity checked at 1 year after operation was $1.9{\pm}1.2$ and $2.2{\pm}1.6$ in single-bundle reconstruction group, and $1.1{\pm}0.9$ and $1.0{\pm}1.0$ in double-bundle reconstruction group. So, double-bundle reconstruction had better results in both anterior stress radiographs with the $Telos^{(R)}$ device and the maximal manual test with the KT-2000 arthrometer, and there were significant differences in statistics. But, clinical results such as IKDC(International Knee Documentation Committee) scores, OAK(Orthopadische Arbeitsgruppe Knie) scores, thigh circumference and range of motion had no significant difference between two groups. Conclusions: On the basis of stability, the side-to-side anterior laxity of double-bundle ACL reconstruction was significantly better than that of single-bundle reconstruction, although there were no significant differences in the other clinical measures among them.

  • PDF

A Study of The Correlation of The Area Dose with Residual CT Contrast Media and MRI Contrast Media during The Use of General Imaging Automatic Exposure Control System (일반촬영 자동노출제어장치 사용 시 잔존 CT 조영제와 MRI 조영제에 따른 면적선량의 상관성 연구)

  • Hong, Chan-Woo;Park, Jin-Hun;Lee, Jung-Min;Seo, Young-Deuk
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.619-627
    • /
    • 2016
  • The purpose of this study is to investigate the effect of CT contrast agent and MRI contrast agent on the area dose in the body when using automatic exposure control system in general radiography. After making rectangular holes in the center of the abdominal thickness paraffin phantom, CT contrast agent and MRI contrast agent were respectively diluted with physiological saline solution for contrast medium dilution ratio of 10:0, 9:1, 8:2, 7:3, 6:4, 5:5, 4:6, 3:7, 2:8, 1:9, 0:10%. Each experiment was set to 78 kVp, 320 mA, which is the proper condition for KUB photography, and thereafter a total of 30 inspections were made for each dilution ratio using an automatic exposure control device, and the area dose corresponding to the dilution ratio of each contrast agent, Average comparison and correlation analysis were performed on the exposure index. As a result, the CT contrast agent and the MRI contrast agent appeared different in area dose according to the dilution ratio(p<0.05), and as the dilution ratio increased, the area dose increased for CT contrast agent and MRI contrast agent(P<0.05). In each test, the exposure index showed the manufacturer's recommendation of 200-800 EI value, and the exposure index and area dose increased as the area dose increased(p<0.05). In conclusion, CT contrast agent and MRI contrast agent confirmed to increase the area dose by general imaging test using all automatic exposure control device. Therefore, it is considered that it is necessary to perform it after the contrast medium has been excreted sufficiently when using usual imaging test after using the contrast agent in CT and MRI examination.

Postoperative Radiotherapy in Malignant Tumors of the Parotid Gland (이하선 악성종양의 수술 후 방사선 치료)

  • Chung Woong-Ki;Ahn Sung Ja;Nam Taek Ken;Chung Kyung-Ae;Nah Byung Sik
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.251-258
    • /
    • 1998
  • Purpose : This study was performed to analyze the factors affecting local control in malignant tumors of the parotid gland treated with surgery and postoperative radiation. Materials and methods : Twenty-six patients were treated for malignant tumors of the parotid gland from 1986 to 1995 at Department of Therapeutic Radiology, Chonnam University Hospital. Age of the patients ranged from 14 to 72 years (median : 55 years). Histologically 10 patients of mucoepidermoid carcinoma, 7 of squamous cell carcinoma, 4 of acinic cell carcinoma, 4 of adenoid cystic carcinoma and 1 of adenocarcinoma were treated. Total parotidectomy was performd in 15 of 26 patients, superficial in 7, subtotal in 4. Facial nerve was sacrificed in 5 patients. Postoperatively 4 patients had residual disease, 4 had positive resection margin. Radiation was delivered through an ipsilateral wedged pair of photon in 11 patients. High energy electron beam was mixed with photon in 15 patients. Electron beam dose ranged from 900 cGy to 3800 cGy (median 1700 cGy). Total radiation dose ranged from 5000 cGy to 7560 cGy (median : 6020 cGy). Minimum follow-up period was 2 years. Local control and survival rate were calculated using Kaplan-Meier method. Generalized Wilcoxon test and Cox proportional hazard model were used to test factors affecting local control. Results : Five (19$\%$) of 26 patients had local recurrence. Five year local control rate was 77$\%$. Overall five year survival rate was 70$\%$. Sex, age, tumor size, surgical involvement of cervical lymph node, involvement of resection margin, surgical invasion of nerve, and total dose were analyzed as suggested factors affecting local control rate. Among them patients with tumor size less than 4 cm (p=0.002) and negative resection margin (p=0.011) were associated with better local control rates in univariate analysis. Multivariate analysis showed only tumor size factor is associated with local control rate (p=0.022). Conclusion : This study suggested that tumor size is important in local control of malignant tumors of parotid gland.

  • PDF

GF/PC Composite Filament Design & Optimization of 3D Printing Process and Structure for Manufacturing 3D Printed Electric Vehicle Battery Module Cover (전기자동차 배터리 모듈 커버의 3D 프린팅 제작을 위한 GF/PC 복합소재 필라멘트 설계와 3D 프린팅 공정 및 구조 최적화)

  • Yoo, Jeong-Wook;Lee, Jin-Woo;Kim, Seung-Hyun;Kim, Youn-Chul;Suhr, Jong-Hwan
    • Composites Research
    • /
    • v.34 no.4
    • /
    • pp.241-248
    • /
    • 2021
  • As the electric vehicle market grows, there is an issue of light weight vehicles to increase battery efficiency. Therefore, it is going to replace the battery module cover that protects the battery module of electric vehicles with high strength/high heat-resistant polymer composite material which has lighter weight from existing aluminum materials. It also aims to respond to the early electric vehicle market where technology changes quickly by combining 3D printing technology that is advantageous for small production of multiple varieties without restrictions on complex shapes. Based on the composite material mechanics, the critical length of glass fibers in short glass fiber (GF)/polycarbonate (PC) composite materials manufactured through extruder was derived as 453.87 ㎛, and the side feeding method was adopted to improve the residual fiber length from 365.87 ㎛ and to increase a dispersibility. Thus, the optimal properties of tensile strength 135 MPa and Young's modulus 7.8 MPa were implemented as GF/PC composite materials containing 30 wt% of GF. In addition, the filament extrusion conditions (temperature, extrusion speed) were optimized to meet the commercial filament specification of 1.75 mm thickness and 0.05 mm standard deviation. Through manufactured filaments, 3D printing process conditions (temperature, printing speed) were optimized by multi-optimization that minimize porosity, maximize tensile strength, and printing speed to increase the productivity. Through this procedure, tensile strength and elastic modulus were improved 11%, 56% respectively. Also, by post-processing, tensile strength and Young's modulus were improved 5%, 18% respectively. Lastly, using the FEA (finite element analysis) technique, the structure of the battery module cover was optimized to meet the mechanical shock test criteria of the electric vehicle battery module cover (ISO-12405), and it is satisfied the battery cover mechanical shock test while achieving 37% lighter weight compared to aluminum battery module cover. Based on this research, it is expected that 3D printing technology of polymer composite materials can be used in various fields in the future.

Stabilization of As Contaminated Soils using a Combination of Hydrated Lime, Portland Cement, FeCl3·6H2O and NaOH (소석회, 포틀랜드 시멘트, FeCl3·6H2O, NaOH를 이용한 비소 오염토양의 안정화)

  • Moon, Deok-Hyun;Oh, Da-Yeon;Lee, Seung-Je;Park, Jeong-Hun
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.1
    • /
    • pp.47-53
    • /
    • 2010
  • The purpose of this study was to investigate the effectiveness of a stabilization treatment for As contaminated soil. A combination of hydrated lime, Portland cement, $FeCl_3{\cdot}6H_2O$, and NaOH were used as stabilizing agents. The effectiveness of stabilization treatment was evaluated by the Korean Standard Test (KST) method (1N HCl extraction). Sequential extractions were performed to investigate the As distribution after treatment. Following the application of the treatment, curing periods of up to 7 and 28days were investigated. The experimental results showed that a combination of hydrated lime/Portland cement was more effective than treatments of hydrated lime or Portland cement at immobilizing As in the contaminated soil. The treatment of 25wt% hydrated lime and 5wt% Portland cement was effective in reducing As leachability less than the Korean warning standard of 20 mg/kg. However, the treatments of hydrated lime and Portland cement failed to meet the Korean warning standard even when up to 30 wt% was used. The treatment utilizing hydrated lime and $FeCl_3{\cdot}6H_2O$ was not effective in properly reducing As leachability. The addition of $FeCl_3{\cdot}6H_2O$ was negative in terms of pH condition. Moreover, the treatment with hydrated lime/NaOH was effective in reducing As leachability but not as much as hydrated lime/Portland cement. The sequential extraction results indicated that the residual phase was greatly increased upon the treatment of hydrated lime/Portland cement. It was concluded that the hydrated lime/Portland cement treatment was the best among the other combinations studied at achieving trace As concentrations.

Water Quality Management of Simple Piped Water Supply System and Its Satisfaction of the Residents (簡易上水道의 水質管理實態와 給水利用住民의 滿足度)

  • Chae, Han-Uk;Park, Jae-Yong;Moon, Hyo-Jung
    • Journal of Environmental Health Sciences
    • /
    • v.25 no.3
    • /
    • pp.13-22
    • /
    • 1999
  • For the purpose of inquiring into the actual conditions of water quality management of Simple Piped Water Supply(SPWS) and the satisfaction and attitudes of inhabitants about utilizing water-supply, this research was done through the questionnaires, the investigation of surrounding environment and water quality analysis in the Sangju city, Kyungsang-pookdo during 4 months from March to June, 1998. The fountainhead of SPES using ground water accounted for 65.3%, which was the highest rate in the group. Most of them was at least 10 years in the number of utilization year. 79.6% of them were exposed to many sorts of surrounding pollution origins. The examination of water was performed only through a test about water purification and 24.5% of them disinfection by chlorine also no residual chlorine was detected at all. All the waterworks did not have any education to the managers of water quality and 81.5% of them held physical examination. As a result of the water examination about SPWS, 65.3% of them were found incongruity and the valley and springing water accounted for higher than the underground water in the rate of incongruity. Looking into the details of the result in the water examination, a category of colon bacilli was ranked in the highest rate and the next one was general bacilli, nitric acid nitrogen and turbidity in order. In the satisfaction degree of the water quality, the satisfied accounted for 44.6%, and 29.2% each. Over the state of satisfaction about the ways of water examination, satisfaction accounted for 44.6%, and unsatisfaction 28.3%. Summarizing the result of the above-stated, the state of Water Quality Management of the SPWS was in a poor condition. Thus for the water Quality Management, systematic and scientific water Quality Management mainly by the administrative organization other than voluntary management by the village should be done beyond doubt. Additionally the opinions and demands of inhabitants utilizing the water supply have to be positively reflected in the affairs of water Quality Management so that the distrust of inhabitants to the SPWS should be settled.

  • PDF