• Title/Summary/Keyword: Residual Test

Search Result 1,816, Processing Time 0.03 seconds

AN EXPERIMENTAL STUDY OF EFFECT OF INTERMAXILLARY FIXATION AND OCCUSAL SPLINT ON PULMONARY FUNCTION (악간고정과 교합 상이 호흡기능에 미치는 영향에 관한 실험적 연구)

  • Lee, Joong-Kyou;Kim, Kyung-Wook;Lee, Jae-Hoon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.3
    • /
    • pp.175-181
    • /
    • 2002
  • Intermaxillary fixation and occusal splint are routine procedure for maxillofacial fracture and orthognathic surgery. When these methods could obstruct oral airway the patients who kept intermaxillary fixation and occusal splint in their mouth, are very difficult to breath after surgery. Nasal bleeding and pharyngeal edema due to nasotracheal intubation, residual effect of muscle relaxants, and anesthetic agent could be contributing factor of airway obstruction. In this study, pulmonary function test was evaluated before and after intermaxillary fixation, and intermaxillary fixation with occusal splint in 22 volunteers. The results were as follows 1. FVC, %FVC, $FEV_1$, $FEV_1%$, PEF, $PEF_{50}$, MVV without intermaxillary fixtion were 4.45L, 88%, 4.03L, 90.9%, 10.26L/s, 5.53L/s, and 136.14L/min, and with intermaxillary fixation were 3.51L, 68.67%, 3.06L, 69.39L, 6.52L/s, 3.94L/s, and 69.39L/min. The results with intermaxillary fixation and occusal splint were 2.15L, 42.41%, 1.71L, 38.81%, 2.83L/s, 1.74L/s, and 37.14L/min. 2. Compared with before and after intermaxillary fixation, all values of pulmonary function test were decreased and after intermaxillary fixation and intermaixillary fixation with occulasal splint, the results were decreased. 3. MVV and PEF were decreased significantly with interaxillary fixtion and occusal splint, and FVC was less decreased. It meant that intermaxillary fixation and occluasal splint induced reduction of respiratory flow significantly, but less reduction of respiratory volume. 4. Intermaxillary fixation and occulsal splint induced increase of airway resistance, decrease of expiratory volume and air flow. So severe respiratory difficulty could be seen to all volunteers who kept intermaxillary fixtion and occusal splint. 5. In classification of respiratory difficulty, intermaxillary fixation with occulsal splint induced complex respiratory difficulty more than intermaxillary fixation only did. From the above results, doctors who care patients kept intermaxillary fixation and occusal splint should be aware of respiratory depression caused by these treatment.

Geostatistical Approach to Integrated Modeling of Iron Mine for Evaluation of Ore Body (철광산의 광체 평가를 위한 지구통계학적 복합 모델링)

  • Ahn, Taegyu;Oh, Seokhoon;Kim, Kiyeon;Suh, Baeksoo
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.4
    • /
    • pp.177-189
    • /
    • 2012
  • Evaluation of three-dimensional ore body modeling has been performed by applying the geostatistical integration technique to multiple geophysical (electrical resistivity, MT) and geological (borehole data, physical properties of core) information. It was available to analyze the resistivity range in borehole and other area through multiple geophysical data. A correlation between resistivity and density from physical properties test of core was also analyzed. In the case study results, the resistivity value of ore body is decreased contrast to increase of the density, which seems to be related to a reason that the ore body (magnetite) includes heavy conductive component (Fe) in itself. Based on the lab test of physical properties in iron mine region, various geophysical, geological and borehole data were used to provide ore body modeling, that is electrical resistivity, MT, physical properties data, borehole data and grade data obtained from borehole data. Of the various geostatistical techniques for the integrated data analysis, in this study, the SGS (sequential Gaussian simulation) method was applied to describe the varying non-homogeneity depending on region through the realization that maintains the mean and variance. With the geostatistical simulation results of geophysical, geological and grade data, the location of residual ore body and ore body which is previously reported was confirmed. In addition, another highly probable region of iron ore bodies was estimated deeper depth in study area through integrated modeling.

Atmospheric Turbulence Simulator for Adaptive Optics Evaluation on an Optical Test Bench

  • Lee, Jun Ho;Shin, Sunmy;Park, Gyu Nam;Rhee, Hyug-Gyo;Yang, Ho-Soon
    • Current Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.107-112
    • /
    • 2017
  • An adaptive optics system can be simulated or analyzed to predict its closed-loop performance. However, this type of prediction based on various assumptions can occasionally produce outcomes which are far from actual experience. Thus, every adaptive optics system is desired to be tested in a closed loop on an optical test bench before its application to a telescope. In the close-loop test bench, we need an atmospheric simulator that simulates atmospheric disturbances, mostly in phase, in terms of spatial and temporal behavior. We report the development of an atmospheric turbulence simulator consisting of two point sources, a commercially available deformable mirror with a $12{\times}12$ actuator array, and two random phase plates. The simulator generates an atmospherically distorted single or binary star with varying stellar magnitudes and angular separations. We conduct a simulation of a binary star by optically combining two point sources mounted on independent precision stages. The light intensity of each source (an LED with a pin hole) is adjustable to the corresponding stellar magnitude, while its angular separation is precisely adjusted by moving the corresponding stage. First, the atmospheric phase disturbance at a single instance, i.e., a phase screen, is generated via a computer simulation based on the thin-layer Kolmogorov atmospheric model and its temporal evolution is predicted based on the frozen flow hypothesis. The deformable mirror is then continuously best-fitted to the time-sequenced phase screens based on the least square method. Similarly, we also implement another simulation by rotating two random phase plates which were manufactured to have atmospheric-disturbance-like residual aberrations. This later method is limited in its ability to simulate atmospheric disturbances, but it is easy and inexpensive to implement. With these two methods, individually or in unison, we can simulate typical atmospheric disturbances observed at the Bohyun Observatory in South Korea, which corresponds to an area from 7 to 15 cm with regard to the Fried parameter at a telescope pupil plane of 500 nm.

Interfacial Adhesion Energy of Ni-P Electroless-plating Contact for Buried Contact Silicon Solar Cell using 4-point Bending Test System (4점굽힘시험법을 이용한 함몰전극형 Si 태양전지의 무전해 Ni-P 전극 계면 접착력 평가)

  • Kim, Jeong-Kyu;Lee, Eun-Kyung;Kim, Mi-Sung;Lim, Jae-Hong;Lee, Kyu-Hwan;Park, Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.19 no.1
    • /
    • pp.55-60
    • /
    • 2012
  • In order to develop electroless-plated Nickel Phosphate (Ni-P) as a contact material for high efficient low-cost silicon solar cells, we evaluated the effect of ambient thermal annealing on the degradation behavior of interfacial adhesion energy between electroless-plated Ni-P and silicon solar cell wafers by applying 4-point bending test method. Measured interfacial adhesion energies decreased from 14.83 to 10.83 J/$m^2$ after annealing at 300 and $600^{\circ}C$, respectively. The X-ray photoelectron spectroscopy analysis suggested that the bonding interface was degraded by environmental residual oxygen, in which the oxidation inhibit the stable formation of Ni silicide phase between electroless-plated Ni-P and silicon interface.

Assesment of the Characteristics of Hydraulic Storage in Volcanic Region for Applying the Artificial Hydraulic Fracturing - Ulleungdo Site (인공수압파쇄 적용을 위한 울릉도 화산암류 저류특성 평가)

  • Kim Man-Il;Chang Kwang-Soo;Suk Hee-Jun;Kim Hyoung-Soo
    • The Journal of Engineering Geology
    • /
    • v.16 no.2 s.48
    • /
    • pp.125-134
    • /
    • 2006
  • In order to establish the in-situ application of the artificial storage and recovery (ASR) technology which is used the property of the aquifer storage of groundwater. We carried out to the in-situ experiments such as borehole TV logging, pumping test and artificial hydraulic fracturing in volcanic island, Ulleungdo. In-situ experiments were conducted to divide the before- and after-hydraulic fracturing. Pumping test was achieved to confirm the two fracture zones, GL-13m and GL-21m, which are determined by the borehole TV logging. From the results of the before- and after-pumping tests, the hydraulic connectivity was confirmed to locate at GL-13m in the residual deposit zone of pumice media as alluvium. However, in the bedrock tone at GL-21m the hydraulic connectivity could be considered to faulty. Consequently, in this study area the artificial recharge has a little unsatisfied to geo-structural condition and desired to more detail investigation works.

Seroprevalence of Dengue Virus Antibody in Korea (한국인에서 뎅기바이러스 항체의 혈청 유병률 연구)

  • Lee, Ji Hyen;Kim, Han Wool;Kim, Kyung-Hyo
    • Pediatric Infection and Vaccine
    • /
    • v.25 no.3
    • /
    • pp.132-140
    • /
    • 2018
  • Purpose: The number of dengue fever cases is rising due to increasing overseas travel. Vaccination makes severe dengue fever in seronegative individuals after vaccination when they exposure to wild-type dengue virus. We investigated the seroepidemiology of the dengue virus for monitoring of Korean dengue virus immunity and establishing the prevention of dengue infection. Methods: The study was based on 446 residual sera collected from 98 infants (2 months to 1 year old), 152 adolescents (13 to 19 years old), 90 adults (20 to 50 years old), and 106 elderly participants (more than 65 years old) for other studies. Antibody levels for dengue virus immunoglobulin G (IgG) in each age group were measured using an enzyme-linked immunosorbent assay (ELISA). For each dengue virus IgG positive or equivocal result, an IgG ELISA was performed for Japanese encephalitis virus. Results: Of the 446 serum samples, only 1 (0.2%) adolescent had a positive result from the dengue IgG antibody test. In the dengue virus IgG antibody test, 14 (3.1%) samples showed equivocal results (10 adolescents and 4 elderly). In the 1 positive case of dengue virus IgG, the Japanese encephalitis IgG test was also positive. In the 14 equivocal cases of dengue virus IgG, there were 6 positive, 3 equivocal, and 5 negative of Japanese encephalitis IgG. Conclusions: The seroprevalence rate of dengue virus was very low in Koreans. This study provides important data for establishing the policy for preventive measures of dengue fever. It will be necessary to continuously monitor for dengue virus immunity.

Analysis of the Vent Path Through the Pressurizer Manway Under the Loss of Residual Heat Removal(RHR) System During Mid-Loop Operation in PWR (가압경수로 부분충수 운전중 잔열제거 (RHR)계통 상실시 가압기 통로를 통한 배출유로 특성 분석)

  • Ha, G.S.;Kim, W.S.;Chang, W.P.;Yoo, K.J.
    • Nuclear Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.859-869
    • /
    • 1995
  • The present study is to understand the physical phenomena anticipated during the accident with RHR loss under mid-loop operation in a PWR and, at the same time, to examine the prediction capability of RELAP5/MOD3.1 on such an accident, by simulating an integral test relevant to this accident for reliable analysis in an actual PWR. The selected experiment, i.g. BETHSY Test 6.9a, represents the configuration with the pressurizer manway open and steam generators unavailable during the accident. Accordingly, the results of this ok are sure to contribute to understanding both the key events as well as the sensitive parameters, anticipated in the accident, for validity of the actual analysis. In the simulation result overall behavior as well as major phenomena observed in the experiment have been predicted reasonably by RELAP5/MOD3.1, however, the problem associated with enormous computing time .due to small time step size has been encountered. Besides, the code prediction of higher swollen level in the pressure vessel has given rise to overestimation of both pressurizer level and RCS pressure. Subsequently, overprediction of the break flow through the manway has led to earlier core uncovery than that in the experiment by about 400 seconds. As a whole, it is demonstrated from both the experiment and the analysis that gravity feed has not been sufficient to recover the core level and thus additional forced feed has been necessary in this configuration.

  • PDF

An Evaluation of Crack Resistance for Slag Asphalt Concrete Mixture Using Steel Slag Aggregates (제강슬래그 골재를 사용한 슬래그 아스팔트 혼합물의 균열저항성 평가)

  • Kim, Nakseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.71-77
    • /
    • 2023
  • With the continuous industrial development, not only natural resource depletion, waste generation, but also various weather conditions are becoming more frequent. Efforts are continuing to recycle industrial by-products to overcome the climate crisis and save resources. Slag is a representative by-product generated in the steel industry, and it is characterized by improving rutting resistance and moisture sensitivity by increasing strength and reducing deformation when used as a material for asphalt concrete. On the other hand, slag has expansion properties so it is used as a relatively low-value-added material such as embankment and refilling materials. In order to expand the application of slag, an experiment was conducted to evaluate the crack resistance of slag asphalt concrete pavement. As a result of the indirect tensile strength test, it was found that the asphalt mixture using slag aggregate showed a value 1.13 times higher than that of the general HMA with the same particle size, and the toughness was 1.17 units, improving crack resistance. In addition, it was found that the failure number of the 4-point beam fatigue experiment and the slag asphalt mixture was 20,409, which was more than doubled compared to the general HMA. Furthermore, Overlay Test showed a tensile load residual rate of 4 times or more, improving crack resistance to repeated fatigue. Accordingly, the use of slag aggregate will likely have various advantages in improving the performance of asphalt concrete pavement.

The Utility of Immunological Markers and Pulmonary Function Test in the Early Diagnosis of Pulmonary Involvement in the Patients with Rheumatoid Arthritis (류마티스 관절염환자에서 폐침범의 진단에 있어서 면역학적 지표와 폐기능 검사의 유용성)

  • Lee, Dong-Suk;Lee, Chang-Beam;Koh, Hee-Kwan;Moon, Doo-Seop;Lee, Jae-Young;Lee, Kyung-Sang;Yang, Suck-Chul;Yoon, Ho-Joo;Bae, Sang-Cheol;Shin, Dong-Ho;Kim, Seong-Yoon;Park, Sung-Soo;Lee, Jung-Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.878-887
    • /
    • 1995
  • Background: It is reported that frequency of pulmonary involvement in the patients with rheumatoid arthritis reaches 10 to 50% and pulmonary involvement is a principal cause of death. As immunology and radiology has developed, interest for the early diagnosis of pulmonary involvement is increasing. Method: Among the patients at Hanyang University Hospital from March, 1990 to July, 1995, we compared the 29 patients having pulmonary involvement with the 18 patients controls in clinical and chest high resolution computed tomography(HRCT) findings by immunological markers and findings of pulmonary function test. We sought useful markers for early diagnosis of pulmonary involvement with noninvasive investigations. Results: The ratio of males to females was 14 : 15 in the group of pulmonary involvement, and all of the 18 patients were females in the control group. Smoking history was 31%(9/29) in the former group and none in the latter group. Rheumatoid factor(RF) was positive in 95.5%(28/29) of the pulmonary involvement group and in 100%(18/18) of the control group(p=0.12). Antiperinuclear factor(APF) showed a significant difference: 86.9%(20/23, average value: 2.0) was positive in the pulmonary involvement group and 50%(8/16, average value: 1.1) in the control group(p=0.04). Antinuclear antibody(ANA) was positive in 60.7%(17/28) of the pulmonary involvement group and in 72.2%(13/18) of the control group(p=0.33). Cryoglobulin also showed a significant difference: 72%(18/25) in the pulmonary involvement group was positive and 56.2%(9/16) in the control group was positive(p=0.02). Bony erosion was positive in 61.5%(16/26) of the pulmonary involvement group and in 77.7%(14/18) of the control group(p=0.8). On the pulmonary function test, the average value of alveolar volume corrected diffusion capacity and residual volume in the pulmonary involvement group and in the control group were 1.07mmol/rnin/KPa(predicted value: 64.2%), 1.32L(predicted value: 70%) and 1.44mmol/min/KPa, 3.75L(predicted value: 86.6%), respectively(p=0.003, p=0.004), showing a significant difference. Conclusion: APF or cryoglobulin on the serological test, the measurement of residual volume and alveolar volume corrected diffusion capacity may be used as effective markers in the diagnosis of pulmonary involvement of the patients with rheumatoid arthritis.

  • PDF

Experimental Study on Combined Failure Damage of Bi-directional Prestressed Concrete Panel under Impact-Fire Loading (충돌 후 화재에 대한 이방향 프리스트레스트 콘크리트 패널부재의 복합 파괴손상에 관한 실험적 연구)

  • Yi, Na-Hyun;Lee, Sang-Won;Choi, Seung-Jai;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.429-440
    • /
    • 2014
  • Since the World Trade Center and Pentagon attacks in 2001, terror, military attack, or man-made disaster caused impact, explosion, and fire accident have frequently occured on civil infrastructures. However, structural behavior researches on major Prestressed Concrete (PSC) infrastructures such as bridges, tunnels, Prestressed Concrete Containment Vessel (PCCVs), and LNG tanks under extreme loading are significantly lacking. Especially, researches on possible secondary fire scenarios after terror, bombing, collision of vehicles and vessels on concrete structures have not been performed domestically where most of the past researches related to extreme loadings on structures focused on an independent isolated extreme loading scenario. Due to the outcry of public concerns and anxiety of potential terrorist attacks on major infrastructures and structures, a study is urgently needed at this time. Therefore, in this study, the bi-directional prestressed concrete $1400{\times}1000{\times}300mm$ panels applied with 430 kN prestressing force using unbonded prestressing thread bars were experimentally evaluated under impact, fire, and impact-fire combined loadings. Due to test site restrictions, impact tests were performed with 14 kN impactor with drop heights of 10m and 3.5 m to evaluate impact resistance capacity. Also, fire and impact-fire combined loading were tested using RABT fire loading curve. The measured residual strength capacities of PSC and RC specimens applied with impact, fire, impact-fire combined loadings were compared with the residual strength capacity of undamaged PSC and RC specimens for evaluation. The study results can be used as basic research data for related research areas such as protective design and numerical simulation under extreme loading scenarios.